A-iPOWER SUA2000i 2000 Watt Portable Inverter Generator User Guide

October 26, 2023
A-iPOWER

SUA2000i 2000 Watt Portable Inverter Generator
User Guide

Unpack Generator: Remove the generator, accessories, inserts, and Literature from the carton. If any item is missing or damaged, contact our product service department at 1-855-888-3598.

Included Items

Muere el rey, ¿viva el rey? - Copi...

Muere el rey, ¿viva el rey? - Copilotos E8 | T1

A-iPOWER SUA2000i 2000 Watt Portable Inverter Generator -
item

WARNING
This Quick Reference Guide is not a substitute for reading the operator’s manual. To reduce the risk of injury or death, users must read and understand the operator’s manual before using this product. All pages reference the operator’s manual.

Add Lubricant and Fuel

Use a funnel to pour 10W-30 engine oil into the engine. Fill to the upper mark of the oil dipstick H.

A-iPOWER SUA2000i 2000 Watt Portable Inverter Generator - Figure
1

Use clean/fresh regular UNLEADED gasoline with a minimum 87 octane.

Start Generator

Move the generator outside to a flat, level surface, away from doors, windows and vents.

DANGER
Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.

NEVER use inside a home or garage, EVEN IF doors and windows are open.

Only use OUTSIDE and far away from windows, doors, and vents.
Avoid other generator hazards. READ THE MANUAL BEFORE USE.

WARNING
Do not overload the generator or electrical cords. Consult operation manual.

  1. Turn the fuel cap vent lever to the “ON” position.

  2. Turn the Starting Dial Switch to the “START” position.

  3. Pull recoil starter slowly until resistance is felt, then pull rapidly.

  4. As soon as the engine starts and warms up, turn the Starting Dial Switch to the “RUN” position.

  5. Plug in items to be powered, using only grounded extension cords.

Shutdown and Storage

  1. Remove any load from the generator.

  2. Turn the Starting Dial Switch to the “STOP”  position.

  3. Turn the fuel cap vent lever to the “OFF” position.

If the generator is to be stored for longer than 30 days, refer to the operator’s manual for further instructions.