A-IPOWER GXS6600RD Remote Dual Fuel Portable Generator Owner’s Manual

June 13, 2024
A-iPOWER

A-IPOWER GXS6600RD Remote Dual Fuel Portable Generator

Product Information

  • Product Name: Portable Generator
  • Model: GXS6600RD
  • Part Number: 32082-05673-00
  • Serial Number: [Serial Number]
  • Date Purchased: [Date Purchased]
  • Manufacturer: [Manufacturer]

Safety

The product manual contains important safety information that should be thoroughly read and understood before using the product. It includes general safety precautions to ensure the safe use of the generator.

General Safety Precautions

  • Always read and understand the manual before operating the generator.
  • Failure to follow the instructions may result in serious injury or death.
  • If any section of the manual is not understood, contact customer service for assistance.
  • The owner is responsible for proper maintenance and safe use of the generator.
  • Minimize exposure to chemicals emitted by the generator by avoiding breathing exhaust and wearing gloves or washing hands frequently when servicing the equipment.

Product Usage Instructions

Unpacking the Generator
To unpack the generator, follow these steps:

  1. Remove the packaging materials from the generator.
  2. Inspect the generator for any visible damage.

Parts Included
The generator package should include all necessary parts for assembly and operation. Refer to the manual for a complete list of included parts.

Assembly

Follow these steps to assemble the generator:

  1. Install the wheel kit by attaching it to the designated mounting points.
  2. Install the support leg to provide stability for the generator.
  3. Install the handle assembly for easy transportation.

Controls and Features

The generator is equipped with various controls and features. Refer to the manual for a detailed description of each control and feature.

Control Panel Features
The control panel of the generator includes specific features for operation. Refer to the manual for a detailed explanation of each feature.

Specifications

The manual provides detailed specifications of the generator, including power output, fuel capacity, dimensions, and weight. Refer to the manual for specific information.

PORTABLE GENERATOR
Owner’s Manual GXS6600RD

DO NOT RETURN TO STORE! CALL US FIRST 855-888-3598 FOR SUPPORT
Model: Serial: Date Purchased:
P/N: 32082-05673-00

Model# 2742009 REV00
SAVE THIS MANUAL FOR FUTURE REFERENCE

INTRODUCTION

Read This Manual Thoroughly
WARNING
Read and understand manual completely before using product. Failure to completely understand manual and product couldresult in death or serious injury.
If any section of this manual is not understood, contact customer Service at 855-888-3598, or www.a-ipower.com for starting, operating and servicing procedures. The owner is responsible for proper maintenance and safe use of the unit. SAVE THESE INSTRUCTIONS for future reference. This manual contains important instructions that must be followed during placement, operation and maintenance of the unit and its components. Always supply this manual to any individual that will use this unit.

The information in this manual is accurate based on products produced at the time of publication. The manufacturer reserves the right to make technical updates, corrections and product revisions at any time without notice.
WARNING
Operating, servicing, and maintaining this equipment can expose you to chemicals including engine exhaust, carbon monoxide, phthalates, and lead, which are known to the State of California to cause cancer and birth defects orother reproductive harm. To minimize exposure, avoid breathing exhaust, and wear gloves or wash your hands frequently when servicing this equipment. For more information go to www.P65warnings.ca.gov.

SAFETY
The words DANGER, WARNING, CAUTION, and NOTICE are used throughout this manual to highlight important information. Make sure that the meanings of this safety information is known to all who operate, perform maintenance on, or are nearthe generator.
This safety alert symbol appears with most safety statements. It means attention,become alert, your safety is involved! Please read and abide by the messagethat follows the safety alerts symbol.
The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard. The warnings in this manual and the tags and decals affixed to the unit are therefore not all-inclusive. If you use a procedure, work method or operating technique that the manufacturer does not specifically recommend you must satisfy yourself that it is safe for you and others. You must also make sure that the procedure work method or operating technique that you choose does not render the generator unsafe.

DEFINITIONS AND SYMBOLS

DANGER
Indicates a hazard which, if not avoided, will result in death or serious injury.

WARNING
Indicates a hazard which, if not avoided, could result in death or serious injury.

CAUTION
Indicates a hazard which, if not avoided, could result in minor or moderate injury.

NOTICE
Indicates information considered important, but not hazard-related (e.g.,messages relating to property damage).

Page 01

Asphyxiation Hazard
Explosion Hazard
Kickback

Electric Shock Hazard
Hot Surface. Do Not Touch the Surface. Burn Hazard
Operator’s Manual

Fire Hazard
Moving Parts Hazard

GENERAL SAFETY PRECAUTIONS

Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.
NEVER use inside a home or garage, Only use OUTSIDE and far away EVEN IF doors and windows are open. from windows, doors and vents.
Avoid other generator hazards. READ MANUAL BEFORE USE.
DANGER POISONOUS GAS HAZARD
Engine exhaust contains carbon monoxide, a poisonous gas that could kill you in minutes. You CANNOT smell it, see it, or taste it. Even if you do not smell exhaust fumes, you could still be exposed to carbon monoxide gas.
DANGER
The exhaust system must be properly maintained. Do not alter or modify the exhaust system as to render it unsafe or make it noncompliant with local codes and/or standards. Failure to do so will result in death or serious injury.
WARNING
Always, install battery operated carbon monoxide alarm indoors and installed according to the manufacturer’s instruction.

· Operate this product ONLY outside far away from windows, doors and vents to reduce the risk of carbon monoxide gas from accumulating and potentially being drawn towards occupied spaces. DO NOT run this product inside homes, garages, basements, crawl spaces, sheds, or other partially-enclosed spaces even if using fans or opening doors and windows for ventilation. Carbon monoxide can quickly build up in these spaces and can linger for hours, even after this product has shut off.
· ALWAYS place this product downwind and point the engine exhaust away from occupied spaces. If you start to feel sick, dizzy, or weak while using this product, shut it off and get to fresh air RIGHT AWAY. See a doctor. You may have carbon monoxide poisoning.
WARNING
If you start to feel sick, dizzy or weak while using the portable generator, you may have carbon monoxide poisoning. Get out side to fresh air immediately and call 911 for emergency medical attention. Very high levels of CO can rapidly cause victims to lose consciousness before they can rescue themselves. DO NOT attempt to shut off the generator before moving to fresh air. Entering an enclosed space where a generator is or has been running may put you at greater risk of CO poisoning.

Page 02

Page 03

WARNING
Starter cord kickback (rapid retraction) will pull hand and arm toward engine faster than you can let go which could cause broken bones, fractures, bruises, or sprains resulting in serious injury. · When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback. · NEVER start or stop engine with electrical devices plugged in and turned on.
Fuel Safety
DANGER

Propane/LPG (Liquid Petroleum Gas)
· Propane/LPG is highly flammable and explosive. · LPG is heavier than air and can settle in low places
while dissipating. · Propane/LPG has a distinctive odor added to help
detect potential leaks quickly. · In case of a petroleum gas fire, do not attempt to
extinguish the flame if the fuel supply valve is in the ON position. Introducing an extinguisher to a generator with an open fuel supply valve could create an explosion hazard. · When exchanging propane/ LPG cylinders, be sure the cylinder valve is of the same type. · Always keep the propane/LPG cylinder in an upright position. · Propane/LPG will burn skin if it comes in contact with it. Keep it away from skin at all times.

WHEN ADDING OR DRAINING GASOLINE

Gasoline, gasoline vapor and propane/LPG are highly flammable and explosive.Fire or explosion can cause severe burns or death.
DANGER
Do not overfill tank. Allow space for fuel expansion. If fuel spills wait until it evaporates before starting engine. Failure to do so will result in death and serious injury.
Gasoline and gasoline vapors · Gasoline is a liquid and can cause a fire or
explosion if ignited. Gasoline vapors can ignite as well. · Gasoline is a skin irritant and needs to be cleaned up immediately if spilled on skin or clothes. · Gasoline has a distinctive odor; this will help detect potential leaks quickly. · In case of a petroleum gas fire, do not attempt to extinguish the flame if the fuel supply valve is in the ON position. Introducing an extinguisher to a generator with an open fuel supply valve could create an explosion hazard. · Gasoline expands or contracts with ambient temperatures. Never fill the gasoline tank to full capacity, as gasoline needs room to expand if temperatures rise.

· Turn generator engine off and let it cool at least 2 minutes before removing gasoline cap. Loosen cap slowly to relieve pressure in gasoline tank.
· Only fill or drain gasoline tank outdoors in a well-ventilated area.
· DO NOT overfill gasoline tank. Allow space for fuel expansion.
· If gasoline spills, wipe spilled gasoline from the unit or wait until it evaporates before starting engine.
· Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.
· Check fuel lines, tank, cap, and fittings frequently for cracks or leaks. Replace if necessary.
· DO NOT light a cigarette or smoke. · DO NOT pump gasoline directly into the generator
at the gas station. Use an approved container to transfer the gasoline to the generator.
WHEN STARTING GENERATOR
· Ensure spark plug, exhaust system, gasoline cap, fuel lines, propane/LPG regulator and air filter are in place.
· Wipe spilled gasoline or wait until it evaporates before starting engine.
· Make certain that the generator is operating firmly on level ground.
· If you smell gasoline or propane, turn off all fuel supplies. Make certain, there is no fuel leak before operating the generator.

Page 04

DANGER
Gasoline, gasoline vapor and propane/LPG are highly flammable and explosive. Never use a gasoline container, gasoline tank, propane/LPG connector hose, propane/LPG cylinder or any other fuel item that is broken, cut, torn or damaged. Failure to do so will result in death and serious injury.
WHEN OPERATING THE GENERATOR · DO NOT operate the generator inside any building,
carport, porch, mobile equipment, marine applications, or enclosure. · DO NOT tip the generator at angle which causes fuel to spill. · DO NOT move the generator when is running.
DANGER
Gasoline, gasoline vapor and propane/LPG are highly flammable and explosive. Fire or explosion can cause severe burns or death. Do not refill the gasoline tank or replace the propane/LPG tank when the generator is operating.
WHEN TRANSPORTING, MOVING OR REPAIRING EQUIPMENT · Transport/move/repair with fuel tank EMPTY or
with fuel shutoff valve in OFF position. On dual fuel models, be sure the propane tank is disconnected and securely away from the generator. · DO NOT tip generator at angle which causes fuel to spill. · Disconnect spark plug wire.
WHEN STORING FUEL OR GENERATOR WITH FUEL IN TANK · Store away from furnaces, stoves, water heaters,
clothes dryers, or other appliances that have pilot light or other ignition source because they could ignite fuel vapors.

· Store Fuel in a container approved for gasoline. · Store any containers containing gasoline or
propane/LPG outdoor in a well-ventilated area, away from any combustibles or source of ignition.
DANGER
Generator voltage could cause electrical shock or burn will result in death or serious injury.
DANGER
Never use generator in wet or damp locations. Never expose generator to rain, snow, water spray while in use. Protect generator from all hazardous weather conditions. Moisture, or ice can cause a short circuit or other malfunction in the electric circuit. Water contact with a power source if not avoided, will result in death or serious injury.
DANGER
Contact with terminals, bare wires and electrical connections when generator is running will result in death or serious injury.
DANGER
Fire and electrocution hazard. Do not connect to a building’s electrical system unless the generator and transfer switch have been properly installed and the electrical output has been verified by a qualified electrician. The connection must isolate the generator power from utility power and must comply with all applicable laws and electrical codes. · Use a ground fault circuit interrupter (GFCI) in any
damp or highly conductive area, such as metal decking or steel work. · DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged. · DO NOT allow unqualified persons or children to operate or service generator.

Page 05

WARNING
Exhaust heat/gases could ignite combustibles, structures or damage fuel tank causing a fire, resulting in death or serious injury. Contact with muffler area could cause burns resulting in serious injury.
WARNING
When operating machine, do not touch hot surfaces. Keep machine away from combustibles during use. Hot surfaces could result in severe burns or fire. · Allow equipment to cool before touching. · Replacement parts must be the same and installed in the same position as the original parts. · It is a violation of California Public Resource Code, Section 4442, to use or operate the engine on any forest-covered, brush-covered, or grass-covered land unless the exhaust system is equipped with a spark arrester, as defined in Section 4442, maintained in effective working order. Other states or federal jurisdictions may have similar laws. Contact the original equipment manufacturer, retailer, or dealer to obtain a spark arrester designed for the exhaust system installed on this engine.
WARNING
Unintentional sparking could cause fire or electric shock resulting in death or serious injury.
WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR · Disconnect the spark plug wire from the spark plug
and place the wire where it cannot contact spark plug.
WHEN TESTING FOR ENGINE SPARK · Use approved spark plug tester. · DO NOT check for spark with spark plug removed.

WARNING
Starter and other rotating parts could entangle hands, hair, clothing, or accessories. Keep away from rotating parts, failure to do so could result in death or serious injury.
· DO NOT wear loose clothing, jewelry or anything that could be caught in the starter or other rotating parts.
CAUTION
Excessively high operating speeds could result in minor injury. Excessively low operating speeds impose a heavy load.
· DO NOT tamper with governor spring, links or other parts to increase engine speed. Generator supplies correct rated frequency and voltage when running at governed speed.
· DO NOT modify generator in any way.
NOTICE
Exceeding generators wattage/amperage capacity could damage generator and/or electrical devices connected to it. · DO NOT exceed the generator’s wattage amperage
capacity. · Start generator and let engine stabilize before
connecting electrical loads. · Connect electrical loads in OFF position, then turn
ON for operation. · Turn electrical loads OFF and disconnect from
generator before stopping generator.
NOTICE
Improper treatment of generator could damage it and shorten its life. · Use generator only for intended uses. · If you have questions about intended use, ask
dealer or contact local service center. · Operate generator only on level surfaces. · DO NOT expose generator to excessive moisture,
dust, dirt, or corrosive vapors. · DO NOT insert any objects through cooling slots. · If connected devices overheat, turn them off and
disconnect them from generator.

Page 06

· Shut off generator if: -Electrical output is lost. -Equipment sparks, smokes, or emits flames. -Unit vibrates excessively.
WARNING
Medical and Life Support Uses. · In case of emergency, call 911 immediately. · NEVER use this product to power life support
devices or life support appliances. · NEVER use this product to power medical devices
or medical appliances. · Inform your electricity provider immediately if you
or anyone in your household depends on electrical equipment to live. · Inform your electrical provider immediately if a loss of power would cause you or anyone in your household to experience a medical emergency.
Page 07

UNPACKING THE GENERATOR

· Open carton completly. Remove and verify carton content prior to assembly. Your generator ships with following items.
· Call our customer service at 855-888-3598 with the unit model and serial number for any missing item.
· Record model, serial number, and date of purchase on front cover of this munal for your own record.

Parts Included Your gasoline powered generator ships with the
following parts:

NO. Item Description

Qty

1 Wheels

2

2 Axle Pin

2

3 Flat Washer

2

4 Cotter Pin

2

5 Wheel cap

2

6 Flange Lock Nut M8

4

7 Support Leg with Vibraion Mounts

2

8 Flange Bolt M8*16

4

9 Spark Plug Wrench

1

10 Oil Bottle (0.7L)

1

11 Owner’s Manual

1

12 Quick Start Guide

1

13 Flexible Screw-on Funnel

1

14 Double Open wrench (8mm-10mm) 1 15 Double Open wrench (13mm-15mm) 1

16 30 AMP RV Adapter

1

17 Propane/LPG Hose with Regulator

1

18 Remote Control Fob

1

19 12V DC Battery Charging Cable

1

43 1 2 5
9 6
8 7

10

11

12

13

14

15

16

18

19

17

ASSEMBLY

Your generator requires some assembly prior to usage.
CAUTION
Assembly the generator will require lifting the unit. Always have assistance when lifting the generaotor.

assembled according to the instructions. Failure to completely understand manual and product could result in death or serius injury.
Call our customer service at 855-888-3598 for any assembly issues or concerns. Please have model and serial number available.

WARNING
Do not plug in or turn on the generator until it is fully Page 08

Install the Wheel Kit NOTE: The wheels are not intended for over-the-road use. 1 – place generator on a flat surface. 2 – Tip the generator on a piece of cardboard or
other soft material to protect the frame paint and prevent the generator from sliding. 3 – Slide axle pin (B) through the wheel (C), flat washer (E) and generator frame axles hole (D). 4 – Secure everything with cotter pin (F), then assemble Cap(A) to Wheel(C). Repeat on opposite side.
FE DC
B
A
Install the Support Leg 5 – Insert bolts (G) throught the support leg (H) and
holes on the generator frame as shown. 6 – Tighten bolts (G) and nuts (I) to the frame.

A

B

NOTICE
The generator is equipped with a battery charging feauture. Once the engine is running,a small charge will slowly recharge the battery. If you do not plan to use the generator for a long period of time,we recommend to DISCONNECT the battery plugs A and B to protect the battery from losing charge,You may also to use a battery float charger (not included) to maintain battery charge.
IMPORTANT: Before operating the generator the shock-absorbing seat (K) must be adjusted for clearance. Loosen the lock nut (L) and adjust the shock absorbing seat (K) so there is about 3-4mm gap between the top of the seat and the bottpm of the alternator bracket (M). Re-tighten the lock nut after adjustment.

I M K L

H

G

NOTE: Handle already is assembled on the unit.

Battery Cable Connection

M

A quick connect battery plug is pre-installed on the

battery.Cut the cable tie securing the plugs and push

L

two halves A and B firmly to connect them.

3-4mm K

Page 09

Removal of Shipping Support Brackets
Before you can run your new generator, follow these simple instructions: The following items must be removed before running your new generator. In order to protect your generator these items have been added to ensure safe delivery of your new generator.
NOTE:
Total of 2 red support brackets. Remove red support bracket before use! It is a packing material, will damage engine without removing it.
CAUTION
Failure to remove the support brackets, can result in damage to your generator, possible personal injury and avoid your warranty.

Refer to the following instructions and pictures to remove the attached engine support brackets (red)(D) under the engine. 1. Before filling the engine oil, tip the generator back onto its recoil frame end as indicated in this picture. Place the generator on the flattened cardboard box or other protective surface. 2. Remove the bolt (E) with double open wrench (8mm-10mm) (B). 3. Remove the bolt (F) and nut (C) with double open wrench (13mm-15mm) (A) and double open wrench (8mm-10mm) (B). 4. You may discard these brackets, as it is no longer required for normal operation of your generator.
Your generator is now ready for use. Refer to your owner’s manual for proper oil fill and startup Instructions.

A

B

C

C

DE F

DE F

Page 10

CONTROLS AND FEATURES

12 3

4

5

6 7 89

10 11 18 19

12 13

14

15 16

17

1 – Frame 2 – Recoil Starter 3 – Fuel Source Switch 4 – Control Panel 5 – Remote Holder 6 – Fuel Tank 7 – Fuel Cap 8 – Fuel Gauge 9 – Spark Plug 10 – Air Filter

11 – Engine 12 – Battery 13 – Support Leg 14 – Alternator Cover 15 – Muffler/Spark Arrester 16 – Carbon Canister 17 – Wheel 18- LPG Hose with Regulator 19- Hose Holder
Page 11

CONTROL PANEL FEATURES

1

2

3

4

55

6

7

5

8

12V

15 14 13 12 11

10

95

16

17

1. Push-Button START/STOP: Push once to automatically start the engine. Push again to stop the engine.
2. Data Center: Push the SELECT button to display the voltage (V), frequency (Hz) and total run time(Hour).
3. Remote Set Button: To pair the new remote control fob.
4. 5V DC USB Outlets: Supply 3.6A USB-A type and 3.0A USB-C type for different applications.
5. Circuit Breaker(AC): Protects the generator against electrical overloads.
6. 120/240V AC, 30A Twist Lock, Single Phase,60Hz Outlet (NEMA L14-30R): Supply either 120 Volt or 240 Volt output up to 30 amps.
7. 120V AC, 20A Duplex, Single Phase, 60Hz Outlets (5-20R): Each outlet is capable of carrying a maximum of 20 amps on a single outlet or a ombination of both outlets.
8. 120V AC, 30A Twist Lock outlet, single phase, 60Hz Outlet (NEMA L5-30R): This receptacle can provide120 volt output up to 30 amps.
9. Grounding Terminal: To ground the generator.
10. Voltage Selector Switch: To select 120 Volt or 240 Volt. Turn generator off before switching voltages.

11. 12V DC, Outlet (Automotive): Provides 12 volt DC power up to 8.3 amps.
12. Circuit Breaker(DC): Protects the generator against electrical overloads.
13. Low Oil Indicator: The Light will be illuminated when the engine oil level is low. Add oil.
14. CO (Carbon Monoxide) WATCH-GUARD Indicator Light (Red for Shut off and Yellow for Service): The CO(Carbon Monoxide) WATCH-GUARD monitors for the accumulation of poisonous CO gas around the generator produced by engine exhaust when the generator is running. If the CO WATCH-GUARD detects increasing levels of CO gas, it automatically shuts off the engine. See CO WATCH-GUARD section for more information.
15. Battery Switch: Restore the battery power to the control module. you must turn the switch to ON position before start the generator.
16. Propane/LPG inlet: Used to connect Propane/LPG hose to generator.
17. Fuel Source Switch: Used to select gasoline or propane/LPG operation.Engine switch is ON when the switch is on GAS or LPG positions.

NOTE: Total power drawn from all outlets must not exceed the nameplate rating. Page 12

SPECIFICATIONS

Model Starting Watts (Gas) Running Watts (Gas) Starting Watts (Propane/LPG) Running Watts (Propane/LPG) Rated AC Voltage Rated DC Voltage Rated Frequency Phase Grounding System (AC) Engine Type Engine Displacement Starting System Low Oil Shutdown Oil Type Oil Capacity Spark Plug OEM Type Spark Plug Replacement Type Spark Plug Gap Valve Intake Clearance Valve Exhaust Clearance Voltage Regulation System Alternator Excitement System Total Harmonic Distortion (THD) Fuel Tank Capacity Fuel Type Maximun Ambient Temperature Battery Spec Certifications

GXS6600RD 2742009 6600W 5300W 5900W 4800W 120/240V 5/12V 60HZ Single
Neutral Floating Single Cylinder, 4-Stroke OHV Air Cooled
274cc Recoil-Electric-Remote
Yes 10W-30 23.7 fl.oz (700ml) F6RTC NGK BPR7ES or Champion RN9YC 0.028~0.031inch (0.7~0.8mm) 0.004~0.006inch (0.1~0.15mm) 0.006~0.008inch (0.15~0.2mm)
AVR Brushed 23% 6.3Gal (24.00L) Gasoline-Propane/LPG 104°F (40°C) 12V,7Ah EPA- CARB Compliant

NOTICE

This product is designed and rated for continuous operation at ambient temperatures up to 104°F(40°C). If needed, this product can be operated at temperatures ranging from 5°F(-15°C) – 122°F(50°C) for short periods. If the product is exposed to temperatures outside of this range during storage, it should be brought back within this range before operation. This product must always be operated outdoors in awell-ventilated area and far away from doors, windows, and other vents. Maximum wattage and current are subject to and limited by such factors as fuel BTU content, ambient temperature, altitude, engine conditions, etc. Maximum power decreases about 3.5% for each 1,000 feet above sea level, and will also decrease about 1% for each 10°F(6°C) above 60°F( 16°C) ambient temperature.

Page 13

CO WATCH-GUARD
Carbon Monoxide (CO) Detection and Auto Shutoff System
Your Generator is equipped with Carbon Monoxide (CO) WATCH-GUARD detect system for your protection and safety. This detecting and shutoff system monitors for the accumulation of poisonous CO gas around the generator produced by engine exhaust when the generator is running. If the CO sensor detects increasing levels of CO gas, it automatically shuts off the engine. Generators are intended to be used outdoors and far away from occupied buildings, windows, doors and exhaust pointed away from them.

However, if the generator misused and operated in a location that results in the accumulation of CO inside an enclosed or partially enclosed space, CO WATCH- GUARD automatically shuts off the engine and notifies the user of what has happened and directs the user to read the instruction of CO WATCH-GUARD Action Label for steps to take.
CO WATCH-GUARD ACTION LABEL · ÉTIQUETTE D’ACTION · ETIQUETA DE FUNCIONAMIENTO

AUTOMATIC SHUTOFF – YOU MUST:
· MOVE GENERATOR TO AN OPEN, OUTDOOR AREA. · POINT EXHAUST AWAY. · DON’T RUN GENERATOR IN ENCLOSED AREAA (E.G. NOT IN HOUSE OR GARAGE).
ARRÊT AUTOMATIQUE – VOUS DEVEZ:
· DÉPLACER LA GÉNÉRATRICE DANS UN ESPACE EXTÉRIEUR OUVERT. · DIRIGER L’ÉCHAPPEMENT LOIN DE VOUS. · NE PAS FAIRE FONCTIONNER LA GÉNÉRATRICE DANS DES ENDROITS FERMÉS (COMME DANS LA MAISON OU LE GARAGE).
APAGADO AUTOMÁTICO – USTED DEBE:
· MOVER EL GENERADOR A UN ÁREA ABIERTA, EN EXTERIORES. · ORIENTAR EL TUBO DE ESCAPE HACIA AFUERA. · NO ACTIVAR EL GENERADOR EN ÁREAS CERRADAS (P.EJ.: EN UNA CASA O GARAJE).

· MOVE TO FRESH AIR. · GET MEDICAL HELP IF SICK, DIZZY OR WEAK.
· VOUS RETIRER À L’AIR FRAIS. · CONSULTER UN MÉDECIN SI VOUS ÊTES MALADE, ÉTOURDI OU FAIBLE.
· MOVER AL AIRE LIBRE. · OBTENER ATENCIÓN MÉDICA SI SE SIENTE ENFERMO, MAREADO O DÉBIL.
WARNING: / ADVERTISSEMENT: / ADVERTENCIA: TAMPERING WITH CO WATCH-GUARD COULD RESULT IN HAZARDOUS CONDITION. / L’ALTÉRATION DE WATCH-GUARD CO PEUT ENTRAîNER DES CONDITIONS DANGEREUSES. / HACER ALTERACIONES CON WATCH-GUARD CO PODRíA OCASIONAR CONDICIONES PELIGROSAS.

NOTIFICATIONS: BLINKING RED AND YELLOW LIHGT
There is a CO indicator light on the control panel with two possibilities:
1-Blinking Red Lightprovides notification that the generator was shutoff due to an accumulating CO level around the generator. The red light will blink for at least five minutes after a CO shut off. Automatic shutoff is an indication generator was improperly located. Move the generator to an open, outdoor area far from occupied spaces with exhaust pointed away. Once relocated to a safe area, the generator can be restarted. The red light will stop blinking automatically after 2-5 seconds upon engine re-start. If you start to feel sick, dizzy, weak, or your homes carbon monoxide alarm sounds while using the generator, get to fresh air right away. Call emergency services. You may have carbon monoxide poisoning.

2-Blinking Yellow Light provides notification that a CO WATCH-GUARD fault has occurred and no longer provides protection. The generator is shutoff automatically and the yellow light will blink for at least five minutes after shutoff. Call A-iPower Customer Service 855-888-3598 for repair. Do not use the generator until the sensor is working properly. The CO WATCH-GUARD must only be serviced by qualified technician to restore it to original settings.
Page 14

WARNING
DO NOT modify or tamper with the Carbon Monoxide Detecting System (CO WATCH- GUARD). Not following these instructions could result in death or serious injury due to Carbon Monoxide detecting system malfunction. CO WATCH-GUARD will detect the accumulation of carbon monoxide from other fuel burning sources such as engine powered tools used in the area of operation. If another generator is used and the exhaust is pointed at a CO WATCH-GUARD equipped generator, the CO WATCH-GUARD may initiate a shutoff due to rising carbon monoxide levels. This is not a fault. Hazardous carbon monoxide has been detected. You must take action to move and direct the equipment to better dissipate carbon monoxide far away from people or buildings. CO WATCH-GUARD only monitors when the generator is running. CO WATCH-GUARD DOES NOT replace carbon monoxide alarms. Tempering with the CO WATCH-GUARD will void your warranty.
WARNING
Tampering with CO WATCH-GUARD could result in a hazardous condition. Removing the CO WATCH-GUARD module will not allow the generator to start.
Page 15

Add Engine Oil
We recommend using SAE 10W-30 APISJ oil for best performance. Other high- quality detergent oils (APISJ or higher) are acceptable. Do not use special additives. Ambient temperature determines the proper oil viscosity for the engine. Use the chart to select the proper oil for the outdoor temperature range expected.

NOTICE
Do not attempt to crank or start the engine before it has been properly filled with the recommended type and amount of oil. Damage due to operation with no oil will void your warranty.
Recommended Engine Oil Type
10W-30

5W-30

10W-40

5W-30 Full Synthetic

¢’ -20

0

20

40

60

80 100 120

¢$ -28.9 -17.8 -6.7 4.4 15.6 26.7 37.8 48.9

Ambient temperature

1. Place generator on a flat, level surface. 2. Clean area around oil fill and remove yellow oil fill
cap/dipstick (A). 3. Wipe dipstick clean. 4. Using oil funnel, slowly pour contents of provided
oil bottle into oil filler neck (B) to the “H” mark on dipstick. Be careful do not overfill. Overfilling with oil could cause the engine to not start or hard starting. 5. Replace oil fill cap/dipstick (A) and fully tighten. 6. Oil level should be checked prior to each use or at least every 8 hours of operation. Keep oil level maintained.

NOTICE
We consider the first 5 hours of run time to be the break-in period for the unit. During the break in period stay at or below 50% of the running watt rating and vary the load occasionally to allow stator windings to heat and cool. Adjusting the load will also cause engine speed to vary and help seat piston rings.
Low Oil Shutdown The unit is equipped with a low oil shutdown. If the oil level becomes lower than required, the sensor will activate a warning device or stop the engine. If generator shuts off and the oil level is within specifications, check to see if generator is sitting at an angle that forces oil to shift. Place on an even surface to correct this. If engine fails to start, the oil level may not be sufficient to deactivate low oil level switch. Make sure the sump is completely full of oil.
Add Fuel:Gasoline
DANGER
Gasoline and gasoline vapor are highly flammable and explosive.Fire or explosion can cause severe burns or death.
DANGER

Do not overfill tank. Allow space for fuel expansion. If fuel spills wait until it evaporates before starting engine. Failure to do so will result in death and serious injury.

A

H

L

B

The engine is equipped with a low oil shut-off and will stop when the oil level in the crankcase falls below the threshold level.

Gasoline must meet these requirements: · Clean, fresh, unleaded gasoline. · Use regular UNLEADED gasoline with the generator
engine with a minimum 87 octane / 87 AKI (91RON). Do not use E85 or E15. For high altitude use, see “Operation at High Altitude”. · DO NOT mix oil in gasoline. · DO NOT modify engine to run on alternate fuels
Page 16

A

B

1. Remove the gasoline cap (A) slowly. 2. Slowly add unleaded gasoline to gasoline tank. Be
careful not to fill above the red fuel level indicator (B). This allows adequate space for fuel expansion. 3. Install gasoline cap and let any spilled fuel evaporate before starting engine or wipe the spilled gasoline.
WHEN ADDING GASOLINE
· Only fill the gasoline tank outdoors in a well-ventilated area.
· DO NOT overfill gasoline tank. Allow space for fuel expansion.
· If gasoline spills, wipe spilled gasoline from the unit or wait until it evaporates before starting engine.
· Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.
· Check fuel lines, tank, cap, and fittings frequently for cracks or leaks. Replace if necessary.
· DO NOT light a cigarette or smoke. · DO NOT fill the tank when the generator is running
or hot. · DO NOT pump gasoline directly into the generator
at the gas station. Use an approved container to transfer the gasoline to the generator.
NOTICE
· Only fill the tank from an approved gasoline container. Make sure the gasoline container is internally clean and in good condition to prevent fuel system contamination.
· Gasoline can damage paint and plastic. Use caution when filling the fuel tank. Damage caused by spilled gasoline is not covered under warranty.
· Clean the fuel screen filter of debris before and after each fueling. Remove the fuel screen filter by slightly compressing it while removing it from the fuel tank.

· It is important to prevent gum deposits from forming in fuel system parts such as the carburetor, fuel hose or tank during storage. Alcohol-blended fuels (called gasohol, ethanol or methanol) can attract moisture, which leads to separation and formation of acids during storage. Acidic gas can damage the fuel system of an engine while in storage. To avoid engine problems, the fuel system should be emptied before storage of 30 days or longer. See the “Long Term Storage” section. Never use engine or carburetor cleaner products in the fuel tank as permanent damage may occur.
Add Fuel: Propane/LPG
DANGER
Propane/LPG is highly flammable and explosive. Fire or explosion can cause severe burns or death. · The provided propane/LPG hose with regulator,
works with standard 20, 30 and 40 pound capacity cylinders with Type 1, right hand Acme threads. Verify the re-qualification date on the tank has not expired. Do not use rusted or damaged cylinders. · Only use provided propane/LPG hose for safe propane operation.
1. Make certain both gasoline and propane/LPG valves are closed.
2. Remove the rubber protective plugs (if it is avaiable) and attach the propane/LPG hose with regulator to the propane/LPG inlet located on the side control panel of the generator. Tighten with a 19mm or adjustable wrench. DO NOT over-tighten.
3. Remove safety plug from the propane/LPG cylinder valve (if it is available) and attach the other end of the propane/LPG hose with regulator to cylinder valve. Tighten the nut by hand clockwise to a positive stop.
IMPORTANT: DO NOT use thread seal tape or any type of sealant to seal the propane LPG hose connections.

Page 17

4. Open valve on propane LPG cylinder and check all connections for leaks by wetting the fittings with a solution of soap and water. Bubbles which appear or bubbles which grow indicate that a leak exists. If a leak exists at a fitting, then turn off the valve on the cylinder and tighten the fitting. Turn the valve back on and recheck the fitting with the soap and water solution. If the leak continues or if the leak is not at a fitting, then do not use the generator and contact customer service.
NOTICE
· Use only an approved LPG cylinder equipped with an OPD (overfilling prevention device) valve.
· DO NOT check for leaks with a lighted match or flame.
· The propane cylinder valve should be fully closed when the generator is not in use or is running with gasoline.
· The regulator/hose assembly and cylinder valve must be inspected before each use for leaks or sign of damages.
· All new cylinders must be purged of air and moisture prior to filling. Used cylinders that have not been plugged or kept closed must also be purged. The purging process should be done by your propane gas supplier.
· Propane/LPG is heavier than air and can accumulate in confined spaces and low places in the event of a leak
· Propane/LPG has a distinctive odor added to help detect potential leaks quickly.
· In case of a petroleum gas fire, do not attempt to extinguish the flame if the fuel supply valve is in the ON position. Introducing an extinguisher to a generator with an open fuel supply valve could create an explosion hazard.
· When exchanging propane/ LPG cylinders, be sure the cylinder valve is of the same type.

· Always keep the propane/LPG cylinder in an upright position.
· Propane/LPG will burn skin if it comes in contact with it. Keep Propane/LPG away from skin at all times.
· Always position the cylinder so the connection between the valve and the regulator won’t cause bends or kinks in the hose.
· DO NOT light or smoke cigarettes while you are connecting the propane/LPG cylinder.Check the fuel system periodically for leaks or signs of damages.
· In the event of an LPG fire, flames should not be extinguished unless by doing so the fuel supply valve can be turned off. If the fire is extinguished and a supply of fuel is not turned off, an explosion hazard greater than the fire hazard could be created.
DANGER
Do not start generator if you smell propane. Always fully close the propane tank valve and disconnect the propane/LPG hose from the generator when not in use.
Operation at High Altitude
At altitudes over 5,000 feet(1524 meters), a minimum 85 octane gasoline is acceptable. Engine power and generator output will be reduced approximately 3.5% for every 1000 feet (305 m) of elevation above sea level. High altitude may cause hard starting, increased fuel consumption and spark plug fouling. To operate at high altitudes A-iPower can provide a high altitude carburetor main jet. The alternative main jet and installation instructions can be obtained by contacting Customer Support.
NOTICE
Operation using an alternative main jet at elevations lower than the recommended minimum altitude can damage the engine. For operation at lower elevations, the standard main jet supplied must be used. Operating the engine with the wrong main jet may increase exhaust emissions, fuel consumption and reduce performance.

Page 18

Grounding
WARNING
Shock hazard. Failure to properly ground the generator can result in electric shock. The national electrical requires your generator must be connected properly to an appropriate ground to help prevent electric shock. The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles. There may be Federal or State regulations, local codes, or ordinances that apply to the intended use of the generator. Consult a qualified electrician, electrical inspector, or the local agency having jurisdiction. This generator is not intended to be used at a construction site or similar activity as defined by NFPA 70-2020 (NEC) section 590.6. Connecting to a Building’s Electrical System Connections to your home’s electrical system must use a listed transfer switch installed by a licensed electrician. The connection must isolate the generator power from the utility power and comply with all applicable laws and electrical codes.
Page 19

OPERATION
Generator Location
WARNING
Make sure you review each warning in order to prevent fire hazard.
Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.

Surge suppressors come in single- or multi-outlet styles. They’re designed to protect against virtually all short-duration voltage fluctuations.
Before Starting the Generator
· Make certain the generator is on a flat, level surface and well-ventilated location. Check for loose or missing parts and for any damage which may have occurred during shipment.
· Check oil level and connect the battery cable.

NEVER use inside a home or garage, Only use OUTSIDE and far away EVEN IF doors and windows are open. from windows, doors and vents.
Avoid other generator hazards. READ MANUAL BEFORE USE.

DANGER

Never use generator in wet or damp locations. Never expose generator to rain, snow, water spray or standing water while in use. Protect generator from all hazardous weather conditions. Moisture, or ice can cause a short circuit or other malfunction in the electric circuit. Water contact with a power source if not avoided, will result in death or serious injury.
· Keep area clear of inflammables or other hazardous materials.
· Select a site that is dry, well ventilated and protected from the weather.
· Keep exhaust pipe clear of foreign objects. · Keep generator away from open flame. · Keep generator on a stable and level surface. · Do not block generator air vents with paper or
other material.
Surge Protection
Electronic devices, including computers and many programmable appliances use components that are designed to operate within a narrow voltage range and may be affected by momentary voltage fluctuations. While there is no way to prevent voltage fluctuations, you can take steps to protect sensitive electronic equipment. Install UL1449, CSA-listed, plug-in surge suppressors on the outlets feeding your sensitive equipment.

· Disconnect all electrical loads from the generator. Never start or stop the generator with electrical devices plugged in or turned on.
Starting the Engine (Generator) Select the Fuel Source (Gasoline) 1. Make certain the propane tank is fully closed.

Page 20

2. Add gasoline to the fuel tank.

5. Electric start Turn and hold the ENGINE START/STOP switch for 5 seconds until the engine start.

3. Turn the battery switch to the “ON”(l) position.

Electric
5. Recoil start Move the choke lever to the “START” position.

4. Flip the fuel source switch on the side panel to the gasoline position.

Pull recoil starter slowly until resistance is felt, then pull rapidly.

Move the chock lever to the “RUN” position.

5. Remote start Turn and hold the REMOTE START switch for 5 seconds until the engine start.

Recoil
Select the Fuel Source (Propane/LPG) 1. Connect the LPG gas hose to the propane fuel
source.

Remote

Page 21

2. Fully open the Propane/LPG cylinder knob.

5. Electric start Turn and hold the ENGINE START/STOP switch for 5 seconds until the engine start.

3. Turn the battery switch to the “ON”(l) position.

Electric
5. Recoil start Move the choke lever to the “START” position.

4. Flip the fuel source switch on the side panel to the propane/LPG position.

Pull recoil starter slowly until resistance is felt, then pull rapidly.

Move the chock lever to the “RUN” position.

5. Remote start Turn and hold the REMOTE START switch for 5 seconds until the engine start.
Remote

Recoil
WARNING
Starter cord kickback (rapid retraction) will pull hand and arm toward engine faster than you can let go which could cause broken bones, fractures, bruises, or sprains resulting in serious injury.
When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback.
NOTE: Keep choke lever in “START” position for only 1 pull of the recoil starter. After first pull, move choke lever to the “RUN” position for up to the next 3 pulls of the recoil starter. Too much choke leads to spark plug

Page 22

fouling/engine flooding due to the lack of incoming air. This will cause the engine not to start. If engine starts after 3 pulls but fails to run. Or if unit shuts down during operation, make sure unit is on a level surface and check for proper oil level in crankcase. This unit may be equipped with a low oil protection device. If so, oil must be at proper level for engine to start.
Connecting Electrical Loads
This unit has been pretested and adjusted to handle its full capacity. Before starting the generator, disconnect all loads. Apply load only after generator is running. Voltage is regulated via the engine speed adjusted at the factory for correct output. Re-adjusting will void warranty.
NOTE: When applying a load, do not exceed the maximum wattage rating of the generator when using one or more receptacles. Also, do not exceed the amperage rating of any one receptacle. Do not apply heavy electrical load during break- in period (the first five hours of operations). 1. Let engine stabilize and warm up for a few minutes
after starting. 2. Ensure circuit breaker on control panel is in on
position. 3. Plug in and turn on the desired 120 or 240 Volt
AC, single phase, 60Hz electrical loads. It is better to attach the item with largest load first.

2. Push STOP on the remote start key fob for 3 seconds.
Push and hold the START/STOP button for 3 seconds.
3. Flip the engine switch to “STOP” position. Do not leave the generator until it has completely stopped.

4. Turn the propane/LPG cylinder knob to close position.
Stopping the Engine (Generator) 1. Turn off and remove entire electrical loads. Never
start or stop the generator with electrical devices plugged in or turned on. Let the generator run at no-load for two minutes to stabilize internal temperatures of the engine and generator.
Page 23

5. Turn off the battery switch to “OFF” position .
DANGER

1. Start the generator with no electrical load attached. 2. Allow the engine to run for several minutes to
stabilize. 3. Plug in and turn on the first item. It is best to
attach the item with the largest load first. 4. Allow the engine to stabilize. 5. Plug in and turn on the next item. 6. Allow the engine to stabilize. 7. Repeat steps 5-6 for each additional item.
Changing Fuels
DANGER

Gasoline, gasoline vapor and propane/LPG are highly flammable and explosive. Fire or explosion can cause severe burns or death.
NOTE: DO NOT stop the engine by moving choke control to “START” position. Always ensure that the gasoline valve is on the “OFF” position and propane/LPG cylinder fully closed when the engine is not in use. If the engine will not be used for a period of two weeks or longer, please see the Storage section for proper engine and fuel storage.
Low Oil Shutdown
If the engine oil drops below a preset level, an oil switch will stop the engine. Check oil level with dipstick. If oil level is between LOW and HIGH mark on dipstick: 1. DO NOT try to restart the engine. 2. Contact an Authorized Service Dealer. 3. DO NOT operate engine until oil level is corrected. If oil level is below LOW mark on dipstick: 1. Add oil to bring level to HIGH mark. 2. Restart engine and if the engine stops again a low
oil condition may still exist. DO NOT try to restart the engine. 3. Contact Customer Service. 4. DO NOT operate engine until oil level is corrected.

Gasoline, gasoline vapor and propane/LPG are highly flammable and explosive. Fire or explosion can cause severe burns or death.
DANGER
DO NOT add gasoline to the gasoline tank or connect the Propane/LPG hose to the generator while the generator is running. 1.Disconnect all electrical loads from the generator.
2. Stop the engine (generator). See the “Stopping the Engine (Generator)” section for stopping procedure.

Do Not Overload Generator
Overloading a generator in excess of its rated wattage capacity can result in damage to the generator and to connected electrical devices. To prolong the life of your generator and attached devices, follow these steps to add electrical load:

Page 24

Gasoline to propane/LPG 3.1 Fully open the Propane/LPG cylinder knob.

4. Start the engine (generator). See the “Starting the Engine (Generator)” section for starting procedure.

3.2 Flip the fuel source switch on the side panel to the propane/LPG position.

Propane/LPG to Gasoline 3.1 Make certain the propane tank is fully closed.
3.2 Flip the fuel source switch on the side panel to the gasoline position.

Page 25

MAINTENANCE AND STORAGE

MAINTENANCE SCHEDULE
Regular Maintenance will improve the performance and extend the life of your generator. Follow maintenance schedule intervals whichever occurs first according to use.
NOTE: Adverse conditions will require more frequent services.
Walk-Around Inspection Before starting the engine perform a visual inspection of the unit. Look for: · Proper engine oil level · Proper fuel level · Fluid leaks · Loose clamps and bolts · Cracked fuel line · Loose or frayed wiring · Built up debris · Propane/LPG connections,regulators and hoses for
leaks
Before Each Use
Check engine oil level Walk-around inspection Check damage and leaks for LPG Regulator/Hose Assy.
First 5 Hours (Break-In)
Change engine oil
First 25 Hours or First Month
Change engine oil Every 100 Hours or 6 Months
Change engine oil Clean Air Filter
Inspect/Adjust/Replace Spark plug Inspect/Clean/Replace Spark Arrester
Every 200 Hours or 12 Months
Replace Air filter Replace Spark Plug Inspect/Adjust Valve Clearance*

  • To be performed by authorized service center
    NOTE: Change oil every month when operating under heavy load or high temperatures. Clean the air filter more often under dirty or dusty operating conditions. Replace air filter if they cannot be adequately cleaned.

NOTE: Maintenance should be performed more frequently when generator is used in dusty areas. When generator has exceeded the maximum figures specified in the table, maintenance should still be cycled according tothe intervals of time or hours stated herein.
General Recommendations Regular maintenance will improve the performance and extend the life of the generator. See any authorized dealer for service. The generator’s warranty does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, the operator must maintain the generator as instructed in this manual. Some adjustments will need to be made periodically to properly maintain your generator. All service and adjustments should be made at least once each season. Follow the requirements in the Maintenanc Shedule chart above.
ENGINE MAINTENANCE To prevent accidental starting, remove and ground spark plug wire before performing any service.
Engine Oil Level Check
CAUTION
Avoid skin contact with engine oil. Wear protective clothing and equipment. Wash all exposed skin with soap and water.
NOTICE
Always use the specified engine oil. Failure to use the specified engine oil can cause accelerated wear and/or shorten the life of the engine.
When using the generator under extreme, dirty, dusty conditions or in extremely hot weather, change the oil more frequently. Ambient air temperature will affect engine oil performance. Change the type of engine oil used based on weather conditions.

Page 26

Recommended Engine Oil Type 10W-30

5W-30

10W-40

5W-30 Full Synthetic

¢’ -20

0

20

40

60

80 100 120

¢$ -28.9 -17.8 -6.7 4.4 15.6 26.7 37.8 48.9

Ambient temperature

Check the engine oil level before each use or every 8 hours of operation. 1. Place the generator on a level surface and allow
the engine to cool for several minutes. 2. With a damp rag, clean around the oil dipstick. 3. Remove the oil dipstick (A). 4. Wipe the dipstick clean, then screw dipstick into
filler neck (B). Remove the dipstick and verify that the oil level is within safe operating range. 5. If low, add recommended engine oil incrementally and recheck until the level is between the L and H marks on the dipstick. DO NOT overfill. If over the full mark on the dipstick, drain the oil to reduce the oil level to the full mark. 6. Replace the oil dipstick and hand-tighten.

CAUTION
Avoid prolonged or repeated skin contact with used motor oil. 1. Remove the oil cap (A) and wipe dipstick clean. 2. Place a container underneath the oil drain plug to
collect used lubricant as it drains. 3. Unscrew the oil drain plug (C) and remove. 4. Allow lubricant to drain completely. NOTE: Drain the lubricant while the engine is still warm but not hot. Warm lubricant will drain quickly and more completely. 5. Reinstall the oil drain plug (C) and tighten securely. 6. Fill the engine with oil until it reaches the HIGH(H)
level on the oil filler cap. 7. Reinstall the oil cap.
H L
A

C

A B

Safe Operating Range
H L

Change Engine Oil
Change engine oil per maintenance schedule. If you are using your generator under extremely dirty or dusty conditions, or in extremely hot weather, change the oil more often.
WARNING
Risk of burns. Allow engine to cool before draining oil or coolant. Failure to do so could result in death of serious injury.

If contaminated or deteriorated oil is used or the quantity of the engine oil is not sufficient, engine damage will result and its life will be greatly shortened. Maximum oil capacity: 23.7 fl.oz (0.7 L)
Spark Plug Maintenance
The spark plug must be properly gapped and free of deposits in order to ensure proper engine operation. To check: 1. Remove the spark plug cap (B). 2. Clean any dirt from around base of spark plug. 3. Remove spark plug (A) using provided wrench. 4. Inspect spark plug for damage, and clean with a
wire brush before reinstalling. If insulator is cracked or chipped, spark plug should be replaced. 5. Measure plug gap. The correct gap is 0.028-0.031 in. (0.7-0.8 mm). To widen gap, if necessary, carefully bend the ground (top) electrode. To lessen gap, gently tap ground electrode on a hard surface. 6. Seat spark plug in position; thread in by hand to prevent cross-threading.

Page 27

7. Tighten with wrench to compress washer. If spark plug is new, use 1/2 turn to compress washer appropriate amount. If reusing old spark plug, use 1/8 to 1/4 turn for proper washer compression. NOTE: An improperly tightened spark plug will become very hot and could damage the engine.
8. Reinstall the spark plug cap (B).

A

B

A – Spark plug B – Spark plug cap
0.7 – 0.8 mm 0.028 – 0.031 in.
Air Filter Maintenance For proper performance and long life, keep air filter clean. 1. Turn the knob (A) on the bottom of air the filter
cover to release. Remove cover (B) and set aside. 2. Remove the filter element (C). 3. If the filter element is dirty, clean with warm,
soapy water. Rinse and let dry. 4. Apply a light coat of engine lubricant to the
element, then squeeze it out. 5. Replace the element (C) in the air filter unit(D). 6. Replace the air filter cover (B) and fasten knob (A).
D C B

Battery Replacement
WARNING
Burn hazard. The battery contains sulfuric acid (electrolyte) which is highly corrosive and poisonous. Wear protective clothing and eye protection when working near the battery. Keep children away from the battery.
CAUTION
Battery posts, terminals contain lead and lead compounds. Wash hands after handling.
1. Remove spark plug wire from the spark plug. 2. Disconnect positive cable (A) and negative cable
(B) from the battery by removing bolts (M6x12) and nuts (M6) from the negative and positive battery posts. 3. Remove the battery strap(D) from the battery box(C). 4. Replace the battery with new battery. Battery specifications: 12V, 7Ah sealed lead acid. LxWxH: 5.42.64.0 inch (13865101 mm) 5. Secure the battery to the battery box with a battery strap. 6. Connect the positive cable with red boot first and then connect the negative cable with black boot. Tighten the bolts and nuts and cover them with boots. 7. Install the spark plug wire onto the spark plug.
NOTICE
Dispose of the used battery properly according to the guidelines established by your local or state government.
A
B
C D

A – Knob

A

B – Air filter cover C – Filter element

D – Air filter unit

Page 28

Cleaning the Spark Arrestor
1. Allow the engine to cool completely before servicing the spark arrestor.
2. Loosen the screw (A) to be able to remove clamp (B) and spark arrestor (C).
3. Carefully remove the carbon deposits from the spark arrestor screen with a wire brush.
4. Replace the spark arrestor if it is damaged. 5. Position the spark arrestor on the muffler and
attach with the screws removed in step 2.
NOTE: This product is equipped with a spark arrestor that has been evaluated by the USDA Forest Service; however, product users must comply with Federal, State, and local fire prevention regulations. Check with appropriate authorities. Contact customer service or a qualified service center to purchase a replacement spark arrestor.
BC

GENERATOR MAINTENANCE
Make certain that the generator is kept clean and stored properly. Only operate the unit on a flat, level surface in a clean, dry operating environment. DO NOT expose the unit to extreme conditions, excessive dust, dirt, moisture or corrosive vapours.
NOTE: DO NOT use a garden hose to clean the generator. Water can enter the generator through the cooling slots and damage the generator windings. Use a damp cloth to clean exterior surfaces of the generator. Use a soft bristle brush to remove dirt and oil. Use an air compressor 25 PSI (172 kPa) to clear dirt and debris from the generator. Inspect all air vents and cooling slots to ensure that they are clean and unobstructed.
STORAGE It is recommended to start and run the generator for 30 minutes, every 30 days. If this is not possible, refer to below short term and long term storage.

Short Term Storage

A

Fill the tank with fresh gasoline and add gasoline

stabilizer. Drain the carburetor float bowl.

1 – Add a properly formulated FUEL STABILIZER to

the tank if it is not already added.

2 – Run the engine for 10-15 minutes to circulate

stabilizer throughout fuel system.

3 – Allow the generator to cool a minimum of 30

minutes and then drain the carburetor float bowl.

4 – Clean the generator and store in a cool, dry and

well ventilated area out of direct sunlight.

Valve Clearance

Long Term Storage (over one year)

Important: Please contact Authorized Service Center for service assistance. Proper valve clearance is essential for prolonging the life of the engine. Check valve clearance per maintenance schedule.

For long term storage, the gasoline tank and carburetor must be drained of gasoline. 1 – After engine cools down, remove all gasoline
from the fuel tank using non-conductive siphon.

Intake Valve

Exhaust Valve

Valve Clearance

0.004~0.006 inch 0.1~0.15 mm

0.006~0.008 inch 0.15~0.2 mm

Torque

10-12 N·M

10-12 N·M

2 – To remove the remaining gasoline in fuel system: a-Keep the fuel valve open and run the engine until it stops from lack of fuel. Or b-Keep the fuel valve open and drain carburetor

NOTICE

float bowl. 3 – Change the engine oil.

Checking and adjusting valve clearance must be

4 – Remove the spark plug.

done when the engine is cold.

5 – Pour tablespoon( 5-10cc) of clean engine oil into

cylinder.

Page 29

6 – Pull starter recoil several times to distribute oil in cylinder.
7 – Install spark plug. 8 – Pull recoil slowly until resistance is felt. This
close valves so moisture cannot enter engine cylinder. Gently release recoil. 9 – Clean the generator and store in a cool, dry and well ventilated area out of direct sunlight.
DRAINING THE FLOAT BOWL 1. Turn the fuel tank valve to the OFF position. 2. Locate the drain screw on the bottom of the
carburetor float bowl. 3. Place an appropriate gasoline container under the
drain screw to catch the drained fuel. 4. Loosen the float bowl drain screw and allow the
fuel to drain. Tighten the float bowl drain screw.
DANGER
Explosion and Fire. Fuel and vapors are extremely flammable and explosive. Store fuel in a well ventilated area. Keep fire and spark away. Failure to do so will result in death or serious injury.
WARNING
Risk of Fire. Verify machine has properly cooled before installing cover and storing machine. Hot surfaces could result in fire.
Float bowl Drain screw
Page 30

TROUBLE SHOOTING

PROBLEM
Engine is running, but no AC output is available.
Engine runs well at no-load, but “bogs down” when loads is connected.

POSSIBLE CAUSE
1. AC Circuit breaker is open. 2. Fault in generator. 3. Poor connection or defective cord set. 4. Connected device is bad. 5. GFCI outlet is open (if equipped)
1. Short circuit in a connected load. 2. Engine speed is too slow. 3. Generator is overloaded. 4. Shorted generator circuit. 5. Clogged or dirty fuel filter. 6. Connected device is bad.

SOLUTION
1. Check AC load and reset circuit breaker. 2. Contact customer service or authorized service center. 3. Check and repair. 4. Connect another device that is in good condition. 5. Correct ground fault and press reset button on GFCI outlet.
1. Disconnect shorted electrical load. 2. Contact customer service or authorized service center. 3. Reduce load. 4. Contact customer service or authorized service center. 5. Clean or replace fuel filter. 6. Connect another device that is in good condition.

Engine will not start; starts and runs rough or shuts down when running.

1. Fuel source switch is in OFF position

1. Move to gasoline or propane/LPG position.

2.Low oil level.

2. Fill crankcase to proper level or place generator on

3. Dirty air filter.

level surface.

4. Out of fuel.

3. Clean or replace air cleaner.

5. Stale fuel.

4. Fill fuel tank.

6. Spark plug wire not connected to spark plug. 5. Drain fuel tank and carburetor; fill with fresh fuel.

7. Bad spark plug.

6. Connect wire to spark plug.

8. Water in fuel.

7. Replace spark plug.

9. Flooded.

8. Drain gas tank and carburetor; fill with fresh fuel.

10. Excessively rich fuel mixture.

9. Wait 5 minutes and re-crank engine.

11. Intake valve stuck open or closed.

10. Contact customer service or authorized service center.

12. Engine has lost compression.

11. Contact customer service or authorized service center.

13. Clogged or dirty fuel filter.

12. Contact customer service or authorized service center.

14. Clogged or dirty spark arrester screen. 13. Replace fuel filter.

15. Out of propane/LPG.

14. Clean or replace spark arrester screen.

16. LPG cylinder knob / propane supply valve 15. Replace LPG cylinder/ check propane/LPG supply.

is not open.

16. Fully open LPG cylinder knob / propane/LPG supply

17. Shut off due to CO accumulation &

17. Follow all safety instructions on CO Action Label.

blinking red indicator light

18. Contact customer service or authorized service center.

18. Shut off due to a system fault & blinking

yellow indicator light

Engine lacks power.

1. Load is too high. 2. Dirty air filter. 3. Clogged or dirty fuel filter. 4. Clogged or dirty spark arrester screen. 5. Engine needs to be serviced. 6. Bad fuel.

Engine”hunts”or falters. 1. Carburetor is running too rich or too lean. 2. Clogged or dirty fuel filter. 3. Choke is opened too soon.

1. Reduce load. 2. Replace air filter. 3. Clean or replace fuel filter. 4. Clean or replace spark arrester screen. 5. Contact customer service or authorized service center . 6. Drain gas tank and carburetor; fill with fresh fuel.
1. Contact customer service or authorized service center . 2. Replace fuel filter. 3. Set choke to halfway position until engine runs smootly.

Engine shuts down when running.

1. Out of fuel. 2. Dirty air cleaner. 3. Low oil level. 4. Out of gasoline or propane/LPG.

1. Fill fuel tank. 2. Clean or replace air cleaner. 3. Fill crankcase to proper level or place generator on
level surface. 4. Fill fuel tank with gasoline or replace LPG cylinder/
check propane/LPG supply.

Page 31

Page 32

92 91 90 89 88 87
86 85

151 150

149

152 153 154 155
156

84

97

83

98

82

93 94 95
96

62
61 60
4445 59 58 57 56

55 65

160 161 162 163
66 67 68

12

5

6 7 8 1213 14 15 18 19 20

31 33 34 63

34

11 9 10 16

17 21 22 23

32 35 26 27 36

24

25

28 29 30

64

69

79

52 54

70 71

73

72 74

37 38 39 40

78 80 81

41 42 43 53 44 45 46 76 77

47 48 49 50

115 114 113 112 111 110 109 108 107 106 105 104 103
102 101 100 99
75

52 51

159

148

141 142 143 144 145
133 134 135

140 139 138 137 136
129
130 131 132

116 117 157 158 164 165 166 139 118 119 120

GXS6600RD
167 168 169 170 171

147 146
128 127 126 125 124 123 122 121

PARTS DIAGRAM AND PARTS LIST
PARTS DIAGRAM (MACHINE)

Parts List

NO. Part Number

Description

1 30101-00042-00 Hex flange bolt M6*20

2 20021-00044-00 Cylinder cover components

3 34024-00003-00 Clamp

4 34023-00017-00 Exhaust hose

5 33048-00312-00 Cylinder head gasket

6 30101-00041-00 Hex flange bolt M6*10

7 34021-00317-00 Cylinder head air guide cover

8 20027-00010-00 Spark plug components

9 34019-00036-00 Valve rocker arm assy.

10 30150-00028-00 External circlip

11 30134-00029-00 Valve rocker arm assy.

12 34016-00106-00 Valve collet

13 34015-00091-00 Valve spring

14 34016-00105-00 Exhaust valve spring seat

15 30110-00027-00 Air exhaust stud

16 30101-00710-00 Hex flange bolt M8*40

17 34018-00005-00 Intake valve oil shield

18 30101-00544-00 Hex flange bolt M10*50

19 20023-00067-00 Cylinder head assy.

20 34006-00007-00 Locating pin

21 30110-00018-00 Air inlet stud

22 33048-00317-00 Air inlet gasket

23 34012-00039-00 Carburetor connection block

24 33048-00316-00 Carburetor gasket

25 /

Carburetor assy.

26 34024-00002-00 Clamp

27 34023-00004-00 Fuel hose

28 33048-00318-00 Air filter gasket

29 30125-00002-00 Hex flange nut M6

30 20025-00260-00 Air filter assy.

31 33048-00313-00 Cylinder head gasket

32 34020-00030-00 Valve pushrod

33 34013-00128-00 Exhaust valve

34 34013-00092-00 Intake valve

35 34008-00004-00 Valve tappet

36 20084-00102-00 Piston ring components

37 34004-00081-00 Piston

38 30150-00022-00 Piston pin circlip

Qty.

NO. Part Number

Description

Qty.

4

39 34006-00013-00 Piston pin

1

1

40 20008-00035-00 Connecting rod assy.

1

1

41 30101-00487-00 Hex flange bolt M10*15

2

1

42 30136-00078-00 Aluminum gasket

2

1

43 34011-00134-00 Crankcase

1

6

44 30141-00157-00 Deep groove ball bearing

2

1

45 34007-00028-00 Oil seal

2

1

46 33099-00165-00 Flywheel

1

2

47 33155-00167-00 Fan

1

2

48 34022-00040-00 Startup cup

1

2

49 30125-00065-00 Hex flange nut M14

1

4

50 20010-00490-00 Recoil assy.

1

2

51 30101-00414-00 Hex flange bolt M6*35

4

2

52 30101-00042-00 Hex flange bolt M6*20

2

2

53 20249-00570-00 Support components

1

1

54 20022-00072-00 Governor assy.

1

1

55 33247-00028-00 Oil sensor

1

4

56 30101-00342-00 Hex flange bolt M6*16

2

1

57 20013-00020-00 Speed control gear assy.

1

2

58 34006-00001-00 Locating pin

2

2

59 33048-00314-00 Crankcase cover gasket

1

1

60 20026-00069-00 Dipstick components

1

1

61 33129-00104-00 Crankcase cover

1

1

62 30101-00461-00 Hex flange bolt M8*32

7

1

63 20012-00042-00 Camshaft assy.

1

1

64 20011-00221-00 Crankshaft assy.

1

0.25

65 34015-00089-00 Return spring

1

1

66 34025-00022-00 Speed control arm components 1

2

67 34015-00088-00 Fine adjustment spring

1

1

68 34026-00041-00 Speed control rod

1

1

69 34007-00081-00 Oil seal

1

2

70 34006-00016-00 Locking clip of locating pin

1

1

71 30136-00092-00 Swing rod gasket

2

1

72 34026-00040-00 Speed control swing rod

1

2

73 20149-00169-02 Starting motor components

1

1

74 33246-00003-00 Engine oil alarm

1

1

75 34024-00131-00 Cable clip

2

2

76 /

Ignition coil assy.

1

Page 33

NO. Part Number

Description

Qty.

NO. Part Number Description

Qty.

77 30101-00408-00 Hex flange bolt M6*25

4

115 34023-00064-00 Gas hose

0.35

78 20009-00064-00 Charging coil components

1

116 20090-02367-00 Frame assy.

1

79 30101-00539-00 Hex flange bolt M8*35

2

117 30125-00023-00 Hex flange nut M8

4

80 33593-00327-00 Crimp plate

1

118 20014-00815-00 Support bracket assy.

2

81 30101-00070-00 Hex flange bolt M6*12

3

119 34030-00256-00 Damping pad

2

82 20029-12622-00 Generator assy.

1

120 30101-00355-00 Hex flange bolt M8*16

5

83 30101-00079-00 Hex flange bolt M6*140

4

121 30101-00405-00 Hex flange bolt M6*20

2

84 33085-00011-01 Generator bracket

1

122 30125-00019-00 Hex flange nut M6

2

85 /

Terminal

1

123 33015-00007-00 Handle rubber sleeve

1

86 30101-00329-00 Hex flange bolt M5*16

5

124 20135-00458-00 Handle tube assy.

1

87 30136-00016-00 Flat washer

1

125 33580-00033-00 Handle fixing pin

2

88 30101-00105-00 Hex flange bolt M10*225

1

126 33126-00001-00 Plug

2

89 /

Carbon brush

1

127 34006-00020-00 Locking clip of locating pin

2

90 20044-00015-00 Voltage regulator

1

128 30136-00086-00 Flat washer

2

91 30101-00326-00 Hex flange bolt M5*12

1

129 30101-00405-00 Hex flange bolt M6*20

4

92 33082-00162-00 Motor tail cover

1

130 34038-00003-00 Carbon canister

1

93 20202-01063-00 Muffler assembly

1

131 33593-00018-00 Carbon canister pressure plate A 1

94 30121-00007-00 Hexagon nut M8

2

132 33593-00024-00 Carbon canister pressure plate B 1

95 30139-00036-00 Spring washer

2

133 30101-00339-00 Hex flange bolt M6*12

6

96 33048-00315-00 Muffler gasket

1

134 30125-00023-00 Hex flange nut M8

4

97 30101-00355-00 Hex flange nut M8*16

1

135 34030-00010-00 Vibration damping support

4

98 30136-00115-00 Flat washer

1

136 34024-00025-00 Clamp

2

99 33141-00120-00 Hub cover

2

137 34023-00345-00 Vent hose

1

100 34031-00038-00 Wheel axle

2

138 34023-00346-00 Vent hose

1

101 20134-00346-00 Wheel

2

139 30125-00003-00 Hex flange nut M8

2

102 20033-00115-00 Pressure reducing valve assy. 1

140 34024-00032-00 Clamp

2

103 33001-00167-00 Elbow joint

2

141 34024-00003-00 Clamp

1

104 34023-00064-00 Gas hose

0.30

142 34037-00003-00 Filter screen

1

105 20133-00046-00 Oil and gas transfer switch assy. 1

143 40052-00006-00 Sylphon bellows

0.2

106 33014-01665-00 Side baffle

1

144 34023-00436-00 Fuel hose

1

107 31026-00294-00 Switch handle

1

145 34024-00024-00 Clamp

1

108 30111-00072-00 Philip pan head screw

1

146 30136-00074-00 Fuel tank gasket

4

109 31026-00338-00 Switch handle

1

147 30101-00407-00 Hex flange bolt M6*25

4

110 70002-02338-00 Dust cap

1

148 20130-00618-01 Fuel tank assy.

1

111 70002-02895-00 Joint assy.

1

149 20114-06680-00 Panel assy.

112 30111-00088-00 Philip pan head screw

3

150 20115-00096-01 CO alarm

1

113 34024-00060-00 Hoop

6

151 30112-00032-00 Anti-theft bolt

2

114 34023-00064-00 Gas hose

0.40

152 30101-00339-00 Hex flange bolt M6*12

1

Page 34

NO. Part Number

Description

Qty.

153 20196-00114-00 Wire hardness assy.

1

154 33301-00010-00 Plum shaped spring washer

1

155 30125-00019-00 Hex flange nut M6

1

156 20196-04317-00 Wire hardness assy.

1

157 31002-00019-00 Battery

1

158 70002-02285-00 Battery strap

1

159 33089-00510-00 Remote control box

1

160 40052-00019-00 Sylphon bellows

0.2

161 60008-00023-00 Nylon cable tie

5

162 33499-00035-00 Air filter bracket

1

163 33138-00017-00 Dustproof rubber

1

164 33624-00025-01 Support seat assy.

2

165 30101-00370-00 Hex flange bolt M8*40

2

166 30136-00014-00 Flat washer

2

167 31034-00041-00 30 AMP RV adapter

1

168 70009-00999-00 Spark plug wrench

1

169 20033-00051-00 Propane/LPG hose with regulator 1

170 /

Remote control fob

1

171 20196-00137-00 12V DC Battery Charging Cable 1

Page 35

Circuit Diagram Page 36

CIRCUIT DIAGRAM
Grounding system(AC): Neutral Floating

Model: GXS6600RD

Grounding system(DC): System Floating

ALTERNATOR
Main coil Main coil

B

B 22A

W

W

W
VHzT

B
22A

30A
W
Y/G

B
20A
W

Voltage transfer switch

B1

2

3

B

4

5

6

B7

8

9

W

W

10 11 12

B Y/G

Y/G

L 9A L
DC coil

USB R
DC08 B
KBPC2510 R
12V 12V DC 8.3A B

SIDE CONTROL PANEL Fuel source switch

LPG switch

GAS switch

1 23456

G

G

1

LPG

G/W 2 OFF

3

GAS

B

4

5

6
B

Stepping motor

L PYOR

Br L

Oil warning indicator LED

PLG OYR

Learning switch

2 1

Sub coil Field coil

L Br Y Y AVR Y
L

Y Oil alarm Oil sensor

R B

O O 43 12

Fuse8A

W G Br Br

Spark Ignition plug coil

Battery charging coil

fuel cut solenoid

Starting motor

BB
Temperature sensor
ENGINE

CONTROL PANEL

BGLRY

ENGNE
START STOP

BAT
Key
Engine switch BAT Key
OFF ON

CO indicator light

Red light

Red light

W Gy Y R

BO

Br

Br

G

CO sensor module

B:BLACK Br:BROWN

G:GREEN Gy:GRAY

L:BLUE O:ORANGE

R:RED W:WHITE

Y:YELLOW P:PINK

B/W:BLACK/WHITE Y/G:YELLOW/GREEN

R/W:RED/WHITE

WARRANTY

LIMITED WARRANTY

“Consumer Use” – residential household use by a

KEEP YOUR RECEIPT. Proof of purchase will be required to substantiate any warranty claim. WHAT IS COVERED: A-iPower Corp. warrants to the

retail consumer. “Commercial Use” – all other use – commercial , business, industrial, or rental purpose.

original retail purchaser in the United States of America, or Canada that this product is free of defects in material and workmanship and agrees, at A-iPower Corp’s direction, to either repair, provide replacement parts for, or replace (without charge for parts or labor) any product or component with a material defect for a period of 3 years from the date

How to Obtain Warranty Service
Please call our Customer Service Dept. 855-888-3598 or e-mail to support@a-ipower.com Please have necessary information available – Model Number, Serial Number, Proof of Purchase.

of purchase, except as limited below. Warranty service and replacement parts are warranted only for the duration of the warranty on the original product. All replaced parts or products become a property of A-iPower Corp. This product is also covered by an Emissions Control System Warranty which is separate from and in addition to the warranty.

DO NOT RETURN THE PRODUCT TO THE PLACE OF PURCHASE
A-iPower Customer Service Dept will assist with all product related questions and will help troubleshoot issues and will send any replacement parts as necessary while product is within the warranty period at no charge. If the issue cannot be resolved then A-iPower Customer Service Dept at its discretion

WARRANTY
A-iPower Limited Warranty ­ 3 Years Residential and 1 Year Commercial. 3 years Residential warranty applies as follow: 1st year Parts & Labor / 2nd & 3rd year Parts ONLY.

determine and authorize diagnosis and repair through one of its authorized Service Centers. A-iPower Corp at its discretion may choose to provide replace of part, component, or product. Service or replacement of parts at any unauthorized repair facility without prior authorization will not be

Thank you for choosing A-iPower products. To

covered by this warranty.

ensure proper registration of your product warranty, please submit your warranty registration along with proof of purchase within 10 days of the date of purchase, this can be done by a) Completing the Warranty Registration form at the
back of this manual and mailing to: A-IPOWER CORP 10887 COMMERCE WAY UNIT A FONTANA CA 92337 USA. b) Visit us at www.a-ipower.com and click the product registration icon.

Warranty Exclusions
This warranty does not cover the following: Regular wear and maintenance – this warranty will not cover repair when normal use has exhausted the lifetime of a part(s) or engine. Installation and Maintenance – this warranty does not cover improper or unauthorized assembly, alteration, modification or any other damage resulting from misuse or neglect. Normal maintenance parts – this warranty does not cover spark plugs, air filters, adjustments, or other

Warranty Term

related service due to obstructions and other build

A-iPower will provide warranty for any of its products purchased through any authorized AiPower dealer in North America to the original purchaser and will be warranted against defects in material or workmanship for a period of three (3) years for Consumer use from date of purchase, subject to exclusions noted herein. Commercial and Rental applications are warranted for a period of one (1) year from date of purchase.

ups resulting from improper maintenance. Additional exclusions – this warranty does not cover wearable parts such as filers, spark plugs, o-rings, batteries etc. It does not cover any cosmetic defects such as scratches to paint, decals etc. It does not cover any damage resulting from use of non-original manufacturer’s parts, use of aftermarket parts. It does not cover any failures due to acts of God and

Page 37

other force majeure events beyond the control of the manufacturer.
Warranty limits and Implications and Consequential Damages A-iPower is not obligated to cover any loss of time, use of product, freight cost, or any other incidental or consequential claim from the use of this product. This warranty is in Lieu of all other warranties, express or implied. This warranty gives you specific legal rights which vary from state to state.
MERCHANDISE RETURN GUIDELINES · All products must be returned in original or
equivalent packaging. Improperly packaged returns will not be accepted. · Must have adequate packing for transportation. · Federal Law requires that all machines that utilize gasoline, oil, or other flammable liquids must be drained Completely & Thoroughly prior to shipment. · Gas caps and oil plugs must be left off for 24 hours prior to shipping. Please note: liability for this violation of the law resides with the sender of the shipment. · Return to address provided in return authorization, using the parcel service required. Units returned without authorization will not be honored. · Please Note: Refunds will not be granted for items that have been modified or damaged by abuse or usage not in accordance with product instructions.
Page 38

Fontana, CA 92337 USA Phone: 855-888-3598 support@a-ipower.com
www.a-ipower.com

A-iPOWER WARRANTY REGISTRATION FORM

Register your product by emailing this form to support@a-ipower.com or register on-line at: www.a-ipower.com.
Registering your product is important , it provides the following protections:
1. You have record of product purchased 2. Customer Service can Better serve you for Warranty related issues 3.

Customer Information:

Product Information:

Name: Phone: E-mail: __ Address: City, State: __ Zip code: ___ Purchase Date:


Serial #
Model #
The serial No. can be found on the engine. PLEASE NOTE: Your product cannot be registered without model & serial numbers.

1.THE PRODUCT WAS PURCHASED FOR: A. Residential cleaning

2.THIS PRODUCT IS A: (select one)

B. Other ____

A. First time purchase

B. Replacement

3.HOW DID YOU FIRST LEARN OF THIS PRODUCT: (select one)

A. Radio B. Store Display C. Contractor D. Trade Show

G. Direct Mail H. From Friend/Relative/Neighbor I. Internet J. Other


4. PLEASE RATE THE

Completly

Not at all

FOLLOWING:

5

4

3

2

1

Product Value for Price Paid

Performance

Features

Product Appearance

Warranty

Ease of Maintenance

Noise Level

5 . HOW LIKELY ARE YOU TO RECOMMEND A-iPOWER TO FAMILY OR FRIENDS?

Extremely

Not Likely

Likely

at all

5

4

3

2

1

Privacy Statement: A-ipower is committed to respecting your privacy and to complying with the regulations regarding the protection of personal data. The survey data we collect is for the purposes of marketing or product support and demographic information about the entire audience registering their products.

Fontana, CA 92337 USA Phone: 855-888-3598 support@a-ipower.com
www.a-ipower.com