SEWOSY EF150ENCCTC CA Mortice Electromagnetic Lock Installation Guide

June 1, 2024
SEWOSY

SEWOSY EF150ENCCTC CA Mortice Electromagnetic Lock

SEWOSY-EF150ENCCTC-CA-Mortice-Electromagnetic-Lock-
product

Specifications

  • Model: EF150ENCCTC APPROX
  • Power Supply: 12V DC, 480 mA
  • Operating Voltage: 24V DC
  • Max Holding Force: 150 daN

Product Usage Instructions

General Instructions:

Use this equipment only for an adapted application. The manufacturer cannot be held responsible for possible damage caused when usual security requirements are not fulfilled. Mounting, maintenance, and repair must be carried out by skilled and authorized staff.

Installation:

Insert the rubber washer (h) between the steel washers (g) and do not screw too tightly to keep the armature plate slightly loose.

Connection:

Make sure to observe correct polarity. Use the correct input voltage as specified. Check jumper settings before connecting the lock to its power supply. Incorrect polarity, wrong input voltage, or wrong jumper position may damage the product. Check for perfect alignment between the armature plate and magnet.

Maintenance:

Regularly check the alignment of the armature plate and magnet. Ensure proper voltage supply and polarity. Clean the lock and surrounding area regularly to prevent debris buildup.

FAQ

Q: What do I do if the lock is not functioning properly?

A: Check the power supply voltage, ensure correct polarity, and verify the alignment between the armature plate and magnet. If issues persist, contact a qualified technician for assistance.

Q: Can I use this lock for outdoor applications?

A: This lock is suitable for indoor use only. Exposure to outdoor elements may cause damage and void the warranty.

More Info

SEWOSY-EF150ENCCTC-CA-Mortice-Electromagnetic-Lock-fig
\(1\)

(*) Forces de retenue maximales pour des mises en oeuvre respectant les conditions de pose optimales Maximal theoretical holding forces for implementations fulfilling optimal installation conditions

Parts

SEWOSY-EF150ENCCTC-CA-Mortice-Electromagnetic-Lock-fig
\(2\)

GENERAL INSTALLATION INSTRUCTIONS

  • Use this equipment only for an adapted application.
  • The manufacturer cannot be held responsible for possible damage caused when usual security requirements are not fulfilled.
  • Mounting, maintenance and repair must be carried on by a skilled and authorized staff

SEWOSY-EF150ENCCTC-CA-Mortice-Electromagnetic-Lock-fig
\(3\)

INSTALLATION DIAGRAMSSEWOSY-EF150ENCCTC-CA-Mortice-Electromagnetic-Lock-
fig \(4\)

Insert the rubber washer (h) between the steel washers (g) and do not screw too tighltly to keep the armature plate slightly looseSEWOSY-EF150ENCCTC-CA-
Mortice-Electromagnetic-Lock-fig \(5\)

Dimension

SEWOSY-EF150ENCCTC-CA-Mortice-Electromagnetic-Lock-fig
\(6\) SEWOSY-EF150ENCCTC-CA-Mortice-
Electromagnetic-Lock-fig \(7\)

CONNECTION

Caution :

  • Make sure to observe correct polarity.
  • Use correct input voltage as specified.
  • Check jumper settings before connecting the lock to its power supply. Incorrect polarity, wrong input voltage or wrong jumper position may damage the product. These failures are not covered by the product warranty.
  • Check for perfect alignment between the armature plate and magnet.