ROCKSOLAR BLP Series Pure Sine Wave Inverter User Manual
- June 12, 2024
- ROCKSOLAR
Table of Contents
- Please keep it properly after reading
- Accessories:
- Attention and warning
- Product Description
- Inverter application
- Appearance
- Product installation
- Display function
- Display and Control panel
- Display and control panel
- Total Harmonic Distortion (THD)
- General technical requirements
- DC input wire requirements
- Product features
- Customer Support
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ROCKSOLAR BLP Series Pure Sine Wave Inverter
Please keep it properly after reading
In order to ensure reliable service for you, the inverter must be installed and used properly. Before installation and use, please read the installation and operating instructions. Please pay special attention to the warnings and theirs explanation in this manual, for some warning of use conditions and practice caution that can lead to inverter damage. And the clear warning statement for certain conditions of use and practices which are likely to cause personal injury. Read all tips before using the inverter.
Please read this instruction manual carefully to facilitate the correct use. Especially before using, please remember to read the details of the “Safety Precautions” to ensure safe use. After reading the instruction manual, please keep it properly for future reference.
Accessories:
Remote control panel
(Optional, need to be purchased separately).
Attention and warning
- Be sure to read this manual carefully before use;
- The machine should be handled with care
- If the equipment is damaged due to failure of installation in accordance with this manual, company reserves the right not to carry out quality assurance.
Caution the surface with high temperature Attention surface a haute temperature.
- Warning To prevent fire, do not cover or block the ventilation holes. Do not install inverter in zero clearance compartments, which may cause overheating.
- The machine itself has overload protection to prevent overload. Do not operate or install on a flammable surface. Reverse polarity can damage the device.
- To avoid harm to you and others, here we list all precautions as below, please be sure to follow, please refer to the description for the meaning of various signs.
Flammable gas
Sparks when connecting the battery before connecting, make sure there is no
flammable gas.
The battery will be easy to emit flammable gas while charging and discharging.
Requesting well ventilation, do not put it in the places which will accumulate
flammable gas.
Prohibition In parallel with city power
The output can not be connected in parallel with the mains, which will damage
the inverter and cause the electric shock.
Prohibition of minors
Can not be used by minors, inverter has a high voltage output, which may lead
risk of electric shock.
No disassembly
Do not disassemble or modify this inverter. Unauthorized disassembly or
modification may cause malfunction, and security incidents such as fire
disasters or electric shocks.
Prohibition contact with sticks
Do not place a stick or other metal object in the inverter hole or jack, which
may touch internal parts to cause electric shock and damage to the inverter.
Do not touch with wet hands
Do not touch the inverter body and the plug with wet hands, this may cause
electric shock and personal safety.
Keep away from flames and high temperature area
Operating in flame and high temperature area, may lead inverters and batteries
to occur fire or explosion.
No collision
Crashing the inverter will cause the damage and other safety risks.
Prohibition for medical devices
The inverter can not be used for medical equipment before testing.
Ground wire connection
For electricity safety, please connect the inverter to ground, or may cause a
safety accident.
Moisture proof and waterproof
Please pay attention to moisture and water proof, inverter may cause short
circuit, fire and electric shock because of moisture or water.
Complete insertion
Please insert the load device plug into the inverter socket completely. If the
plug is not fully inserted at the end, it may lead to electric shock and
overheating, and even cause a fire accident. Do not use damaged Plugs, power
outlets, electrical wires.
Product Description
Thank you very much for choosing our products and thanks for your trust and
support. At present, our products have gotten Chinese and foreign customer’s
consistent praise. We sincerely hope that this product can meet your needs, at
the same time, we hope that you can give more advices about the performance
and function of our product, we will continue to improve the quality of our
products. Should you have any abnormalities during use, please contact us
immediately, we will provide the fastest service for your satisfaction.
BLP series, the remote controlled intelligent inverter, is a newest power
solution developed by our company for complex power demand, as users in the
digital age have a higher demand for efficiency and flexibility.
User-friendly design, innovation and fashion elements of BLP series inverters
enable us to seamlessly experience in complex application loads and perfect
solution of security, reliability, plug-and-play.
BLP series inverter is a kind of power device that converts direct current
(battery, solar cell, wind turbine, etc.) to alternating current. This series
of inverters can be used for home, outdoor, car, boat and other environments.
The inverter uses a wired remote control display panel to show the working
status of the inverter and turn on/off function. The inverter function can be
set through display control panel button on the host, to meet the needs of
different user.
Remotely controllable multi-function intelligent inverter
- Support wired remote control
- Multiple protection functions
- High conversion efficiency
- Adjustable parameters
- Multiple output interface
- Plug and play
- Full metal casing
- Intelligent cooling fan
Provide input DC12V/24V, output AC100V/AC110V/115V/120V
A variety of power 1 000W / 2000W / 3000W ….. .
A variety of combinations for your choice
Power supply for vehicle equipment
Solar/ Home power generation
power supply for ship equipment
Inverter application
The inverters of BLP series can be the core component of the solar off grid power generation system as well as the independent power supply system.
Off-grid solar power generation system configuration diagram
Inverter, solar controller, solar
panel, battery can form a set of off-grid solar power generation systems.
Inverter independent power supply configuration diagram
The inverter and the battery can form an independent power supply
system, the loaded equipment and the lime of use depend on the inverter output
power and battery capacity. The inverter can not charge the battery. If you
need to charge the battery, please purchase a charger separately.
BLP series pure sine wave inverter can be used for home, office, car, boat and outdoor emergency power supply, can be used in the following types electrical appliances:
- household appliances: TV, speakers, amplifiers, refrigerators, air conditioners, electric fans, induction cookers, microwave ovens, electric ovens, consumer ,poison cabinets, hair dryers, electric heaters, vacuum cleaners, fruit oars, rice cookers, water heaters …
- Office equipment: computers, printers, copiers, network equipment, projectors.
- Lighting equipment: LED lights, white lights, fluorescent lights, energy-saving lamps.
- Power tools: electric drills, cutting machines, fans, pumps, hand grinders .
Rated current and actual equipment
The BLP series inverter is a pure sine wave inverter, and its output waveform
is the same as mains. The nominal current or power of most electric tools,
household appliances, and audio-visual equipment is within the nominal power
range of the inverter, but there will an overload protection when starting
some electrical equipment.
Some audio and video equipment and electric tools have to be more than
resistive load level of power for working preper, asynchronous motors, CRT TV,
compressor, water pump, etc. request 2 to 6 times of working current when
starting. Weather it can run depends on the test.
This series of inverters CAN NOT be used for medical equipment.”
Pure sine wave working diagram
Appearance
Product Size
BLP1000ARW-/BLP1000BRW- product Size
BLP2000ARW-/BLP2000BRW - product Size
BLP3000ARW-/BLP3000BRW- product Size
Appearance diagram
American standard regular socket and American standard GFCI socket
Product installation
Product Installation
Production installation flowchart
Unpacking inspection
Please check the body if any damage when unpacking and contact the supplier immediately if the machine is obviously deformed. Please check the label of the device to confirm if the model, input power, input voltage, and output voltage meet the requirements of your purchase. You can confirm the appearance, structure and model refer to the specification. If any missing parts or damage in transportation, please contact our after-sales department in time and keep the packaging materials for future transportation.
Check the product manual
In order to ensure the product to work normally, please check the manual carefully before using and keep it properly.
Operating environment
In order to ensure the perfect performance and long lifespan of the product, the installation location of the inverter should be protected from the following conditions,
- This product should be placed indoors and well ventilated;
- Avoid using in direct sunlight, exposure, rain, high humidity, corrosive gas and mechanical shock;
- Working temperature/humidity is -20-40°C/10-90%RH, no condensation. Storage temperature/ humidity -30-60 ° C I 10-95% RH;
- The package drop test follows the IATA standard.
Operation equipment connection
Connection diagram
Installation and connection steps, refer to the connection diagram
- Connect the negative pole of the battery to the black terminal of the inverter with a black cable;
- Connect the positive pole of the battery to the red terminal of the inverter with a red cable;
- Connect the remote control panel to the remote output interface of the inverter;
- Turn on the power switch of the inverter;
- Connect the power plug of the loaded equipment to the output socket of the inverter.
Removal steps:
- Turn off the power switch of the inverter;
- Remove the remote control panel.
- Unplug the power plug of the load.
- Remove the battery positive cable;
- Remove the battery negative cable;
Warnings
- The wiring diagram is only for basic reference. Please contact a professional technician for actual installation.
- Inverter must be connected to the battery, same as nominal voltage, 12V inverter connects 12V battery and 24V inverter connects 24V battery;
- Appropriate cable should be used when installing and connecting output cables, such as 11 0V output cable is too long or the cross-sectional area of the wire when it is too small, it will generate a lot of power loss on the cable, 1000W load uses cable ?16AWG, 2000W load use cable ?14AWG, 3000W load ? 12AWG.
- The connection cable between the battery and the inverter is not standard, like overlength cabel, too small cross-sectional area and poor contact in connection, it may cause lots of power loss, performance as insufficient output power, low battery voltage, short working time, even not working with alarm when tum on. At the same time, the cable should have waterproof function and insulation strength to meet the requirements of the use environment.
- When choosing a battery for the inverter, it is better to choose a battery with 1 00AH or larger capacity.
Installation guide
- Whether you buy the wire from the original factory or use your own one, the wires must have the copper wire with enough carrying.
- The wire is connected from the battery to the fuse and then to the host, the fuse will provide the insurance in case of fault. If using isolation switch, make sure the fuse rating matching the host power.
- For ships or vehicles, it is recommended to use multiple AC flexible cables.
Remote control installation
When the inverter host is closed, connecting one end of the communication line with a magnetic ring to the inverter host, and the other end to the wiring port of the remote panel.
Installation dimension drawing
BLP1 000ARW-/BLP1 000BRW- Inverter installation size
BLP2000ARW-/BLP2000BRW- Inverter installation size
BLP3000ARW-/BLP3000BRW- Inverter installation size
Model
| BLP1000ARW-• I| BLP2000ARW- I| BLP3000ARW-| BLP1000BRW-| BLP2000BRW-|
**BLP3000BRW-***
---|---|---|---|---|---|---
Output| Rated Power|
1000W (30 minutes 900W (continuous)
2ooow (30 minutes1800W(continuous)
3000W (30 minutes) 2700W(continuous
|
1000W
| 2000W|
3000W
AC Voltage
|
100V/110V/115V/120V
Frequency
|
50Hz/60Hz Adjustable)
Peak Power
| 2000W| I| 4000W I| 6000W| 2000W| 4000W| 6000W
Total Harmonic Distortion(THD)|
“”
Input|
Battery Voltage
| 12V| 24V
Voltage Range| 9V-17V|
18V-32V
DCCUrrent
| 96A| I| 194A I| 291A|
46A
|
92A
| 139A
No load Consumption
| 1.2A| I| 1.5A I| 2A| 0.6A| 0.7A| 1.1A
Quiescent Current in Shutdown Mode| 1mA| 1mA|
1mA
| 1mA
Max Efficiency(full load)
| 90%| 91%
Battery Type|
lithium battery, lead acid battery, valve control battery and gel battery;
Battery input protection
|
Fuse
| 35A4| I| 300A”1 I| 400A”1| 40A2| 150A”1| 200A”1
Low Battery Alarm| 9.5/10/10.5/11/11.5/12/12.SV, Buzzer alarm, E06 in LED
monitor|
19/20/21/22/23/24/ZSV, Buzzer alarm, EOG in LED monitor
Recovery of Battery Low
Voltage Alarm
| 10/10.5/11/11.5/12/12.5/BV| 20/21/22/23/24/25/26V
Low voltage Protection
| 9/9.5/10/10.5/11/11.5/12V(Adjustable) , E01 in LED monitor, inverter will turn off automatically in 305|
18/19/20/21/22/23/24V(Adjustable) , E01 in LED monitor, inverter will turn off automatically in 305
Recovery of Low Voltage Protection| Recovery in 30S:11/11.5/12/12.5/13/13.5/14V|
Recovery in 30S:22/23/24/25/26/27/28V
High Voltage Protection
| 17V, E02 in LED monitor, inverter will turn off automatically in
305
| 32V, E02 in LED monitor, inverter will turn off automatically in
305
Recovery of High Voltage Protection
| Recovery in 305: 16.SV|
Recovery in 305: 31V
Battery reverse connection protection|
When input DC polarity is connected reversely, the fuse will blow to protect the parts of the inverter from being damaged
Output protection
| High Temperature Alann|
Buzzer alarm, E07 in LED monitor
Over Temperature
| Buzzer alarm, inverter stops working with E04 in LED monitor, recovery after
temperature reduction
Short Circuit|
Short circuit protection is locked, buzzer alarm, E03 in LED monitor, inverter will turn off automatically in 305
Over Load Alarm
| Buzzer alarm, E0B in LED monitor
Overload Alarm|
Buzzer alarm , E05 in LED monitor, inverter will turn off automatically in 305
USB
|
Single USB output Voltage
| 5V/9V
Single USB output Current|
2.1A
Working environment
|
Cooling Method
| Internal fan of the machine
Working Temperature|
-20-40-C
Working Humidity
| 10-90%RH
Storage Temperature/Humidity},|
-30″C-+70″C, 10-95%RH
Packing
| N.W.| 2820g I 5010g I 6640g| 2820g| 5010g| 6640g
Size/mm (LxWxH)
| 357.5•112•1a I 420.4″208.9″110 I 517.4″208.9’110|
357.517278| 420.4’208.9″110| 517.4″208.9″110
Remark|
All the parameters are measured in environment temperature 25°C if not specified.
Display function
**Host display: three-digit LED seven-segment digital tube for display
**
BAT: When VBAT is lit, it indicates DC input voltage.
VINv, When VINv is lit, it indicates the inverter output voltage.
POWER: When the POWER is lit, it indicates the inverter output power.
VAC: This machine does not have this feature.
ICHG: This machine does not have this feature.
ERR: When ERR is lit, it indicates that the inverter has a fault or
warning.
You can check the fault information through the error code of the digital
display tube.
Inverter fault and removal method
Er r or code
| Malfunction| Fault description| Method of exclusion
---|---|---|---
**** E01| Battery low voltage protection| The battery voltage is too low and
the inverter automatically turns off the output.|
Check if the battery cable is loose or check if the battery capacity is too small
**** E02
| Battery High Voltage Protection| The battery voltage is too high and the
inverter automatically turns off the output.| Check the battery voltage or
determine if there is an external charger connection that causes the voltage
to be too high
**** E03| Inverter Output Short-circuit Protection| Inverter output short
circuit inverter automatically closes output|
Check if the AC output cable is shorted. Disconnect or reduce the electrical load and turn the inverter back on
**** E04
| Inverter Over Temperature Protection| The internal temperature of the machine is
too high and the inverter automatically turns off the output.
| Check if the ventilation of the machine is good and the working
environment temperature is too high. Wait for the machine to automatically cool down and automatically restore the output.
**** E05| Inverter Overload Protection| The inverter output is overloaded and the inverter automatically turns off the output.|
Check if the power load is too large, disconnect or reduce the cower load, and turn the inverter back on.
E06
| Battery Low Voltage Alarm| Low battery voltage, machine alarm| Turn off the
load and charge the battery
E07| Inverter Over Temperature Alarm| The internal temperature of the machine
is too high, close to the limit of the machine|
Reduce the electrical load and check if the machine is well ventilated and the ambient temperature is too high.
EOB
| Inverter Overload Alarm| The power load is too large, close to the limit of the machine| Reduce the electrical load
**** E09
|
Inverter Output Over Voltage Protection
|
**** Inverter output voltage is too high
|
Disconnect the power load, turn the machine back on, and check if the machine is normal.
Wired remote control panel with LCD display
Display and Control panel
Keystroke tone:
Press the Power, Select, Menu button at any time, and the buzzer will emit a short beep.
Inverter On/Off:
Turn the inverter on/off, and press the power button on the display panel for
about 1 second and hear the beeped sound.
Three LED seven-segment digital tube for display:
- When the inverter is working, the LED digital screen alternately displays: “battery voltage”, “inverter output voltage”, “inverter output power”
- When the inverter fails, the LED digital screen displays the corresponding error code.
Press the button ‘Menu’ to view the current inverter display status:
- When the DC input voltage is displayed, the LED screen displays ‘VBAT’, and the three-segment digital tube displays: ‘*.’V
- When the AC output voltage, the LED screen displays ‘VINV’, the three-segment digital tube displays: ‘***’V.
- When the inverter AC output power, the LED screen displays ‘Power’, the three-segment digital tube displays: ‘*.**’KW.
Press the button ‘Select’ to view the current inverter settings status:
- View inverter output frequency setting LED screen display: ’50: output frequency 50HZ’/’ 60: output frequency 60HZ ‘
- When viewing the inverter function low voltage protection setting, the LED display shows: ‘9’, ‘9.5’, ‘1 0’, ‘10.5’, ’11 ‘, ’11 .5′, ’12’ (12V inverter low voltage protection setting) ’18’, ’19’, ’20’, ’21 ‘, ’22’, ’23’, ’24’ (24V inverter low voltage protection setting)
- When viewing the buzzer alarm on/off function setting, the LED display shows: ‘ALO: buzzer off’, ‘AL 1: buzzer on’
- View inverter AC output voltage setting, LED display shows: ‘100: Inverter output voltage 1OOVAC’,’110: Inverter output voltage 11 0VAC’,’115: Inverter output voltage 115VAC’,’ 120: Inverter output Voltage 120VAC’
- Inverter AC output function setting, LED screen display: ‘IN1: Inverter default setting mode’,’IN2: Inverter power saving mode’, ‘IN3: Inverter automatic shutdown mode’
Inverter function settings:
-
Press the ‘menu’ button for 5s, and the inverter enters the function setting menu mode:
-
LED screen display: ‘FE’ indicates the frequency setting menu, press ‘Select’ button 1 s to enter the output frequency setting: ’50: output frequency rate 50HZ’/’60: Output frequency 60HZ’, the output frequency can be set by ‘Select’ button. After the selection is completed, press ‘Menu’ button 5s, you can save settings and exit the menu setting function; If you need to continue to set other functions, press the ‘Menu’ button for 1 second to enter the next menu setting. After the next menu is set, press the ‘Menu’ button for 5s, you can save ii together with the last setting, after the save is completed, the menu setting function will be automatically exited.
-
LED screen display: ‘LV’ indicates the battery low voltage protection setting menu, press ‘Select’ button 1 s to select the battery low voltage protection voltage:
‘9’, ‘9.5’, ‘1 0’, ‘10.5’, ’11 ‘, ‘11.5’, ’12’ (12V inverter low voltage protection setting) ’18’, ’19’, ’20’, ’21’, ’22’, ’23’, ’24’ (24Vinverter low voltage protection setting) After the selection is completed, press the ‘Menu’ button for 5s to save the settings and exit the menu setting function; if you need to continue to set other functions, press the ‘Menu’ button for 1 second to enter the next menu setting. After the next menu is set, press the ‘Menu’ button for 5s to save the last set function together. After saving, the menu setting function will be automatically exited. -
LED screen display: ‘AL’ indicates buzzer alarm setting menu: ‘Select’ button 1s,select buzzer setting:’AL0: buzzer off’, ‘AL 1: Buzzer on’; after the selection is completed, press the ‘Menu’ button for 5s to save the settings and exit the menu setting function; If you need to continue to set other functions, press the ‘Menu’ button for 1 second to enter the next menu setting. After the next menu is set, press the ‘Menu’ button for 5s to save the last set function together. After saving, the menu setting function will be automatically exited.
-
LED screen display: ‘out’ indicates the inverter AC output voltage setting menu: press ‘Select’ button 1 s to select inverter AC output voltage setting:’100: Inverter output voltage 1 00VAC’, ‘110: Inverter output voltage 11 0VAC’, ‘115: Inverter output voltage 115VAC, ‘120: Inverter output voltage 120VAC. After the selection is completed, press ‘menu’ key 5s, you can save settings and exit the menu setting function; If you need to continue to set other functions, press ‘Menu’ key 1 s, will go to the next menu setting. After the next menu is set, press the ‘Menu’ button for 5s to save the last set function together. After saving, the menu setting function will be automatically exited.
-
LED screen display: ‘IN’ inverter function setting menu: ‘Select’ key 1 s, enter inverter function setting’IN1: inverter default recognize setting mode’, ‘IN2′: Inverter power saving mode’, ‘ln3: Inverter automatic shutdown mode’. After the selection is complete. press ‘Menu’ button 5s, you can save settings and exit the menu setting function; lf you need to continue to set other functions, press ‘Menu’ The key 1 swill enter the next menu setting. After the next menu is set, press the ‘Menu’ button for 5s to save the last setting together. The function will automatically exit the menu setting function after saving.
IN1: Inverter default setting mode; when the inverter is turned on, the inverter continues working unless there is a fault.
IN2: Inverter power saving mode; if the AC power load is less than 1 OW after the inverter is turned on, the inverter will automatically shut down AC output, until the AC power load is larger than 1 OW, the inverter automatically turns on the AC output.
IN3 : Inverter automatic shutdown mode: if the load power is less than 1 OW within 30m in after the inverter is turned on, the inverter will turn off the AC output and shutdown automatically. -
LED screen display: ‘DEF’ restores the factory default menu settings. When this mode is set, the factory function settings will be automatically restored: Inverter output frequency: 60HZ, battery low voltage protection voltage: 10V/20v, buzzer alarm: AL 1, inverter output voltage:11 0V, the inverter function is set to: default mode ‘IN 1 ‘. Press ‘Menu’ for 5s to save settings and exit menu setting function; if you need to continue to set other functions, press ‘Menu’ button 1 s, it will enter the next menu setting. In the next menu after setting, press ‘Menu’ button for 5s to save the last set function together. After saving, it will automatically exit the menu.
Display and control panel
Total Harmonic Distortion (THD)
The THO of the output: < 5%
General technical requirements
Operation and storage temperature requirements:
- Normal working temperature: 2 5 ‘C
- Operating temperature range: -20~ 45’C
- Storage temperature range: – 30~ 60 ‘C
Operation and storage humidity requirements
- Normal working humidity range: 1 0 – 90 %RH
- Storage humidity range: 10 – 95 %R
Packaging Drop Test Requirements
Packaging drop test follows IATA standards
Corrosion resistance requirements
All metal parts are treated with oxidation
DC input wire requirements
- BLP-3000S-12V-* Wiring: #3/0 AWG (American Standard) or National Standard 80mm2 Wire length: 1.5 meters max.
- BLP-3000S-24V-* Wiring: #2 AWG (American Standard) or National Standard 30mm2 Wire length: 1.5 meters max.
- BLP-2000S-12V-* Wiring: #2/0 AWG {American Standard) or National Standard 50mm2 Wire length: 1.5 meters max.
- BLP-2000S-24V-* Wiring: #2 AWG (American Standard)) or national standard 30mm2 Wire length: 1.5 meters max.
- BLP-1000S-12V -*Wiring: #2 AWG (American Standard)) or national standard 30mm2 Wire length: 1.5 meters max.
- BLP-1000S-24V-* Wiring: #5 AWG (American Standard) National Standard 16mm2 Wire length: 1.5 meters max.
Product features
Provide fan with intelligent control to reduce the running noise effectively, high efficiency operation;
- Touch switch;
- Provide remote control by wired control panel;
- Dual frequency setting, which can be switched between 50Hz and 60Hz frequency;
- Adjustable minimum voltage for low voltage protection of the battery;
- Long lifespan in extreme environmental conditions;
- Output voltage AC 1 00V, AC 110Vand AC 115V and AC120Vcan be set;
- Low no-load current, saving energy without load;
- High load capacity can bear relatively large loads and handle stably in case of overload;
- Support a variety of batteries, battery types such as lithium battery, lead acid battery, valve control battery and gel battery;
- Provide a variety of intelligent protection:
- battery low voltage protection and alarm
- battery over voltage protection
- overload protection and alarm
- short circuit protection 5, high temperature protection and alarm
- Provide input/output voltage display functions and USB output;
- Plug and play maintenance-free design ensures long-term continuous operation
- This product is made of metal shell, anti-oxidation process, beautiful appearance.
Customer Support
ROCKSOLAR TECHNOLOGY LLC.
Address: 500 DELAWARE AVE,STE 1 #1960 WILMINGTON,DE,US,19899
Tel: 1-800-858-4318
Email: services@rocksolars.com
Website: www.rocksolars.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>