Easy Installation
- PVC Vent runs up to 70′ (2″), 150′ (3″)
- Easy set up with full text digital display and no dip-switches
- Field gas convertible from natural gas to LP conversion kit included
Ready for Retrofits
- Allows flex venting through existing B-vent up to 50′
- 1/2″ Gas line compatibility (subject to local code)
- Approved for installations in Manufactured Home (Mobile Home) environments
Key Features
- Stainless steel Primary and Secondary heat exchangers provide increased efficiency and durability
- Hot-start programming™ ensures the unit is in a ready state between back-to-back usage, avoiding any cold water bursts –Ruud® Exclusive!
- Built-in Recirculation pump for instant hot water at the tap (SR models)
- Built-in Eco Net® wifi capability for direct control from your device (optional for S models)
Specifications
Ruud Model Number| RUTGH-S84i RUTGH-SR84i| RUTGH-S10i RUTGH-
SR10i| RUTGH-S11i RUTGH-SR11i
---|---|---|---
Gas Input Rate| MAX| 157,000 BTU/h| 180,000 BTU/h| 199,900 BTU/h
MIN| 11,000 BTU/h| 11,000 BTU/h| 11,000 BTU/h
Uniform Energy Factor (UEF)| 0.96
Gallons Per Minute (GPM)| MAX (35°F)| 8.4| 10.1| 11.2
45°F Rise| 6.9| 7.9| 8.8
67°F Rise| 4.6| 5.3| 5.9
Number of Bathrooms 1| | |
Temp. Range| 85°F – 140°F
Temp. Setting from Factory| 120°F
Installation Type| Indoor (Outdoor Conversion Kit sold separately: RTGH-
SX)
Fuel Type| Compatible with Natural Gas and LP (ships NG with LP
conversion kit included)
Heat Exchanger Material| Primary: Stainless Steel – Secondary: Stainless
Steel
Minimum Activation Flow| 0.4 GPM
Minimum Continuous Flow| 0.26 GPM
Maximum Altitude| 10,200 ft.
Ultra Low NOx| Yes (SCAQMD compliant)
Warranty| 15 Year Heat Exchanger – (w/ registration) 12 Year Heat
Exchanger – (w/o registration) 5-Year Parts | 1-Year Labor
Model Number| RUTGH-S| RUTGH-SR
---|---|---
Height| 28-9/16″
Width| 17-5/16″
Depth| 13-11/16″
Weight| 77.6lbs| 86lbs
Venting Diam. Allowed| 2″ / 3″
Max. Single Vent Run (straight pipe)| 70 ft (2″)/ 150 ft (3″)
Venting Materials| Sched. 40 PVC, CPVC, PP
Common Venting (max. units)| 2 units3
Flex Venting| Allowed: 2″ up to 50′
Manifold Controls (max. units)| Up to 20 units without external control
required4
Controls| Built-in digital display with full-text menus
Power Supply| 120V 60Hz
Max. Power Consumption| 85W (Normal use), 0.7Amps 132W (Anti freeze
only), 1.1Amps 3.5W (Standby), 0.03Amps5| 100W (Normal use), 0.83Amps 200W
(Anti freeze), 1.67Amps 3.5W (Standby), 0.03Amps5
Gas Connection| 3/4″ NPT
Hot Water Connection| 3/4″ NPT
Cold Water Connection| 3/4″ NPT
Condensate Connection| 1/2″ NPT
Vent Connections Diameter| 2″ Band Connections (Adapter required to vent
with 3″ PVC from unit)
Clearances
Top / Bottom| 12″
Front| 1/2″6
Sides| 1/2″
Back / From Vent Pipe| 0″
Recirculation Length (SR Models)
Pipe Diameter| Max. Recirculation Loop
3/4″| 400 ft.
1/2″| 100 ft.
1 Based on simultaneous showers using 2.5 GPM flow rate pre-mixed with cold water line. Flow rates vary depending on temperature of incoming cold water and water heater set temperature. Refer to flow rate curves for accurate sizing. 2 For indoor application, this is the temperature of outdoor intake air. 3 External check valve required for installation. 4 Manifolds with standard RJ25 communication cables. 5 If anti freeze is on and combustion is on, total W will be 217W (85+132). 6 Recommended 24″ clearance for service.
Water Heater Flow Rate Curves
Venting
SINGLE UNIT: MAX. EQUIVALENT VENT LENGTHS – STRAIGHT PIPE
Number of 90 Elbows
|
Max Length 2″ straight pipe
|
Max. length 3″ straight pipe
0
| 70 ft. (21.3 m)| 150 ft. (45.7 m)
1
| 64 ft. (19.5 m)| 145 ft. (44.2 m)
2
| 58 ft. (17.7 m)| 140 ft. (42.7 m)
3
| 52 ft. (15.8 m)| 135 ft. (41.1 m)
4
| 46 ft. (14.0 m)| 130 ft. (39.6 m)
5
| 40 ft. (12.2 m)| 125 ft. (38.1 m)
6
| 34 ft. (10.4 m)| 120 ft. (36.6 m)
Venting Materials Allowed: Schedule 40 PVC, CPVC, PP
Equivalent Ft. of Elbows
|
2″ Pipe
|
3″ Pipe
90° Elbow| 6 ft (1.83 m)| 5 ft (1.52 m)
45° Elbow| 3 ft. (0.9 m)| 2.5 ft. (0.75 m)
Min. Vent Length Straight Pipe
Number of 90° Elbows| Min. Length 2″ 3″ pipe
1| 1.0 ft (0.3 m)
COMMON VENTING
# of Water Heaters
|
3″ Common Vent
2
|
60 ft.
SINGLE UNIT: Max. Flex Venting
Max Length 2″ flex vent
50 ft.
Dimensions
TOP VIEW
BOTTOM VIEW
Hanging bracket, bird screens, LP gas conversion kit are included with water heater.
Parts & Accessories
Condensate Neutralizer
|
Non-Return Valve
| Flex Vent Kit| Pipe Cover|
Horizontal Vent Termination
|
Concentric Vent Termination
|
AllClear ® **Water Treatment System**
|
Isolation Valve Kit
|
Manifold Cables
|
Outdoor Conversion Kit
|
Crossover Valve
---|---|---|---|---|---|---|---|---|---|---
SP12151 (optional)
|
SP21088 ****
|
SP21091
|
AP20473
| 2″ US: SP21069G 3″ US: SP21069E ****
| 2″ – SP20897
3″ – SP20245 |
RTG20251
| RTG20220AB
| RCPN-AMP03 0013111101-0003 (48″)
| RUTGH-SX
| RTG20285
Documents / Resources
| RUUD
RUTGH-S Tankless Water
Heaters
[pdf] Installation Guide
RUTGH-S, Tankless Water Heaters, RUTGH-S Tankless Water Heaters
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>