  • Product Name: RAB Lighting SLIM17 FA
  • Wattage Options: 40-60W, 100-120-150W
  • Product Description: RAB Lighting SLIM17 FA is a high-quality, affordable, well-designed, and energy-efficient LED lighting fixture. It is designed to make installation easy for electricians and allows end users to save energy.

Specifications

  • Suitable for outdoor applications
  • Universal voltage driver permits operation at 120V through 277V, 50 or 60 Hz
  • 0-10V dimmable

INSTRUCTIONS

RAB Lighting is committed to creating high-quality, affordable, well-designed, and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com

MODELS

RAB-Lighting-SLIM17FA-40-60W-LED-Field-Adjustable-Wall-Packs-
FIG-1

IMPORTANT

READ CAREFULLY BEFORE INSTALLING THE FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB fixtures must be wired under the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.

Min 90 °C SUPPLY CONDUCTORS.

  • WARNING: Make certain power is OFF before installing or maintaining the fixture. No user-serviceable parts inside. WARNING: Do not use an electric generator to test LED fixtures.
  • CAUTION : For proper weatherproofing function, all gaskets must be seated properly and all screws inserted and tightened. This is important with an uneven wall surface. Silicone all plugs and unused conduit entries.
    For wet location compliance, the fixture must be properly sealed. For moisture seal, apply silicone caulking between the mounting surface and back housing, as well as around the sides of the housing. This is important with uneven wall surfaces.

WALL MOUNT

Suitable for outdoor applications.

  1. Using a screwdriver loosen side Housing Screws (2) as shown in Fig. 1.

  2. Remove the Housing Back Plate (Fig. 2) and unscrew the center Plug, using a drill to open installation holes in the Housing Back Plate.

  3. Apply the Foam Gasket (provided) to the external surface of the Housing Back Plate by removing the yellow plastic film and adhering to the Housing Back Plate as shown in Fig. 3.

  4. Feed supply wires through the Housing Back Plate as shown in Fig. 4. Wire the Housing leads to supply wires using UL-listed wire connectors according to NEC and local codes (Fig. 8). Push all wires into the Housing.

  5. Secure Housing Back Plate to the surface or junction box
    (supplied by others) with Screws (supplied by others) as shown in Fig. 5.

  6. Mount the Housing over the Housing Back Plate and secure it with (2) Screws (provided) as shown in Fig. 6.

  7. For Conduit wiring, remove the Side Conduit Cap using
    a screwdriver as shown in Fig. 1. Feed supply wires through a conduit opening with a suitable connector. Wire the Housing leads to supply wires using UL- listed wire connectors according to NEC and local codes
    (Fig. 8). Push all wires into the Housing. Follow mounting instructions.

RAB-Lighting-SLIM17FA-40-60W-LED-Field-Adjustable-Wall-Packs-
FIG-2

FIELD ADJUSTMENT
Follow the instructions below to change the fixture Color Temperature (CCT) from the factory settings and Photocell On/Off option.

Factory Settings: 4000K

  1.  Locate the Color Temperature (CCT) and Photocell On/Off switches on the side of Housing as shown in Fig. 7.
  2.  Select Color Temperature (CCT) and Photocell On/Off position by sliding the respective switches to the desired value.RAB-Lighting-SLIM17FA-40-60W-LED-Field-Adjustable-Wall-Packs-FIG-3

0-10V DIMMABLE WIRING
Universal voltage driver permits operation at 120V through 277V, 50, or 60 Hz. For 0-10 dimming, follow the wiring directions as shown in Fig. 8.

  1. Connect the black/brown fixture lead to the LINE supply lead.
  2. Connect the white/blue fixture lead to the COMMON supply lead.
  3. Connect the green/yellow wire from the fixture to the supply ground. Do NOT connect the GROUND of the dimming fixture to the output.
  4. Connect the purple fixture lead to the DIM V+ lead.
  5. Connect the pink fixture lead to the DIM V- lead.
  6. Cap the yellow fixture lead, if present. Do NOT connect.

CLEANING & MAINTENANCE

CAUTION : Be sure the fixture temperature is cool enough to touch. Do not clean or maintain while the fixture is energized.

  1. Clean polycarbonate lens with a non-abrasive glass cleaning solution.
  2. Do not open the fixture to clean the LED. Do not touch the LED.

TROUBLESHOOTING

  1. Is the fixture grounded properly?
  2. It is recommended to wear gloves to avoid injury during installation.
  3. If any smoke or spark, please turn off the power immediately.

Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.

Easy Answers

rablighting.com
Visit our website for product info

Tech Help Line
Call our experts: 888 722-1000
e-mail
Answered promptly – sales@rablighting.com
Free Lighting Layouts
Inc. Answered online or by request

© 2023 RAB LIGHTING Inc.
SLIM17 FA 40W-150W – IN-1123 73719-RAB

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

RAB Lighting User Manuals

Related Manuals