BEA MS31 Touchless-Activation Switch for Automatic Doors Instruction Manual

June 13, 2024
BEA

MS31 Touchless-Activation Switch for Automatic Doors

Product Information

Product Name: MS31 Touchless-activation switch for automatic doors

Product Model: MS31 Compatibility: JAMB,
SINGLE-GANG, DOUBLE-GANG, 6 ROUND Mounting Box Compatibility: JAMB,
SINGLE-GANG, DOUBLE-GANG, 6 ROUND, SURFACE-MOUNT, FLUSH-MOUNT
Weight:

Not specified Material: Not specified IP Rating

: Notspecified Certification: FCC: G9B-210161, IC: 4680A-210161
Technical Specifications: –

Technology :

  • Not specified – Radiated frequency:
  • Not specified – Radiated power density: Not specified
  • Supply voltage: to be operated from SELV-compatible power supplies only
  • Supply frequency: Not specified
  • Power consumption: Not specified
  • output relay contact rating (max. voltage): Not specified
  • Output relay contact rating (max. current): Not specified
  • Max. switching power: Not specified
  • Detection range: Not specified
  • Detection mode: Not specified
  • Output hold time: Not specified
  • Temperature range: Not specified Product Usage

Instructions

Precautions

  1. Shut off all power going to the header before attempting any wiring procedures.
  2. Maintain a clean and safe environment when working in public areas.
  3. Constantly be aware of pedestrian traffic around the door area.
  4. Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door.
  5. ESD (electrostatic discharge): Circuit boards are vulnerable to damage  by electrostatic discharge. Before handling any board, ensure you dissipate your body’s ESD charge.
  6. Always check the placement of all wiring before powering up to ensure that moving door parts will not catch any wires and cause damage to equipment. –
  7. Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation.
  8. DO NOT attempt any internal repair of the components. All repairs and/or component replacements must be performed by BEA, Inc.
  9. Unauthorized disassembly or repair may jeopardize personal safety, expose one to the risk of electrical shock, and adversely affect the safe and reliable performance of the product resulting in a voided warranty.
    Installation Tips
  • When wiring multiple devices together to create a system configuration, ensure that each device works independently to reduce troubleshooting if a discrepancy occurs. –
  • Prior to installing any equipment in either new or existing  circuits, verify correct line voltage and line stability. Always remember to shut off the power before performing circuit wiring.
  • Do not place the sensor in the door’s opening range where the sensor may see door movement.
  • Do not place moving objects in front of the sensor.
  • Do not use harsh cleaning agents to clean polycarbonate materials. BEA recommends using clean, lukewarm water and a soft, lint-free cloth to clean sensor windows and other  polycarbonate surfaces on our products.
  • Wiring: Wire the MAGIC SWITCH (MS31) to the door control according to the diagram shown in the user manual.

Touchless-activation switch for automatic doors

MOUNTING BOX COMPATIBILITY

| JAMB| SINGLE- GANG| DOUBLE- GANG| 6” ROUND
---|---|---|---|---


SURFACE- MOUNT

| ****

10BOXJAMBST

| ****

10BOX24SGSM

10ABOXSGSMS

| 10BOXDGSM

10BOX475SQSM*

10BOX45SQSM*

| ****

10BOX6RNDSM*


FLUSH- MOUNT

| ****

N/A

| ****

standard, single-gang electrical box**

| standard, double-gang electrical box**

10BOX45SQFM*

| ****

standard, single-gang electrical box**

TECHNICAL SPECIFICATIONS

Technology: microwave motion sensor
Radiated frequency: 24.125 GHz
Radiated power density: < 5 mW/cm2

Supply voltage:

to be operated from SELV-compatible power supplies only

| 12 – 24 VAC ±10%

12 – 24 VDC +30% / -10%

Supply frequency:| 50 – 60 Hz
Power consumption:| < 1.5W
Output

relay contact rating (max. voltage): relay contact rating (max. current): Max. switching power:

| relay with switch-over contact (voltage-free) 60 VDC / 125 VAC

1A (resistive)

30W DC / 60 VAC

Detection range:| 4 – 24” (adjustable)
Detection mode:| motion (bidirectional)
Output hold time:| 0.5 – 30 sec
Temperature range:| -4 – 131 °F (-20 – 55 °C)
Weight:| 0.34 lbs
Material:| PC, PE
IP rating:| IP54
Certification:| Electromagnetic compatibility (EMC) according to 2004/108/EC FCC: G9B-210161

IC: 4680A-210161

PRECAUTIONS

  • Shut off all power going to header before attempting any wiring procedures.
  • Maintain a clean and safe environment when working in public areas.
  • Constantly be aware of pedestrian traffic around the door area.
  • Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door.
  • ESD (electrostatic discharge): Circuit boards are vulnerable to damage by electrostatic discharge. Before handling any board, ensure you dissipate your body’s ESD charge.
  • Always check placement of all wiring before powering up to ensure that moving door parts will not catch any wires and cause damage to equipment.
  • Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation.
  • DO NOT attempt any internal repair of the components. All repairs and/or component replacements must be performed by BEA, Inc. Unauthorized disassembly or repair:
    •  May jeopardize personal safety and may expose one to the risk of electrical shock.
    • May adversely affect the safe and reliable performance of the product resulting in a voided warranty.

INSTALLATION TIPS

  • When wiring multiple devices together to create a system configuration, it is best to ensure that each device works independently. This will reduce troubleshooting if a discrepancy occurs.
  • Prior to installing any equipment in either new or existing circuits, verify correct line voltage and line stability. Always remember to shut off the power before performing circuit wiring.
  • Do not place the sensor in the door’s opening range, where the sensor may see door movement.
  • Do not place moving objects in front of the sensor.
  • Do not use harsh cleaning agents to clean polycarbonate materials. Harsh cleaning agents (e.g. ammonia) can cause damage to these materials. BEA recommends using clean, lukewarm water and a soft, lint-free cloth to clean sensor windows and other polycarbonate surfaces on our products.

WIRING

Wire the MAGIC SWITCH to the door control according to the diagram shown here.

NOTE : Use either green (N.O.) or yellow (N.C.) wire, not both. Refer to the door control manual to determine which must be used.

SET-UP

Four adjustments can be made to the sensor:

  1. Sensitivity potentiometer: adjust detection field from 4 to 24 inches (rotate clockwise to increase) factory default: 4 inches (fully CCW)
  2. Hold time potentiometer: adjust relay hold time from 0.5 to 30 seconds (rotate clockwise to increase) factory default: 0.5 sec (fully CCW)
  3. Output Mode switch: determines Toggle mode orTimer mode
    • Toggle (switch up) = detection activates the relay and the relay holds until a second detection deactivates the relay (recommended for switch applications)
    • Timer (switch down, factory default) = detection activates the relay for 0.5 to 30 seconds; relay will
  4. LED mode switch: determines if LED illuminates when in detection or when not indetection
    • switch up (factory default) = LED on when sensor is NOT in detection, LED off when in detection
    • switch down = LED on when sensor is is in detection, LED off when not in detection

INSTALLATION

1. Install an electrical box.If using a metal eletrical box, ensure that the sensor does not come in contact with the box to avoid shorting the unit.

2. Clip the MAGIC SWITCH cube to the face plate.
3. Secure the face plate to the electrical box with the provided screws.

Depending on the door installation, the weather-resistant foam gasket may be used.

TROUBLESHOOTING

Door does not open when swiping hand in front of sensor| | Bad or no power| | Check power supply. If LED switches on or flashes, power connections are okay.
---|---|---|---|---
Detection range too short| Adjust detection zone. Remove any metal plates in front of sensor.
Incorrect wiring/connection| Check wiring and relay connection.
Sensor stays in detection| Environmental conditions influencing sensor| Remove moving objects from around sensor.
Wrong output mode| Switch output mode to Timer.
Door remains open after detection/activation| Wrong output mode| Switch output mode to Timer.
Incorrect wiring/connection| Check wiring and relay connection.

FCC APPROVAL

This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions:

  • this device may not cause harmful interference, and
  • this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna
  • Increase the separation between the equipment and receiver
  • onnect the equipment into an outlet on a circuit different from that to which the receiver is connected
  • Consult the dealer or an experienced radion/TV technician for help

WARNING: CHANGES OR MODIFICATIONS TO THIS EQUIPMENT NOT EXPRESSLY APPROVED

BY BEA INC. MAY VOID THE FCC AUTHORIZATION TO BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS

BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or incorrect adjustments of the sensor/device; therefore, BEA, Inc. does not guarantee any use of the sensor/device outside of its intended purpose. BEA, Inc. strongly recommends that installation and service technicians be AAADM-certifi ed for pedestrian doors, IDA-certifi ed for doors/gates, and factory-trained for the type of door/gate system. Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor/device system performance is compliant with local, national, and international regulations, codes, and standards. Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer’s recommendations and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must be performed during each service call – examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107, UL294, UL325, and International Building Code). Verify that all appropriate industry signage, warning labels, and placards are in place. OPERATE THIS EQUIPMENT.

Tech Support & Customer Service: 1-800-523-2462
General Tech Questions: techservices-[email protected] | Tech Docs: www.BEAsensors.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BEA User Manuals

Related Manuals