LENA LIGHTING UV-C Sterilon Clean Instruction Manual

June 9, 2024
LENA LIGHTING

UV-C Sterilon Clean
Instruction Manual INSTALLATION INSTRUCTIONLENA LIGHTING UV-C
Sterilon Clean - icon0

UV-C Sterilon Clean

LENA LIGHTING UV-C Sterilon Clean - fig 1A Flow contol
B Switch on-off
C Reset of UV-C fluorescent lamps
D Poprawna praca UV-CLENA LIGHTING UV-C Sterilon Clean - fig
3 4A CHANGING A UV-C TUBE Use protective gloves when replacing UV-C tubes
4B CHANGING A UV-C TUBELENA LIGHTING UV-C Sterilon Clean - fig
5 Wait 3 minutes after turning off the lamp before opening the door
4C CHANGING A UV-C TUBELENA LIGHTING UV-C Sterilon Clean - fig
6 4D CHANGING A UV-C TUBELENA LIGHTING UV-C
Sterilon Clean - fig 7 5A CHANGING FILTERS
Loosen the screws in the sequence shown in the pictureLENA LIGHTING UV-C
Sterilon Clean - fig 8

5B CHANGING FILTERS
Before installing the new filter, remove it from the packaging

5C CHANGING FILTERS

LENA LIGHTING UV-C Sterilon Clean - fig 10

D
GREEN
UP TO 8000H – OK
YELLOW
8000H – 9000H CLOSE TO END OF LIFESPAN

RED
OVER 9000H – REPLACE WITH NEW UV-C TUBES
RED BLINKING
FAULTY TUBES

The light source used in this luminaire should only be replaced by the manufacturer or his maintenance representative, or a similarly qualified person.
Do not cover the lighting fitting with an insulation mat or other materials. There should be free space (about 10 cm) provided around the installed luminaire.

**** IMPORTANT INSTRUCTIONS FOR SAFE USE

WARNING BEFORE USING LAMP FOR THE FIRST TIME, READ THE USER MANUAL AND FOLLOW THE INSTRUCTIONS.

UV-C Sterilon CLEAN flow luminaires use ultraviolet light, destroy the DNA or RNA of all microorganisms exposed to the light and remove viruses, bacteria and mould from the air. The shielded UVC light does not escape to the outside of the luminaire. Thanks to stimulated circulation, the air passes through the luminaire interior, where it is exposed to the light and disinfected, and then pushed outside. Luminaires can work in the presence of people.

Way of operation

  1. Place the luminaire in a disinfected room with the door directed towards the wall.
  2. Do not cover the luminaire, do not place any objects on the luminaire. In order not to disturb circulation, leave an empty space and do not put any objects within 1 metre of the luminaire fan.
  3. There may be people in the room. They can move freely and do not need protective clothing.
  4. Do not open the luminaire covers during its operation. Except for the flap to regulate the flow. Secure the luminaire against uncontrolled opening by other people, pay special attention to children.
  5. The smell emitted by the luminaire is a technical smell. It may last for approximately 140 hours when the device is used. This smell does not pose any threat to luminaire users.
  6. A small amount of visible blue light is reflected light which does not contain UV-C radiation and is safe for people.
  7. Before opening the door, turn othe luminaire and wait 3 minutes for the fans to stop.
  8. Do not open the door while the luminaire is connected to the electricity supply.
  9. After placing the luminaire in the desired place, release the locks on the wheels.
  10. Do not lean on the luminaire or tilt it.
  11. Lock the locks and do not leave the keys in them.

Maintenance and filter replacement
UV-C Sterilon CLEAN luminaires are equipped with pre-filters as standard. These filters should be replaced every three months or more often, depending on how dirty the filter is.
Operational safety
The UV-C light emitted by the lamp is highly harmful to humans and other living organisms, damages eyesight, skin and cell DNA. UV-C light degrades the DNA and RNA code in the cells of living organisms. In the event of damage to the body, UV-C rays may escape, which poses a threat to people and animals. If the fluorescent lamps break, ventilate the room for 30 minutes and remove the contaminated parts, preferably with gloves. Place them in a sealed plastic bag and take to a local waste disposal facility for recycling. Do not use a vacuum cleaner to remove damaged parts.

Assembly should be carried out by a qualified person
Dirtiness that settle down on the diffuser due to normal operation of the fitting shall be cleaned with a damp cloth. Do not use abrasive cleaners.
We would like to inform you that our product’s are marked in accordance with the European Directive 2002/96/CE and Polish Act o n used electric and electronic equipment with a sign of a crossed-out waste container:
This mark informs abort the fact that the device, after its application use, cannot be placed together with other types of household waste. The user is obliged to return it to the entities conducting a collection of used electric and electronic equipment. The collection points, including local collection points, shops and municipal entities create a proper system making it possible for the return of the equipment. Proper proceeding with used electric and electronic equipment contributes to the avoidance of damaging consequences for the health of the inhabitants and natural environment chick result form the presence of dangerous substances and improper storage and processing of such devices and equipment.

LENA LIGHTING S.A.
ul.Kornicka 52, 63-000 Sroda Wlkp.
POLAND
tel. +48 61 28 60 300
e-mail: office@lenalighting.pl
www.lenalighting.pl
Technical Data:
8x PL-L 36W, 220-240V, 50-60Hz
Cable 4m, 3×0,75mm
Protection class I
No protection against explosion.