SPACE-RAY Apollo Electric Shortwave Radiant Heater Installation Guide

June 13, 2024
SPACE-RAY

SPACE-RAY logo

INSTALLATION MANUAL
Electric Shortwave Radiant Heater
For Internal Use

SPACE-RAY Apollo Electric Shortwave Radiant Heater

Model Apollo

Important

CAUTION! When using Spaceray electric heaters, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:

Read all instructions before using this heater.

  • Before using this appliance:
    – Check that the voltage indicated on the type plate corresponds to the mains supply voltage.
    – Ensure that the heater has been securely fastened in its final mounting position.

  • Do not locate the heater immediately below a socket outlet.

  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

  • Children of less than 3 years should be kept away unless continually supervised.

  • Children aged from 3 years and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children aged from 3 years and less than 8 years shall not plug in, regulate and clean the appliance or perform user maintenance.

  • CAUTION Some parts of the product can become very hot and cause burns. Particular attention has been given where children and vulnerable people are present.

  • Disconnect pole switch from the hard wired circuit during installation, cleaning and/or replacing the lamp emitter and always ensure that the lamp emitter is cool.

  • The heater is designed for indoor use and should only be installed in conjunction with a suitable energy saving controller.

  • Do not use an extension cord with this product because the extension cord may overheat and cause a risk of fire.

  • Keep the mains supply cord away from the body of the heater which will get hot during use.

  • Arrange the mains supply cord so it cannot be tripped over or damaged.

  • Do not cover or obstruct the heater while it is in use.

  • Do not insert any object through any slot or opening in the heater.

  • Do not use if a guard is not present.

  • Do not install less than the minimum mounting distance from the floor.

  • WARNING: This heater should only be installed indoors with a thermostat device to control the room temperature and operated by users capable of using the device. Do not use this heater in small rooms when they are occupied by persons not capable of leaving the room on their own, unless constant supervision is provided.

  • Do not touch the heater when it is turned on, as the body gets hot.

  • Do not use the heater in a bathroom, laundry areas and similar locations. Never locate the heater where it may fall into a bathtub or other water container.

  • A heater has hot parts inside. Do not use it in areas where petrol, paint, or flammable liquids are used or stored.

  • CAUTION: Do not direct a hose or spray water at the heater or into any of its openings.

  • WARNING: If the supply cord becomes damaged, it must be replaced by the manufacturer, its service agent or a similar qualified person in order to avoid a hazard.

  • WARNING: This appliance must be connected to a supply that is earthed!

IMPORTANT:
SAVE THESE INSTRUCTIONS FOR FUTURE USE.

WARNING: RISK OF FIRE
Keep combustible material such as furniture, papers, clothes and curtains 1.8m (6ft) from the front of the heater and away from the sides and rear.
If the heater is to be used outside, it is recommend that a waterproof or indoor socket outlet is used.

Introduction

The Apollo internal heater produces radiant heat like the sun, warming people and objects rather than the air in between. It is designed to blend into environments old and new, providing a cost effective, pollution free form of heating.
Please read the following instructions carefully before use. The safety of this heater is guaranteed only by its correct usage in accordance with these instructions, therefore it is recommended that they are retained for future reference.

Specification

Model| Voltage| Lamps| Total Power| Phase| Current per Phase| Min height From Floor| Min Distance from Ceiling| Min Distance From Side Wall| Dimensions (L x W X D) mm| Weight
---|---|---|---|---|---|---|---|---|---|---
A1A2-010| 230V| 1 x 1.0kW| 1.0kW| Single| 4.3A| 2.0m| 0.3m| 1.0m| 420 x 260 x 120| 3.1kg
A1A2-015| 1 x 1.5kW| 1.5kW| 6.5A
A1A2-020| 1 x 2.0kW| 2.0kW| 8.7A
A1B2-020| 230V| 2 x 1.0kW| 2.0kW| Single| 8.7A| 2.0m| 0.5m| 1.5m| 420 x 390 x 120| 4.1kg
A1B2-030| 2 x 1.5kW| 3.0kW| 13.0A
A1B2-040| 2 x 2.0kW| 4.0kW| 17.4A
A1C2-030| 230V| 3 x 1.0kW| 3.0kW| Single| 13.0A| 2.0m| 0.5m| 1.5m| 420 x 530 x 120| 5.7kg
A1C2-045| 3 x 1.5kW| 4.5kW| 19.6A| 2.5m
A1C2-060| 3 x 2.0kW| 6.0kW| 26.0A| 3.0m
A1J2-020| 230V| 2 x 1.0kW| 2.0kW| Single| 8.7A| 2.5m| 0.5m| 1.0m| 860 x 260 x 120| 6.1kg
A1J2-030| 2 x 1.5kW| 3.0kW| 13.0A
A1J2-040| 2 x 2.0kW| 4.0kW| 17.4A
A1K2-030| 230V| 3 x 1.0kW| 3.0kW| ****

Single

| 13.0A| 2.5m| 0.5m| 1.5m| 1280 x 260 x 120| 8.2kg
A1K2-045| 3 x 1.5kW| 4.5kW| 19.6A
A1K2-060| 3 x 2.0kW| 6.0kW| 26.0A| 3.0m
A3C2-030| 400V| 3 x 1.0kW| 3.0kW| Three| 4.3A| 2.0m| 0.5m| 1.5m| 420 x 530 x 120| 5.7kg
A3C2-045| 3 x 1.5kW| 4.5kW| 6.5A| 2.5m
A3C2-060| 3 x 2.0kW| 6.0kW| 8.7A| 3.0m
A3E2-060| 400V| 6 x 1.0kW| 6.0kW| Three| 8.7A| 3.0m| 0.5m| 1.5m| 860 x 630 x 120| 12.8kg
A3E2-090| 6 x 1.5kW| 9.0kW| 13.0A| 4.0m
A3E2-120| 6 x 2.0kW| 12.0kW| 17.4A| 4.5m
A3F2-090| 400V| 9 x 1.0kW| 9.0kW| Three
| 13.0A| 4.0m| 0.5m| 1.5m| 1280 x 630 x 120| 20.6kg
A3F2-135| 9 x 1.5kW| 13.5kW| 19.6A| 5.0m
A3F2-180| 9 x 2.0kW| 18.0kW| 26.1A| 6.0m
A3K2-030| 400V| 3 x 1.0kW| 3.0kW| Three*| 4.3A| *** 2.5m| 0.5m| 1.5m| 1280 x 260 x 120| 8.2kg
A3K2-045| 3 x 1.5kW| 4.5kW| 6.5A
A3K2-060| 3 x 2.0kW| 6.0kW| 8.7A| 3.0m
A3L2-060| 400V| 6 x 1.0kW| 6.0kW| Three
| 8.7A| 3.0m| 0.5m| 1.5m| 1280 x 440 x 120| 17.4kg
A3L2-090| 6 x 1.5kW| 7.5kW| 13.0A| 4.0m
A3L2-120| 6 x 2.0kW| 12.0kW| 17.4A| 4.5m

Table 1. Note: Use MCB Type C. *Star connection with neutral star point to balance load.

Installation

CAUTION
Always isolate the heater from the mains supply when mounting or adjusting the heater position.

Models A1A2-010, A1A2-015, A1A2-020, A1B2-020, A1B2-030, A1C2-030, A1B2-040, A1C2-045 and A1C2-060 are fitted with 2.0m of supply cord for hard wiring (directly into a control device) therefore it is unnecessary to remove the terminal cover plate in
order to carryout normal installation of these models.

All other models have a terminal box in which the mains supply cord can be connected from a control device.
Warning: This appliance MUST be earthed.
CAUTION: Please observe the minimum safe distance between the heater body and any inflammable surfaces.
CAUTION: All installations must be in accordance with the latest electrical safety regulations. If in any doubt, please consult a suitably qualified electrician.
NOTE: When hard wiring, a large double pole switch with a 3.0mm contact disconnection should be fitted.
NOTE: We recommend using a RCD where applicable.

4.1 Wall Installation

  • The heater must be mounted in such a way that the halogen lamp does not slant more than 4° from the horizontal, when viewed from the front.
  • The heater is suitable for installation only on a normally non-flammable surface. Observe the minimum safe distance between the heater body and inflammable surfaces when mounting.
  • Do not position the heater near to furniture or curtains as this could present a fire hazard.
  • Refer to Table 1 for the recommended mounting height for the heater.
  • Please refer to Table 1 for the recommended installation height of the heater.
  • Keep out of the reach of children.
  1. Separate the heater from the mounting bracket by loosening the two nuts at the rear of the heater.
  2. Securely fasten the bracket to the mounting surface using the fixing holes in the bracket.
  3. Replace the heater on the bracket using the nut and bolt supplied and fix in the required angular position by tightening the fixing bolt on the bracket. See Figs 1 and 2.

Always isolate the heater from the mains supply when adjusting the angular position.

SPACE-RAY Apollo Electric Shortwave Radiant Heater - Fig
1

SPACE-RAY Apollo Electric Shortwave Radiant Heater - Fig
2

4.2 Suspended Installation

  • The heater is suitable for installation on chains that are suitably fixed to a structure sufficient to hold the weight of the heater. Observe the minimum safe distance between the heater body and inflammable surfaces when mounting.
  • Please refer to Table 1 for the recommended positioning of the heater with regards to minimum distances. Do not install the heater in a corner. If installing near a corner, always ensure minimum side wall distance is adhered to.
  • Do not position the heater near to furniture or curtains as this would present a fire hazard.
  • Always allow the heater to cool before attempting to reposition/move. Never attempt to move the heater while it is switched on!
  1. When chain hung, ensure chains are of adequate size and securely fixed to support the weight of the heater.
  2. Fix the heater assembly to the chains via the holes in the body bracket(s) as shown in Figs. 3 & 4.
  3. Ensure the supply cord does not rest on the heater.

SPACE-RAY Apollo Electric Shortwave Radiant Heater - Fig
3

Lamp Replacement

CAUTION
Unplug/switch off from the mains power to the heater (including control device) before any attempts are made to replace the lamp.
Contact your service agent for the correct replacement lamp quoting model type and rating from rating label.
It is important that you read through the lamp replacement procedure before commencing.

It is very important that your replacement lamp is exactly the same as the one it was supplied with. Failure to fit the exact same type could cause the heater to fail or even become dangerous. Please contact your distributor to purchase your replacement lamp and state the model number of the heater you wish to fit the lamp to.
5.1 Handling a replacement lamp emitter
A new lamp emitter should not be handled with bare hands.
Remove finger marks with a soft cloth and methylated spirits or rubbing alcohol. Finger marks will burn into the lamp emitters quartz glass causing premature failure.

5.2 Fitting a new lamp emitter

  1. Disconnect the power supply to the heater.
  2. Remove guard (where fitted) by flexing one end and releasing from its locating holes on the lamp to be replaced.
  3. Remove the three screws from both front side covers (Fig. 5) on the ‘A, B & C’ series models and depending on the other series models, the middle cover(s) will need to be removed by removing the screws from both sides as shown in Fig. 6.SPACE-RAY Apollo Electric Shortwave Radiant Heater - Fig 4SPACE-RAY Apollo Electric Shortwave Radiant Heater - Fig 5
  4. Locate the lamp wire (Fig. 7) and hold it by the terminal and pull up to release from tab (Fig. 8). Repeat at other end.SPACE-RAY Apollo Electric Shortwave Radiant Heater - Fig 6SPACE-RAY Apollo Electric Shortwave Radiant Heater - Fig 7
  5. Remove the lamp holding clips (Fig. 9) by squeezing the clip together and lifting away as shown in Fig. 10.
  6. Slide the lamp out through the extrusion feeding one way first with the wire and then the opposite way to take out and remove. Take care not to scratch the reflector surface.
  7. Refit the new lamp. Take care not to mark the reflector or touch the new lamp with the hands (see note above).
  8. Replace the lamp holding clips. Make sure they are firmly in place over the white ceramic ends of the lamp.
  9. Refit the lamp wire terminals by fully pushing onto the tabs.
  10. Replace the front side and or middle covers in reverse order and then refit the wire guard(s) if originally fitted.

SPACE-RAY Apollo Electric Shortwave Radiant Heater - Fig
9

 Warranty

This product carries a full 24 month warranty from original date of purchase when used in accordance with these instructions. This excludes lamp when used in a commercial application, which then carry a 30 day warranty from original date of purchase.
This is subject to the heater being installed correctly and in accordance with these instructions. Should your product be faulty, please contact the distributor from which you purchased the appliance. Please quote the serial number, model number, rating and
date of purchase.
(excludes breakages)
CAUTION! Do not touch the heater during operation!

Recycling information

**** The use of this symbol indicates that this product may not be treated as household waste. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product.
For more detailed information about recycling of this product, please contact your local council or your household waste disposal service.

Declaration of conformity

This product complies with:
British Standard: BS 60335-1:2012 in conjunction with BS 60335-2-30:2009 + A11 and BS 62233 and the European Standard Electromagnetic Compatibility EEC Directives 2004/108/EC and 89/336/EEC and the RoHS Directive 2011/65/EU.

SPACE-RAY logo

Tel: +44(0)1473 830 551
Fax: +44(0)1473 832055
www.spaceray.co.uk
info@spaceray.co.uk

https://spaceray.co.uk

Gas Fired Products (UK) Ltd
Chapel Lane
Claydon
Ipswich
Suffolk, IP6 0JL

SPACE-RAY Apollo Electric Shortwave Radiant Heater - Symbol
4

FACTORIES: IPSWICH, ENGLAND – CHARLOTTE, N.C, U.S.A

Documents / Resources

| SPACE-RAY Apollo Electric Shortwave Radiant Heater [pdf] Installation Guide
A1A2-010, A1A2-015, A1A2-020, A1B2-020, A1B2-030, A1B2-040, A1C2-030, A1C2-045, A1C2-060, A1J2-020, A1J2-030, A1J2-040, A1K2-030, A1K2-045, A1K2-060, A3C2-030, A3C2-045, A3C2-060, A3E2-060, A3E2-090, A3E2-120, A3F2-090, A3F2-135, A3F2-180, A3K2-030, A3K2-045, A3K2, Apollo, Apollo Electric Shortwave Radiant Heater, Electric Shortwave Radiant Heater, Shortwave Radiant Heater, Radiant Heater, Heater
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals