- Before using the device, please read these instructions carefully to ensure proper usage and store them in a safe place during the entire lifetime of the product.
- To prevent injury, this apparatus must be securely attached to the ceiling/wall in accordance with the installation instructions.
- Batteries should not be exposed to excessive heat such as sunshine, fire or the like.
- Do not paint or cover the smoke alarm.
LED, Acoustics and Button Rules
Overview visual & acoustic signals
Operation mode| Visual signal (flash)| Acoustic signal (beep)|
Description mode
---|---|---|---
Normal| 1 x per 40 second| None| Device is functioning properly
Test| 1 x per second (3x)/ pause of 1.5 seconds| 1x per second (3x) pause of
1.5 seconds| Device is tested
Alarm| 1 x per second (3x)/ pause of 1.5 seconds| 1x per second (3x} pause of
1.5 seconds| Device is detecting smoke
Alarm silence| 1 x per 8 seconds| None| Smoke alarm signal is muted
Low battery warning| 1 x per 40 seconds| 1x per 40 seconds| Battery is
running low
Low battery warning silence| None| None| Low battery
warning is muted
Sensor fault warning| 1 x per 40 seconds| 1x per 40 seconds| Sensor is not
functioning properly
Buzzer fault warning| 2 x per 40 seconds| None| Buzzer is not functioning
properly
Installation Guide
Product description and intended use
This is smoke alarm with an optical sensor for installation in residential
buildings, apartments and rooms with residential-like use. Smoke alarms are
designed to provide an early warning of fire smoke and fires to persons
present, so that these persons can react appropriately to the hazardous event.
Always consult local regulations for smoke alarms.
Where to install a smoke alarm
Smoke alarms must be installed in such a way that they can be reached
unhindered by the fire smoke so that fires can be reliably detected during the
development phase.
- Install at least in sleeping areas (especially children’s rooms).
- Install at least in escape rooms.
- In the middle of the ceiling of a room.
- At least 50cm away from the wall and other objects.
- Maximum installation height of 6 meters.
- If ceiling installation is not possible, the smoke alarm can be installed on the wall. The distance to the ceiling should be between 30 and 50 centimeters.
Where to install a smoke alarm in rooms with special geometries
-
Corridors with a maximum width of 3m: Max. 15m between 2 smoke alarms. Max. 7.5m to the front side of the gallery and smoke alarms at edges/crossings of corridors.
-
Rooms with sloping ceilings:
– Ceiling inclination is > 20° to the horizontal: Smoke alarms must be installed at least 0.5m and at most Im from the ceiling top.
– Partial roof slopes: If the flat ceiling is < Im wide, consider as ceiling inclination is of > 20°. If the flat ceiling is >Im wide, consider as flat ceiling. -
Rooms with subdivided ceilings:
– Height of the subdivisions is < 0.2m: Beams without consideration: smoke alarm may be installed on the beams or the ceiling.
– Height of subdivisions is > 0.2m and area of ceiling panels > 36m?: Smoke alarm should be installed in each ceiling panel.
– Height of subdivisions > 0.2m and area of ceiling panels < 36m: Individual ceiling without consideration.
Where not to install a smoke alarm
- In an environment with a high risk of draught (e.g. close to air conditioning, fans and ventilation outlets). The movement of air can impair the penetration of fire smoke into the smoke alarm.
- Areas where combustions regularly occurs, such as kitchens.
- Areas with high humidity such as bathrooms, or close to devices such as dish washers or washing machines.
Activation
Before commissioning the smoke alarm, it is important to activate it and test it for correct operation.
- Press the test button and hold it for approximately 3 seconds until the led indicator lights up. Release the test button immediately after this, The smoke alarm will generate a beep to indicate that it’s activated.
- Test the correct activation of your smoke alarm by pressing the test button. If no sound is generated, the smoke alarm is not activated properly and should not be used!
Mounting
- Place the mounting plate on the desired installation location and mark where the holes should be drilled.
- Drill two holes with a diameter of 5 millimetres.
- Push the plastic plugs into the holes.
- Remove the fixing plug from the mounting plate (if necessary, use a screw driver for this).
- Insert the screws into the mounting plate, and tighten them firmly into the plugs.
- Place the smoke alarm on the mounting bracket and secure it by turning it clockwise.
- Insert the fixing plug into the hole between the mounting plate and the smoke alarm to fix your alarm.
- Test the correct operation of your smoke alarm by pressing the test button. If no sound is generated, the smoke alarm is not functioning properly and should not be used!
Working Mode
Alarm silence facility
When the smoke alarm has detected smoke and turns into the alarm mode, you
can mute the alarm for 10 minutes by pressing the test button. After that, the
smoke alarm automatically resets and returns into the normal operation mode.
If there are still particles combustion in the air, the smoke alarm will turn
into the alarm mode again.
WARNING: Use this function only if you are absolutely sure that the alarm was
triggered by a Known problem, e.g. smoke develooment during cooking.
Low battery mode
When the battery is running low, the smoke alarm will indicate this with a
repetitive beep and flash for approximately 30 days.
WARNING: This smoke alarm is equipped with a non-replaceable battery.
When this warning occurs, replace the device as soon as possible! The acoustic
low battery warning signal can be muted for ten hours by pressing the test
button. The smoke alarm is still functioning and able to detect smoke when
it’s in this mode.
Fault warning mode
The smoke alarm runs through a periodical self-test. When the smoke sensor
is not functioning properly, it will turn into the sensor fault warning mode.
Try cleaning the smoke alarm (see paragraph “Maintenance”) or replace the
smoke alarm! If the buzzer is not working correctly, the device will turn into
the buzzer fault warning mode. Please immediately contact the manufacturer or
replace the smoke alarm when this occurs.
Night mode
This smoke alarm has an automatic night mode. In dark rooms, the led signal
will be dimmed to prevent disturbance of the night’s sleep.
Maintenance
- This smoke alarm is equipped with a self-testing mechanism. We recommend to test the smoke detector manually at least once every three months by using the test facility. If the smoke alarm functions correctly, it will generate a loud beep. Due to the loudness of the alarm, make sure that you always stand at arm’s length distance from the unit when you are testing. If the smoke alarm does not generate an acoustic signal, the smoke alarm must be replaced immediately!
- Clean the smoke alarm at least once per month to remove dirt, dust or debris. Use a vacuum cleaner with a soft brush and vacuum all sides and covers of the smoke alarm. Do not remove the top cover of the smoke alarm to clean it inside.
- Do not attempt to repair this smoke alarm. If the smoke alarm shows a damage related to its functionality, it must be replaced!
- Trouble shooting: False alarm is often caused by dust or steam.
Disassembling
To disassemble the smoke alarm, take a screw driver and push it into the
mounting hole. Then, turn the smoke alarm counterclockwise to remove it from
the mounting bracket.
Recycling and disposal
The WEEE symbol means that this product and batteries must be disposed separately from other a household waste. When they reach their end of life, take them to a designated waste collection point in your area to guarantee a safe disposal or recycling. Protect the environment, human health and natural resources! Membership in eco-organization Ecologic.
Service
Customer service: support@meross.com
The CE mark affixed to this product confirms its compliance with the European
Directives which apply to the product and, in particular, its compliance with
the harmonized specifications of standard EN 14604:2005 relating to
Construction Products Regulation 305/2011.
Product Specifications
Detection method: | Optical sensor |
---|---|
Power supply: | Sealed battery (8V DC) |
Battery lifetime: | 10 years |
Alarm volume: | > 85 dB(A) at 3 meters |
Alarm sensitivity: | 0.105 – 0.155 dB/m |
Monitored area: | 40m? |
Operating temperature: | O0O°C-40 °C |
Operating humidity: | <93% |
Date of replacement : | See product label |
Individual alarm indicator: | Yes |
Alarm silence facility: | Yes |
Low battery warning: | Yes |
Low battery silence facility: | Yes |
Installation in leisure | |
accommodation vehicles: | Yes |
Mounting location: | Ceiling or wall |
Interconnectable: | No |
Warranty
Meross products are covered by a 36 months limited warranty from the date of
its original purchase. If any problems occur, please contact
support@meross.com for help.
We can only provide aftersales service for products that are sold by Meross or
Meross authorized retailers and distributors.
Disclaimer
This manual is for reference only. As specific functions and product image
may differ slightly from what they are, the physical product shall prevail.
SIMPLE DEVICE SIMPLIFY YOUR LIFE
Email: support@meross.com
Website: www.meross.com
Manufacturer: Siterwell Electronics CO., Limited
Address: No. 666 Qingfeng Road, Jiangbei District, Ningbo, Zhejiang Province,
China, 315034
CET PRODUCT SERVICE LTD. (for authorities only)
Chase Business Centre, 39-41 Chase Side London N14 5BP UK
MADE IN CHINA INDOOR USE ONLY
This manual is for reference only. As specific functions and product image may differ slightly from what they are, the physical product shall prevail.
ESSENTIAL CHARACTERISTICS: PASSED
Nominal activation conditions/ Sensitivity, Response delay (response time) and
Performance under fire condition – Operational reliability – Tolerance to
supply voltage – Durability of operational reliability and response delay,
temperature resistance, vibration resistance, humidity resistance, corrosion
resistance, electrical stability Download the Declaration of Performance at
www.meross.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>