DESCRIPTION

Pair of outdoor photocells with battery transmitter and wired receiver, infrared beam, adjustable.
The IRIS BAT version allows the synchronization of up to 8 pairs of photocells. IRIS BAT ADV version does not allow synchronization.

APPLICATION POSSIBILITIES

Pair of photocells for the protection of gates subject to the installation of automated and remotely controlled doors and gates. If the door control system performs the photocell diagnostic check before each movement, this product allows to realize a protection system type PL “c” -CAT 2 according to EN ISO 13849-1:2015. The diagnostic check consists of removing the power supply to the photo-receiver for at least the reset time () and verifying that the output contact is in the alarm position. After that the power can be restored.
Any installation and use different from what is indicated in the following manual are prohibited.**

PRODUCT VERSIONS

| IRIS BAT| IRIS BAT ADV
---|---|---
Synchronization| YES (MAX 8 PAIRS)| NO
Signal Test| YES| NO

 TECHNICAL CHARACTERISTICS

| RX| TX
---|---|---
Supply voltage| 12 … 35 Vac/Vdc| 2 x battery AA 1,5V
Absorption| <300mW (~11mA @ 24Vdc)| 110 uA
Battery life (TX)| 12 ÷ 24 months
**Maximum range *| 10 m
Wave length| 950 nm
Relay output| MAX 1A 24Vdc| –
Detection time of the obstacle| 100 ms
Reset time **| < 200 ms
Insulation class| III
Protection class| IP 54
Environmental operating conditions**| TA: -10…+55 °C RH max 90% non- condensing

  • ATTENTION! In case of rain, snow, fog or dust the flow rate may decrease.
    ** : Time the receiver takes to pass the relay output from the consent state to the alarm state, in case of power failure.

DETAILS

(FIG.1)

Description

A Holes for fixing on the surface.
B Hole for cable passage.
C Adjustable support locking device.
D Optics with adjustable support.
E Battery holder.
F LED to signal alignment.
G Input for the connection of a mechanical safety edge, contact

Normally
Closed. Remove the bridge if used.
H| Clamp for synchronized operation.
I| DIP-SWITCH selector for configuration.
L| Power supply voltage input.
M| Relay output.

INSTALLATION

Please read the safety warnings in this manual carefully before installing.

  1. Drill the bottom of the cable box (FIG.1-B).

  2. Fix the bottom of the box to the wall, bearing in mind the dimensions indicated in FIG.2.

  3. Determine the orientation of the optical medium to align the optics of the receiver and transmitter (FIG.4 and FIG.5).

  4. Tighten the screws of the locking device of the mobile holder (FIG.1-C).

  5. Insert the batteries into the transmitter (FIG.1-E).

  6. Connect the power to the receiver (FIG.1-L).

  7. Connect the relay output of the receiver to the associated product (FIG.1-M).

  8. Give power supply voltage to the receiver and check the correct alignment and operation of devices:
    RX| FREE PASSAGE / CONSENT| PASSAGE OCCUPIED / ALARM
    ---|---|---
    LED| OFF| ON
    3 – 4| open-circuit| close-circuit
    3 – 5| close-circuit| open-circuit

  9. . Close the front cover with supplied screws.

NOTICE OF REPLACEMENT OF BATTERIES

When the batteries on the transmitter are almost empty and reach a voltage of 2.1V, the receiver warns the user of the imminent need to replace the batteries by flashing continuously every second of the LED (FIG.1-F). During these reports the system is still working, but it is advisable to consider whether to proceed to the replacement of the batteries before the automation stop occurs.

CONFIGURING THE SYNCHRONIZATION

This option is not available in IRIS BAT ADV version.

Synchronised operation is required if multiple pairs of photocells are installed on the same gap, to prevent transmitters and receivers from interfering with each other.
Make the configuration this way:

  1. Connect the SYNC inputs of the transmitters respecting the polarities (FIG.9 and 10).

  2. Set each pair (RX and TX) to the same ID number. Different pairs must have different IDs.
    (TAB.1)** DIP 1, 2, 3 TX = RX| DIP 1, 2, 3 TX = RX
    ---|---
    On Symbols|
    1
    On Symbols|
    2
    On Symbols|
    3
    |
    4
    DIP 1, 2, 3 TX = RX| DIP 1, 2, 3 TX = RX
    ---|---
    |
    5
    |
    6
    |
    7
    |
    8**

  3. Using the DIP4 selector in the transmitters, select only one pair of photocells as MASTER. Set other pairs as SLAVE.
    **(TAB.2).


DIP 4 – TX MASTER / SLAVE
ON = MASTER
OFF = SLAVE

SIGNAL QUALITY TEST FUNCTION

This option is not available in IRIS BAT ADV version

This function allows you to visually understand the signal quality between the two photocells TX and RX. In this mode the receiver modulates the intensity of the LED according to the quality of the signal: the more the quality of the signal is good, the more the LED will be lit intensely; vice versa the more the quality of the signal is poor or absent, the more the led will be weak or off. When this function is active, the output of the receiver is always in alarm.

To activate this mode proceed as follows:

  1. Place the DIP4 selector in OFF of the receiver (TAB.3).
    DIP 4 – RX| NORMAL / TEST
    ---|---
    | ON = NORMAL FUNCTION
    | OFF = TEST MODE
  2. Perform the alignment operations.
  3. Once the alignment is finished, restore normal operation by moving the receiver DIP4 to the ON position.

MAINTENANCE

Before carrying out any cleaning, maintenance or replacement of parts, remove power to the automation. Every 12 months of activity, the following maintenance operations are mandatory:

  • Check and clean any dirt, insects and dust residues that have been placed inside.
  • Check the integrity of the cables and their connections, including clamping contact, and make the necessary replacements.
  • Perform a general and complete check of the screws and bolts.
  • Check the correct operation of the photocells.
  • Check battery status and replace if necessary

DAN GER

  • Read the instructions carefully before starting the installation and perform the interventions as specified by the manufacturer.
  • Installation, configuration, commissioning and maintenance must be carried out by qualified and experienced personnel and in full compliance with current regulations.
  • The equipment must be used exclusively for the purpose for which it was designed. Any other use is considered improper and therefore dangerous. The manufacturer cannot be held responsible for any damage caused by improper, erroneous and unreasonable use.
  • Also check the warnings in the installation and use manuals of the automation associated with the product. • Do not let children and animals play or stay near the automation.
  • Do not leave the device near heat sources, nor immerse it in liquids of any kind. • Keep new and used batteries out of the reach of children.
  • If the battery compartment does not close tightly, stop using the product and keep it out of the reach of children.
  • If you suspect that the batteries have been swallowed or inserted into other body orifices, seek medical attention immediately.
  • Use only batteries of the type indicated. Risk of explosion if the battery is replaced with a wrong type.
  • The data included in this manual have been compiled and verified with the utmost care, however the manufacturer can not assume any responsibility for any approximations, omissions or limitations due to technical or graphic requirements.
  • The technical specifications in this document may be subject to change without notice.

  WARNING

  • Symbol The receiver photocell bases its operation on the detection of the light emitted by the transmitter. Therefore, the adequacy of protection must also take into account the following phenomena during installation.
    • The infrared radiation emitted by the transmitter can be reflected by metal bodies and reach the detector indirectly.
    • If direct sunlight hits the detector or causes saturation (blinding) resulting in the opening of the safety contact.
  • The photocell receiver is equipped with an amplifier circuit of high-gain light signals. Therefore, in situations of exposure to extremely strong electromagnetic disturbances could distort its operation. This risk can be mitigated by using a shielded cable to connect the receiver photocell to the associated product.

 EC and UK Declaration of Conformity

The manufacturer, ALLMATIC s.r.l. declares that the IRIS BAT equipment type complies with the essential requirements set out in Directive 2014/30/EU. The declaration in its full format is available for consultation with the manufacturer.

WARRANTY

Symbol The manufacturer’s warranty is valid by law from the date printed on the product and is limited to the free repair or replacement of parts recognized by the manufacturer as defective due to lack of essential qualities in the materials or for errors in the production process. The warranty does not cover damage or defects due to external agents, lack of maintenance, overload, normal wear, installation error, or other causes not attributable to the manufacturer. Tampered products will not be covered by warranty. The manufacturer is not responsible for malfunctions or degradation of performance due to environmental interference, such as electromagnetic disturbances; therefore, the warranty expires in these situations.

 Product disposal

As for installation operations, the disassembly of this product must be carried out by qualified personnel. The symbol on the side indicates that the product should not be disposed of as unsorted waste, but should be sent to separate collection facilities for recovery and recycling. For disposal check the recycling or disposal systems provided by the territorial regulations in force for this category of product, or return the product to the seller.

WARNING

  •  This product consists of various types of materials: some parts of the product may contain pollutants or dangerous substances that, if dispersed, could cause harmful effects to the environment and health.
  • Local regulations may provide for heavy penalties in the event of incorrect disposal of this product.


Download this manual to your phone.

IRIS BAT IRIS BAT ADV
Adjustable photocells battery-powered

Allmatic S.r.l. Via dell’Artigiano, 132026 Borgo Valbelluna (BL) – ITALY
Tel (+39) 0437 75 11 75
www.allmatic.com info@allmatic.comSymbolLogo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

ALLMATIC User Manuals

Related Manuals