ICM CONTROLS SC2010 N-L Non Programmable Electronic Thermostat Instruction Manual
- June 13, 2024
- ICM CONTROLS
Table of Contents
- SC2010 N-L Non Programmable Electronic Thermostat
- Parts Diagram
- Specifications
- Important Safety Information
- Package Contents/Tools Required
- To Remove Existing Thermostat
- To Install Thermostat
- Wiring Diagrams
- Installing and Changing Batteries
- Configuration Mode
- Configuration Mode Settings
- Operating Modes
- Lockout Feature
- SimpleSetTM Field Programming
- Troubleshooting
- ONE-YEAR LIMITED WARRANTY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
1 Heat/1 Cool
Manual Changeover
Battery or Hardwire
SC2010 N/L
Non-Programmable Electronic Thermostat
SC2010 N-L Non Programmable Electronic Thermostat
- Configurable
- Single Stage Heat/Cool Systems
- Single Stage Heat Pump Systems
- Large Display With Backlight (SC2010L)
- Selectable Fahrenheit or Celsius
- Compatible with Gas, Oil, or Electric
- SimpleSet™ Field Programming
- Relay Outputs (minimum voltage drop in thermostat)
- Ideally Suited for:
– Residential (New Construction/Replacement)
– Light Commercial
Installation, Operation & Application Guide
For more information on our complete range of American-made products
– plus wiring diagrams, troubleshooting tips and more, visit us at
www.icmcontrols.com
Parts Diagram
Specifications
Electrical rating:
- 24 VAC (18-30 VAC)
- 3.0 VDC (2 “AAA” batteries)
- 1 amp maximum per terminal
- 3 amp maximum total load
Temperature control range: | 45°F to 90°F (7°C to 32°C) |
---|---|
Accuracy | ± 1°F (± 0.5°C) |
System configurations: | 1-stage heat, 1-stage cool, heat pump, gas, oil, |
electric
Timing| Anti-short Cycle: 4 minutes
Backlight Operation (Note: with SC2010L only)
Terminations| G, B, O, Y, RH, RC, W, C
Important Safety Information
WARNING!: Always turn off power at the main power supply before installing, cleaning, or removing thermostat.
- This thermostat is for 24 VAC applications only; do not use on voltages over 30 VAC
- Do not short across terminals of gas valve or system control to test operation; this will damage your thermostat and void your warranty
- All wiring must conform to local and national electrical and building codes
- Do not use air conditioning when the outdoor temperature is below 50 degrees; this can damage your A/C system and cause personal injuries
- Use this thermostat only as described in this manual
Package Contents/Tools Required
Package includes: SC2010 N/L thermostat on base, thermostat cover, wiring
labels, screws and wall anchors, 2 “AAA” batteries, Installation, Operation
and Application Guide
Tools required for installation: Drill with 3/16” bit, hammer, screwdriver
To Remove Existing Thermostat
**** ELECTRICAL SHOCK HAZARD – Turn off power at the main service panel by removingthe fuse or switching the appropriate circuit breaker to the OFF position before removing the existing thermostat.
- Turn off power to the heating and cooling system by removing the fuse or switching the appropriate circuit breaker off.
- Remove cover of old thermostat. This should expose the wires.
- Label the existing wires with the enclosed wire labels before removing wires.
- After labeling wires, remove wires from wire terminals.
- Remove existing thermostat base from wall.
- Refer to the following section for instructions on how to install this thermostat.
To Install Thermostat
** ELECTRICAL SHOCK HAZARD – Turn off power at the main service panel by
removing the fuse or switching the appropriate circuit breaker to the OFF
position before removing the existing thermostat.
IMPORTANT: Thermostat installation must conform to local and national
building and electrical codes and ordinances.
Note:** Mount the thermostat about five feet above the floor. Do not mount
the thermostat on an outside wall, in direct sunlight, behind a door, or in an
area affected by a vent or duct.
-
Turn off power to the heating and cooling system by removing the fuse or switching the ppropriate circuit breaker off.
-
To remove cover, pull gently at the seam at the top.
-
Put thermostat base against the wall where you plan to mount it (Be sure wires will feed through the wire opening in the base of the thermostat).
-
Mark the placement of the mounting holes.
-
Set thermostat base and cover away from working area.
-
Using a 3/16” drill bit, drill holes in the places you have marked for mounting.
-
Use a hammer to tap supplied anchors in mounting holes.
-
Align thermostat base with mounting holes and feed the control wires through slit in thermal intrusion barrier and into wire opening.
-
Use supplied screws to mount thermostat base to wall.
-
Insert stripped, labeled wires in matching wire terminals.
CAUTION!: Be sure exposed portion of wires does not touch other wires. -
Gently tug wire to be sure of proper connection. Double check that each wire is connected to the proper terminal.
-
Place gas/elec jumper in correct position.
gas = gas/oil systems
elec = electric heat or heat pump systems -
Remove RC/RH jumper for 2-transformer systems.
-
Non-heat pump jumper must be in Non-HP unless the system is a heat pump.
-
Insert 2 “AAA” batteries into battery holder. Orient them in the proper direction.
-
Turn on power to the system at the main service panel.
-
Configure thermostat (see Configuration Mode Settings) to match the type of system you have.
-
Replace cover on thermostat by snapping it in place.
-
Test thermostat operation as described in “Testing the Thermostat”.
Wiring Diagrams
Heating only
Hardwired 4-Wire, Single Transformer
Hardwired 3-Wire, Single Transformer
Heating/Cooling
Hardwired 4 or 5-Wire, Single Transformer
Hardwired 5-Wire, Two Transformer (Both transformers must be in phase)
Heat Pump
Hardwired Cool or Heat Active Reversing Valve
Cooling only
Hardwired 4-Wire, Single Transformer
Installing and Changing Batteries
For Battery Thermostat Operation
If your LCD is blank, or displaying LO BAT, the batteries are not installed or
need to be changed. We suggest you change the batteries at least once a year,
or whenever the LO BAT warning displays.
Remove the cover, and install the two “AAA” alkaline batteries into the
battery compartment. Proper battery installation is important! Make sure the
positive ends of the batteries match the positive terminals in the battery
compartment. For Hardwired Thermostat Operation
Batteries are not required when a common wire is connected to the C terminal
of the SC2010 N/Lthermostat.
Configuration Mode
The configuration mode is used to set the SC2010 N/L to match your system.
To configure the SC2010 N/L, perform the following steps:
- Verify the SC2010 N/L is in the OFF mode. Slide the system switch to the center position until off mode displays.
- Remove the cover of the thermostat by gently pulling near one of the corners at the top of the thermostat.
- Press both the LEFT and RIGHT switches for 1 second while the SC2010 N/L is in OFF mode.
Press the up or down button to change settings within each screen. Press the RIGHT switch to advance to the next screen.
Note: Pressing the LEFT switch will return you to the previous screen.
To exit configuration mode, press both the LEFT and RIGHT switches for 1 second or slide the mode switch to heat or cool.
Configuration Mode Settings
The setup screens for Configuration Mode are as follows:
-
Temperature Scale (F or C) – Choose Fahrenheit or Celsius.
Press the up or down button to select.
Press the RIGHT switch to advance to the next screen. -
Temperature Differential (1°F to 5°F) (1°C to 3°C) – Set the number of degrees between your “setpoint” temperature and your “turn on” temperature.
Press the up or down button to set differential value.
Press the RIGHT switch to advance to the next screen. -
Heat Pump and Non-Heat Pump – Set to heat pump, or non-heat pump system. For heat pumps, there will be a compressor time delay for heating and cooling.
• 1 = Heat pump system
• 0 = Non-heat pump system
Press the up or down button to select.
Press the RIGHT switch to advance to the next screen. -
Lockout (0°F-8°F) (0°C-8°C) – Select the number of degrees set temperature can be changed during keypad lockout
Press the up or down button to select.
Press the RIGHT switch to advance to the next screen. -
Maximum Heat Setpoint (45°F to 90°F) (7°C to 32°C) Adjust to control the maximum heat set temperature allowed.
Press the up or down button to select.
Press the RIGHT switch to advance to the next screen. -
Minimum Cool Setpoint (45°F to 90°F) (7°C to 32°C) Adjust to control the minimum cool set temperature allowed.
Press the up or down button to select.
Press the RIGHT switch to advance to the next screen. -
Room Temperature Offset (+9°F to -9°F) (+5°C to -5°C) Adjust to calibrate displayed room temperature to match actual room temperature.
Press the up or down button to select.
Press the RIGHT switch to advance to the next screen. -
Maximum Cycles Allowed Per Hour (- -, 2-6) – – = as many as needed, 2-6 = maximum cycles/hour Press the up or down button to select.
Press the RIGHT switch to advance to the next screen. -
Back Light (0 or 1) (Note: For SC2010L only)
0 = Back light never on (best for long battery life)
1 = Back light on when button pressed
Press the up or down button to select.
To exit configuration mode, press both the LEFT and RIGHT switches for 2 seconds or slide the mode switch to heat or cool.
Operating Modes
OFF Mode
• In this mode, the thermostat will not turn on the heating or cooling
devices (manual fan can operate)
• OFF mode is also used to access the configuration screens
Cool Mode
• In this mode, the thermostat controls the cooling system
Heat Mode
• In this mode, the thermostat controls the heating system
Lockout Feature
The SC2010 N/L has a button lockout feature so the temperature adjustment is prohibited or limited. Select the appropriate lockout from Configuration Mode Settings (Step 4) of this guide. To activate the LOC feature:
- Simultaneously press the LEFT, RIGHT and UP buttons for 10 seconds.
- LOC will display and the lockout function will be enabled.
To deactivate the LOC feature, repeat steps 1 and 2 above.
SimpleSetTM Field Programming
This feature is used for transferring the configuration settings from the
master to the target thermostat. All thermostats for a job can be mounted and
powered up. Configure one thermostat. This will be the master. The master will
be used to copy the configuration to the rest of the thermostats.
Preparing the master to Send:
-
The master must be powered by 24 VAC or batteries.
-
Verify the master thermostat is in OFF mode. Slide system switch to center position.
-
Remove cover of the master thermostat by gently pulling near one of the corners at the top of the thermostat.
-
Press the up and down buttons and RIGHT switch simultaneously for 5 seconds.
-
The OUT screen displays indicating the master thermostat is ready to transfer data.
Note: Press the up and down buttons and RIGHT switch simultaneously for -
Connect the master to the target using the 3 wire connector. Attach one end to the Master’s FP pins and the other end to the Target’s FP pins.
Note: Target thermostat must be powered by 24 VAC or batteries for field programming to occur.
When the connection has been made correctly, the master thermostat will power
up and the target will count from 6 down to 1. It will then display LOC
confirming the data has been saved in memory.
When all target thermostats have been completed, reinstall the master
thermostat.
Press the up and down buttons and the RIGHT switch simultaneously for 5
seconds to exit from the data transfer mode and to return the master
thermostat to the OFF mode.
Troubleshooting
Symptom | Remedy |
---|---|
No display | Check for 24 VAC at thermostat; display is blank when 24 VAC is |
not present or if batteries are completely discharged
System fan does not come on properly| Verify wiring is correct, check
Gas/Electric jumper position (see Parts Diagram)
All thermostat buttons are inoperative| Verify 24 VAC is present; unit locks
out when 24 VAC is not present with no batteries installed
No response with first button press| First button press activates backlight
only when back light is configured “ON” (see Configuration Mode Setting 9)
Heat or Cool not working| RC/RH jumper must be installed on single transformer
systems For heat pumps, Non-HP jumper must be on HP pins
Thermostat turns on and off too frequently| Adjust temperature differential
(see Configuration Mode Setting 2)
Fan runs continuously| Slide FAN switch to auto to turn fan off
Room temperature is not correct| Calibrate thermostat (see Configuration Mode
Setting 7)
LOC displays when any button is pressed| Thermostat has the button lockout
function activated (see Lockout Feature and Configuration Mode Setting 4)
Heat or Cool not coming on| Verify wiring is correct, verify RC/RH jumper is
in place (for single transformer system)
on display| Replace batteries with two fresh “AAA” alkaline batteries
Problem not listed above| Press Reset button once*
ONE-YEAR LIMITED WARRANTY
The Seller warrants its products against defects in material or workmanship for a period of one (1) year from the date of manufacture. The liability of the Seller is limited, at its option, to repair, replace or issue a non-case credit for the purchase prices of the goods which are provided to be defective. The warranty and remedies set forth herein do not apply to any goods or parts thereof which have been subjected to misuse including any use or application in violation of the Seller’s instructions, neglect, tampering, improper storage, incorrect installation or servicing not performed by the Seller. In order to permit the Seller to properly administer the warranty, the Buyer shall: 1) Notify the Seller promptly of any claim, submitting date code information or any other pertinent data as requested by the Seller. 2) Permit the Seller to inspect and test the product claimed to be defective. Items claimed to be defective and are determined by Seller to be nondefective are subject to a $30.00 per hour inspection fee. This warranty constitutes the Seller’s sole liability hereunder and is in lieu of any other warranty expressed, implied or statutory. Unless otherwise stated in writing, Seller makes no warranty that the goods depicted or described herein are fit for any particular purpose.
Patent No. 424,953
7313 William Barry Blvd., North Syracuse, NY 13212
LIAF019-1
(Toll Free) 800-365-5525 (Phone)
315-233-5266 (Fax)
315-233-5276
www.icmcontrols.com