Aprilaire E130C Dehumidifier User Manual

June 6, 2024
Aprilaire

Aprilaire E130C Dehumidifier

Aprilaire E130C Dehumidifier

SAFETY INSTRUCTIONS

WARNING

  1.  120 Volts may cause serious injury from electric shock. Disconnect electrical power before starting installation or servicing. Leave power disconnected until installation/service is completed.
  2. Dropping may cause personal injury or equipment damage. Handle with care and follow installation instructions.
  3. Sharp edges may cause serious injury from cuts. Use care when cutting plenum openings and handling duct work.

CAUTION

  1. Read all instructions before beginning installation.
  2.  Improper installation may cause property damage or injury. Read instructions before installation, service or maintenance.
  3.  Do not use in pool applications. Pool chemicals can damage the dehumidifier.
  4.  Do not use solvents or cleaners on or near the circuit board. Chemicals can damage circuit board components.
  5.  Wait 24 hours before running the unit if it was not shipped or stored in the upright position
  6.  Do not use dehumidification to prevent window condensation in the winter. To address window condensation, use ventilation to lower indoor humidity in the winter.
  7.  This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  8.  Children should be supervised to ensure that they do not play with the appliance.
  9. If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.

SPECIFICATIONS

  MODEL E130C
Unit Weight 98 lbs
Shipping Weight 115 lbs

Capacity

80°F, 60% RH Conditions

| ****

130 pints per day @ 310 CFM

Power

115 VAC, Single Phase, 60Hz

| ****

83A operating current


Dehumidifier Inlet Air Conditions

| Dehumidification: 50°F – 104°F, 40°F dew point minimum Ventilation: 40°F – 140°F, 0%RH – 99%RH (non-condensing)
Filter| MERV 8, washable
Airflow| EXTERNAL STATIC PRESSURE (“w.c.)| AIRFLOW (CFM)
00| 310
02| 270
04| 225
06| 175

0.7″ w.c. is maximum design external static pressure.

REMOVE SHIPPING BRACKET

IMPORTANT: Cut the strap securing the compressor shipping support bracket and remove the strap, shipping bracket screws, and bracket. See FIGURE 1.

Aprilaire E130C Dehumidifier FIG 1

LOCATION CONSIDERATIONS

  •  Allow sufficient clearance for filter removal and to prevent airflow obstruction
  • Electrical service access will require the removal of the side panel shown. Allow sufficient space for service on this side of the unit.

Aprilaire E130C Dehumidifier FIG 2

DRAIN INSTALLATION

The drain outlet on the dehumidifier can be hard piped using a 3/4″ PVC Slip x 3/4″ MNPT fitting and 3/4″ nominal drain tubing or the provided 3/4″ MNPT x 3/4″ hose barb fitting and 3/4″ clear PVC tubing can be used to drain the dehumidifier. Always maintain a constant downward slope from the dehumidifier to the drain and do not allow soft tubing to curl up which may result in air lock.

Note: PTFE thread seal tape is recommended for the threaded connection and hand tighten only. If hard pipe is used, PVC primer and cement is recommended for the slip fit connection.

A level surface is required to ensure proper drainage from the dehumidifier.
Always install the dehumidifier in a condensate pan when locating in or above a finished space. Adhere to local codes regarding draining of the condensate pan.

CONDENSATE PUMP AND FLOAT SWITCH
If a condensate pump is needed, install it in the condensate pan if installed.
Install a condensate overflow safety switch (i.e. float switch) in the condensate pan, remove the factory installed jumper wire between the Float Switch terminals on the control and wire the float switch to the dehumidifier as shown in FIGURE 3. Overflow safety switches on condensate pumps can be wired to the Float Switch terminals in a similar fashion.

Aprilaire E130C Dehumidifier FIG 3

SETTING THE DESIRED HUMIDITY LEVEL

  1. Plug in dehumidifier and turn on/off switch ON. See FIGURE 4.

  2.  Press the ON/OFF button to turn the dehumidifier control ON. The display will show the current setting, and the dehumidifier blower will turn on to start sampling the air.

  3.  The and  buttons allow the humidity level to be set from 40% to 80% relative humidity. Use the ON/OFF button to turn the dehumidifier ON or OFF.
    Set the control at 55%RH when first installed. Allow the dehumidifier to run until it reaches the setting before deciding if you want to change the setting. See FIGURE 5.
    • If you prefer the air to be more dry, decrease the humidity setting.
    • If you prefer the air to be less dry, increase the humidity setting.

  4.  After three (3) minutes of sampling, the measured humidity will be compared to the setting:
    a. If the humidity is above the setting, the dehumidifier compressor turns on and “AIR SAMPLING” will be replaced by “DEHUMIDIFYING”. The compressor remains on until the measured humidity falls 3% RH below the setting. See FIGURE 6.
    b. If the measured humidity is below the setting, the blowers turn off and the display returns to showing the RH setting.

  5. The dehumidifier will sample again every 60 minutes, or at any time if the humidity setting is lowered.

Aprilaire E130C Dehumidifier FIG 4

Your comfort is the best measure of how to adjust your setting. When first installed, your dehumidifier has to remove all the moisture that is initially in your home. The home acts like a sponge so the moisture in the materials of your home is at the same level as the air. After drying the air, the materials of the home will release moisture back into the air until they are again at the same level. As a result, it is not uncommon for the dehumidifier to operate for an extended period when first installed.

Your dehumidifier is equipped with two features that protect against unwanted energy consumption. Defrost is a normal operating mode that helps to prevent significant ice formation on the refrigeration system coil. The dehumidifier display will show “DEFROSTING” when operating in this mode. This mode can occur when there is not enough air moving through the dehumidifier or if the temperature and/or humidity of the incoming air is too low.

The second protection feature is the E8 code. E8 on the dehumidifier display indicates that the air entering the dehumidifier is below 50°F or above 104°F, or the dew point of the incoming air is below 40°F. There would be a significant reduction in dehumidifier efficiency if the dehumidifier operated outside of these conditions. Low dew point conditions can be seen in some basements or crawl spaces and usually occur in the Winter and Spring months. The dehumidifier continues to monitor the incoming air and when the conditions are within the operating range, E8 will be removed from the display and dehumidification will begin as needed.

ENERGY SAVINGS TIPS

Energy Savings Tip #1: Adjust the humidity setting to be as high as is comfortable to reduce dehumidifier run time. If it feels clammy or “smells musty”, lower the humidity setting. To save energy, turn the dehumidifier to OFF when you open your windows, just as you would with air conditioning.

Energy Savings Tip #2: If vacating your home for an extended period in the summer, set the RH at 55% and set your thermostat as high as you are comfortable setting it to in the cooling mode. Consult with appropriate professionals regarding the highest temperature that is safe for your pets or possessions. This will keep the humidity at a controlled level while minimizing the amount of cooling energy used.

MAINTENANCE

CLEAN OR REPLACE THE AIR FILTER
After initial installation the air filter should be checked and cleaned every 6 months. The CLEAN FILTER service reminder will display on the on-board control screen every 6 months. To clear the service message, press and buttons simultaneously for 3 seconds. Filter Cleaning Procedure

  1. Turn the ON/OFF switch OFF.
  2.  Remove the filter access door from either side of the dehumidifier.
  3.  Slide the filter out of the dehumidifier.
  4. Flush the filter with warm water and a mild detergent solution.
  5.  Shake off the excess water from the filter.
  6. Replace the filter, making sure the filter is secured in both the top and bottom filter rails.
  7. Replace the filter access door.
  8. Turn the ON/OFF switch ON.
  9. Press the and buttons simultaneously for 3 seconds to clear the service message.

Aprilaire E130C Dehumidifier FIG 9 CHECK THE DRAIN
The drain should be checked annually to ensure there are no blockages or air lock in the drain system. If the unit is not draining properly, have it checked by a qualified service professional.

CAUTION

Do not use spray solvents or cleaners on or near the inlet side of the dehumidifier. If desired, apply cleaner to a cloth and use to clean the cabinet.

DUCT COLLAR INSTALLATION

HORZONTAL DISCHARGE:

  • Use the screws in the parts bag to attach the duct collars to the inlet and outlet of the dehumidifier. The outlet collar has a backflow damper.
  • The outlet duct collar may be attached to the top or end of the unit. Move the outlet cover to the location not being used. See FIGURE 7.
  • Make sure there are no bends in the ductwork coming off the outlet for a minimum of 4″. This will ensure that the ductwork will not interfere with the backflow damper function.

VERTICAL DISCHARGE:
Use the screws provided in the parts bag to attach the duct collars:

  • When the dehumidifier requires a ducted vertical discharge, remove the top access panel and remount on the outlet of the unit. Install the outlet duct collar with backflow damper on top of the unit. See FIGURE 7.

CONTROL LOCATION
The on-board control can be located on the top of the dehumidifier or can be relocated to the front of the dehumidifier if the control cannot be seen/accessed in the top orientation. It may also be rotated 180 degrees in either orientation as shown in FIGURE 9.

TO MOVE THE CONTROL:

  1.  Remove the front control panel cover.
  2.  Remove the filter access door and filter.
  3.  Detach the on-board control by removing the four (4) screws around the control. Note: Use one hand to support the bottom of the on-board control when removing.
  4. Keep the control in the unit and relocate to the front access hole.
  5. Secure the control with the same four screws used to attach the control to the top of the unit.
  6.  Secure the control panel cover to the top of the unit.

Aprilaire E130C Dehumidifier FIG 11 Aprilaire
E130C Dehumidifier FIG 12

LIMITED WARRANTY

Your Research Products Corporation Aprilaire® Dehumidifier is expressly warranted for five (5) years from date of installation to be free from defects in materials or workmanship.
Research Products Corporation’s exclusive obligation under this warranty shall be to supply, without charge, a replacement for any component which is found to be defective within such five (5) year period and which is returned not later than thirty (30) days after said five (5) year period by you to either your original supplier or to Research Products Corporation, Madison, Wisconsin 53701, together with the model number and installation date of the dehumidifier.

THIS WARRANTY SHALL NOT OBLIGATE RESEARCH PRODUCTS CORPORATION FOR ANY LABOR COSTS AND SHALL NOT APPLY TO DEFECTS IN WORKMANSHIP OR MATERIALS FURNISHED BY YOUR INSTALLER AS CONTRASTED TO DEFECTS IN THE DEHUMIDIFIER ITSELF.

IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED IN DURATION TO THE AFORESAID FIVE YEAR PERIOD. RESEARCH PRODUCTS CORPORATION’S LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, OTHER THAN DAMAGES FOR PERSONAL INJURIES, RESULTING FROM ANY BREACH OF THE AFORESAID IMPLIED WARRANTIES OR THE ABOVE LIMITED WARRANTY IS EXPRESSLY EXCLUDED. THIS LIMITED WARRANTY IS VOID IF DEFECT(S) RESULT FROM FAILURE TO HAVE THIS UNIT INSTALLED BY A QUALIFIED HEATING AND AIR CONDITIONING CONTRACTOR. IF THE LIMITED WARRANTY IS VOID DUE TO FAILURE TO USE A QUALIFIED CONTRACTOR, ALL DISCLAIMERS OF IMPLIED WARRANTIES SHALL BE EFFECTIVE UPON INSTALLATION.

Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above exclusion or limitations may not apply to you.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

WARRANTY REGISTRATION

Visit us online at www.aprilaire.com to register your Aprilaire product. If you do not have online access, please mail a postcard with your name, address, phone number, email address, product purchased, model number, date of purchase, and dealer name and address to: Research Products Corporation, P.O. Box 1467, Madison, WI 53701.
Your warranty registration information will not be sold or shared outside of this company.

AprilairePartners.com
P.O. Box 1467
Madison, WI 53701-1467
800.334.6011 F: 608.257.4357
Printed in USA
©2021 Aprilaire – Division of Research Products Corporation 10015489 B2209223B 3.21

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Aprilaire User Manuals

Related Manuals