VXBRLED® INSTALLATION
VXBRLED 13W & 26W
VXBRLED LED Vapor Tight Jelly Jar
RAB Lighting is committed to creating high-quality, aff ordable, well-designed and energy-effi cient LED lighting and controls that make it easy for electricians to install and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE
REFERENCE.
RAB fi xtures must be wired in accordance with the National Electrical Code and
all applicable local codes. Proper grounding is required for safety. THIS
PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE
BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND
THE HAZARDS INVOLVED.
WARNING: Make certain power is OFF before installing or maintaining fi
xture. No user serviceable parts inside.
CAUTION: For proper weatherproof function all gaskets must be seated
properly and all screws inserted and tightened fi rmly. Apply weatherproof
silicone sealant around the edge of the ceiling mounting box and/or junction
box. This is especially important with an uneven ceiling surface. Silicone all
plugs and unused conduit entries.
WALL MOUNTING
Fixture must be wall mounted. Use a recessed or surface mount junction box (not supplied) or use the Housing as the junction box. Inner globe is provided for clear and colored globes. Fixture cannot be mounted upside down in wet locations! DO NOT USE FIXTURE WITHOUT OUTER GLOBE.
- Loosen Housing Screws and open Housing.
- Prepare back of Housing to use by knocking out necessary mounting holes.
- Seal all gaps between ceiling and fi xture with weatherproof silicone sealant.
- Fixture may be wired through back conduit entrance or side conduit entrance for surface mounting.
- Connect wires as shown in wiring section.
- Close Housing. Tighten screws and check Housing Gasket seal.
- Seal all holes, plugs, and conduit entrances with weatherproof silicone sealant.
- Screw in required glass globe or permaglobe. Tighten Outer Globe until it makes full contact with Globe Gasket. OUTER GLOBE REQUIRED!
- Screw on optional wire or diecast Guard.
WIRING
Universal voltage driver permits operation at 120V thru 277V, 50 or 60 Hz.
- Connect the black fi xture lead to the (+) LINE supply lead.
- Connect the white fi xture lead to the (-) COMMON supply lead.
- Connect the GROUND wire from fi xture to supply ground.
CLEANING & MAINTENANCE
CAUTION: Be sure fi xture temperature is cool enough to touch.
Do not clean or maintain while fi xture is energized.
- Do not open fi xture to clean the LED. Do not touch the LED.
- Clean glass lens & fi xture with non-abrasive glass cleaning solution.
TROUBLESHOOTING
- Check that the line voltage at fi xture is correct.
- Is there voltage at the lamp fi xture wires? If there is no voltage, check all connections.
- Is the fi xture is grounded properly?
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.
© 2024 RAB LIGHTING Inc.
Easy Answers
rablighting.com
Visit our website for product info
Tech Help Line
Call our experts: 888 722-1000
e-mail
Answered promptly – sales@rablighting.com
Free Lighting Layouts
Answered online or by request
VXBRLED-IN 0124-73331-RAB
RAB WARRANTY: RAB’s warranty is subject to all terms and conditions found at
rablighting.com/warranty.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>