Important safety instructions! Please read before connection!
DANGER! (Electrical shock due to high voltages in the device) The housing must not be removed! There are no parts to be maintained in the device. Inside the unit there are components which are under high electrical voltage.
Before each use, check the device for damage or the absence of components, protective devices or housing parts. If this is the case, the device must not be used!
Leave maintenance and repair work to a qualified service workshop or contact your dealer. In the case of a malfunction of the device, operation must also be stopped immediately until the device has been repaired by a specialist!
DANGER! (Electric shock due to short circuit)
Modifications to the power cord or plug are prohibited. If the power cord is
damaged, it must be replaced immediately with an original spare part from the
manufacturer. Failure to do so may result in fire or death due to electric
shock!
DANGER! (For babies and children)
Dispose of or store any packaging material properly! Packaging material must
be kept out of the reach of babies and children due to the risk of
suffocation.
Ensure that children never use the appliance unattended! In addition, make sure that children do not remove (small) parts from the device, as they could suffocate by swallowing parts!
Hint! (Fire hazard due to
overheating)
The maximum permissible ambient temperature of this device is -5 to +45°C.
Ensure that the unit is placed in a location with adequate ventilation, out of the reach of direct heat sources, open fire and flammable materials and liquids. A minimum distance of 1 m is required.
Do not tape or cover the ventilation slots of the unit.
DANGER! (Dealing with granules)
The granulate is a dangerous combustion product that can ignite spontaneously
when exposed to air or moisture and thus lead to fires and explosions. Keep it
away from heat, hot surfaces, sparks, open flames and other sources of
ignition. Do not smoke. Always protect from moisture. Avoid dust formation.
Always wear protective clothing, gloves and goggles. Always provide adequate
ventilation.
The material reaches very high temperatures in case of fire and therefore requires special Extinguishing measures. Suitable extinguishing agents are metal fire powder (fire class D) and dry sand. Unsuitable extinguishing media are water, foam and carbon dioxide. There is a risk of explosion!
Hint! (Operating conditions)
Due to its structural characteristics, the device is designed for indoor
operation (IP20). Never expose the device to rain, moisture or liquids, as
this can cause damage.
Vibrations, dust or sunlight can also lead to damage, avoid them!
The spark effect produces smoke, an odour nuisance and deposits on the floor due to precipitated particles. Therefore, always ensure adequate ventilation, especially in closed rooms.
Hint! (Power supply)
It is essential that you check that the device voltage matches your local
mains voltage. Itis highly recommended that you fuse your mains socket with a
residual current circuit breaker (FI).
If you do not use your device for a longer period of time or carry out maintenance work, disconnect the device from the mains in order to minimize danger. The same applies tostorm conditions such as thunderstorms, floods, etc.
Hint! (Error during data
transmission)
Never connect the DMX input or output to audio devices such as power
amplifiers or mixing consoles!
DMX cables enable trouble-free operation and the highest possible transmission reliability of signal data. Do not use microphone cables!
Hint! (Condensation)
To avoid condensation in the unit, the unit should adapt to the ambient
temperature before commissioning.
Hint! (Unwanted odours)
A new product can sometimes lead to unwanted odours. This reaction is normal
and
disappears after a few minutes.
Hint! (Matching granules)
Always disconnect the unit from the mains before filling! Do not fill in hot
liquids! Only use high-quality granulate recommended by your dealer. Other
granules may cause damage. Do not mix anyadditives, such as oil, gas,
perfumes, salts, etc., into the granulate.
Matching granules:
LIG0016966-000 – lightmaXX Powder VECTOR Spark Up!
Ideally, always fill the entire contents of a pack of granules into the filling opening of the device. If possible, store the partial quantities in the original packaging or in an airtight sealable container for later reuse. Store the granules in an airtight sealed container in a dry, well ventilated place with a temperature not exceeding 20° until reuse. Never store together with other substances with which a dangerous chemical reaction is possible.
The interior of the device must be cleaned of granulate residues and serviced at regular intervals.
Symbols on device and packaging:
- **** The lightning flash symbol warns the user of uninsulated voltages and the risk of electric shock.
- The exclamation mark symbol draws the user’s attention to important maintain and operating instructions in the manual.
- Only suitable for indoor use.
- This symbol defines the minimum distance of the object to be illuminated.
- Read the manual
Please read and follow the warnings and recommendations carefully to ensure
safe
and trouble-free use
Installation
Be sure to check the device for damage before use. Use the original packaging or a suitable transport or storage packaging to protect the product optimally from influences such as dust, moisture, etc. when not in use.
Always place the device on a stable surface. The device may only be operated in an upright position. Do not lay it on its side. The appliance has an automatic stop mechanism that prevents sparks from being emitted if the appliance is tilted by more than 45°.
Never point the outlet opening directly at people or open flames. Keep an appropriate safety distance of 1 meter from the audience and from heat- sensitive and highly flammable objects (e.g. insulation materials in ceilings, wooden and plastic surfaces, curtains).
Congratulations on your new lightmaXX Vector Spark UP!
Thank you for choosing a lightmaXX product. Through efficient development and economical production, lightmaXX enables high quality products at a fantastic price.
Please read the instruction manual carefully to learn about all the features of this product and keep it for future use.
Have fun with your new product!
Your lightmaXX Team
Guarantee:
The current general terms and guarantee conditions of the Music Store
professional GmbH apply. You can view it at:
www.musicstore.de
Scope of delivery:
Content | Quantity |
---|---|
Spark Machine | 1 |
Power Cord | 1 |
Manual | 1 |
Intended use
The product lightmaXX Vector Spark UP! creates a spark effect by heating a
special granulate. The device may only be operated for this purpose and in
accordance with the operating instructions. Other purposes, as well as
operation under other operating conditions, are expressly not intended and can
lead to damage to property or personal injury! No liability is accepted for
damage resulting from improper use.
It must be ensured that the device is operated exclusively by trained and competent users who are in full possession of their mental, physical and sensory abilities. The use of other persons is expressly only permitted at the request of a person responsible for their safety, who instructs or supervises the use
Set up:
All connections of the device should be made before switching on. Only use
high-quality cables that are as short as possible for the connections.
Configuration oft he DMX connector:
Resistance 120 ohm // ¼ w between pin 2 (DMX-) and pin 3 (DMX+) oft he last
fixture.
Operating mode DMX:
Connect the DMX input of your device to the DMX output of your DMX controller,
your DMX software or the DMX output of a device already in your DMX line.
Always use a DMX cable with a
110 Ohm resistor for this connection. Address the device according to your DMX
configuration. The following table shows the respective DMX modes of the
individual devices with the corresponding values and functions:
Channel Mode
Channel | Value | Function | Display |
---|---|---|---|
**1** | 000-010 |
011-220
230-239
240-255| Preheat function OFF Emergency STOP Cleaning modePreheat function ON|
E57 CLE
**2**| 000-015
016-063064-111112-
158159-207
208-255| Spark Effect OFF
Height 1 meter
Height 2 meter
Height 3 meter
Height 4 meter
Height 5 meter| OFF F1 F2 F3 F4F5
Operating mode Remote:
The device can be remote controlled using the remote control included in the
scope of delivery.
Button | Function |
---|---|
1 | Fountain height 1 |
2 | Fountain height 2 |
3 | Fountain height 3 |
4 | Fountain height 4 |
5 | Short press: Stop heatingLong press (3 sec.): disconnect Remote |
Control
6| Emergency Stop
7| Short press: Start heatingLong press (3 sec.): connect Remote Control
8| Clear Powder
Operation
Set up and fill in granulate:
Place the lightmaXX Vector Spark UP! on a flat and dry surface and fill the
machine with the granulate provided. To do this, remove the lid of the filling
opening and then fill in the contents of
a bag of granulate. It is best to use a funnel for this. Then close the
filling opening with the appropriate lid again.
Start:
Connect the device to the mains via the Powe Twist input using the power cable
supplied with the device.
Further devices can be supplied with power via the Power Twist Out mains output. Always connect the Power Twist output with the Power Twist input of the next device until all devices are connected. A total of up to 6 devices can be connected
Switch on:
Switch the unit on with the power switch. The unit will now heat up for 5
minutes while the red
status indicator “HEAT” lights up. The display to the right of the status
displays and operating buttons shows the rising temperature during the heating
phase. No sparks can yet be emitted during the heating phase.
As soon as the heating phase is complete, the green status display “READY” lights up and the unit is ready to emit sparks.
The unit can emit a fountain over a period of 30 seconds. After these 30 seconds the unit stops automatically. The ejection must be reactivated.
Status display:
Display | Function |
---|---|
READY | The unit is ready for spark discharge |
DMX | DMX mode activated |
FAULT | Error message (see Troubleshooting) |
HEAT | The unit heats up, no sparks |
Connections and controls:
No. | Designation | No. | Designation |
---|---|---|---|
1 | Outlet opening | 8 | Operating keys |
2 | Filling opening for the granulate with lid | 9 | On-/Off-Switch |
3 | Handle | 10 | Fuse |
4 | Fan | 11 | DMX Input (3-pole) |
5 | Removable cover for interior maintenance | 12 | DMX Output |
(3-pole)
6| Status displays| 13| Power Twist Input
**7| ** Display| **14**| Power Twist output for power supply
of further devices(max. 6 devices)
Specifications
Model | Vector Spark UP! |
---|---|
Power supply | AC 220-240V, 50Hz |
Power consumption | 650 Watt |
Fuse | 110V/10A, 220V/6A |
Permitted Ambient temperature range | -5 – +45 °C |
DMX Channels | 2 |
Connections | DMX-Input/Output (3- pole) Power Twist Input/ |
Discharge height | 1Ou-t5pumt eters |
Discharge time | 5 minutes |
Material Case | Aluminium |
Dimensions (L x W x H) | 185 x 185 x 252 mm |
Weight | 5,9 kg |
Troubleshooting
The following overview serves as an aid for quick troubleshooting. If you are unsure, contact the manufacturer, the dealer or the corresponding specialist personnel. Never open the device on your own!
Symptom | Troubleshooting |
---|---|
E01 Heating process failed | Check whether the heat dissipation plate |
is defective. Replace the heat dissipation plate or theheating plate.
E02 Heating not controlled| Replace heating plate
E03 Internal core temperature of the machine too high| Check the
fan. Stop the heating/operation and restart the appliance after 10 minutes
E04 Fan does not work| Check whether a foreign object has fallen
into the fan. Replace the fan.
E05 Temperature sensor has failed| Replace the temperature sensor
No function| Check the mains connection and the fuse
| Check the cable connections
No reaction in DMX mode| Check your DMX address setting
| If available, try an alternative DMX controller
No reaction in remote mode| Change the battery in your remote control
Ensure that the IR transmitter and receiver are at close and clear distances
from each other
If the specified corrections have not led to success, please contact our service staff. The contact details can be found at www.musicstore.de
Cleaning and maintenance:
Regular cleaning of the device from impurities and dust increases the durability of the product. Always disconnect the appliance from the power supply before cleaning! Never clean the appliance wet! Avoid dust formation. Unavoidable dust deposits must be regularly removed with spark-free tools and collected in a lockable container.
Optical lenses should be cleaned with a dry microfiber cloth, optimizing light output. Ventilation grilles and openings should always be kept free of dust and dirt. Electrical component suitable compressed air sprays are recommended for this application
Cleaning the lightmaXX Vector Spark UP! after use:
At the end of use, perform the integrated cleaning function by radio remote
control or DMX operation to clean the internal granulate residues.
Let the machine cool down first. Then turn the machine upside down and empty the granulate container completely. Finally, pick up the residue with non- sparking tools. You can store the residues in an airtight container for later reuse.
Storage of the granules:
Protect the granulate from moisture and ignition sources. Do not smoke. Avoid
dust formation.
Always wear protective clothing, gloves and goggles. If possible, store the
leftovers in their original packaging. Store the granules in an airtight
sealed container in a dry, well ventilated place with a temperature not
exceeding 20° until reuse. Never store together with other substances with
which a dangerous chemical reaction is possible.
Cleaning of the interior:
After 5 applications it is necessary to clean the interior in the area of the
toothed belt, fan and the electronic unit from granulate residues. To do this,
unscrew the cover of the housing and remove the residues. After cleaning,
remount the cover before reusing the instrument.
Environmental protection:
The company MUSIC STORE professional GmbH always strives to reduce the burden of packaging to a minimum. The use of environmentally friendly and recyclable materials is of fundamental importance to us. Please dispose of and recycle the packaging components after use properly.
Disposal of packaging:
Ensure that paper packaging, plastic materials, etc. are separately recycled.
Observe the corresponding disposal instructions on the packaging.
Disposal of batteries:
Batteries do not belong in the garbage! Please keep batteries in accordance
with the official collection points or disposal stations in accordance with
the specifications.
Disposal of your old
device:
Do not dispose of the device with household waste! This device is subject to
the WEEE\ Directive (Waste Electrical and Electronic Equipment) in its
currently valid version.
The device will be disposed of by an approved waste disposal company or your local waste disposal office. The regulations valid in your country must be observed
Hersteller: MUSIC STORE professional GmbH,
Istanbulstraße 22-26,
51103 Köln, Deutschland
If you have any questions or suggestions, please contact us:
Music Store professional GmbH
Istanbulstr. 22-26
51103 Köln
Geschäftsführer : Michael Sauer
WEEE-Reg.-Nr. DE 41617453
Tel: +49 221 8884-0
Fax: +49 221 8884-2500
info@musicstore.de
References
- Music Store Online-Shop für Musikinstrumente | MUSIC STORE professional
- Music Store Online-Shop für Musikinstrumente | MUSIC STORE professional
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>