MEAN WELL RSP-100-3.3 100W Single Output with PFC Function Owner’s Manual

June 13, 2024
MEAN WELL

MEAN WELL RSP-100-3.3 100W Single Output with PFC Function

MEAN WELL RSP-100-3.3 100W Single Output with PFC
Function

Features

Features

  • Universal AC input/ Full range
  • Built-in active PFC function
  • High efficiency up to 88%
  • Cooling by free air convection
  • Built-in remote ON-OFF control
  • Protections: Short circuit/ Overload/ Over voltage / Over temperature
  • LED indicator for power on
  • 3 years warranty

Applications

  • Factory control or automation apparatus
  • Test and measurement instrument
  • Laser related machine
  • Burn-in facility
  • RF application

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

Description

RSP-100 is a 1 OOW single output enclosed type AC/DC power supply. This series operates for 85~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by free air convection , working for the temperature up to 70°C.

Model Encoding/ Order Information

Model Encoding/ Order Information

SPECIFICATION

MODEL| RSP-100-3.3| RSP-100-5| RSP-100-7.5| RSP-100-12| RSP-100-13.5| RSP-100-15| RSP-100-24| RSP-100-27| RSP-100-48
---|---|---|---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 3.3V| 5V| 7.5V| 12V| 13.5V| 15V| 24V| 27V| 48V
RATED CURRENT| 20A| 20A| 13.5A| 8.5A| 7.5A| 6.7A| 4.2A| 3.8A| 2.1A
CURRENT RANGE| 0-20A| 0-20A| 0-13.5A| 0 – 8.5A| 0- 7.5A| 0- 6.7A| 0-4.2A| 0- 3.8A| 0-2.1A
RATED POWER| 66W| 100W| 101.25W| 102W| 101.25W| 100.5W| 100.8W| 102.6W| 100.8W
RIPPLE & NOISE (max.) Note.2| 100mVp-p| 100mVp-p| 100mVp-p| 100mVp-p| 100mVp-p| 100mVp-p| 150mVp-p| 150mVp-p| 250mVp-p
VOLTAGE ADJ. RANGE| 3.14-3.63V| 4.75 – 5.5V| 7.13-8.25V| 11.4-13.2V| 12.8 -14.9V| 14.3-16.5V| 22.8 – 26.4V| 25.7- 29.7V| 45.6 – 52.8V
VOLTAGE TOLERANCE Note.3| ±2.0%| ±2.0%| ±2.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.0%| ±1.0%| ±1.0%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 600ms, 30ms at full load
HOLD UP TIME (Typ.)| 16ms at full load
INPUT| VOLTAGE RANGE| 85- 264VAC        120- 370VDC
FREQUENCY RANGE| 47- 63Hz
POWER FACTOR (Typ.)| PF>0.93/230VAC           PF>0.98/115VAC at full load
EFFICIENCY (Typ.)| 83%| 86%| 87%| 86%| 86.5%| 87%| 87%| 87%| 88%
AC CURRENT (Typ.)| 1.1A/115VAC         0.55A/230VAC
INRUSH CURRENT (Typ.)| COLD START 30A/230VAC
LEAKAGE CURRENT| <2mA / 240VAC
PROTECTION| OVERLOAD| 105 – 135% rated output power
Protection type: Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE| 3.63 – 4.46V| 5.5- 6.75V| 8.25 – 10.13V| 13.2-16.2V| 14.85 -18.23V| 16.5- 20.25V| 26.4 – 32.4V| 29.7 – 36.45V| 52.8 – 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| ****

Shut down o/p voltage, recovers automatically after temperature goes down

FUNCTION| REMOTE CONTROL| CN1: < 0-0.8VDC POWER ON, 4-1OVDC POWER OFF
ENVIRONMENT| WORKING TEMP.| -30 – +70’C (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 – 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 – +85’C, 10 – 95% RH non-condensing
TEMP. COEFFICIENT| ±0 05%/’C (0 – 50’C)
VIBRATION| 10 – 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
OVER VOLTAGE CATEGORY| III; According to EN61558, EN50178,EN60664-1, EN62477-1; altitude upto2000 meters
SAFETY &
EMC
(Note4)| ****

SAFETY STANDARDS

| UL62368-1, TUV BS EN/EN62368-1, BS EN/EN61558-1, BS EN/EN61558-2-16, EAC TP TC 004, CCC GB4943.1,

BSMI CNS14336-1 approved, Design refertoAS/NZS 62368.1

WITHSTAND VOLTAGE| I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-0/P, 1/P-FG, O/P-FG:100M Ohms/ 500VDC I 25°C/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438, GB9254 Class B, GB17625.1
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020
OTHERS| MTBF| 2325.2K hrs min.   Telcordia SR-332 (Bellcore); 288.5K hrs min.       MIL-HDBK-217F (25°C)
DIMENSION| 179’99’30mm (L’W’H)
PACKING| 0.52Kg; 24pcs/14.5Kg/0.81CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25’C of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. The power supply is considered a component  which will be installed into a final equipment.  The final equipment must be re-confirmed  that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.’ (as available on http://www.meanwell.com)
  5. Strongly recommended that external output capacitance should not exceed 5000uF. (Only for: RSP-100-3.3/-5/-7.5)
  6. The ambient temperature derating of 3.5°C/1OOOm with fanless models and of 5°C/1OOOm with fan models for operating altitude higher * than 2000m(6500ft).
    Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

Mechanical Specification Mechanical Specification

Termina l Pin No. Assignment

Pin No.

|

Assignment

|

Pin No.

|

Assignment

---|---|---|---

1

| AC/L| 4,5| DC OUTPUT-V

2

| AC/N| 6,7| DC OUTPUT+V

3

| FG-½| |

Remote ON/OFF(CN 1 ): JST S2B-XH or equivalent(optional)

Pin No.

|

Assignment

|

Mating Housing

|

Terminal

---|---|---|---

1

| RC+| JSTXHP or equivalent| JST SXH-00 1T-P0.6 or equivalent

2

| RC-

Block Diagram

Derating Curve

Derating Curve

Output Derating VS Input Voltage

Output Derating VS Input Voltage

Downloaded fromArrow.com.