CHAMPION POWER EQUIPMENT 201156 3650W Wireless Remote Start Generator User Manual
- June 15, 2024
- CHAMPION POWER EQUIPMENT
Table of Contents
- CHAMPION POWER EQUIPMENT 201156 3650W Wireless Remote Start Generator
- Specifications
- Product Usage Instructions
- Controls and Features
- Assembly
- Operation
- Maintenance
- Storage
- FAQ
- INTRODUCTION
- IMPORTANT SAFETY INSTRUCTIONS
- CONTROLS AND FEATURES
- OPERATION
- DRAIN BOLT
- MAINTENANCE
- SPECIFICATIONS
- TROUBLESHOOTING
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
CHAMPION POWER EQUIPMENT 201156 3650W Wireless Remote Start Generator
Specifications
- Model: #201156
- Power Output: 3650W
- Start Type: Wireless Remote Start
- Manufacturer: Champion Power Equipment, Inc.
- Location: Santa Fe Springs, CA, USA
Product Usage Instructions
Introduction
Thank you for choosing the Champion Power Equipment Model #201156 3650W
Wireless Remote Start Generator. This operator’s manual will provide you with
all the necessary information to safely and effectively use your generator.
Safety Definitions
Before operating the generator, it is important to understand the following
safety definitions:
- Carbon Monoxide Kills: Carbon monoxide is a deadly gas that can be produced by the generator. It is important to take necessary precautions to prevent carbon monoxide poisoning.
- Carbon Monoxide Safety: This section emphasizes the importance of using the generator outdoors and provides general safety tips to protect your family from carbon monoxide exposure.
- Always Read Manual First: It is crucial to read and understand the operator’s manual before operating the generator to ensure proper usage and prevent accidents.
- Know the Symptoms: This section informs users about the symptoms of carbon monoxide poisoning and emphasizes the importance of leaving the area immediately if experiencing any symptoms.
- Stay Alert with Carbon Monoxide Detectors: Installing carbon monoxide detectors in your living space is highly recommended to ensure early detection of any carbon monoxide leaks.
- Keep It Outside and Away from Doors, Windows, and Garages: This safety tip highlights the importance of positioning the generator outdoors and away from any openings that could allow carbon monoxide to enter your living space.
- Point Fumes Away from Nearby People: To prevent any accidental exposure to carbon monoxide, it is essential to direct the generator’s fumes away from people in the vicinity.
Controls and Features
The generator is equipped with the following controls and features:
- Generator: This section provides an overview of the generator itself, including its components and how it operates.
- Control Panel: The control panel is where you can find various switches, outlets, and indicators to control and monitor the generator’s functions.
- Intelligauge: The Intelligauge displays important information about the generator’s performance, such as voltage, frequency, and operating hours.
- Wireless Remote Control: The wireless remote control allows you to start and stop the generator from a distance, providing convenience and ease of use.
Assembly
Before using the generator, it is necessary to assemble certain components. Please follow these steps:
- Unpacking: Carefully remove all packaging materials from the generator.
- Remove Shipping Support Brackets: Take off any shipping support brackets that may be attached to the generator.
- Install the Wheel Kit: Attach the wheel kit to make the generator portable and easy to move.
- Connect the Battery: Connect the battery to ensure proper starting and operation of the generator.
- Add Engine Oil: Add the recommended engine oil to ensure smooth performance and lubrication.
- Add Fuel: Fill the fuel tank with the recommended type of fuel.
- Grounding: Properly ground the generator to prevent electrical hazards.
Operation
Once the generator is assembled, follow these steps to operate it:
- Turn on the Fuel Valve: Open the fuel valve to allow fuel flow to the engine.
- Choke Control: Adjust the choke control according to the temperature conditions for easy starting.
- Start the Generator: Follow the specific instructions for starting the generator, whether using the wireless remote control or the manual start method.
- Monitor the Intelligauge: Keep an eye on the Intelligauge to ensure the generator is operating within normal parameters.
- Power Output: Connect your electrical devices to the generator’s outlets, ensuring not to exceed its power rating.
- Shutdown Procedure: When you are finished using the generator, follow the proper shutdown procedure to prevent damage and ensure safe operation in future use.
Maintenance
Regular maintenance is essential for optimal performance and longevity of your generator. Refer to the operator’s manual for detailed maintenance instructions, including oil changes, filter replacements, and general inspection procedures.
Storage
If you need to store the generator for an extended period, follow the recommended storage procedures outlined in the operator’s manual. Proper storage will help prevent damage and ensure the generator is ready for use when needed.
FAQ
Q: How often should I change the engine oil?
A: It is recommended to change the engine oil after every 25 hours of
operation or at least once a year, whichever comes first. Refer to the
operator’s manual for the specific oil type and change procedure.
Q: Can I use the wireless remote control to start the generator from
inside my house?
A: No, it is not recommended to start the generator using the wireless
remote control from inside your house. The generator should always be started
outdoors in a well-ventilated area to prevent carbon monoxide buildup.
Q: What type of fuel should I use for the generator?
A: Use only unleaded gasoline with a minimum octane rating of 87. Do not
use gasoline blends containing more than 10% ethanol. Refer to the operator’s
manual for more information on fuel requirements.
Q: Can I connect sensitive electronic devices directly to the
generator?
A: It is recommended to use a surge protector or voltage regulator when
connecting sensitive electronic devices to the generator. This will help
protect them from voltage fluctuations and ensure their safe operation.
Q: How do I ground the generator?
A: Proper grounding is crucial for electrical safety. Follow the grounding
instructions provided in the operator’s manual to ensure correct and safe
grounding of the generator.
OPERATOR’S MANUAL
MODEL #201156 3650W WIRELESS REMOTE
START GENERATOR
REGISTER YOUR PRODUCT ONLINE at championpowerequipment.com
or visit championpowerequipment.com
SAVE THESE INSTRUCTIONS. This manual contains important safety precautions
which should be read and understood before operating the product. Failure to
do so could result in serious injury. This manual should remain with the
product. Specifications, descriptions and illustrations in this manual are as
accurate as known at the time of publication, but are subject to change
without notice. This product meets the requirements of the PGMA (Portable
Generator Manufacturers’ Association) standard ANSI/PGMA G300-2018 (Safety and
Performance of Portable Generators). Covered by one or more of the following
U.S. Patent Numbers: 10,862,414 and other U.S. and foreign patents pending.
3416-M-OP REV 20230628 EN
Champion Power Equipment, Inc., Santa Fe Springs, CA USA
CARBON MONOXIDE KILLS
CARBON MONOXIDE SAFETY: THE BIG PICTURE
As the only safe way to use a portable generator, taking your generator
outside is absolutely mandatory to keep your family safe from carbon monoxide.
But there’s even more you can do. By educating yourself about all carbon
monoxide risks, you’ll be better prepared to protect your family from this
colorless, oderless threat.
ALWAYS READ MANUAL THE OPERATOR’S
MANUAL FIRST
KNOW THE SYMPTOMS
· Headache
· Dizziness
· Nausea
· Fatigue
· Shortness of breath
STAY ALERT WITH CARBON MONOXIDE DETECTORS
KEEP IT OUTSIDE AND AWAY FROM DOORS, WINDOWS, AND GARAGES
IF YOU FEEL SYMPTOMS, LEAVE RIGHT AWAY
POINT FUMES AWAY FROM NEARBY PEOPLE
www.TakeYourGeneratorOutside.com
201156 – 3650W WIRELESS REMOTE START GENERATOR
FOR PARTS BREAKDOWN
Search by model number at championpowerequipment.com
3
201156 – 3650W WIRELESS REMOTE START GENERATOR
INTRODUCTION
Congratulations on your purchase of a Champion Power Equipment (CPE) product.
CPE designs, builds, and supports all of our products to strict specifications
and guidelines. With proper product knowledge, safe use, and regular
maintenance, this product should bring years of satisfying service.
Every effort has been made to ensure the accuracy and completeness of the
information in this manual at the time of publication, and we reserve the
right to change, alter and/or improve the product and this document at any
time without prior notice.
CPE highly values how our products are designed, manufactured, operated, and
serviced as well as providing safety to the operator and those around the
generator. Therefore, it is IMPORTANT to review this product manual and other
product materials thoroughly and be fully aware and knowledgeable of the
assembly, operation, dangers and maintenance of the product before use. Fully
familiarize yourself, and make sure others who plan on operating the product
fully familiarize themselves too, with the proper safety and operation
procedures before each use. Please always exercise common sense and always err
on the side of caution when operating the product to ensure no accident,
property damage, or injury occurs. We want you to continue to use and be
satisfied with your CPE product for years to come.
When contacting CPE about parts and/or service, you will need to supply the
complete model and serial numbers of your product. Transcribe the information
found on your product’s nameplate label to the table below
CPE TECHNICAL SUPPORT TEAM
1-877-338-0999
MODEL NUMBER
201156
SERIAL NUMBER
INTRODUCTION
SAFETY DEFINITIONS
The purpose of safety symbols is to attract your attention to possible
dangers. The safety symbols, and their explanations, deserve your careful
attention and understanding. The safety warnings do not by themselves
eliminate any danger. The instructions or warnings they give are not
substitutes for proper accident prevention measures.
DANGER
DANGER indicates a hazardous situation which, if not avoided, will result in
death or serious injury.
WARNING
WARNING indicates a hazardous situation which, if not avoided, could result in
death or serious injury.
CAUTION
CAUTION indicates a hazardous situation which, if not avoided, could result in
minor or moderate injury.
NOTICE
NOTICE indicates information considered important, but not hazard-related
(e.g., messages relating to property damage).
DATE OF PURCHASE
PURCHASE LOCATION
4
201156 – 3650W WIRELESS REMOTE START GENERATOR
IMPORTANT SAFETY INSTRUCTIONS
WARNING
Cancer and Reproductive Harm www.P65Warnings.ca.gov
DANGER
Generator exhaust contains carbon monoxide, a colorless, odorless, poisonous
gas. Breathing carbon monoxide will cause nausea, dizziness, fainting or
death. If you start to feel dizzy or weak, get to fresh air immediately.
OPERATE GENERATOR OUTDOORS ONLY IN A WELL VENTILATED AREA AND POINT EXHAUST
AWAY. DO NOT operate the generator inside any building, including garages,
basements, crawlspaces and sheds, enclosure or compartment, including the
generator compartment of a recreational vehicle. DO NOT allow exhaust fumes to
enter a confined area through windows, doors, vents or other openings.
DANGER
Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains
carbon monoxide. This is a poison you cannot see or smell. NEVER use inside a
home or garage, EVEN IF doors and windows are open. ONLY use OUTSIDE and far
away from windows, doors, and vents.
Install battery-operated carbon monoxide alarms or plug-in carbon monoxide
alarms with battery back-up according to the manufacturer’s instructions.
IMPORTANT SAFETY INSTRUCTIONS
DANGER
Operate equipment with guards in place. Rotating parts can entangle hands,
feet, hair, clothing and/or accessories. Traumatic amputation or severe
laceration can result.
Keep hands and feet away from rotating parts. Tie up long hair and remove
jewelry. DO NOT wear loose-fitting clothing, dangling drawstrings or items
that could become caught.
DANGER
Generator produces powerful voltage.
DO NOT touch bare wires or receptacles. DO NOT use electrical cords that are
worn, damaged or frayed. Use only Champion electrical cords for proper
application. DO NOT operate generator in wet weather. DO NOT allow children or
unqualified persons to operate or service the generator. Use a ground fault
circuit interrupter (GFCI) in damp areas and areas containing conductive
material such as metal decking. Connection to your home’s electrical system
requires a listed 30A transfer switch installed by a licensed electrician and
approved by the local authority having jurisdiction. The connection must
isolate the generator from the utility power and must comply with all
applicable laws and electrical codes.
WARNING
Do not use generator for medical and life support uses.
In case of emergency, call 911 immediately. NEVER use this product to power
life support devices or life support appliances. NEVER use this product to
power medical devices or medical appliances. Inform your electricity provider
immediately if you or anyone in your household depends on electrical equipment
to live. Inform your electrical provider immediately if a loss of power would
cause you or anyone in your household to experience a medical emergency.
5
201156 – 3650W WIRELESS REMOTE START GENERATOR
WARNING
Spark from removed spark plug wire can result in fire or electrical shock.
When servicing the generator: Disconnect the spark plug wire and place it
where it cannot contact the plug or any other metal object. DO NOT check for
spark with the plug removed. Use only approved spark plug testers.
WARNING
Running engines produce heat. Severe burns can occur on contact. Combustible
material can catch fire on contact.
DO NOT touch hot surfaces. Avoid contact with hot exhaust gases. Allow
equipment to cool before touching. Maintain at least 3 ft. (91.4 cm) of
clearance on all sides to ensure adequate cooling. Maintain at least 5 ft.
(1.5 m) of clearance from combustible materials.
WARNING
Rapid retraction of the recoil cord will pull hand and arm towards the engine
faster than you can let go. Broken bones, fractures, bruises or sprains could
result. Unintentional startup can result in entanglement, traumatic amputation
or laceration.
When starting engine, pull the recoil cord slowly until resistance is felt and
then pull rapidly to avoid kickback. DO NOT start or stop the engine with
electrical devices plugged in and turned on.
WARNING
Although the generator contains a spark arrester, maintain a minimum distance
of 5 ft. (1.5 m) from dry vegetation to prevent fires.
CAUTION
Exceeding the generator’s running capacity can damage the generator and/or
electrical devices connected to it.
DO NOT overload the generator. DO NOT tamper with the governed speed. DO NOT
modify the generator in any way.
IMPORTANT SAFETY INSTRUCTIONS
CAUTION
Start the generator and allow the engine to stabilize before connecting
electrical loads. Connect electrical equipment in the off position, and then
turn them on for operation. Turn electrical equipment off and disconnect
before stopping the generator.
CAUTION
Improper treatment or use of the generator can damage it, shorten its life or
void the warranty.
Use the generator only for intended uses. Operate only on level surfaces. DO
NOT expose generator to excessive moisture, dust, or dirt. DO NOT allow any
material to block the cooling slots. If connected devices overheat, turn them
off and disconnect them from the generator. DO NOT use the generator if:
Electrical output is lost Equipment sparks, smokes or emits flames
Equipment vibrates excessively
DANGER
Tampering with the CO Shield® system will result in a hazardous condition and
will void your warranty. Removing the CO Shield® module will not allow the
generator to start.
6
201156 – 3650W WIRELESS REMOTE START GENERATOR
Fuel Safety
DANGER
GASOLINE AND GASOLINE VAPORS ARE HIGHLY FLAMMABLE AND EXPLOSIVE.
Fire or explosion can cause severe burns or death.
Gasoline and gasoline vapors: Gasoline vapors are highly flammable and
explosive. Gasoline vapors can cause a fire or explosion if ignited.
Gasoline is a liquid fuel and the resulting gasoline vapors can
ignite and cause a fire or explosion. Gasoline is a skin irritant and needs
to be cleaned up
immediately if spilled on skin or clothes. Gasoline has a distinctive odor,
this will help detect potential
leaks quickly. In any petroleum gas fire, flames should not be extinguished
unless by doing so the fuel supply valve can be turned OFF. This is because if
a fire is extinguished and a supply of fuel is not turned OFF, then an
explosion hazard could be created. Gasoline vapors expand and contract with
ambient temperatures. Never fill the gasoline tank past the red FULL indicator
on the fuel filter, as gasoline vapors needs room to expand if temperatures
rise.
WARNING
When adding or removing gasoline: Do not light or smoke cigarettes. Always
stop the engine and allow to cool for a minimum of two minutes before
refueling. Always loosen gasoline cap slowly to release vapor pressure and to
keep fuel from escaping around the gasoline cap. Always replace and tighten
the gasoline cap securely after fueling. Never remove the gasoline cap or add
gasoline while the engine is running or when the engine is hot. Only fill or
drain gasoline outdoors in a well-ventilated area. Do not pump gasoline
directly into the generator at the gas station. Always store gasoline in an
EPA/CARB compliant container or to transfer the gasoline to the generator. Do
not overfill the gasoline tank. Always keep gasoline away from sparks, open
flames, pilot lights, heat and other sources of ignition.
IMPORTANT SAFETY INSTRUCTIONS
WARNING
When starting the generator: Do not attempt to start a damaged generator.
Always check that the gasoline cap, air filter, spark plug, fuel lines and
exhaust system are properly in place. Always allow spilled gasoline to
evaporate fully before attempting to start the engine. Always be certain that
the generator is resting firmly on level ground.
WARNING
When operating the generator: Do not move or tip the generator during
operation.
WARNING
When transporting or servicing the generator: Always check that the fuel valve
is in the OFF position and the gasoline tank is empty. Disconnect the spark
plug wire.
WARNING
When storing the generator: Store away from sparks, open flames, pilot lights,
heat and other sources of ignition. Do not store generator or gasoline near
furnaces, water heaters, or any other appliances that produce heat or have
automatic ignitions.
DANGER
Never place a gasoline container, gasoline tank, LPG cylinder or any
combustible material in the path of the exhaust stream during operation of the
engine.
WARNING
Never use a gasoline container, gasoline tank, or any other fuel item that is
broken, cut, torn or damaged.
7
201156 – 3650W WIRELESS REMOTE START GENERATOR
IMPORTANT SAFETY INSTRUCTIONS
Safety and Dataplate Labels
These labels warn you of potential hazards that can cause serious injury. Read
them carefully. If a label comes off or becomes hard to read, contact
Technical Support Team for possible replacement.
C
A
B
E D
Top LABEL
A B
DANGER
PELIGRO
2205-L-SF-C
DANGER
Using a generator indoors CAN KILL
El uso de un generador en
Utiliser un génératrice à l’intérieur
YOU IN MINUTES. Generator exhaust interiores PUEDE MATARLO EN PEUT VOUS TUER EN QUELQUES
contains carbon monoxide. This is a
MINUTOS. El escape del
MINUTES. L’échappement de la
poison you cannot see or smell.
generador contiene monóxido de génératrice contient du monoxyde
carbono. Éste es un veneno que de carbone. Il s’agit d’un poison
no se puede ver ni oler. NUNCA que vous ne pouvez ni voir ni
lo use dentro del hogar ni el
sentir. Ne l’utilisez JAMAIS dans
garaje, INCLUSO SI las puertas la maison ou le garage MÊME SI
NEVER use inside a home or garage, EVEN IF doors and windows are open.
ONLY use OUTSIDE and far away from windows, doors, and vents.
y ventanas están abiertas. Úselo SÓLO a la INTEMPERIE lejos de ventanas, puertas, y orificios de ventilación.
les portes et les fenêtres sont ouvertes. Utilisez la UNIQUEMENT À L’EXTÉRIEUR, loin des fenêtres, portes et trappes de ventilation.
ACTION LABEL ETIQUETA DE ACCIÓN ÉTIQUETTE D’ACTION
AUTOMATIC SHUTOFF YOU MUST: APAGADO AUTOMÁTICO USTED DEBE: ARRÊT AUTOMATIQUE VOUS DEVEZ :
Move generator to an open, outdoor area. Point exhaust away. Don’t run generators in enclosed areas (e.g. not in house or garage).
Move to fresh air and get medical help if sick, dizzy or
weak.
Mover el generador a un área abierta a la intemperie. Apunte el escape alejado.
No corra los generadores en áreas cerradas (ej. no en una casa o garaje).
Mueva al aire fresco y obtenga
asistencia medica si está
Déplacer le générateur vers un espace
enfermo, mareado, o débil.
extérieur en plein air. Garder l’échappement
loin. Ne pas faire fonctionner les générateurs Aller à l’air frais et obtenir
dans un espace clos (ex., pas dans une maison de l’aide médicale si
ou un garage).
malade, étourdi ou faible.
POINT AWAY DIRIJA ALEJADO DIRIGER LOIN
EXHAUST EL ESCAPE L’ECHAPPEMENT
3594-L-SF-A
C
UNLEADED FUEL ONLY. Minimum octane rating of 87. Maximum 10% ethanol.
GASOLINA REGULAR SOLAMENTE. 87 octanos como mínimo. Máximo de etanol de 10%.
ESSENCE SANS PLOMB SEULEMENT. Indice d’octane minimal de 87. Maximum 10 %
d’éthanol.
1110-L-OP-B
WARNING
ADVERTENCIA
D
DO NOT TOUCH!
Operation of this equipment may create sparks that can start ¡NO TOCAR! Los gases de
Exhaust gases, muffler fires around dry vegetation. A spark arrestor may be
escape, el silenciador y los
La operación de este equipo puede producir chispas que pueden provocar incendios alrededor de la vegetación seca. Un supresor de chispas puede que
and engine components required. The operator should contact local fire agencies for compnonentes del motor están sea necesario. El operador debe comunicarse con las agencias locales de
are extremely HOT and laws and regulations relating to fire prevention requirements. extremadamente CALIENTES y bomberos para las leyes y reglamentos relativos a los requisitos de prevención
cause burns.
If installed, clean every 100 hours or every season.
causan quemaduras.
de incendios. Si está instalado, limpie cada 100 horas o cada temporada.
CHAMPION POWER EQUIPMENT, INC. 12039 SMITH AVENUE SANTA FE SPRINGS, CA 90670 USA / É.-U. 1-877-338-0999
FREQUENCY (Hz) FRÉQUENCE (Hz)
RPM TR / MIN
60 3600
MAX AMBIENT TEMP. 104°F TEMP. AMBIANTE MAX. 40°C
H INSULATION CLASS
CLASSE D’ISOLATION
E
WWW.CHAMPIONPOWEREQUIPMENT.COM MADE IN VIETNAM / FABRIQUÉ AU VIETNAM
PHASE PHASE
1
MODEL MODÈLE
201156
POWER FACTOR FACTEUR DE PUISSANCE
1.0
GASOLINE WATTS WATTS D’ESSENCE
3650
SERIAL NO. N° DE SÉRIE
XXXXXXXXXXXX
AC VOLTS VOLTS C.A.
120
XXXX MANUFACTURE DATE
DATE DE FABRICATION
AC AMPS AMPÈRES C.A.
30.4
8
3414-L-PR-A 1291-L-SF-A
Side DESCRIPTION
Safety Symbols/ CO Danger
CO Shield® Action automatic shutoff *See CO Shield®
section
Fuel
Hot Surface
Dataplate
201156 – 3650W WIRELESS REMOTE START GENERATOR
IMPORTANT SAFETY INSTRUCTIONS
Safety Symbols
Some of the following symbols may be used on this product. Please study them
and learn their meaning. Proper interpretation of these symbols will allow you
to more safely operate the product.
SYMBOL
MEANING
Read Operator’s Manual. To reduce the risk of injury, user must read and understand operator’s manual before using this product.
Clearance. Keep all objects at least 5 feet (1.5m) from generator. Heat from the muffler and exhaust gas can ignite combustible objects.
Ground. Consult with local electrician to determine grounding requirements
before operation.
Electric Shock. Failure to use in dry conditions and to observe safe practices
can result in electric shock. Improper connections to a building can allow
current to backfeed into utility lines, creating an electrocution hazard. A
transfer switch must be used when connecting to a building.
Fire/Explosion. Fuel and its vapors are extremely flammable and explosive.
Fire or explosion can cause severe burns or death. Keep generator at least 5
feet (1.5m) from all objects to prevent combustion.
Hot Surface. To reduce the risk of injury or damage, avoid contact with any hot surface.
Open Flame Alert. Fuel and its vapors are extremely flammable and explosive. Keep fuel away from smoking, open flames, sparks, pilot lights, heat, and other ignition sources.
Wet Conditions Alert. Do not expose to rain or use in damp locations.
9
201156 – 3650W WIRELESS REMOTE START GENERATOR
IMPORTANT SAFETY INSTRUCTIONS
Operation Symbols
Some of the following symbols may be used on this product. Please study them
and learn their meaning. Proper interpretation of these symbols will allow you
to more safely operate the product.
SYMBOL
Start
MEANING
On
Stop or Off
Fuel Valve On/Off
Choke
Run
Ground Terminal
Battery On
Battery Off
Neutral Floating. Neutral circuit IS NOT electrically connected to the frame/
ground of the generator.
Circuit Breaker Reset: Push
SYMBOL
MEANING Locking Receptacle RV Ready Receptacle Wireless Pair
Gasoline Tank: Full
Gasoline Tank: Empty
High CO Warning. Move generator to an open, outdoor area. Move to fresh air
and get medical help if sick, dizzy or weak. CO Shield System Fault.
Electrical issue, end of life.
Hertz
Volts
Run time
10
201156 – 3650W WIRELESS REMOTE START GENERATOR
IMPORTANT SAFETY INSTRUCTIONS
Quick Start Label Symbols
Some of the following symbols may be used on this product. Please study them
and learn their meaning. Proper interpretation of these symbols will allow you
to more safely operate the product.
3411-L-OP-B
1
2
3
4
5
6
7
8
10W-30
1
2
3
Starting the Engine
DANGER
Move generator outside and far away from windows, doors and intake ventilation
covers.
1. Check oil level. Recommended oil is 10W-30.
2. Check gasoline level. When adding gasoline, use a minimum octane rating of
87 and an ethanol content of 10% or less by volume.
3. Turn the fuel valve to “ON” position. 4. Press ignition switch to the “ON”
position. 5. Move choke lever to “CHOKE” position. 6. Pull the recoil cord. 7.
Move the choke lever to “RUN” position. 8. Plug in desired device.
Stopping the Engine 1. Turn off and unplug all connected electrical loads. 2. Press the ignition switch to the “OFF” position. 3. Turn the fuel valve to the “OFF” position. Wireless and Electric Start See page 24 in “Operation” section
11
201156 – 3650W WIRELESS REMOTE START GENERATOR
CONTROLS AND FEATURES
CONTROLS AND FEATURES
Read this operator’s manual before operating your generator. Familiarize
yourself with the location and function of the controls and features. Save
this manual for future reference.
Generator
2 3 4
13 1
12
10 9
11
5 6
1. Fuel Cap Remove to add fuel. 2. Choke Used to start the engine (for
manual start only). 3. Fuel Valve Used to turn fuel supply on and off to
engine. 4. Air Filter Protects the engine by filtering dust and debris
from the intake air. 5. Never Flat Wheels 8 in. (20.3 cm) 6. Recoil Starter
Used to manually start the engine. 7. Oil Fill Cap/Dipstick Used to check
and fill oil level. 8. Battery Provides 12V DC power the starting system.
8 7
9. Control Panel See Control Panel section. 10. Gasoline Tank 4.7 gal.
(17.8 L) 11. Ground Terminal Consult an electrician for local grounding
regulations. 12. Folding Handle Used to move unit by lifting and rolling on
wheels. Do not use to lift or carry the unit. 13. Gasoline Gauge
12
201156 – 3650W WIRELESS REMOTE START GENERATOR
Control Panel
CONTROLS AND FEATURES
1. Ignition Switch Used to START or STOP the generator.
2. Battery Switch Enables/disables electric starting.
3. Intelligauge Four mode digital meter for displaying voltage, frequency,
run time, and total run time.
4. CO Shield® LED The CO Shield® technology monitors for accumulation of
poisonous carbon monoxide (CO) gas produced by engine exhaust when the
generator is running. If CO Shield® detects elevated levels of CO gas, it
automatically shuts off the engine.
- *See CO Shield section for more information
5. Circuit Breakers (Push Reset) Protects the generator against electrical overloads.
RECEPTACLES
120V AC, 30A Locking (NEMA L5-30R)
W A
May be used to supply electrical power for
operation of 120 Volt AC, 30 Amp, single phase,
60 Hz electrical loads.
120V AC, 30A RV (NEMA TT-30R)
t B
May be used to supply electrical power for
operation of 120 Volt AC, 30 Amp, single phase,
60 Hz electrical loads.
(2×) 120V AC, 20A (NEMA 5-20R)
C C
May be used to supply electrical power for
operation of 120 Volt AC, 20 Amp, single phase,
60 Hz electrical loads.
13
201156 – 3650W WIRELESS REMOTE START GENERATOR
Intelligauge
Four mode digital meter for displaying voltage, frequency, run time, and total
run time. Mutli-colored LED indicates CO shutoff or fault.
CONTROLS AND FEATURES
MODE
Voltage (V)
Example: 120 volts
Frequency (H) Example: 60.0 hertz
Run Time (R)
Example: 6 hours
Total Run Time Example: 16 hours
DESCRIPTION Output voltage of the generator.
Output frequency in hertz.
Run time of the generator for the current session.
Total run time of the generator since first operation.
14
201156 – 3650W WIRELESS REMOTE START GENERATOR
Wireless Remote Control
This generator is equipped with a wireless remote control system for starting
and stopping. The system consists of (5) main components:
1. Receiver Control Module (RCM)
2. Remote Key Fob
3. Battery Switch
4. Ignition Switch
5. Auto-Choke The Remote Control functions are enabled when:
1. The Ignition Switch is in the “ON” position, AND
2. The Battery Switch is in the “ON” position.
The Remote Control functions are disabled if either of the above conditions is
not met.
To start the generator wirelessly, press the “START” button on the Remote key
fob one time. The engine will attempt to start (6) times. The RCM controls the
Auto-Choke during each attempt to start. If the generator does not start, call
Champion Customer Care team for assistance at
1-877-338-0999.
To stop the generator wirelessly, press the “STOP” button on the Remote key
fob one time. Remote Control Power Consumption
While the Ignition Switch is in the “ON” position, the RCM is active and
waiting for a remote signal. This function requires electrical current from
the battery. If the Ignition Switch is left in the “ON” position for extended
periods (several weeks), the battery can be completely drained.
Moving the Ignition Switch to the “OFF” position disables the Remote
functions, but the RCM still consumes approximately 2 mA from the battery.
To prevent battery drain, press the Battery Switch to the “OFF” position. This
disconnects power to the RCM so there is no current draw on the battery.
Control Panel Load Management
When the generator initially starts wirelessly, no voltage is supplied to the
Control Panel for approximately 15 seconds. This allows the engine to reach
full speed before electrical loads are applied to the generator.
When the generator is stopped wirelessly, the voltage to the Control Panel is
immediately turned off. Then the engine stops approximately 5 seconds after
the “STOP” button on the Remote key fob is pressed. Turning the Control Panel
voltage off before the engine shutdown protects connected appliances from
being damaged by non-60 Hz voltage while the generator coasts to a stop.
CONTROLS AND FEATURES
The on/off voltage delay at startup and shut down only happen when the Remote
key fob is used. There is no voltage delay when the push-button electric start
or recoil cord method is used.
When the push-button electric start or recoil cord method is used, the
operator must be sure all electrical loads (appliances) are turned OFF during
startup and shutdown. Damage to the generator or the attached appliances can
be caused by starting or stopping the generator while appliances are plugged
in and turned ON.
FCC Statement
1. This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions:
1a. This device may not cause harmful interference.
1b. This device must accept any interference received, including interference
that may cause undesired operation.
2. Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
NOTICE
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
Consult dealer or an experienced radio/TV technician for help.
15
201156 – 3650W WIRELESS REMOTE START GENERATOR
Parts Included
Accessories Remote Key Fob ……………………………………………. 1 Engine Oil……………………………….. 16.9
fl. oz. (500 ml) Oil Funnel ………………………………………………….. 1
Assembly Parts Wheels 8 in. (20.3 cm) Never Flat Wheel (A) ……………………… 2 Wheel
hub cap (B) ………………………………………. 2 Roll Pin (C) ……………………………………………… 2 Large R-clip
(D) …………………………………………. 2 Engine Vibration Mounts Support Leg with Vibration
Mounts (E) …………………… 1 Flange Bolt (M8×16) (F) …………………………………. 2 Flange Lock Nut
(M8) (G)………………………………… 2 Folding Handle Handle (H)………………………………………………. 1 Short
Pin (I) …………………………………………….. 1 Small R-clip (J) …………………………………………. 1
Tools Needed
Wrench/Socket set (metric) Pliers
CONTROLS AND FEATURES
A B
C
E H
D F
G
I
J
16
201156 – 3650W WIRELESS REMOTE START GENERATOR
ASSEMBLY
Your generator requires some assembly. This unit ships from our factory
without oil. It must be properly serviced with fuel and oil before operation.
If you have any questions regarding the assembly of your generator, call our
Technical Support Team at
1-877-338-0999. Please have your serial
number and model number available.
Unpacking
1. Set the shipping carton on a solid, flat surface. 2. Remove everything
from the carton except the generator. 3. Carefully cut each corner of the box
from top to bottom. Fold
each side flat on the ground to provide a surface area to work with the
generator.
Remove Shipping Support Brackets
To protect the generator during shipping, support brackets have been installed
between the engine and frame. These brackets MUST BE REMOVED BEFORE adding oil
or gasoline to the generator.
NOTICE
DO NOT attempt to run generator without first removing the shipping support
brackets. Damage to the generator as a result of not removing the brackets
will void the warranty.
1. BEFORE filling the engine with oil or gasoline, tip the generator onto its
recoil end. Tip onto the flattened cardboard box the generator came in or
other protective surface so as to not scratch the frame.
2. Remove the bolts from the orange support brackets. Bolts and brackets can
be discarded.
3. Tip the generator upright.
ASSEMBLY
Install the Wheel Kit
CAUTION
The wheel kit is not intended for over-the-road use.
Install the Wheels 1. Before adding fuel and oil, tip the generator onto it’s
recoil
end. 2. Remove wheel hub cap (B) from wheel by inserting a small
screwdriver into the slot provided and pry upward. 3. Slide the roll pin (C)
through the wheel (A) from the outside. 4. Slide the roll pin through the
mount point on the frame. 5. Insert r-clip (D) into hole at end of roll pin.
6. Re-install hub cap on wheel. 7. Repeat to attach the second wheel.
C
B
D A
Install the Support Leg
1. Attach the support leg (E) to the generator frame with flange bolts (F)
and flange lock nuts (G).
2. Slowly tip the generator back down so that it rests on the wheels and
support Leg.
E
F G
17
201156 – 3650W WIRELESS REMOTE START GENERATOR
Install the Handle 1. Place the handle (H) inside the mounting channel on the
frame. 2. Slide short pin (I) through mounting channel and handle. 3. Insert
r-clip (J) through the hole on the end of short pin.
J
I
H
Connect the Battery
1. Cut cable tie on each side of battery connector. 2. Push two halves of
battery connector together tightly.
ASSEMBLY
NOTICE
The generator rotor has a sealed, pre-lubricated ball bearing that requires no
additional lubrication for the life of the bearing.
NOTICE
The recommended oil type for typical use is 10W-30 automotive oil. However,
using the listed conventional oils shown in the “Recommended Engine Oil Type”
chart may be used for typical use including the first 5 hours of the break-in
run time period of the engine. If running generator in extreme temperatures,
refer to the “Recommended Engine Oil Type” chart.
Recommended Engine Oil Type 10W-30
5W-30
10W-40
5W-30 Full Synthetic
°F -20
0
20 40 60 80 100 120
°C -28.9 -17.8 -6.7 4.4 15.6 26.7 37.8 48.9
Ambient temperature
1. Place the generator on a flat, level surface. 2. Remove oil fill
cap/dipstick to add oil. 3. Using a funnel, add up to 16.9 fl. oz. (500 ml) of
oil (included)
and replace oil fill cap/dipstick. DO NOT OVERFILL.
Add Engine Oil WARNING
DO NOT attempt to crank or start the engine before it has been properly filled
with the recommended type and amount of oil. Damage to the generator as a
result of failing to follow these instructions will void your warranty.
18
201156 – 3650W WIRELESS REMOTE START GENERATOR
4. Check engine oil level at every use and add as needed.
MAX OIL DIP STICK
NOTICE
Once oil has been added, a visual check should show oil about 1-2 threads from
running out of the fill hole. When using the dipstick to check oil level, DO
NOT screw in the dipstick while checking.
NOTICE
Check oil level often during the break-in period. Refer to the Maintenance
section for recommended service intervals.
CAUTION
This engine is equipped with a low oil shut-off and will stop when the oil
level in the crankcase falls below the threshold level.
NOTICE
The first 5 hours of run time are the break-in period for the unit. During the
break in period stay at or below 50% of the running watt rating and vary the
load occasionally to allow stator windings to heat and cool. Adjusting the
load will also cause engine speed to vary slightly and help seat piston rings.
After the 5 hour break-in period, change the oil.
NOTICE
Synthetic oil may be used after the 5 hour initial break-in period. Using
synthetic oil does not decrease the recommended oil change interval. Full
synthetic 5W-30 oil will aid in starting in cold ambient < 41º F (5º C)
temperatures.
ASSEMBLY
Add Fuel
DANGER
Gasoline vapors are highly flammable and extremely explosive.
DO NOT light or smoke cigarettes. Fire or explosion can cause severe burns or
death. Only fill or drain fuel outdoors in a well-ventilated area. DO NOT pump
gasoline directly into the generator. Use an approved container to transfer
the fuel to the generator. Never use a gasoline container, gasoline tank, or
any other fuel item that is broken, cut, torn or damaged. DO NOT overfill the
gasoline tank. Always keep fuel away from sparks, open flames, pilot lights,
heat and other sources of ignition.
Use clean, fresh, regular unleaded gasoline with a minimum octane rating of 87
and an ethanol content of 10% or less by volume. y b c DO NOT mix oil with
gasoline. 1. Remove the gasoline cap. 2. Slowly add gasoline to the tank. Tank
is full when gasoline
reaches red circle on screen. DO NOT OVERFILL. Gasoline can expand after
filling. A minimum of ¼ in. (6.4 mm) of space left in the tank is required for
gasoline expansion, although more than ¼ in. (6.4 mm) is recommended. Gasoline
can be forced out of the tank as a result of expansion if overfilled, and can
affect the stable running condition of the generator.
19
201156 – 3650W WIRELESS REMOTE START GENERATOR
3. The approximate fuel level is shown on the fuel gauge on top of the fuel
tank.
Empty
Full
4. Screw on the gasoline cap and wipe away any spilled fuel.
CAUTION
Use unleaded gasoline with a minimum octane rating of 87 and an ethanol
content of 10% or less by volume.
DO NOT light cigarettes or smoke when filling the tank. DO NOT mix oil and
gasoline. DO NOT overfill the tank. Fill tank to approximately ¼ in. (6.4 mm)
below the top of the tank to allow for gasoline expansion. DO NOT pump
gasoline directly into the generator at the pump. Use an approved fuel
container to transfer the gasoline to the generator. DO NOT fill tank indoors.
DO NOT fill tank when the engine is running or hot.
WARNING
Pouring gasoline too fast through the fuel screen may result in gasoline
splashing over the generator and operator while filling.
ASSEMBLY
NOTICE
The generator engine works well with 10% or less ethanol blended gasoline.
When using ethanol-gasoline blends there are some issues worth noting:
Ethanol-gasoline blends can absorb more water than gasoline alone.
These ethanol blends can eventually separate, leaving water or a watery goo
in the tank, fuel valve and carburetor. The compromised gasoline can be drawn
into the carburetor and cause damage to the engine and/or create potential
hazards.
If a fuel stabilizer is used, confirm that it is formulated to work with
ethanol-gasoline blends.
Any damages or hazards caused by using ethanol blended gasoline higher than
10% by volume, improperly stored gasoline, and/or improperly formulated
stabilizers, are not covered by manufacturer’s warranty.
It is advisable to always shut off the gasoline supply and run the engine to
starvation after each use. See Storage instructions for extended non-use.
Grounding
Your generator must be properly connected to an appropriate ground to help
prevent electric shock.
WARNING
Failure to properly ground the generator can result in electric shock.
A ground terminal connected to the frame of the generator has been provided
(see Controls and Features for terminal location). For remote grounding,
connect a length of heavy gauge (12 AWG minimum) copper wire between the
generator ground terminal and a copper rod driven into the ground. We strongly
recommend that you consult with a qualified electrician to ensure compliance
with local electrical codes. Neutral Floating* Neutral circuit IS NOT
electrically connected to the frame/
ground of the generator.
The generator (stator winding) is isolated from the frame and from the AC
receptacle ground pin.
Electrical devices that require a grounded receptacle pin connection will
not function if the receptacle ground pin is not functional.
20
201156 – 3650W WIRELESS REMOTE START GENERATOR
Neutral Bonded to Frame* Neutral circuit IS electrically connected to the
frame/ground of
the generator. The generator system ground connects lower frame cross-
member below the alternator. The system ground is connected to the AC neutral
wire.
- See your Specifications section for specified type of grounding.
OPERATION
CO Shield® – Carbon Monoxide (CO) Detection and Auto-shutoff System
CO Shield® technology monitors the accumulation of carbon monoxide (CO), a poisonous gas produced by engine exhaust when the generator is running. If CO Shield® detects unsafe elevated levels of CO gas, it automatically shuts off the engine. CO SHIELD IS NOT A SUBSTITUTE FOR AN INDOOR CARBON MONOXIDE ALARM OR FOR INDOOR OPERATION. DO NOT allow engine exhaust fumes to enter a confined area through windows, doors, vents or other openings. Generators must ALWAYS be used outdoors, far away from occupied buildings with engine exhaust pointed away from people and buildings.
OPERATION
In the event of an engine shut off, when you approach the generator to
investigate, a blinking red LED light in the CO Shield® area provides
notification that the generator shut off due to an accumulating CO hazard. The
red LED light will blink for at least five (5) minutes after an engine shut
off event.
AUTOMATIC SHUTOFF SEE ACTION LABEL
APAGADO AUTOMÁTICO VEA ETIQUETA DE ACCIÓN
SERVICE REALICE UN SERVICIO
Move the generator far away to an open, outdoor area and point the exhaust
away from people and buildings. Once relocated to a safe area, the generator
can be restarted, and the proper electrical connections made. Introduce fresh
air and ventilate the location where the generator shut off.
When restarting, the red and yellow LED will blink ten (10) times
simultaneously to indicate the LED is working.
NOTICE
This blinking LED light does not indicate CO Shield® is working, as CO Shield®
is working at all times when the generator is running. Also, the LED light
will not blink (10) times if the generator was restarted within 1 minute after
it was manually shut off. This does not occur if generator shut off from a
high CO event.
If misused and operated in an unapproved and unsafe location that results in the accumulation of poisonous CO gas inside an enclosed or partially enclosed space, for example a house, garage or a garage with the door partially open, CO Shield® will automatically shut off the generator and then will illuminate a blinking red LED light. Read the action label for next steps.
ACTION LABEL ETIQUETA DE ACCIÓN ÉTIQUETTE D’ACTION
AUTOMATIC SHUTOFF YOU MUST: APAGADO AUTOMÁTICO USTED DEBE: ARRÊT AUTOMATIQUE VOUS DEVEZ :
Move generator to an open, outdoor area. Point exhaust away. Don’t run generators in enclosed areas (e.g. not in house or garage).
Move to fresh air and get medical help if sick, dizzy or
weak.
Mover el generador a un área abierta a la intemperie. Apunte el escape alejado.
No corra los generadores en áreas cerradas (ej. no en una casa o garaje).
Mueva al aire fresco y obtenga
asistencia medica si está
Déplacer le générateur vers un espace
enfermo, mareado, o débil.
extérieur en plein air. Garder l’échappement
loin. Ne pas faire fonctionner les générateurs Aller à l’air frais et obtenir
dans un espace clos (ex., pas dans une maison de l’aide médicale si
ou un garage).
malade, étourdi ou faible.
POINT AWAY DIRIJA ALEJADO DIRIGER LOIN
EXHAUST EL ESCAPE L’ECHAPPEMENT
3594-L-SF-A
If CO Shield® system experiences a fault and no longer provides protection, the generator is shutoff automatically and the yellow LED light will blink for at least five (5) minutes to notify you of the fault.
AUTOMATIC SHUTOFF SEE ACTION LABEL
APAGADO AUTOMÁTICO VEA ETIQUETA DE ACCIÓN
SERVICE REALICE UN SERVICIO
Call our Technical Support Team at 1-877-338-0999 for repair. The generator can be restarted, but will continue to shutoff.
21
201156 – 3650W WIRELESS REMOTE START GENERATOR
NOTICE
CO Shield® will detect the accumulation of carbon monoxide (CO) from other
fuel burning sources such as engine powered equipment, or propane heaters used
in the area of operation. If another generator is used and the exhaust stream
is pointed at a CO Shield® equipped generator, the CO Shield® may initiate a
shutoff due to rising carbon monoxide (CO) levels. This is not a fault.
Poisonous carbon monoxide (CO) has been detected. You must take action to move
and direct the generator exhaust stream to better disperse carbon monoxide
(CO) far away from people or buildings.
DANGER
Tampering with the CO Shield® system will result in a hazardous condition and
will void your warranty. Removing the CO Shield® module will not allow the
generator to start.
OPERATION
Generator Location
WARNING
NEVER operate the generator inside any building, garage, basement, crawlspace,
shed, enclosure or compartment, including a generator compartment of a
recreational vehicle.
NEVER operate or start the generator in the back of an SUV, camper, trailer,
truck bed (regular sides, flat or other configuration), under staircases,
stairwells, next to walls or buildings or in any other location that will not
allow for adequate cooling of the generator or for the proper exit of the
exhaust flow from the muffler system.
DO NOT operate or store the generator in wet weather conditions such as rain
or snow. Using a generator in wet conditions could result in serious injury or
death due to electrocution.
In some state’s generators may be required to be registered with the local
utility company when used at construction sites and may be subject to
additional rules and regulations, consult your local municipal authority.
Generators should always be operated on a flat, level surface at all times
(even when not in operation).
Generators must have a minimum of 5 feet (1.5 m) of clearance from all
combustible material.
Generators must also have a minimum of 3 feet (91.4 cm) of air flow clearance
on all sides to allow for adequate performance cooling, maintenance and
servicing.
Always place the generator in a well-ventilated area. NEVER place the
generator near air intake vents or where exhaust fumes could be drawn into
occupied or confined spaces.
Always carefully consider wind and air currents when positioning generator.
Always allow generators to properly cool before transport or for storage
purposes.
Failure to follow proper safety precautions may result in personal injury,
damage to the generator and void the manufacturer’s warranty.
WARNING
During operation the muffler and exhaust fumes will become hot. If adequate
cooling and breathing space are not supplied, or if the generator is blocked
or enclosed, temperatures can become extremely heated and may lead to fire.
22
201156 – 3650W WIRELESS REMOTE START GENERATOR
WARNING
Do not expose to rain or use in damp locations. Keep all objects a minimum of
5 feet (1.5m) away from the generator at all times. Heat from the muffler
surface and exhaust gas stream can ignite combustible materials.
WARNING
If you must operate in rain or damp locations, DO NOT operate without proper
protection of the electrical components.
Use of a safety canopy that is fire retardant and will provide proper air
ventilation for the engine exhaust gas stream may be used. Visit
championpowerequipment.com or call to find your Storm Shield cover.
Surge Protection
Electronic devices, including computers and many programmable appliances use
components that are designed to operate within a narrow voltage range and may
be affected by momentary voltage fluctuations. While there is no way to
prevent voltage fluctuations, you can take steps to protect sensitive
electronic equipment. Install UL1449, CSA-listed, plug-in surge suppressors
on the
outlets feeding your sensitive equipment. Surge suppressors come in single- or
multi-outlet styles. They’re designed to protect against virtually all short-
duration voltage fluctuations.
Wireless Set Button
The wireless set button is a feature that lets the user synchronize the remote
key fob to the generator. Up to two remote key fobs can be synchronized to the
generator at a time. Follow the proceeding steps to reset a remote or
synchronize two remotes: 1. Turn the ignition switch to the “ON” position.
OPERATION
2. Turn the battery switch to the “ON” position.
3. Push and hold the wireless set button found on the side of the control
panel for approximately three seconds until the red light turns on.
4. Push and release the STOP $ button on the remote key fob. The red light
blinks once to erase the remote program.
5. Push and release the START a button on the remote key fob. The red light blinks once to program the remote.
23
201156 – 3650W WIRELESS REMOTE START GENERATOR
6. Push and hold the programming button approximately three seconds until the
red light turns off.
OPERATION
Wireless Remote Start Wireless remote starting is only possible within 80 feet
of the generator. DO NOT attempt to adjust the choke. The remote system will
automatically close and open the choke. 1. Push the battery switch to the “ON”
position.
7. Follow the remote START and STOP instructions to verify the remote(s) are
working properly.
NOTICE
Two remote key fobs can be synchronized to the generator at one time.
NOTICE
Changing a remote key fob battery may not require the user to reset the
remote. If remote does not function after changing the battery, proceed with
Wireless Set Button instructions.
2. Push the ignition switch to the “ON” position.
Starting the Engine
1. Make certain the generator is on a flat, level surface. 2. Turn the
gasoline fuel valve to the “ON” position.
3. Press and release the “START” button on the remote key fob. DO NOT hold the button down, only press the button once. The engine will attempt to start six times.
24
201156 – 3650W WIRELESS REMOTE START GENERATOR
Electric Start DO NOT attempt to adjust the choke. The remote system will
automatically close and open the choke. 1. Push the battery switch to the “ON”
position.
OPERATION
Manual Start 1. Disconnect all electrical loads from the generator. Never
start or stop the generator manually with electrical devices plugged in or
turned on. 2. Push the ignition switch to the “ON” position.
2. Press and hold the ignition switch to the “START” position. Release as the engine begins to start. If the engine fails to start within five seconds, release the switch and wait at least ten seconds before attempting to start the engine again.
3. Move the choke lever to the “CHOKE” position.
3a. For restarting a warm engine, move the choke lever to 75% of the “CHOKE”
position.
CAUTION
If the ignition switch is held down in the “START” position longer than 5
seconds it could damage the starter.
4. Pull the recoil cord slowly until resistance is felt and then pull rapidly.
25
201156 – 3650W WIRELESS REMOTE START GENERATOR
5. Do not over-choke. As soon as engine starts, move the choke lever to the
“RUN” position over a 2-5 second duration.
OPERATION
NOTICE
For Wireless and Electric Start only: A safety feature is provided which
delays the electrical power availability during starting mode. The delay lasts
for approximately 15 seconds. The delay is provided to prevent damage to the
generator if electrical loads are inadvertently turned on during engine
startup.
NOTICE
Keep choke lever in “CHOKE” position for only 1 pull of the recoil cord. After
first pull, move choke lever to “RUN” position for up to 3 pulls of the recoil
cord. Too much choke leads to spark plug fouling/engine flooding due to lack
of incoming air. This will cause the engine not to start.
NOTICE
For gasoline restarts with hot engine in hot ambient temperature > 86°F
(30°C), keep choke lever in 75% of the “CHOKE” position for only 1 pull of the
recoil cord. After first pull, move choke lever to “RUN” position for up to 3
pulls of the recoil cord. Too much choke leads to spark plug fouling/ engine
flooding due to lack of incoming air. This will cause the engine not to start.
NOTICE
For gasoline starting in cold ambient temperature < 59°F (15°C), the choke
lever must be in 100% of “CHOKE” position for manual start procedures. Do not
over-choke. As soon as engine starts, gradually move the choke lever to the
“RUN” position over a 2-5 second duration.
NOTICE
If the engine starts but does not continue to run make certain that the
generator is on a flat, level surface. This engine is equipped with a low oil
sensor that will prevent the engine from running when the oil level falls
below a critical threshold.
Battery
NOTICE
When the battery switch is in the “ON” position, the switch will light up if
the battery is sending out a charge. If the switch does not light up while in
the “ON” position, check that the battery connection is still good.
NOTICE
The supplied 12V battery does re-charge while the engine is running and the
battery switch is turned ON, but it is also recommended that the battery be
fully charged at least once per month or maintained with a trickle charger or
battery maintainer (not included).
Connecting Electrical Loads
Let the engine stabilize and warm up for a few minutes after starting. Plug in
and turn on the desired 120 or 240 (if applicable) Volt AC single phase, 60 Hz
electrical loads. DO NOT connect 3-phase loads to the generator. DO NOT
overload the generator. Use only a high quality, insulated, compatible
(3-wire or
4-wire) grounded cord set rated equal to or greater (volts and amps) than the
receptacle plugging into.
26
201156 – 3650W WIRELESS REMOTE START GENERATOR
WARNING
Always remember to plug your appliances directly into the generator and do not
plug the generator power cord into any electrical outlet or connect to the
circuit breaker panel in your home. Connecting a generator to your home’s
electric utility company’s power lines, or to another power source, called
`backfeeding’ is a dangerous practice that is illegal in many states and
municipalities.
This action if done incorrectly could damage your generator, appliances and
could cause serious injury or death to you or a utility worker when attempting
to restore power during an outage occurrence in the neighborhood who may then
unexpectedly encounter high voltage on the utility line and suffer a fatal
shock.
Whether injuries occur or not, if installed incorrectly and not to applicable
laws and codes, you may be subject to fines or the utility company may
disconnect your home power should this practice be found in your home.
If the generator will be connected to a building electrical system, those
connections must isolate the generator power from the utility power. You are
responsible for ensuring your generator’s electricity does not backfeed into
the electric utility power lines. These connections must comply with all
applicable laws and codes Consult your local utility company or a qualified
electrician to properly install this connection.
Do Not Overload Generator
Capacity
Follow these simple steps to calculate the running and starting watts
necessary for your purposes:
1. Select the electrical devices you plan on running at the same time.
2. Total the running watts of these items. This is the amount of power you
need to keep your items running.
3. Identify the highest starting wattage of all devices identified in step 1.
Add this number to the number calculated in step 2. Starting wattage is the
surge of power needed to start some electric driven equipment. Following the
steps listed under “Power Management” will guarantee that only one device will
be starting at a time.
OPERATION
Power Management Use the following formula to convert voltage and amperage to
watts:
Volts × Amps = Watts To prolong the life of your generator and attached
devices, follow these steps to add electrical load: 1. Start the generator
with no electrical load attached. 2. Allow the engine to run for several
minutes to get up to
temperature. 3. Make sure all circuit breakers are set to the run position. 4.
Plug in and turn on the first item. It is best to attach the item
with the largest load first. 5. Allow the engine to stabilize. 6. Plug in and
turn on the next item. 7. Allow the engine to stabilize. 8. Repeat steps 5-6
for each additional item.
NOTICE
Never exceed the specified capacity when adding loads to the generator.
Stopping the Engine
Remote Stop 1. Turn off all electrical connected loads. Never start or stop
the
generator with electrical devices turned on. 2. Let the generator run at no-
load for several minutes to
stabilize internal temperatures of the engine and generator. 3. Press the
“STOP” button on the remote.
NOTICE
Engine will shut off but the battery switch, ignition switch, and fuel valve
will remain in the “ON” position waiting for the next start instruction.
27
201156 – 3650W WIRELESS REMOTE START GENERATOR
To completely shut down the generator, make sure the ignition switch, battery
switch, and fuel valve are in the “OFF” position when the generator will not
be used for an extended period of time.
NOTICE
Battery power is drawn while the generator is in standby mode (battery switch
ON). Do not leave generator in standby mode for an extended period of time or
the battery will be completely drained and the wireless remote and electric
start feature will no longer function.
Manual Stop 1. Turn off and unplug all electrical connected loads. Never start
or stop the generator with electrical devices plugged in or turned on. 2. Let
the generator run at no-load for several minutes to stabilize internal
temperatures of the engine and generator. 3. Press the ignition switch to the
“OFF” position.
5. Turn the fuel valve to the “OFF” position.
OPERATION
Important: Always ensure that the fuel valve, the ignition switch, and the
battery switch are in the “OFF” position when the generator will not be used
for an extended period of time.
NOTICE
If the engine will not be used for a period of two (2) weeks or longer, please
see the Storage section for proper engine and fuel storage.
4. If generator was started electrically, press the battery switch to the “OFF” position.
Moving the Generator
CAUTION
NEVER lift or carry the generator using the folding handle. NEVER tilt
sideways while moving the generator. ALWAYS place the generator on its
wheels in the upright
position. ALWAYS turn the generator off and ensure the fuel valve is
closed. ALWAYS make sure engine and muffler are cooled down
before the generator can be handled safely (typically 15-30 minutes).
WARNING
The folding handle is not long enough to hold and walk with a full stride when
moving the generator. Always side step as you walk to avoid injury to your
heels and/or feet. Failure to follow these instructions could result in
personal injury or damage to the generator.
1. Begin by raising the folding handle, found on opposite side of wheels.
2. Using the handle, tilt the end of the generator slightly off the ground
until balanced on the wheels.
28
201156 – 3650W WIRELESS REMOTE START GENERATOR
3. While maintaining balance, roll the generator to the desired location.
MAINTENANCE
MAINTENANCE
Make certain that the generator is kept clean and stored properly. Only
operate the unit on a flat, level surface in a clean, dry operating
environment. DO NOT expose the unit to extreme conditions, excessive dust,
dirt, moisture or corrosive vapors.
WARNING
Never operate a damaged or defective generator.
WARNING
Improper maintenance will void your warranty.
Operation at High Altitude
NOTICE
The density of air at high altitudes is lower than at sea level. Engine power
is reduced as the air mass and air-fuel ratio decrease. Engine power and
generator output will be reduced approximately 3½% for every 1000 ft. of
elevation above sea level. At high altitudes increased exhaust emissions can
also result due to the increased enrichment of the air fuel ratio. Other high
altitude issues can include hard starting, increased fuel consumption and
spark plug fouling.
To alleviate high altitude issues other than the natural power loss, CPE can
provide a high altitude carburetor main jet. The alternative main jet and
installation instructions can be obtained by contacting our Technical Support
Team. Installation instructions are also available in the Technical Bulletin
area of the CPE website.
The part number and recommended minimum altitude for the application of the
high altitude carburetor main jet is listed in the following table.
In order to select the correct high altitude main jet it is necessary to
identify the carburetor model. For this purpose, a code is stamped on the side
of the carburetor. Select the correct high altitude jet part number
corresponding to the carburetor code found on your particular carburetor.
Carb. Code High Alt. Jet Part Number Min. Altitude
16100Z2M041000M0
16161-Z151610-00A3 16161-Z151410-00A0
3000-6000 ft. (914.4 – 1828.8 m)
6000-8000 ft. (1828.8 – 2438.4 m)
WARNING
For Emission control devices and systems, read and understand your
responsibilities for service as stated in the Emission Control Warranty
Statement of this manual.
The owner/operator is responsible for all periodic maintenance. Complete all
scheduled maintenance in a timely manner. Correct any issue before operating
the generator. For service or parts assistance, contact our Technical Support
Team at 1-877-338-0999.
Cleaning the Generator
CAUTION
DO NOT spray generator directly with water.
Water can enter the generator through the cooling slots and damage the
generator windings. It can also contaminate the fuel system.
1. Use a damp cloth to clean exterior surfaces of the generator. 2. Use a
soft bristle brush to remove dirt and oil. 3. Use an air compressor (25 PSI)
to clear dirt and debris from
the generator. 4. Inspect all air vents and cooling slots to ensure that they
are
clean and unobstructed. To prevent accidental starting, remove and ground the
spark plug wire before performing any service.
Operation using the alternative main jet at elevations lower than the
recommended minimum altitude can damage the engine. For operation at lower
elevations, the originally supplied standard main jet must be used. Operating
the engine with the wrong engine configuration at a given altitude may
increase its emissions and decrease fuel efficiency and performance.
29
201156 – 3650W WIRELESS REMOTE START GENERATOR
Changing the Engine Oil
Change oil when the engine is warm. Refer to the oil specification to select
the proper grade for your operating environment. 1. Remove the oil drain bolt
with a 10 mm socket
(not included) and extension.
MAINTENANCE
Cleaning and Adjusting the Spark Plug
1. Remove the spark plug cable from the spark plug. 2. Use a spark plug
socket tool (not included), or a
13/16 in. (21 mm) socket (not included) to remove the plug.
DRAIN BOLT
2. Allow the oil to drain completely into an appropriate container.
3. Inspect the electrode on the plug. It must be clean and not worn to
produce the spark required for ignition.
4. Make certain the spark plug gap is 0.028-0.031 in. (0.7-0.8 mm).
SPARK PLUG GAP
3. Replace the oil drain bolt. 4. Add oil according to Add Engine Oil in
Assembly section.
DO NOT OVERFILL. Oil not included for routine maintenance. 5. Dispose of used
oil at an approved waste management
facility.
NOTICE
Once oil has been added, a visual check should show oil about 1-2 threads from
running out of the fill hole. If using the dipstick to check oil level, DO NOT
screw in the dipstick while checking.
5. Refer to the spark plug types in Specifications when replacing the plug.
6. Firmly re-install the plug.
7. Attach the spark plug cable to the spark plug.
Cleaning the Air Filter
1. Unscrew the cover holding the air filter to the assembly by turning the
fastener counterclockwise.
30
201156 – 3650W WIRELESS REMOTE START GENERATOR
2. Remove the foam element. 3. Wash in liquid detergent and water. Squeeze
thoroughly dry in
a clean cloth. 4. Saturate in clean engine oil. 5. Squeeze in a clean,
absorbent cloth to remove all excess oil. 6. Place the filter in the assembly.
7. Reattach the air filter cover and tighten the fastener by
turning clockwise.
Cleaning the Spark Arrestor
1. Allow the engine to cool completely before servicing the spark arrestor.
2. Remove the two screws holding the cover plate which retains the spark
arrestor to the muffler.
3. Remove the spark arrestor screen. 4. Carefully remove the carbon deposits
from the spark arrestor
screen with a wire brush.
MAINTENANCE
Adjusting the Governor
WARNING
Tampering with the factory set governor will void your warranty.
The air-fuel mixture is not adjustable. Tampering with the governor can damage
your generator and your electrical devices and will void your warranty.
Contact our Technical Support Team at
1-877-338-0999 for all other service
and/or adjustment needs.
Generator Battery
Your generator is equipped with an automatic battery charging circuit that
charges the battery while the engine is running. The battery will maintain a
proper charge if the unit is used on a regular basis (about once every two
weeks). If it is used less frequently, the battery should be connected to a
trickle charger or battery maintainer (not included) to keep the battery
properly charged.
Maximum charging rate should not exceed 1.5 amps. Follow the instructions
included with the battery charger. The battery should be fully charged at
least once per month. If the battery is not able to start the engine, it can
be started by manually pulling the engine recoil cord. If the battery voltage
is extremely low, the charging circuit may not be able to re-charge the
battery. In this case, the battery must be connected to a standard automotive
style battery charger for re-charging before it can be used. Disconnect the
Battery
1. Pull two halves of battery connector apart.
5. Replace the spark arrestor if it is damaged. 6. Position the spark
arrestor on the muffler and attach with the
screws removed in step 2.
CAUTION
Failure to clean the spark arrestor will result in poor engine performance.
NOTICE
Federal and local laws and administrative requirements indicate when and where
spark arrestors are required. When ordered, spark arrestors are required for
operation of this generator in National Forest lands. In California, this
generator must not be used on any forest-covered land, brush-covered land, or
grass-covered land unless the engine is equipped with a spark arrestor.
Charge the Battery
For a generator equipped with batteries for electric starting, proper battery
maintenance and storage should be followed. A trickle charger or battery
maintainer should be used to charge the battery while the generator is in
storage. Maximum charging rate should not exceed 1.5 amps. Follow the
instructions included with the trickle charger or battery maintainer. The
battery should be fully charged at least once per month.
31
201156 – 3650W WIRELESS REMOTE START GENERATOR
Remote Key Fob Battery NOTICE
Always purchase the correct size and grade of battery most suitable for the
intended use.
Clean the battery contacts and also those of the device prior to battery
installation.
Remove batteries from equipment which is not to be used for an extended
period of time.
Remove batteries if consumed or if product is to be left unused for a long
time.
1. Remove the remote key fob from the key ring. 2. Remove the screw with a
Phillips screwdriver (not included)
by turning counter clockwise. 3. Pry the two halves of the remote key fob
apart slightly at the
key ring end. 4. Separate the two halves of the remote key fob by sliding the
back side of the remote key fob up toward the key ring end.
5. Carefully remove the circuit board to locate and replace the CR2016
battery.
6. Reverse the above instructions to reassemble the remote key fob.
MAINTENANCE
Maintenance Schedule
Follow the service intervals indicated in the following maintenance schedule.
Service your generator more frequently when operating in adverse conditions.
Contact our Technical Support Team at
1-877-338-0999 to locate the nearest
CPE certified service dealer for your generator or engine maintenance needs.
EVERY 8 HOURS OR PRIOR TO EACH USE Check oil level Clean around air intake and
muffler
FIRST 5 HOURS (BREAK IN) Change oil
EVERY 50 HOURS OR ANNUALLY Clean air filter Change oil if operating under
heavy load or in hot
environments
EVERY 100 HOURS OR ANNUALLY Change oil Clean/adjust spark plug Clean spark
arrestor Clean fuel valve filter
EVERY 250 HOURS Clean combustion chamber Check/adjust valve clearance
EVERY 3 YEARS Replace fuel line
- To be performed by knowledgeable, experienced owners or CPE certified service centers.
32
201156 – 3650W WIRELESS REMOTE START GENERATOR
STORAGE
WARNING
To avoid accidental or unintended ignition of your generator during periods of
storage, the following precautions should be followed: When storing the
generator make sure the engine switch
and fuel valve are set to the “OFF” position.
STORAGE
Short Term Storage (up to 30 days)
Ethanol blended gasoline may gum up and clog the carburetor if the generator
is not run or carburetor drained within 4 weeks. 1. Be sure all appliances are
disconnected from the generator. 2. Start the generator as instructed in
Starting the Engine
section. 3. Turn the fuel valve to the “OFF” position. 4. Let the engine run
until fuel starvation has stopped the
engine. This usually takes a few minutes. 5. Move the engine switch to the
“OFF” position.
Mid Term Storage (30 days 1 year)
Ethanol blended gasoline in the tank has a maximum shelf life of up to 1 year
with the addition of a properly formulated fuel stabilizer and stored in a
cool, dry place. 1. Be sure all appliances are disconnected from the
generator. 2. Add a properly formulated fuel stabilizer to the gasoline tank.
3. Turn the fuel valve to the “ON” position. 4. Start and run the generator
for 10 minutes so the treated
gasoline cycles through the fuel system. 5. Option 1: Drain Gasoline from
Carburetor
5a. Turn engine switch to the “OFF” position and allow generator to cool
completely before continuing.
5b. Turn the fuel valve to the “OFF”. 5c. Use the drain bolt on the carburetor
to empty any
excess gasoline from the carburetor into an appropriate container. Use a
funnel (and appropriate hose if necessary) under the carburetor drain bolt to
avoid spillage.
5d. When gasoline stops flowing from the carburetor, replace and tighten the
carburetor drain bolt and be sure to properly dispose of the drained gasoline
according to local regulations or guidelines.
6. Option 2: Run Dry
6a. With the generator running, turn the fuel valve to the “OFF” position and
allow the generator to run until the engine stops from complete fuel
starvation. This may take a few minutes.
6b. Turn engine switch to the “OFF” position and allow generator to cool
completely before continuing.
7. Remove the spark plug cap and spark plug and pour about a tablespoon of
oil into the cylinder.
8. Pull the recoil cord slowly to crank the engine to distribute the oil and
lubricate the cylinder.
9. Install the spark plug and spark plug cap.
10. Clean the generator according to Cleaning the Generator.
11. Store the generator in a cool, dry place out of direct sunlight.
Long Term Storage (over 1 year)
For storage over 1 year, the gasoline tank and carburetor must be completely
drained of gasoline.
1. The generator is to be OFF and all appliances disconnected.
2. Turn the fuel valve to the “ON” position.
3. Use the drain bolt on the carburetor to empty any excess gasoline from the
gasoline tank and carburetor into an appropriate container. Use a funnel (and
appropriate hose if necessary) under the carburetor drain bolt to avoid
spillage.
4. When gasoline stops flowing from the carburetor, replace and tighten the
carburetor drain bolt and be sure to properly dispose of the drained gasoline
according to local regulations or guidelines.
5. Turn the fuel valve to the “OFF” position.
6. Follow steps 7-11 according to Mid Term Storage.
33
201156 – 3650W WIRELESS REMOTE START GENERATOR
Removing from Storage
NOTICE
If the generator has been improperly stored for a period longer than 30 days
with ethanol blended gasoline in the gasoline tank and/or carburetor, all fuel
must be drained and the carburetor must be thoroughly cleaned of ethanol build
up. This process involves technically advanced tasks. For assistance please
call our Technical Support Team at
1-877-338-0999. If the gasoline tank
and carburetor were properly emptied of all ethanol blended gasoline prior to
the generator being stored, follow the below steps when removing from storage.
1. Be sure the engine switch is in the “OFF” position. 2. Add gasoline to the
generator according to Add Fuel. 3. Turn the fuel valve to the “ON” position.
4. After 5 minutes check the carburetor and air filter areas for
any leaking gasoline. If any leaks are found, the carburetor will need to be
disassembled and cleaned or replaced. If no gasoline leaks are found, turn the
fuel valve to the “OFF” position. 5. Check engine oil level and add clean,
fresh oil if needed. See Oil Specifications for proper oil type. 6. Check and
clear air filter of any obstructions such as bugs or cobwebs. If necessary,
clean air filter according to Cleaning the Air Filter. 7. Start the generator
according to Starting the Engine.
STORAGE
34
201156 – 3650W WIRELESS REMOTE START GENERATOR
SPECIFICATIONS
Generator Specifications
Generator Model ……………………………………. 201156 Start Type ………………………….Wireless,
Electric, Manual Watts (Starting/Running) ………………………… 4550/3650 AC
Volts…………………………………………………. 120 AC Amps @ 120V (Running) …………………………….. 30.4
Frequency …………………………………………….. 60 Hz Phase ………………………………………………… Single Grounding
Type………………………………. Neutral Floating Weight ……………………………………… 112.4 lb. (51 kg)
Length …………………………………….. 24.4 in. (62.1 cm) Width …………………………………….. 23.9 in.
(60.8 cm) Height……………………………………… 22.5 in. (57.1 cm)
Engine Specifications
Model ………………………………………………… R224P Displacement …………………………………………. 224 cc
Type…………………………………………… 4-Stroke OHV Spark Plug OEM Type……………………………………………..
F6RTC Replacement Type…………………. NGK BPR6ES or equivalent Gap
…………………………….0.028-0.031 in. (0.7-0.8 mm) Valve Intake Clearance ……………
0.0039-0.0059 in. (0.1-0.15 mm) Exhaust Clearance …………. 0.0059-0.0079 in.
(0.15-0.2 mm)
NOTICE
A technical bulletin regarding valve adjustment procedures is available at
www.championpowerequipment.com.
SPECIFICATIONS
Oil Specifications
DO NOT OVERFILL. Type…………………………………….. *See following chart Capacity
………………………………… 16.9 fl. oz. (500 ml)
Recommended Engine Oil Type 10W-30
5W-30
10W-40
5W-30 Full Synthetic
°F -20
0
20 40 60 80 100 120
°C -28.9 -17.8 -6.7 4.4 15.6 26.7 37.8 48.9
Ambient temperature
NOTICE
Temperature will affect engine oil and engine performance. Change the type of
engine oil used based on temperature shown in the “Recommended Engine Oil
Type” table.
Fuel Specifications
Use unleaded gasoline with a minimum octane rating of 87 and an ethanol
content of 10% or less by volume. DO NOT USE E15 or E85. DO NOT OVERFILL.
Gasoline Capacity ……………………………. 4.7 gal. (17.8 L)
Battery Specifications
Type………………….. Rechargeable, Non-Spillable Lead Acid Volts DC
…………………………………………………. 12 Capacity ………………………………………… …….. 9 Ah
Temperature Specifications
Starting Temperature Range (°F/°C) ……….. 5 to 104/-15 to 40
NOTICE
An important message about temperature: Your product is designed and rated for
continuous operation at ambient temperatures up to 104°F (40°C). When needed,
it may be operated at temperatures ranging from 5°F (-15°C) to 122°F (50°C)
for short periods of time. If exposed to temperatures outside this range
during storage, it should be brought back within this range before operation.
In any event, the product must always be operated outdoors, in a well-
ventilated area and away from doors, windows and vents.
35
201156 – 3650W WIRELESS REMOTE START GENERATOR
TROUBLESHOOTING
Problem Engine will not start.
Engine starts but runs roughly. Engine will not start wirelessly. Engine will
not start electrically.
Cause
Solution
No fuel.
Add fuel.
Faulty spark plug.
Clean and adjust spark plug or replace.
Low oil level.
Fill crankcase to the proper level. Place generator on a flat, level surface.
Spark plug wire loose.
Attach wire to spark plug.
Fuel valve is closed.
Open fuel valve.
Engine switch OFF.
Press engine switch ON.
Old fuel or water in fuel.
Drain fuel and replace with fresh fuel.
Flooded with fuel.
Let unit stand for 10 mins.
CO Shield® module has been removed or Re-install module or contact technical
support.
tampered with.
Choke lever in the wrong position.
Move choke lever until it stops under RUN position.
Dirty air filter.
Clean or replace air filter.
Dirty fuel valve.
Clean the fuel valve.
Clogged spark arrestor.
Clean spark arrestor.
Remote control battery is dead.
Replace remote control battery.
Generator battery is dead.
Recharge generator battery.
Battery switch is in the OFF position. Turn battery switch to ON position.
Generator out of range of remote signal. Remote must be with 80 feet of generator.
Obstructions in between generator and Clear line of site between generator and
remote.
remote.
Generator battery is dead.
Recharge generator battery.
Battery switch is in the OFF position. Turn battery switch to ON position.
36
201156 – 3650W WIRELESS REMOTE START GENERATOR
TROUBLESHOOTING
Problem Engine shuts down during operation.
Engine starts and shuts off right away.
Cause Out of fuel. Low oil level.
If equipped, when CO Shield® shutoffs occur due to accumulating carbon
monoxide (CO) and if the red LED light blinks on the panel.
If equipped, when CO Shield® shutoffs occur due to system fault and if the
yellow LED light blinks on the panel. Clogged spark arrestor.
If equipped, when CO Shield® shutoffs occur due to accumulating carbon
monoxide (CO) and if the red LED light blinks on the panel.
If equipped, when CO Shield® shutoffs occur due to system fault and if the
yellow LED light blinks on the panel.
Solution
Fill fuel tank.
Fill crankcase to the proper level. Place generator on a flat, level surface.
Move generator to an open, outdoor area. Point exhaust away from people and
buildings. Move to fresh air and get medical help if sick, dizzy, or weak.
Make sure there are no objects creating obstructions within 5 feet of the
generator. Obstructions in the vicinity of the generator may trap carbon
monoxide emissions near the generator and cause the engine to shutoff.
If the generator’s exhaust is facing into the wind, the exhaust may be blown
back into the generator’s operating area, creating an accumulation of CO
emissions and triggering an engine shutoff. To avoid an engine shutoff, turn
the generator 45° in either direction to allow the exhaust emissions to blow
away from the generator. If engine shutoff events continue, readjust and align
the exhaust with the wind direction to blow away from the generator.
Start by confirming yellow LED light blinks when/ if generator shuts off. If
CO Shield® continues to sense the fault and shuts off, contact technical
support.
Clean spark arrestor.
Move generator to an open, outdoor area. Point exhaust away from people and
buildings. Move to fresh air and get medical help if sick, dizzy, or weak.
Make sure there are no objects creating obstructions within 5 feet of the
generator. Obstructions in the vicinity of the generator may trap carbon
monoxide emissions near the generator and cause the engine to shutoff.
If the generator’s exhaust is facing into the wind, the exhaust may be blown
back into the generator’s operating area, creating an accumulation of CO
emissions and triggering an engine shutoff. To avoid an engine shutoff, turn
the generator 45° in either direction to allow the exhaust emissions to blow
away from the generator. If engine shutoff events continue, readjust and align
the exhaust with the wind direction to blow away from the generator.
Start by confirming yellow LED light blinks when/ if generator shuts off. If
CO Shield® continues to sense the fault and shuts off, contact technical
support.
37
201156 – 3650W WIRELESS REMOTE START GENERATOR
TROUBLESHOOTING
Problem
Both CO Shield® LEDs not blinking 10 times upon start up.
Cause
Starting the generator within 1 minute after being manually shutoff, not a CO
shutoff event.
Generator cannot supply enough power or overheating.
Generator is overloaded. Dirty air filter. Choke lever in wrong position.
Engine is running but no AC output. Engine hunts or falters.
Poor cord connection. Circuit breaker is open. Faulty brush assembly. Faulty AVR (auto voltage regulator). Loose wiring. Other. Engine governor defective. Dirty fuel valve. Carburetor is dirty and running lean.
Choke lever in wrong position.
Overload.
Repeated circuit breaker tripping.
Faulty power cords or device.
Circuit breaker still too hot.
For other issues and technical support:
Technical Support Team Toll Free
1-877-338-0999
support@championpowerequipment.com
Solution Wait 1 minute before trying to restart the generator. The LEDs should then blink ten (10) times. Review load and adjust. See “Connecting Electrical Loads.” Clean or replace air filter. Move choke lever until it stops under RUN position. Check all connections. Reset circuit breaker. Check all circuit breakers. Replace brush assembly (Service Center). Replace AVR (Service Center). Inspect and tighten wiring connections. Contact the help line. Contact the help line. Clean the fuel valve. Contact the help line. Move choke lever until it stops under RUN position. Review load and adjust. See “Connecting Electrical Loads.” Check for damaged, bare or frayed wires. Replace defective device. Let unit sit for 5 mins.
38
WARRANTY*
CHAMPION POWER EQUIPMENT 3 YEAR LIMITED WARRANTY
Warranty Qualifications
To register your product for warranty and FREE lifetime call center technical
support please visit: https://www.championpowerequipment.com/register To
complete registration you will need to include a copy of the purchase receipt
as proof of original purchase. Proof of purchase is required for warranty
service. Please register within ten (10) days from date of purchase.
Repair/Replacement Warranty
CPE warrants to the original purchaser that the mechanical and electrical
components will be free of defects in material and workmanship for a period of
three years (parts and labor) from the original date of purchase and 270 days
(parts and labor) for commercial and industrial use. Transportation charges on
product submitted for repair or replacement under this warranty are the sole
responsibility of the purchaser. This warranty only applies to the original
purchaser and is not transferable.
Do Not Return The Unit To The Place Of Purchase
Contact CPE’s Technical Service and CPE will troubleshoot any issue via phone
or e-mail. If the problem is not corrected by this method, CPE will, at its
option, authorize evaluation, repair or replacement of the defective part or
component at a CPE Service Center. CPE will provide you with a case number for
warranty service. Please keep it for future reference. Repairs or replacements
without prior authorization, or at an unauthorized repair facility, will not
be covered by this warranty.
Warranty Exclusions
This warranty does not cover the following repairs and equipment: Normal Wear
Products with mechanical and electrical components need periodic parts and
service to perform well. This warranty does not cover repair when normal use
has exhausted the life of a part or the equipment as a whole. Installation,
Use and Maintenance This warranty will not apply to parts and/or labor if the
product is deemed to have been misused, neglected, involved in an accident,
abused, loaded beyond the product’s limits, modified, installed improperly or
connected incorrectly to any electrical component. Normal maintenance is not
covered by this warranty and is not required to be performed at a facility or
by a person authorized by CPE.
Other Exclusions
This warranty excludes:
Cosmetic defects such as paint, decals, etc.
Wear items such as filter elements, o-rings, etc.
Accessory parts such as starting batteries, and storage covers.
Failures due to acts of God and other force majeure events beyond the
manufacturer’s control.
Problems caused by parts that are not original Champion Power Equipment
parts.
When applicable, this warranty does not apply to products used for prime power
in place of a utility.
Limits of Implied Warranty and Consequential Damage
Champion Power Equipment disclaims any obligation to cover any loss of time,
use of this product, freight, or any incidental or consequential claim by
anyone from using this product. THIS WARRANTY AND THE ATTACHED U.S. EPA and/or
CARB EMISSION CONTROL SYSTEM WARRANTIES (WHEN APPLICABLE) ARE IN LIEU OF ALL
OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE. A unit provided as an exchange will be
subject to the warranty of the original unit. The length of the warranty
governing the exchanged unit will remain calculated by reference to the
purchase date of the original unit. This warranty gives you certain legal
rights which may change from state to state or province to province. Your
state or province may also have other rights you may be entitled to that are
not listed within this warranty.
Contact Information
Address Champion Power Equipment, Inc. 12039 Smith Ave. Santa Fe Springs, CA
90670 USA www.championpowerequipment.com Customer Service Toll Free:
1-877-338-0999
info@championpowerequipment.com Fax no.:
1-562-236-9429 Technical Service Toll
Free: 1-877-338-0999
tech@championpowerequipment.com EMERGENCY 24 HOUR SUPPORT:
1-562-204-1188
*Except as otherwise stipulated in any of the following enclosed Emission Control System Warranties (when applicable) for the Emission Control System: U.S. Environment Protection Agency (EPA) and/or California Air Resources Board (CARB).
CHAMPION POWER EQUIPMENT, INC. (CPE), THE UNITED STATES ENVIRONMENTAL
PROTECTION AGENCY (U.S. EPA) AND THE CALIFORNIA AIR RESOURCES BOARD (CARB)
EMISSION CONTROL SYSTEM WARRANTY
Your Champion Power Equipment (CPE) engine complies with both the U.S. EPA and
state of California Air Resources Board (CARB) emissions regulations.
YOUR WARRANTY RIGHTS AND OBLIGATIONS:
The US EPA, California Air Resources Board, and CPE are pleased to explain the
Federal and California Emission Control Systems warranty on your 2023 small
off-road engine (SORE) and equipment. In the United States and California, new
small off-road engines (SORE) and new equipment that use small off-road
engines (SORE) must be designed, built and equipped to meet the State’s
stringent anti-smog standards.
CPE must warrant the emission control system on your small off-road engine
(SORE) and equipment for the period of time listed below, provided there has
been no abuse, neglect or improper maintenance of your small off-road engine
(SORE) and equipment leading to the failure of the emission control system.
Your emission control system may include parts such as the carburetor, fuel-
injection system, the ignition system, catalytic converter, fuel tanks, fuel
lines (for liquid fuel and fuel vapors), fuel caps, valves, canisters,
filters, clamps, connectors, and other associated components. Also included
may be hoses, belts, and other emission related assemblies. Where a
warrantable condition exits, CPE will repair your small off-road engine (SORE)
and equipment at no cost to you including diagnosis, parts and labor.
MANUFACTURER’S WARRANTY COVERAGE:
This Emissions Control System is warranted for two years. If any emissions-
related part on your small off-road engine (SORE) and equipment is defective,
the part will be repaired or replaced by CPE.
OWNER WARRANTY RESPONSIBILITIES:
As the small off-road engine (SORE) and equipment owner, you are responsible
for the performance of the required maintenance listed in your Owner’s Manual.
CPE recommends that you retain all your receipts covering maintenance on your
small off-road engine (SORE) and equipment, but CPE cannot deny warranty
coverage solely for the lack of receipts or for your failure to ensure the
performance of all scheduled maintenance.
As the small off-road engine (SORE) and equipment owner, you should be aware
that CPE may deny you warranty coverage if your small off-road engine (SORE)
and equipment or a part has failed due to abuse, neglect, improper maintenance
or unapproved modifications.
You are responsible for presenting your small off-road engine (SORE) and
equipment to an Authorized CPE service outlet or alternate service outlet as
described in (3)(f.) below, CPE dealer or CPE, Santa Fe Springs, Ca. as soon
as a problem exists. The warranty repairs shall be completed in a reasonable
amount of time, not to exceed 30 days.
If you have any questions regarding your warranty coverage, you should
contact:
Champion Power Equipment, Inc. Customer Service 12039 Smith Ave.
Santa Fe Springs, CA 90670
1-877-338-0999
tech@championpowerequipment.com
EMISSION CONTROL SYSTEM WARRANTY
The following are specific provisions relative to your Emission Control System
(ECS) Warranty Coverage.
1. APPLICABILITY: This warranty shall apply to 1995 and later model year
California small off-road engines (SORE) (for other states, 1997 and later
model year engines). The ECS Warranty Period shall begin on the date the new
engine or equipment is delivered to its original, end-use purchaser, and shall
continue for 24 consecutive months thereafter.
2. GENERAL EMISSIONS WARRANTY COVERAGE CPE warrants to the original, end-use
purchaser of the new engine or equipment and to each subsequent purchaser that
each of its small off-road engines (SORE) is:
2a. Designed, built and equipped so as to conform to U.S. EPA emissions
standards for spark- ignited engines at or below 19 kilowatts and all
applicable regulations adopted by the California Air Resources Board; and
2b. Free from defects in materials and workmanship that cause the failure of a
warranted part to be identical in all material respects to the part as
described in the engine manufacturer’s application for certification for a
period of two years.
3. THE WARRANTY ON EMISSION-RELATED PARTS WILL BE INTERPRETED AS FOLLOWS:
3a. Any warranted part that is not scheduled for replacement as required
maintenance in the Owner’s Manual shall be warranted for the ECS Warranty
Period. If any such part fails during the ECS Warranty Period, it shall be
repaired or replaced by CPE according to Subsection “d” below. Any such part
repaired or replaced under the ECS Warranty shall be warranted for a time not
less than the remainder of the ECS Warranty Period.
3b. Any warranted, emissions-related part which is scheduled only for regular
inspection as specified in the Owner’s Manual shall be warranted for the ECS
Warranty Period. A statement in such written instructions to the effect of
“repair or replace as necessary” shall advise owners of the warranty coverage
for emission related parts. Replacement within the warranty period is covered
by the warranty and shall not reduce the ECS Warranty Period. Any such part
repaired or replaced under the ECS Warranty shall be warranted for a time not
less than the remainder of the ECS Warranty Period.
3c. Any warranted, emissions-related part which is scheduled for replacement
as required maintenance in the Owner’s Manual shall be warranted for the
period of time prior to the first scheduled replacement point for that part.
If the part fails prior to the first scheduled replacement, the part shall be
repaired or replaced by CPE according to Subsection “d” below. Any such
emissionsrelated part repaired or replaced under the ECS Warranty, shall be
warranted for a time not less than the remainder of the ECS Warranty Period
prior to the first scheduled replacement point for such emissions-related
part.
3d. Repair or replacement of any warranted, emissions-related part under this
ECS Warranty shall be performed at no charge to the owner at a CPE Authorized
Service Outlet.
3e. The owner shall not be charged for diagnostic labor which leads to the
determination that a part covered by the ECS Warranty is in fact defective,
provided that such diagnostic work is performed at a CPE Authorized Service
Outlet.
3f. CPE shall pay for covered emissions warranty repairs at non-authorized
service outlets under the following circumstances:
i. The service is required in a population center with a population over
100,000 according to U.S. Census 2000 without a CPE Authorized Service Outlet
AND
ii.The service is required more than 100 miles from a CPE Authorized Service
Outlet. The 100 mile limitation does not apply in the following states:
Alaska, Arizona, Colorado, Hawaii, Idaho, Montana, Nebraska, Nevada, New
Mexico, Oregon, Texas, Utah and Wyoming.
3g. CPE shall be liable for damages to other original engine components or
approved modifications proximately caused by a failure under warranty of an
emission-related part covered by the ECS Warranty.
3h. Throughout the ECS Warranty Period, CPE must maintain a supply of
warranted emission-related parts sufficient to meet the expected demand for
such emission-related parts and must obtain additional parts if that supply is
exhausted.
3i. Any CPE Authorized and approved emission-related replacement part that do
not increase the exhaust or evaporative emissions of the engine or emissions
control system may be used in the performance of any ECS Warranty maintenance
or repair and will be provided without charge to the owner. Such use shall not
reduce CPE’s warranty obligation.
3j. Unapproved add-on or modified parts may not be used to modify or repair a
CPE engine. Such use voids this ECS Warranty and shall be sufficient grounds
for disallowing an ECS Warranty claim. CPE shall not be liable hereunder for
failures of any warranted parts of a CPE engine caused by the use of such an
unapproved add-on or modified part.
EMISSION-RELATED PARTS INCLUDE THE FOLLOWING: (using those portions of the list applicable to the engine)
Systems covered by this warranty
Fuel Metering System Air Induction System Ignition System Exhaust System
Miscellaneous Parts Evaporative Emissions
Parts Description
Fuel regulator, Carburetor and internal parts Air cleaner, Intake manifold
Spark plug and parts, Magneto ignition system Exhaust manifold, catalytic
converter Tubing, Fittings, Seals, Gaskets, and Clamps associated with these
listed systems. Fuel Tank, Fuel Cap, Fuel Lines (for liquid fuel and fuel
vapors), Fuel Line Fittings, Clamps, Pressure Relief Valves, Control Valves,
Control Solenoids, Electronic Controls, Vacuum Control Diaphragms, Control
Cables, Control Linkages, Purge Valves, Gaskets, Liquid/Vapor Separator,
Carbon Canister, Canister Mounting Brackets, Carburetor Purge Port Connector
TO OBTAIN WARRANTY SERVICE:
You must take your CPE engine or the product on which it is installed, along
with your warranty registration card or other proof of original purchase date,
at your expense, to any Champion Power Equipment dealer who is authorized by
Champion Power Equipment, Inc. to sell and service that CPE product during his
normal business hours. Alternate service locations defined in Section (3)(f.)
above must be approved by CPE prior to service. Claims for repair or
adjustment found to be caused solely by defects in material or workmanship
will not be denied because the engine was not properly maintained and used.
If you have any questions regarding your warranty rights and responsibilities,
or to obtain warranty service, please write or call Customer Service at
Champion Power Equipment, Inc.
Champion Power Equipment, Inc. 12039 Smith Ave.
Santa Fe Springs, CA 90670
1-877-338-0999
Attn.: Customer Service
tech@championpowerequipment.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>