MITSUBISHI ELECTRIC PLA-A36EA7 Ceiling Cassette Owner’s Manual

June 17, 2024
Mitsubishi Electric

PLA-A36EA7 & PUZ-HA36NKA
36,000 BTU/H 3’ X 3’ CEILING CASSETTE
36,000 BTU/H HYPER-HEATING UNIVERSAL OUTDOOR
Job Name:
System Reference: Date:

MITSUBISHI ELECTRIC PLA-A36EA7 Ceiling Cassette

Indoor Unit PLA-A36EA7
Outdoor Unit PUZ-HA36NKA

INDOOR UNIT FEATURES

  • Space-efficient ductless installation
  • Equipped with 3D i-see Sensor® for enhanced comfort and energy efficiency
  • Airflow settings for high and low ceiling applications
  • Individual vane settings for direct/indirect airflow control or variable airflow patterns
  • Knockouts for outside-air intake and branch-duct run
  • Filter indicator signal
  • Easy-to-clean, washable filter (optional high-efficiency filter available – requires multi-function casement)
  • Built-in condensate lift mechanism
  • Ideal for retail shops, classrooms, office spaces, conference centers, building lobbies, and more
  • Multiple control options available:
    ○ kumo cloud® smart device app for remote access
    ○ Third-party interface options
    ○ Wired or wireless controllers

OUTDOOR UNIT FEATURES

  • Variable speed INVERTER-driven compressor
  • High heating capacity: flash injection circuit maintains 100% heating capacity at 5°F outdoor temperature
  • Wide heating range: heating performance down to -13°F (average of 80% heating capacity)
  • High speed heating at start up: Hyper-Heating INVERTER® reduces the time for heating at start up by about half compared to standard models
  • Suction accumulator pre-charged with refrigerant volume for piping length up to 100 ft.
  • High pressure/temperature protection
  • Built-in base pan heater
  • Flash injection circuit provides efficient high heating capacities at low ambient temperatures

SPECIFICATIONS: PLA-A36EA7 & PUZ-HA36NKA

Cooling at 95°F1 Maximum Capacity BTU/H 36,000
Rated Capacity BTU/H 36,000
Minimum Capacity BTU/H 14,800
Maximum Power Input W 2,750
Rated Power Input W 2,750
Moisture Removal Pints/h 5.5
Sensible Heat Factor 0.83
Power Factor [208V / 230V] % 98.0 / 98.0
Heating at 47°F2 Maximum Capacity BTU/H 40,000
Rated Capacity BTU/H 38,000
Minimum Capacity BTU/H 16,700
Maximum Power Input W 2,880
Rated Power Input W 2,650
Power Factor [208V / 230V] % 98.0 / 98.0
Heating at 17°F3 Maximum Capacity BTU/H 38,000
Rated Capacity BTU/H 24,200
Maximum Power Input W 4,785
Rated Power Input W 2,715
Heating at 5°F4 Maximum Capacity BTU/H 38,000
Maximum Power Input W 5,465
Heating at -13°F7 Maximum Capacity BTU/H 30,400
Efficiency SEER2 20.0
EER21 13.0
HSPF2 [IV] 9.0
COP at 47°F2 4.2
COP at 17°F at Maximum Capacity3 2.3
COP at 5°F at Maximum Capacity4 2.0
Electrical Voltage, Phase, Frequency 208/230, 1, 60
Guaranteed Voltage Range V AC 198 – 253
Voltage: Indoor – Outdoor, S1-S2 V AC 208/230
Voltage: Indoor – Outdoor, S2-S3 V DC 24
Short-circuit Current Rating [SCCR] kA 5
Recommended Fuse/Breaker Size (Oudoor) A 35
Recommended Wire Size [Indoor – Outdoor] AWG 14
Power Supply Indoor unit is powered by the outdoor unit
Indoor Unit MCA A 2.0
Fan Motor Full Load Amperage A 0.95
Fan Motor Type DC Motor
Airflow Rate at Cooling, Dry CFM 670–850–1,020–1,200
Airflow Rate at Cooling, Wet CFM 630–810–980–1,160
Airflow Rate at Heating, Dry CFM 670–850–1,020–1,200
Sound Pressure Level [Cooling] dB[A] 32–37–41–44
Sound Pressure Level [Heating] dB[A] 32–37–41–44
Drain Pipe Size In. [mm] 1-1/4 [32]
Condensate Lift Mechanism, Maximum Distance In. [mm] 33-7/16 [849]
Coating on Heat Exchanger
External Finish Color White Munsell 6.4Y 8.9/0.4
Unit Dimensions W x D x H: In.[mm] 33-1/16 // 37-13/32 x 33-1/16 // 37-13/32

x 11-3/4 // 1-9/16 [840 // 950 x 840 // 950 x 298 // 40]
Package Dimensions| W x D x H: In.[mm]| 35-9/16 // 39-6/16 x 34-5/16 // 38-3/16 x 16-9/16 // 4-12/16 [903 // 1,000 x 871 // 970 x 421 // 121]
Unit Weight| Lbs. [kg]| 56 // 11 [25 // 5]
Package Weight| Lbs. [kg]| 77 [35]
Indoor Unit Operating Temperature Range| Cooling Intake Air Temp [Maximum / Minimum]*| °F| 90 DB, 72 WB / 66 DB, 61 WB
Heating Intake Air Temp [Maximum / Minimum]| °F| 77 DB / 59 DB

NOTES:
AHRI Rated Conditions
(Rated data is determined at a fixed compressor speed)

  1. Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB

  2. Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB

  3. Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB
    Conditions

  4. Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB

  5. Heating at -13°F (Indoor // Outdoor) °F 70 DB, 60 WB // -13 DB, -14 WB

  • Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]):
    • Wind baffles required to operate below 23°F DB in cooling mode.
    • Refer to wind baffle documentation for further information.
    **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re- start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
    • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.

SPECIFICATIONS: PLA-A36EA7 & PUZ-HA36NKA

Outdoor Unit MCA A 24.0
MOCP A 42
Fan Motor Output W 74
Airflow Rate [Cooling / Heating] CFM 3880 / 3880
Refrigerant Control LEV
Defrost Method Reverse Cycle
Sound Pressure Level, Cooling1 dB(A) 52
Sound Pressure Level, Heating2 dB(A) 53
Compressor Type Scroll
Compressor Model ANB33FJMMT
Compressor Rated Load Amps A 18
Compressor Locked Rotor Amps A 27.5
Compressor Oil [Type // Charge] oz. FV50S // 1.4,47
External Finish Color Ivory Munsell 3Y 7.8/1.1
Base Pan Heater Built-in
Unit Dimensions W x D x H: In. [mm] 41-5/16 x 14-3/16 x 52-11/16 [1050 x 360

x 1338]
Package Dimensions| W x D x H: In. [mm]| 43 x 18 x 57 [1110 x 480 x 1440]
Unit Weight| Lbs. [kg]| 261 [118]
Package Weight| Lbs. [kg]| 285 [129]
Outdoor Unit Operating Temperature Range| Cooling Air Temp [Maximum / Minimum]*| °F| 115 DB / 0 DB
Heating Air Temp [Maximum / Minimum]| °F| 70 DB, 59 WB / -13 DB, -13 WB
Heating Thermal Lock-out / Re-start Temperatures**| °F| -22 / -13
Refrigerant| Type| R410A
Pre-Charged Refrigerant Amount| Lbs, oz| 11.0, 7.0
Maximum Pre-Charged Piping Length| Ft. [m]| 100.0 [30.0]
Additional Refrigerant Charge Per Additional Piping Length| oz./Ft. [g/m]| .7 [56]
Piping| Gas Pipe Size O.D. [Flared]| In.[mm]| 5/8 [15.88]
Liquid Pipe Size O.D. [Flared]| In.[mm]| 3/8 [9.52]
Maximum Piping Length| Ft. [m]| 245 [75]
Maximum Height Difference| Ft. [m]| 100 [30]
Maximum Number of Bends| 15

NOTES:
AHRI Rated Conditions
(Rated data is determined at a fixed compressor speed)

  1. Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB

  2. Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB

  3. Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB
    Conditions

  4. Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB

  5. Heating at -13°F (Indoor // Outdoor) °F 70 DB, 60 WB // -13 DB, -14 WB

  • Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]):
    • Wind baffles required to operate below 23°F DB in cooling mode.
    • Refer to wind baffle documentation for further information.
    **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re- start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
    • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.

INDOOR UNIT ACCESSORIES: PLA-A36EA7

Control Interface 3-Pin Connector □ PAC-715AD
Airzone ZBS Wired Blueface Principal Controller White □ AZZBSBLUEFACECB
Airzone ZBS Wired Blueface Principal Controller White □ AZZBSBLUEZEROCB
Airzone ZBS Wired Lite Controller White □ AZZBSLITECB
Airzone ZBS Wireless Lite Controller White □ AZZBSLITERB
Airzone ZBS Wireless Think Controller White □ AZZBSTHINKRB
CN24 Relay Kit □ CN24RELAY-KIT-CM3
IT Extender □ PAC-WHS01IE-E
kumo station® for kumo cloud® □ PAC-WHS01HC-E
Procon BACnet® and Modbus® Interface □ PAC-UKPRC001-CN-1
Remote Operation Adapter‡ □ PAC-SF40RM-E
Thermostat Interface □ PAC-US444CN-1
Thermostat Interface □ PAC-US445CN-1
USNAP Adapter □ PAC-WHS01UP-E
Wireless Interface for kumo cloud® □ PAC-USWHS002-WF-2
Remote Sensor Flush Mount Remote Temperature Sensor □ PAC-USSEN002-FM-1
Flush Mount Temperature Sensor □ PAC-USSEN001-FM-1
Remote Temperature Sensor □ PAC-SE41TS-E
Wireless temperature and humidity sensor for kumo cloud® □ PAC-USWHS003-TH-1
Wired Remote Controller Deluxe Wired MA Remote Controller† □ PAR-40MAAU
Simple Ductless Wired Remote Controller □ PAC-SDW01RC-1
Simple MA Remote Controller† □ PAC-YT53CRAU-J
Touch MA Controller† □ PAR-CT01MAU-SB
Wireless Remote Controller kumo touch™ RedLINK™ Wireless Controller □ MHK2
Lockdown bracket for remote controller □ RCMKP1CB
Wireless MA Receiver □ PAR-FA32MA-W
Wireless MA Remote Controller □ PAR-FL32MA-E
Wireless Remote Contoller □ PAR-SL101A-E
Wireless Signal Receiver Panel □ PAR-SR4LU-E
Casement Multi-function Casement □ PAC-SJ41TM-E
Condensate Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor
(208/230V) [recommended] □ X87-721
Blue Diamond (MegaBlue Advanced) Condensate Pump w/ Reservoir & Sensor

X87-835
Blue Diamond Sensor Extension Cable — 15 Ft.| □ C13-103
Refco Condensate Pump (100-240 VAC) up to 120,000 BTU/H| □ COMBI
Disconnect Switch| (30A/600V/UL) [fits 2” X 4” utility box] – Black| □ TAZ- MS303
(30A/600V/UL) [fits 2” X 4” utility box] – White| □ TAZ-MS303W
Filter| High Efficiency Filter Element**| □ PAC-SH59KF-E
i-see Sensor® Panel| Grille with 3D i-see Sensor® (required)| □ PLP-41EAEU
Lineset| 10’ x 3/8” x 10’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-10
100’ x 3/8” x 100’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-100
15’ x 3/8” x 15’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-15
30’ x 3/8” x 30’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-30
50’ x 3/8” x 50’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-50
65’ x 3/8” x 65’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-65
Shutter Plate| Shutter Plate| □ PAC-SJ37SP-E
Space Panel| Space Panel| □ PAC-SJ38AS-E

NOTES:
‡ PAC-SF40RM-E (Unable to use with wireless remote controller)

OUTDOOR UNIT ACCESSORIES: PUZ-HA36NKA

Air Outlet Guide| Air Outlet Guide (1 Piece)| □ PAC-SH96SG-E (two pieces are required)
---|---|---
Centralized Drain Pan| Central Drain Pan| □ PAC-SH97DP-E
Control/Service Tool| Control/Service Tool| □ PAC-SK52ST
Hail Guards| Hail Guard| □ HG-A2
M-NET Converter| M-NET Converter| □ PAC-SJ85MA-E
M-NET Converter| □ PAC-SJ95MA-E
Mounting Pad| Condensing Unit Mounting Pad: 24” x 42” x 3”| □ ULTRILITE2
Optional Defrost Heater| Optional Defrost Heater| □ PAC-SJ20BH-E
Stand| 18” Dual Fan Stand| □ QSMS1802M
24” Dual Fan Stand| □ QSMS2402M
Condenser Wall Bracket| □ QSWB2000M-1
Condenser Wall Bracket – Stainless Steel Finish| □ QSWBSS
Outdoor Unit Stand — 12” High| □ QSMS1202M
Wind Baffle| Front Wind Baffle| □ WB-PA3 (two pieces are required)

INDOOR UNIT DIMENSIONS: PLA-A36EA7
MITSUBISHI ELECTRIC PLA-A36EA7 Ceiling Cassette - INDOOR UNIT
DIMENSIONS OUTDOOR UNIT DIMENSIONS: PUZ-HA36NKA
MITSUBISHI ELECTRIC PLA-A36EA7 Ceiling Cassette - OUTDOOR UNIT
DIMENSIONS FORM# PLA- A36EA7 & PUZ-HA36NKA – 202307
Specifications are subject to change without notice.
1340 Satellite Boulevard Suwanee, GA 30024
Toll Free: 800-433-4822 www.mehvac.com

© 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Mitsubishi Electric User Manuals

Related Manuals