CG THUNDER 80 Air Cooler Instruction Manual

June 13, 2024
CG

AR COOLER
INSTRUCTION MANUAL
Read his manual carefully before operaion
Pictures in this manual are for reference only, the product n kind prevail.

MODEL : THUNDER 80
This instruction manual contains important information & recommendations
that we would ask you fo comply
with to obtain best results from your products. CG THUNDER 80 Air Cooler -
icon 1

KNOW YOUR CG AIR COOLER

CG THUNDER 80 Air Cooler - KNOW YOUR CG AIR COOLER

TECHNICAL SPECIFICATIONS

DESCRIPTION THUNDER 80 .
VOLTAGE 220-240V, 50Hz AC
POWER CONSUMPTION 175 watt
SPEED LEVELS THREE
AIR DEFLECTION FOUR WAY
WATER TANK CAPACITY 80 liter
COOLING MEDIA WOOD WOOL

HONEY COMB
AIR DELIVERY| WOOD WOOL| 3800m3 / Hr.
HONEY COMB| 4000m3 / Hr.
DIMENSIONS (L x W x H) cm| 65.0 x 51.0 x 114.0
WEIGHT W/O WATER| 16.5 kg

SAFETY : Eating i povided. (1 sl models ony)

INSTALLATION

CG THUNDER 80 Air Cooler - INSTALLATION

  1. Place your Air Cooler at least 10 cm away from wallor any other obstruction. The Cooler should be placed near a window / door to alow in fresh air.
  2. Always ensure that there s another open window / door through which warm air can exhaust rom the room. Constant air change is very essential for fresh air caoling by your Al cooler.
  3. Plug in the mains cord of your Cooler to a wall socket. Ensure the Supply of socket should be in OFF Positon while plugging.
  4. While plug in the mains cord please ensure that phase (L) & neutral (N) of the mains cord should match with the phase and neulral of the socket as per standard.

GETTING STARTED

  1. Install the cooler as per Installation procedure.
    CG THUNDER 80 Air Cooler - the cooler

  2. FILLING OF WATER
    : Just fill water tank (as per tank capacity) of your air cooler through the water inlot port, The wat level will be viewed through lens. It s advisable (o use tumbler 1o fil the wate to ensure no spillage. (Ensure the power point is OFF while filing waler), If filed water excesses the tank capacity water willspil out from over flow spout.

  3. POWER SUPPLY: Ensure that your Aircooler is plugged ino specified Voltage & Frequency outlet and Switch ‘ON’ the power supply.

  4. PRE SOAKING: : Before putting on the Cooler fan, it s advisable to run pump for few minutes by rotating FUNCTION KNGS, This will ensure uniform Soakingofcooling media & avoid sprikling of water fany.

  5. BETTER PERFORMANCE : For better air blast run the cooler on high speed. Run the cooler on low speed to get better cooling & Tow noise level

  6. CONTROLS :
    A) Set the POWER Knob to ON position. Set the SPEED Knob to desired levelviz.WINDY,GENTLE,QUIET(Le.high,mediumlow,)of air delivery. If you want to use the cooler in COOL mode;Set the FUNCTION Knob to COOL / SWING position to obtain continuous horizontal oscillation of air.
    B) If you need a focused blast of cool air, wait for the blast to focus in the direction you desire and then turn the FUNCTION Knob to COOL Position.
    C) When you want to use the cooler in FAN mode; set the FUNCTION Knob to SWING position to obtain continuous horizontal oscillation of air. If you need to focused blast of fresh air, wait for the blast to focus in the direction you desire and then turn the FUNCTION Knob to OFF Position.
    D) AIR FLOW KNOB directs the flow of air UP/DOWN.

SAFETY PRECAUTIONS

  • Always disconnect mains supply before filling water.
  • Do not fill the water, after overflow.
  • Do not try to fill the water into the cooler when in operation.
  • Do not move the cooler rapidly when there is water in the tank.
  • Always disconnect mains before opening filter net or panels.
  • Be particular & careful when using the cooler near curtains. Keep safe distance from the curtains.
  • Children must not be allowed to operate / play with cooler.

TROUBLE SHOOTING

  • If Air cooler fails to operate, please check the following before calling for service.
  • Please check that there is electric supply at the power point.
  • Please check that the power point is switched ‘ON’ and that the plug is in its place correctly.
  • Please check that the controls are set properly.

OPERATIONAL CARE AND REGULAR MAINTENANCE

OPERATIONAL CARE :

  1. When your Air Cooler is not in operation, make sure to switch all the switches to OFF Position.
  2. Operate the buttons gently.
  3. Do not wipe the cooler with harsh chemicals, scrubbing powder or thinner as they will damage the body.
  4. Do not keep heavy load on the top of your Air Cooler.
  5. Do not add any bleaching agents into the water in the tank.
  6. Before moving or relocating the cooler ensure that the mains cord is unplugged and that the water tank is empty.
  7. Do not immerse the unit in water. 8) Do not use any cleaning chemicals such as detergents and abrasives.
  8. Do not allow the interior (special for the PCB) to get wet as this could create a hazard.

REGULAR MAINTENANCE : Periodic maintenance helps to keep your Air Cooler in good condition.

  1. It is recommended to drain the Cooler and clean the cooling pads every month.
  2. Replace the HONEYCOMB PAD once in two / three years & replace the cooler pad once a year in case of WOOD WOOL.
  3. After the summer season ensure that the water is drained off completely & pads are dried before storage.

CLEANING OF COOLER BY DRAINING WATER : Pull to remove the drain plug given to the water tank to drain the remaining water from the tank. After draining, push to fix drain plug properly. For better performance & longer life of pads, it is advisable to drain water on regular basis.

KEY FEATURES OF AIR COOLER

  • STURDY DESIGN
    Air coolers are designed to have excellent aesthetics & are made of sturdy thermoplastic material having excellent finish & corrosion free life.

  • SPECIAL HONEYCOMB PADS
    These are specially designed for Air cooler, made up of Antifungus environmental friendly cellulose based paper. The construction of the same is such that, it gives maximum contact surface with air & water. Which ensures efficient evaporation of water & gives better cooling effect.
    Minimum two three drain cycles to be carried out on purchase of the air cooler to eliminate smell of Honeycomb pads.

  • SPECIAL WOOD WOOL PADS ( In select models only)
    Himalayan pine wood wool provided for odorless & fresh cool air. The unique construction of these pads gives maximum contact surface with air & water. This ensures efficient evaporation of water &  giving very effective cooling.

  • WATER LEVEL INDICATOR
    An easy to view water level transparent lens provided on the tank at front face, lets you keep a check on the water level in the tank.

  • TOUGH & ELEGANT FAN
    Specially designed for optimum efficiency having blades of non-corrosive material with three speed option.

  • FREE WHEELING CASTORS
    The cooler is mounted on castors which makes it convenient to wheel around from one place to another, even a child can move it around.

CG THUNDER 80 Air Cooler - icon 2

https://www.cginspiringlife.com/

IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCEWITH EC DIRECTIVE 2002/96/EC.
At the end of its working life, the product must not be disposed of as urban waste. It must be taken to a special local authority differentiated waste collection centre or to a dealer pro-viding this service.
Disposing of a household appliance separately avoids possible negative consequences for the environment and health deriving from inappropriate disposal and enables the constituent mate-rials to be recovered to obtain significant savings in energy and resources.As a reminder of the need to dispose of household appliances separately, the product is marked with a crossed-outwheeled dustbin.

Visit us at: www.cginspiringglife.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals