Jandy Pro Series JVA 2444 Valve Actuator
WARNING
FOR YOUR SAFETY – This product must be installed and serviced by a contractor
who is licensed and qualified in pool equipment by the jurisdiction in which
the product will be installed where such state or local requirements exist.
The maintainer must be a professional with sufficient experience in pool
equipment installation and maintenance so that all of the instructions in this
manual can be followed exactly. Before installing this product, read and
follow all warning notices and instructions that accompany this product.
Failure to follow warning notices and instructions may result in property
damage, personal injury, or death. Improper installation and/or operation will
void the warranty.
Improper installation and/or operation can create unwanted electrical hazard
which can cause serious injury, property damage, or death.
ATTENTION INSTALLER – This manual contains important information about
the installation, operation and safe use of this product. This information
should be given to the owner/operator of this equipment.
Section 1. Safety Information
IMPORTANT SAFETY INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS
READ AND FOLLOW ALL INSTRUCTIONS
When installing and using this electrical equipment, basic safety precautions
should always be followed, including the following:
WARNING This manual contains important information about the installation, operation and safe use of this product. This information should be given to the owner/operator of this equipment.
WARNING This product must be installed and serviced by professionals who
are qualified in pool/spa product installation and service. Improper
installation and/or operation can create an unwanted electrical hazard which
can cause serious injury, property damage, or death. Improper installation
and/or operation will void the warranty.
Disconnect power to the system at the main circuit breaker before servicing to
avoid risk of electric shock which can result in property damage, severe
injury or death. All wiring must be done in accordance with the National
Electrical Code® (NEC®), NFPA-70. In Canada, all wiring must be done in
accordance with the Canadian Electrical Code
(CSA C22.1). All applicable local installation codes and regulations must be
followed.
Section 2. General Information
Introduction
This manual contains information for the proper installation and operation of
Jandy® Pro Series Valve Actuators (JVA). Procedures in this manual must be
followed exactly. To obtain additional copies of this manual visit
www.zodiacpoolsystems.com. For address
information, see back cover.
Description
Valve Actuators are designed to meet the needs of today’s more advanced,
automatic pool equipment. These fully adjustable actuators offer versatile
pool/spa automation with easy setups. All actuators work with AquaLink® RS
Control Systems and are available in 24 volt units.
JVA 2444 Specifications
Voltage| 24 VAC
Amperage| 0.75 AMPS
Cycles| 60 Hz
Wire| 3-conductor
Black| Common
Red| Switch Leg
White| Switch Leg
Section 3. JVA Mounting Positions
Standard JVA Position
Standard Plumbing position is with the middle port (B) as the incoming or
common port to the valve (see Figure 1).
Standard Mounting
Position is with the main body of the actuator over port B (see Figure 2).
NOTE If the valve(s) are plumbed with port B as the common port (Standard
Plumbing) and the main body of the actuator(s) are mounted over port B
(Standard Mounting), there is no need to adjust the actuator cams.
Actuator Mounting
JVA’s mount directly on all full-size Jandy Pro Series Valves (8 screws on
lid). Zodiac recommends motorizing Jandy Pro Series Never Lube® Valves only.
JVA’s may be mounted onto valves in any of the four (4) positions in Figure 3.
- Unscrew the locking knob by turning the knob counterclockwise. Remove the locking knob and valve handle (see Figure 4).
- For standard valves, remove the four (4) large Phillips head screws from the valve. The location of the screws you remove will determine how the actuator will be mounted (see Figure 4). When installing the large 3″ valve, it is not necessary to remove any screws. Use the four mounting bosses provided.
- Turn the actuator over so you can see into the clear actuator shaft. There are four (4) “teeth” on the inside of the shaft. Locate the smallest “tooth” and align this “tooth” with the smallest slot on the valve (see Figure 5).
- Place the actuator onto the valve.
- Rotate the actuator while keeping the two shafts engaged until the screw holes on the actuator legs align with the empty screw holes (from step 2) in the valve (see Figure 6).
- Use the four (4) large 2″ Phillips head screws (included with the JVA) to secure the JVA to the valve.
- Put the valve handle on the actuator shaft. Put the knob on the shaft and tighten (finger tighten only).
Section 4. Synchronization
Synchronization Methods
If the valve is plumbed in the Standard Plumbing position and the actuator is
mounted in Standard Mounting position, you do not have to change the cam
settings from the factory settings. However, you may have to synchronize the
cams.
One of the following will occur when the actuator is out of synchronization:
- the actuator will rotate in the wrong direction in relation to its controller (as in a solar heating system)
- one actuator will rotate incorrectly in relation to another actuator (as in pool/spa combinationFigure 7 illustrates an example of the valves and actuators of a pool/spa combination that are out of synchronization. The valve on the left of the illustration (suction) is plumbed with the spa line on the left side of the valve and the pool line on the right; whereas, the valve on the right of the illustration (return) is plumbed with the pool on the left side of the valve and the spa on the right. In this configuration, if the actuators are activated, one will turn to spa while the other will turn to pool. The actuators will have to be synchronized.
On the actuator that is out of synchronization, flip the toggle switch located on the bottom of the actuator to the ON 2 position (see Figure 8). The toggle positions are marked on the actuator top cover. Retry the system.
Resetting the Cams
WARNING Improper cam settings can result in dead heading of the water
flow which can cause injury or property damage. Improper cam settings and/or
operation will void the warranty.
NOTE Before resetting cams, if the valve is plumbed in Standard Plumbing
position and the actuator is in Standard Mounting position there is no need
for resetting the cams (see Figure 9). If a port other than “B” is plumbed as
the common port or if the actuator is mounted other than Standard Mounting,
the cam setting must be changed so the actuator shaft and the valve diverter
rotate properly. Refer to the Cam Setting Chart on page 8 for proper settings.
-
Turn OFF actuator power. Unscrew the locking knob by turning the knob counterclockwise. Remove the locking knob and valve handle.
-
Remove the four (4) Phillips head screws that secure the actuator lid and then remove the lid.
-
Important – Rotate the actuator shaft so the arrow mark on the top cam aligns with the microswitch actuator (bottom cam arrow mark should also align with the bottom microswitch actuator, see Figure 10). Locate the mounting position for the actuator (as per Figure 9, the mounting position will be either I, II, III, or IV). Next, determine what valve port is the common or inlet port (as per Figure 9, the common port will be either A, B, or C). Then refer to the Cam Setting Chart below to determine what the cam settings should be. For example, if the actuator is in JVA mounting position “I”, and the common port on the valve is port “A”, the cam settings would be 90° for the top cam and 180°for the bottom. NOTE The cam is marked with the arrow at “0”, a long hash mark at the 180° position, and 2 short hash marks at the 90° and 270° positions.
-
To set the cams, rotate the cam(s) until the arrow mark on the cam(s) align with the microswitch actuator (see Figure 11).
NOTE The upper cam stops counterclockwise rotation and the lower cam stops clockwise rotation. -
Turn power ON to the actuator and use the toggle switch located on the bottom of the actuator to check rotation. Move the toggle switch to either ON 1 or ON 2. Allow the actuator shaft to move until it stops. Check valve diverter position*, if the position is correct flip the toggle switch in the opposite direction and allow the shaft to stop again. If the stop positions are correct, go to step 6. If they are not, reset the cams until correct.
NOTE If the actuator does not move in either direction, refer to Section 6, Troubleshooting. -
Replace the lid and tighten screws. Replace the handle and locking knob.
NOTE The end of the handle which has the word embossed on it exactly duplicates the shape of the valve diverter. When the handle is placed on a valve or actuator shaft the word OFF will be directly over the center of the valve diverter.
Cam Setting Chart
NOTE Before resetting cams, always rotate the actuator shaft so the arrow mark on each cam aligns with the pointer above its microswitch.
Actuator Mounting| Water Enters Port Common Port| Cam Setting
Top Cam Bottom Cam
| Water Exits Valve Port or Port|
---|---|---|---|---
*I| A| 90
90
180
180
| 180
270
90
90
| B| C|
I
I
| B
C
| A
A
| C
B
|
*II| A| B| C|
II| B| 0| 0| A| C|
II| C| 90
90
270
0
0
180
270
| 180
180
90
270
270
180
0
| A
B A
| B
C C
|
*III| A|
III
III
| B
C
|
A| B|
*IV| A| B
A
| C
C
|
IV
IV
| B
C
|
A| B|
*Two Port Valve Settings| |
Section 5. Manual Operation
Manual Override
It is sometimes necessary to rotate valve(s) manually, without using the
system controller. This occurs when the controller is not
accessible/operational or when the spa or pool/spa combination require filling
or draining.
There are two (2) methods of manually rotating the JVA; one with power on
(system operational) and one with power off (no power to the control system).
CAUTION To prevent damage to your equipment and to minimize the
possibility of any injury resulting from such damage, make sure that the pool
filtration pump is OFF BEFORE rotating the valve handle.
Manual Override, Power On
- Move the toggle switch located on the bottom of the actuator to the opposite position (ON 1 switch to ON 2 or vice versa). This will rotate the motor to the opposite position.
- Return the toggle switch to the original position after use.
Manual Override, Power Off
- Move toggle switch located on the bottom of actuator to the OFF (center) position.
- Unscrew (counterclockwise) the locking knob above the handle four (4) full turns.
- Push down on the locking knob (not the handle). This will disengage the gear train and allow the handle, and thus the valve diverter, to be moved to any position.
- To return the actuator to automatic position, pull up on the handle while turning it clockwise or counterclockwise until you feel the shaft slide up into the gear train. Turn the locking knob down (clockwise) until snug.
- Put toggle switch back to the original position.
Section 6. Maintenance
Actuator
The JVA has three (3) seals which should be lubricated once a year. One o-ring
is located on the bottom of the actuator where the plastic shaft exits the
housing and two (2) O-rings located in the top cover near where the shaft
exits the top of the housing. Use the following steps to lubricate the seals:
- Turn OFF power to the actuator.
- Remove the locking knob and handle (see Figure 13).
- Spread a small amount of Jandy Pro Series Lube or other silicone base lubricant around the actuator shaft just above the lock out ring (see Figure 13).
- Reinstall handle and locking knob. Only tighten knob one (1) turn.
- Push down on the locking knob to force the actuator shaft into manual.
- Wipe a small amount of lubricant around the actuator shaft where it protrudes from the bottom of the actuator.
- Turn handle once around to spread the lubricant.
- Pull up on the handle and tighten locking knob.
Valve
NOTE This section does not apply to Jandy Pro Series Never Lube® Valves
and non-positive seal valves. Never Lube Valves and non-positive seal valves
can be identified by the absence of a grease cap. Never Lube Valves can also
be identified by the name “Never Lube” on the handle.
Since the actuator rotates the valve diverter which redirects the flow of
water, it is imperative that the seals and the O-rings within the valve body
be lubricated often (at least every three (3) months). Use the following
procedure to lubricate the valve diverter seals:
- Turn off all pool/spa equipment.
- Rotate valve handle so the OFF on the handle is over the word GREASE on the valve body.
- Unscrew (counterclockwise) and remove the black cap of the grease fitting.
- Fill cap with lubricant (Jandy Lube).
- Replace cap on fitting and turn in (clockwise) until all of the lubricant has been forced into the valve.
- Use manual operation to move the handle from side to side to spread the lubricant across the seal.
- Reset the valve handle to its original position and start the equipment.
Once a year the valve should be disassembled and the O-ring and valve body inspected for damage. Thoroughly lubricate the square seal and the O-ring. Reassemble the valve.
Section 7. Wiring Diagrams
JVA Wiring Schematic 2444
WARNING Disconnect power to the system at the main circuit breaker before
servicing to avoid risk of electric shock which can result in property damage,
severe injury or death. All wiring must be done in accordance with the
National Electrical Code® (NEC®), NFPA-70.
In Canada, all wiring must be done in accordance with the Canadian Electrical
Code (CSA C22.1). All applicable local installation codes and regulations must
be followed.
CAUTION To avoid damage to the equipment and minimize risk of injury, use
a properly sized, listed Class 2 transformer for connection to the power
supply.
JVA’s with Toggle Switch
This diagram is for two (2) JVA 2444s.
To operate more JVA’s, additional poles and a higher amperage fuse are needed.
Do not double lug the JVA switch leg wires (red and white wires).
- Transformer must be sized for the number of JVA’s. Each JVA requires .75 amp. at 24 VAC.
JVA’s with Time Clock
This diagram is for a single JVA 2444.
To operate more JVA’s, additional poles and a higher amperage fuse are needed.
Do not double lug the JVA switch leg wires (red and white wires).
- Transformer must be sized for the number of JVA’s. Each JVA requires .75 amp. at 24 VAC.
Section 8. Troubleshooting
Troubleshooting
All major components, including the power cord, are replaceable without
replacing the entire actuator. Each item may be replaced as a separate piece
allowing easy infield repair. See Section 8, Exploded Views and Replacement
Kits, for actuator replacement part numbers.
Problem | Cause | Solution/Check |
---|---|---|
Actuator handle oscillates. | Lack of valve seal lubrication. Obstruction in | |
valve body. | Lubricate valve. |
Remove actuator and valve lid and inspect.
Actuator motor works but the valve diverter does not turn.
NOTE On a pool/spa combination, the problem would be spa draining or overflowing.
| A). Actuator shaft broken.
B). Valve diverter broken.
C). Actuator in manual position.
D). Gear train damaged.
| A). Replace actuator shaft. Refer to Shaft Replacement Kit instructions for disassembly.
B). Replace valve diverter.
C). Pull up on the handle while rotating counterclockwise.
D). Refer to Gear Replacement Kit instructions for disassembly.
Actuator motor does not turn.| A) No power to the actuator.
B) Toggle switch in OFF position.
C) Motor has failed.
D) Failed or broken microswitch.
E) Both cams in contact with their microswitches.
| A) Check voltage between black (common) wire and each switch leg (red then white)
B) Move toggle switch to ON 1 or ON 2 position.
C) Replace motor.
D) Replace microswitch.
E) Check Cam Setting section.
Actuator rotates in one direction but not back again.| A) Broken or damaged micro- switch.
B) Bad connection(s).
C) Bad control relay switch.
D) Broken wire.
| A) Replace microswitch.
B) Check all connections.
C) At the power source check the operation of the control relay or switch.
D) Check red and white wires.
Water inside valve actuator.| Damaged seals.| Replace top lid and grease seals.
Section 9. JVA Exploded View and Spare Parts
Dwg. # | Kit # | Description | Qty. |
---|---|---|---|
1 | R0409600 | JVA Gasket and Screw Kit | |
Gasket | 1 | ||
O-ring, | 2 | ||
Screw, #14 x 2″ | 4 | ||
Screw, #8 x 5/8″ | 4 | ||
2 | R0411500 | Top Housing Kit | |
Gasket | 1 | ||
O-ring | 2 | ||
Screw, #8 x 5/8″ | 4 | ||
Housing, Top | 1 | ||
3 | R0408700 | Center Plate Kit | |
O-ring | 2 | ||
Screw, #8 x 5/8″ | 8 | ||
Bridge | 1 | ||
Top Cam (Clear) | 1 | ||
Bottom Cam (Textured) | 1 | ||
Microswitch | 2 | ||
Center Plate | 1 | ||
Output Shaft, Threaded | 1 | ||
Spring, JVA | 1 | ||
4 | R0411600 | Gear Kit | |
Primary Gear | 1 | ||
Secondary Gear | 1 | ||
Large Pinion Gear | 1 | ||
Output Gear | 1 | ||
Housing, Bottom w/3 Pins | 1 | ||
5 | R0411800 | Cable Kit, 20′ | |
O-ring, Strain Relief | 1 | ||
Washer, Strain Relief | 1 | ||
Cap, Strain Relief | 1 | ||
Power Cord, 20′ w/3-pin | 1 | ||
Connector | |||
5 | R0411900 | Cable Kit, 75′ | |
O-ring, Strain Relief | 1 | ||
Washer, Strain Relief | 1 | ||
Cap, Strain Relief | 1 | ||
Power Cord, 75′ w/3-pin | 1 | ||
Connector | |||
6 | R0441700 | PCB w/Toggle Switch Kit | |
PCB Sub-Assy, 24V w/PCB, w/Toggle Switch, Lock Washer and Nut | 1 | ||
7 | R0408500 | Motor Kit | |
Screw, #8 x 5/8″ |
Motor 24V, w/Wire and Connector
| 1
1
8| R0408600| Cam and Microswitch Kit|
| | Top Cam (Clear) Bottom Cam (Textured) Microswitch| 1
1
2
Zodiac Group Australia.
219 Woodpark Road
Smithfield, NSW AU 2164
1.800.688.552 | www.Zodiac.com.au
Zodiac Pool Systems, Inc.
2620 Commerce Way, Vista, CA 92081
1.800.822.7933 | www.ZodiacPoolSystems.com
©2016 Zodiac Pool Systems, Inc. ZODIAC® is a registered trademark of Zodiac
International, S.A.S.U., used under license. All trademarks referenced herein
are the property of their respective owners.
H0570800 Rev J
To ensure best customer service and tracking of warranty, we recommend you
register your product at:
Jandy.com/Registration (USA)
Jandy.ca/Registration (Canada)
JANDY LIMITED WARRANTY
Zodiac Pool Systems LLC, a Fluidra Company (“Fluidra”) warrants all Jandy® branded products to be free from manufacturing defects in materials and workmanship for a period of one (1) year from the date of retail purchase, with the exceptions listed below.
- Variable speed pumps are warranted for three (3) years.
- JXi™ heaters are warranted for one (1) year. Heat Exchangers on JXi Gas Heaters with factory-installed VersaFlo™ Integrated Bypass are warranted for five (5) years.
- Heat pumps are warranted for two (2) years. Heat pump compressors and heat exchangers are warranted for five (5) years.
- Nicheless underwater lights are warranted for three (3) years.
- Complete electronic salt water chlorine systems (controller and cell purchased and installed together) are warranted for three (3) years.
- Those certain Never Lube® valves made from CPVC are warranted for the life of the pool on which they were originally installed. For the avoidance of any doubt, any Never Lube valve made from PVC is only warranted to be free from manufacturing defects in materials and workmanship for a period of one (1) year from the date of retail purchase.
- Refrigerant and other expendables are not warranted.
- Replacement products, or parts, provided at no charge are warranted only until the original finished good’s warranty has expired. Purchased replacement parts are warranted for ninety (90) days from the date of retail purchase, with the exception of electronic salt water chlorine generator cells and electrodes, which are warranted for one (1) year.
- Maintenance tools are warranted for ninety (90) days.
- All Jandy branded products used in a commercial application are warranted for a period of one (1) year from the date of retail purchase, unless a lesser amount of time is stated above in exceptions 1 through 9. A commercial application is defined as any application other than a single-family dwelling.
This Jandy Limited Warranty does not apply to Jandy branded products purchased
through the Internet or other e-commerce platforms, with the exception of
Jandy branded valves less than three (3) inches in diameter, parts, and pool
product accessories.
This warranty applies only to products installed and serviced by a contractor
who is licensed and qualified in pool equipment by the jurisdiction in which
the product will be installed, where such state or local requirements exists.
In the event no such state or local requirement exists, the installer and
maintainer must be a professional with sufficient experience in pool equipment
installation and maintenance. This warranty applies only to products purchased
and utilized in the 50 United States and Canada, is limited to the first
retail purchaser, is not transferable, and does not apply to products that
have been moved from their original installation sites. The liability of
Fluidra shall not exceed the replacement of the defective product or its
parts, and does not include transportation costs, costs for labor to service
or repair the defective product, or any items or materials required to make
the repair including, but not limited to, refrigerant and other expendables.
Fluidra is not responsible for charges or delays incurred when a servicer is
unable to perform service due to lock outs, animals, intolerable pool or spa
water temperature when entry into pool or spa is required to perform service,
service refusals, etc. No reimbursements will be made for loss and/or usage of
water, fuel or other resources resulting from product defect. A third party
service provider may charge the end-user customer for parts and/or labor
required to resolve any issue not covered under warranty, such as improper
installation. Fluidra is not responsible for these charges. Product
discoloration, or any other cosmetic or superficial damage or deterioration,
regardless of its cause, is not covered by this warranty. This warranty does
not cover failures, defects, malfunctions or complaints resulting from any of
the following:
-
Failure to properly install, operate or maintain the product in accordance with Fluidra’s published installation, operation and/or maintenance manuals.
-
Improper equipment sizing or product mis-applications.
-
The workmanship of any installer of the product.
-
Use of non-factory authorized parts or accessories in conjunction with the product(s).
-
Product modifications or adjustments that are not in accordance with Fluidra’s published installation, operation and/or maintenance manuals.
-
Not maintaining proper pool and/or spa chemical balance [pH levels between 7.2 and 7.8, with ideal range being between 7.4 and 7.6; Cyanuric Acid
(CYA) between 30 to 100 ppm; Total Alkalinity (TA) between 80 to 120 ppm (100 to 150 ppm for vinyl pools); Total Dissolved Solids (TDS) less than 1500 ppm, not including salt ppm; and Total (or Calcium) Hardness less than 800 ppm, with an ideal range being between 200 ppm and 400 ppm]. -
Corrosion, erosion, scaling, calcification or other conditions caused by water hardness, chemical imbalance, or lack of product maintenance.
-
Chemical contamination of combustion air; or improper use of pool/spa chemicals, such as introducing chemicals upstream of the heater or cleaner hose, or through the skimmer; or use of copper-based algaecides in conjunction with Nature2 products.
-
Abuse, damage during transit or installation, mis-handling, tampering, vandalism, alterations, accidents, fires, floods, storms, earthquakes, power surges, lightning, pets or other animals, insects and/or their hives or nests, negligence, or acts of God.
-
Not grounding and/or bonding as specified, mis-wiring, loose wiring, cut or kinked wires, loose cable connections, incorrect wire runs, incorrect breaker size, breaker(s) in “off” position, improper wire gauge, moisture in electrical conduit, improper electrical supply, dead batteries, incorrect plumbing, inadequate size of pipe and/or fittings, cross-threading, over-tightening, under-tightening, glue drips or residue, improperly secured covers, improper valve placement or usage, unsynchronized valve actuators, valve actuators in “off” position, improper gas pipe sizing, lack of fuel, or inadequate heater vent pipe sizing, programming errors.
-
Freezing, corrosion, cracking, overheating, warping, flooding, moisture intrusion or any other condition caused by or related to weather, climate, improper winterization, improper equipment placement, inadequate ventilation, inadequate water circulation, roof run-off, sprinklers, irrigation systems, or lights or other products on or near the pool/spa or pool/spa equipment pad.
-
Operating the product at water flow rates below minimum, or above maximum, specifications. Operating any product or piece of equipment including, but not limited to, pumps, with insufficient quantities of water.
-
Dirty, clogged, blocked, covered or obstructed plumbing, chlorine generator cells or sensors, pump strainer baskets, pump impellers, heater orifices
(including blockage by spider webs), heater grills, doors, flue boxes, flue vents or flue collectors, filter elements, or filter breather tubes. -
Collateral damage caused by failure of any component including O-rings, pump strainer baskets, DE grids, sand filter laterals, or cartridge elements.
This is the only warranty given by Fluidra. No one is authorized to make any
other warranties on behalf of Fluidra. THE DURATION OF IMPLIED WARRANTIES,
INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY AND THE IMPLIED WARRANTY OF
FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO THE DURATION OF THE EXPRESS
WARRANTIES LISTED ABOVE. Some states and/or provinces do not allow limitations
on how long an implied warranty lasts, so the above limitation may not apply
to you. Fluidra expressly disclaims and excludes any liability for
consequential, incidental, indirect, or punitive damages for breach of any
expressed or implied warranty. In no event shall Fluidra be liable for
incidental or consequential damages of any nature, including damage to vinyl
liners, plaster, aggregate-based pool surfaces, tile, stone, coping, fixtures,
skimmers or skimmer covers, plumbing, drains, equipment covers or shelters,
landscaping, animals, plants, or dwellings. Some states and/or provinces do
not allow the exclusion or limitation of incidental or consequential damages,
so the above limitation may not apply
to you. Certain vinyl liner patterns are particularly susceptible to rapid
surface wear or pattern removal caused by objects coming into contact with the
vinyl surface, including pool brushes, pool toys, floats, fountains, chlorine
dispensers, and automatic pool cleaners. Some vinyl liner patterns can be
seriously scratched or abraded by rubbing the surface with a pool brush. Ink
from the pattern can also rub off during the installation process or when it
comes into contact with objects in the pool. Fluidra is not responsible for,
and this warranty does not cover, pattern removal, cuts, abrasions or markings
on vinyl liners.
This warranty gives you specific legal rights. You may also have other rights
that vary by state and/or province. For warranty consideration, contact the
original dealer and provide the following information: proof of purchase,
model number, serial number, date of retail purchase, and date of
installation. The dealer will contact the factory to obtain instructions
regarding the claim and to determine the location of the nearest independent
service company. If the dealer is not available, you can locate an independent
service company in your area by visiting www.fluidrausa.com or by emailing our
Technical Support Department at
productsupport@fluidra.com, or by calling
our Technical Support Department at
800-822-7933. All returned parts must
have a Returned Material Authorization number to be evaluated under the terms
of this warranty.
USA | 2882 Whiptail Loop # 100, Carlsbad, CA 92010 | 1.800.822.7933 |
Jandy.com Canada | 2-3365 Mainway, Burlington, ON L7M 1A6 Canada |
1.888.647.4004 | Jandy.ca
©2020 Zodiac Pool Systems LLC. All rights reserved. Jandy® is a registered
trademark of Zodiac Pool Systems LLC. All other trademarks are the property of
their respective owners. H0333803 Rev W
References
- Home | Fluidra USA
- Jandy Swimming Pool Equipment | Canada | Jandy
- Product Registration | Fluidra Canada
- Product Registration | Fluidra USA
- Home | Fluidra USA
- Home | Fluidra USA
- Zodiac Pool Systems United States | Zodiac Pool Systems
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>