ICM CONTROLS ICM870 9A Color Height Length UPC User Manual

June 3, 2024
ICM CONTROLS

ICM CONTROLS ICM870 9A Color Height Length UPC

ICM-CONTROLS-ICM870-9A-Color-Height-Length-UPC-product-
image

FEATURES

  • Starting current reduction & self-learning algorithm
  • Built-in start capacitor
  • Over/under voltage monitoring
  • Over-current protection
  • Diagnostic indicators
  •  Sealed enclosure

SPECIFICATIONS

  • Inputs: L1 & L2
  • Nominal voltage: 120 VAC, 240 VAC
  • Over voltage limits: 120 VAC nominal = 140 VAC 240 VAC nominal = 250 VAC
  • Under voltage limits: 120 VAC nominal = 95 VAC 240 VAC nominal =195 VAC
  • Outputs: Compressor
  • Current: Maximum nominal = 9 A, 16A Absolute maximum = 22 FLA, 84 LRA
  • Over current limits: ICM870-9A = 11.25A, ICM870-16A = 20A
  • Operating temperature: -40°F to 131°F (-40°C to 55°C)
  • Storage temperature: -40°F to 149°F (-40°C to 65°C)
  • Humidity: 0-95% non-condensing
  • Enclosure: IP65/Type 4X
  • Dimensions: 7.63” x 3.19” x 2.13”

OVERVIEW

The ICM870 is intended for marine, recreational vehicle (RV), residential and commercial applications. The ICM870 integrates compressor or motor in-rush current over startup time, thus reducing peak current demand on a power supply source, such as generator or other.
The ICM870 will monitor system health including voltage, current, compressor startup and self integrity. Upon a fault condition, the
ICM870 will halt operation and initiate a 3 minute anti-short cycle routine while providing diagnostic fault information by means of an LED
indicator.

REPLACES

  • Dometic Smart Start: Models 340582 and 340583