RAB LIGHTING A22 Field Adjustable Area Lights Installation Guide

May 15, 2024
RAB Lighting

RAB LIGHTING A22 Field Adjustable Area Lights

RAB-LIGHTING-A22-Field-Adjustable-Area-Lights-product

Product Information

Specifications:

  • Model: A22TM
  • Mounting Options: Pole Mount-Adjustable Universal Arm, Slipfitter Mount
  • Compatible Pole Size: Fits 2 3/8 O.D. Tenon
  • Manufacturer: RAB Lighting

Product Usage Instructions

Pole Mount-Adjustable Universal Arm Installation:

  1. Place the Bolster Plate inside a Square or Round Pole and secure the Arm with Bolts to the Bolster Plate.
  2. Feed the fixture and supply wires into the Arm Wiring Compartment and make appropriate wire connections as per wiring diagram and NEC.
  3. To adjust the fixture angle, loosen the Locking Bolt, swivel the fixture to the desired angle, and tighten the Locking Bolt.

Slipfitter Mount Installation:

  1. Remove the Adjustable Universal Arm by removing the fixture Securing Screw.
  2. Separate the Slipfitter assembly, feed wires from the fixture through the Slipfitter, and reconnect the Swivel Bolt.
  3. Secure the fixture with Set Screws on the side of the Slipfitter.
  4. To adjust the fixture angle of the Slipfitter, loosen the Swivel Bolt and swivel the fixture to the desired angle using the Slipfitter Cover Plate as a guideline.

FAQ (Frequently Asked Questions)

  • Q: What should I do if I need further assistance or have feedback?
    A: For further assistance or feedback, please contact the Marketing Department at 888-RAB-1000 or email marketing@rablighting.com.

  • Q: Can I mount the Slipfitter at any angle?
    A: No, mounting the Slipfitter at an angle of more than 20 degrees vertically increases the risk of disengagement and failure. It should be mounted within 0-20 degrees from vertical.

RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.comRAB-LIGHTING-A22
-Field-Adjustable-Area-Lights-fig-1

IMPORTANT

  • READ CAREFULLY BEFORE INSTALLING THE FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
  • RAB fixtures must be wired following the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED per THE APPLICABLE INSTALLATION CODE BY A PERSON
  • FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.

WARNING : Make certain power is OFF before installing or maintaining the fixture. No user-serviceable parts inside.
CAUTION : For proper weatherproof function all gaskets must be seated properly and all screws inserted and tightened firmly. Apply weatherproof silicone sealant around the edge of the junction box. This is especially important with an uneven surface. Silicone all plugs and unused conduit entries.

POLE MOUNT-ADJUSTABLE UNIVERSAL ARM

  1. Place the Bolster Plate (provided) inside a Square or Round Pole as shown in Fig. 1, and secure the Arm to the pole with (2) Bolts to the Bolster Plate.
  2. Open the Arm Cover (Fig. 2) feed the fixture and supply wires into the Arm Wiring Compartment to make the wire connections as per wiring diagram ( Fig. 15 ). Make appropriate wire connections as per NEC.
  3. To adjust the fixture angle, loosen the Locking Bolt as shown in Fig. 2. Swivel the fixture to the desired angle and tighten Locking Bolt.
  4. The graduation of the Adjustable Arm Cover Plate can be used for guidelines to adjust the fixture angle (Fig. 3 and 4). Maximum tilt is ± 60°.

SLIPFITTER MOUNT

(Accessory ordered separately – Model # A22SF, A22SFW, A22SFB)
WARNING : RISK OF SERIOUS INJURY OR DEATH!
DO NOT MOUNT THE SLIPFITTER TO A TENON OR BRACKET THAT IS MORE THAN 20 DEGREES FROM VERTICAL. MOUNTING ANY ANGLE OTHER THAN 0-20 DEGREES INCREASES THE RISK OF DISENGAGEMENT AND/OR FAILURE OF THE SLIPFITTER. INSTALL THE POLE ON A SECURE BASE OR INSTALL THE BRACKET TO A WALL FIRST. THEN PLACE THE LUMINAIRE ONTO THE POLE OR BRACKET. DO NOT LIFT ASSEMBLED LUMINAIRE OR POLE OR LUMINAIRE & BRACKET. LUMINAIRE OR POLE/BRACKET MAY DISENGAGE.

  1. Remove the Adjustable Universal Arm by removing the fixture Securing Screw as shown in Fig. 5.
  2. Separate the Slipfitter assembly by removing the Swivel Bolt as shown in Fig. 6 and feed wires from fixture through Slipfitter. Re-install Swivel Bolt.
  3. Reconnect the Swivel Bolt. Make the necessary connections as per NEC (Fig. 15.
  4. The Slipfitter fits a 2 3/8” O.D. Tenon. Place the Slipfitter over the Tenon and secure the fixture with(4) Set Screws on the side of the Slipfitter as shown in Fig. 7.
  5. To adjust the fixture angle of the Slipfitter, loosen the Swivel Bolt and swivel the fixture to the desired angle. The graduation of the Slipfitter Cover Plate can be used for guidelines to adjust the angle.

RAB-LIGHTING-A22-Field-Adjustable-Area-Lights-fig-6RAB-LIGHTING-A22-Field-Adjustable-Area-Lights-
fig-7

WALL MOUNT

(Accessory ordered separately – Model # A22WM, A22WMW, A22WMB)

  1. Remove the Adjustable Universal Arm by removing the fixture Securing Screw as shown in Fig. 4.
  2. Separate the Wall Mount Cover from the Wall Mount Box (Fig. 8).
  3. Orient the Wall Mount Box so that the “UP” Arrow is facing up as shown in Fig. 9.
  4. Secure the Wall Mount Box to a sturdy surface. Use appropriate hardware for the mounting surface (by others).
  5. Apply weatherproof silicone sealant around the edge of the mounting box and/or junction box. This is especially important with an uneven surface.
  6. Secure the Wall Mount Cover to the fixture with Securing Screw.
  7. Bring the fixture up to the Wall Mount Box and slide the Tether Cable from inside the Wall Mount Cover into the Keyhole Slot (Fig. 7 and 8) for hands-free wiring.
  8. Feed supply wires through the Wall Mount Box and wire the fixture using suitable wire connectors as per NEC (Fig. 15).
  9. Secure the wall Mount Box to the Wall Mount Cover using (4) Set Screws (provided) as shown in Fig. 10.

RAB-LIGHTING-A22-Field-Adjustable-Area-Lights-fig-9

FIELD ADJUSTMENT

Follow the instructions below to change the fixture Color Temperature (CCT) and/or Power (W) from the factory settings:

  • Factory Settings: A22-70/60/50W 70W / 4000K
  • A22-100/80/60W 100W / 4000K
  • A22-150/120/100W 150W / 4000K
  • A22-150X/120/100W 150W / 4000K
  • A22-200/180/160W 200W / 4000K
  • A22-320/280/250W 320W / 4000K
  1. Locate the Selector Switches on the fixture housing as shown in Fig. 11 and remove Plug.
  2. Select Color Temperature (CCT) and/or Power (W) by sliding the respective switch to the desired value (Fig. 12).
  3. After the switches are positioned to the desired setting replace the Plug.

LENS ACCESSORY

LENS accessories are sold separately.
(A22-150X (ONLY) includes TYPE III LENS installed, Type IV and Type V LENS included with fixture).

  1. Loosen Captive Screws (2) to open the fixture Door Frame as shown in Fig.13 and 14, and remove the pre-installed Lens and Silicone Gasket (do not discard the Gasket).
  2. Insert new Lens and Silicone Gasket, and ensure that the Lens and Silicone Gasket are positioned correctly. Close the fixture Door Frame and secure it with Captive Screws.

MVS MODELS

(optional remote sold separately for custom settings, CAT# MSR1).
Factory Settings:

  • Brightness: 100%
  • Hold Time: 1 Minute
  • Daylight: Disabled
  • Sensitivity: 100%
  • Stand-by dimming level: 20%
  • Stand-by time: 1 Minute

0-10V DIMMABLE WIRING

Universal voltage driver permits operation at 120V through 277V, 50 or 60 Hz. Units ordered with /480 suffix are 480V ONLY. For 0-10V dimming follow the wiring directions shown below (Fig. 15).

  1. Connect the black fixture lead to the LINE supply lead.
  2. Connect the white fixture lead to the COMMON supply lead.
  3. Connect the GROUND wire from fixture to supply ground. Do NOT connect the GROUND of the dimming fixture to the output.
  4. Connect the purple fixture lead to the (V+) DIM lead.
  5. Connect the pink fixture lead to the (V-) DIM lead.
  6. Cap the yellow fixture lead, if present. Do NOT connect.

RAB-LIGHTING-A22-Field-Adjustable-Area-Lights-fig-12

CLEANING & MAINTENANCE

CAUTION : Be sure the fixture temperature is cool enough to touch. Do not clean or maintain while the fixture is energized.

  1. Clean lens with non-abrasive glass cleaning solution.
  2. Do not open the fixture to clean the LED. Do not touch the LED.

TROUBLESHOOTING

  1. Check that the line voltage at the fixture is correct. Refer to wiring directions.
  2. Is the fixture grounded properly?
  3. Is the photocell, if used, functioning properly?

Note : These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.

Easy Answers

rablighting.com
Visit our website for product info
Tech Help Line
Call our experts: 888 722-1000
e-mail
Answered promptly – sales@rablighting.com
Free Lighting Layouts Answered online or by request
RAB WARRANTY : RAB’s warranty is subject to all terms and conditions found at rablighting.com/warranty.

References