PREREQUISITES FOR INSTALLATION
Product installation should be done only by a trained Eureka Forbes Service Technician only.
-
Input water must be tested for Total Dissolved Solids (TDS) and Total Hardness
– Install the product in a dry ventilated place. Keep it away from direct sunlight, heating devices or areas below 10°C.
– The purifier should be placed in area which is free of ants/insects/other pests.
– Ensure that the input tap water temperature is in the range of 10C. Avoid installation to a hot water tap as it can damage the filters. -
The input water pressure to your water purifier should be within the recommended range (refer variant specific technical specifications table). If- 40° the input water pressure is more than specified, installation of a PRV (Pressure Regulating Valve) is mandatory. If the input water pressure is less than specified, installation of an external booster pump is recommended.
-
Ensure that the filters are flushed thoroughly and independently for 3-5 minutes to remove fine particles present in the filter, before the installation of the unit.
-
After installation, run the purifier for 5-10 minutes and drain the water.
Input water quality usage limitations:
- If the input water iron content is more than that prescribed in the technical specifications, use of an iron remover** is recommended as a pretreatment.
- If the input water turbidity is more than that prescribed in the technical specifications or comprises colloidal particles, use of a special filter** is required as a pre-filter.
- If the input water TDS is more than 1,000 ppm (mg/L) or input water hardness is more than 300 ppm (mg/L), use of a Membrane life enhancer** is recommended (applicable only for RO variants).
- Do not install the water purifier if the TDS is more than that prescribed in the technical specifications.
Available at an extra cost.
THE PROCESS OF PURIFICATION (For UV Variant)**
Stage | Treatment | Materials | Benefits |
---|---|---|---|
1 | Sediment filter | Multi-layered Polypropylene spun cartridge over the carbon | |
block | Removes suspended particles such as dirt, dust, mud and sand from |
water. It removes very fine turbidity from the water
2| ChemiblockTM| Dust-free Bacteriostatic Activated Carbon block filter
cartridge as a core| Adsorbs colour, Odour, excess chlorine & organic
impurities from the incoming water. Its unique Particle Trap Filter entraps
any released micro particles.
3| Mineral Guard| Microcontroller-based electronic impulse producer| Generates
electronic impulses which prevent scaling / deposition of Calcium and
Magnesium on the Quartz Glass tube of the UV reflector chamber, thereby
ensuring best UV Penetration through Quartz Glass into the water column and at
the same time keeping essential minerals like Calcium and Magnesium intact in
water
4| UV e-boiling| Germicidal UV Lamp| UV disinfects the water by eliminating
waterborne disease-causing bacteria, viruses & protozoa, thereby making it
safe to drink.
5| Mineral Charge Cartridge| A mineral media that slowly releases essential
natural minerals (calcium and magnesium)| Removes residual organic impurities
and revives the original taste of water. Increases the level of calcium and
magnesium minerals in the purified water and balances pH of water.
TECHNICAL SPECIFICATIONS*
# | TECHNICAL PARAMETER Model | SPECIFICATION |
---|
Model AQUAGUARD® MIST NXT UV+
PRODUCT SPECIFICATION 313 mm X 167 mm X 423 mm (Approx.)
1| Dimension (W X D X H)|
2| Net weight| 3.0 kg (Approx.)
3| Purification Technology| UV
4| Standard Purification supplied| Combination cartridge (sediment + Chemi),
Mineral guardrm, UV- E-boiling, Mineral Charge Cartridge
ELECTRICAL SPECIFICATIONS
1| Power Rating| 20 Watts (Max.)
2| Power Supply| Input 230V AC, 50Hz./Output (AC/DC Adaptor) 12V DC, 1.7 A
3| UV LAMP| 11 Watts
4| UV Lamp life| 8000 burning hours (as per UV lamp manufacturer spec.)
5| Operating Voltage Range| 150 to 280 V AC, 50 Hz
RECOMMENDED INPUT WATER PARAMETERS
1| Input water pressure range**| 0.3 to 2 kg/cm2
2| Input Iron content (Max.)| 0.3 mg/L
3| Input Chlorine content (Max.)| 0.2 mg/L
4| Input water turbidity (Max.)| 5 NTU
5| Total Dissolved Solids (TDS)| Up to 200 mg/L
6| Input Water Temperature range| 10°C to 40°C
*Technical Specifications are subject to change without prior notice.
Note: The performance data presented in the table is applicable under
standard laboratory conditions Actual performance may vary depending on the
input water quality, water pressure and condition of
filters.
If the pressure is higher than the maximum specified, use of a pressure
reducing valve is mandatory, If the pressure is lower than minimum specified,
use an external booster pump recommended. The above accessories are available
with our company at an additional cost.
The purification cartridges are designed to provide safe water for a period of
1 year or 6000 liters from the date of installation whichever is earlier. Post
the safe life, for your complete protection, it is recommended to replace the
cartridges.
Warranty Void if the product is not installed as per recommendations.
Standard Test Conditions:
Feed Water Quality: TDS Max: 200 mg/L
Pressure: 1 kg/cm², Turbidity: 1 NTU (Max.), Temperature: 25°C, Chlorine:
below 0.2 mg/L, Iron: below 0.3 mg/L Life: 6000
Actual performance may vary based on input water conditions – Turbidity&
Pressure.
FUNCTION OF INDICATORS – LED DISPLAY
Sr. No| Indication of the Unit| Functions| Sr. No|
Indication of the Unit| Functions
---|---|---|---|---|---
1| | Fit the adaptor into the socket and switch ON the mains. The 3 Blue LEDs
2,3,6 will glow for
5 seconds indicating that power is ON.| 5| | If the unit is not used for a
stipulated time, it will be proceeding to a standby mode which is indicated by
a single solid LED indication. To collect water just touch the center area of
LED indication
2| | After 5 Seconds the LEDs will go OFF one by one, rotating clockwise and
will continue for 30 seconds, indicating the unit is processing| 6| All LED’s
blink with buzzer /faults| If all the LEDs blink with buzzer beeps, it
indicates SV/Pump fault/ LDR/UV lamp fault. In case of UVDR fault buzzer beeps
once eve I every 3 seconds. In case of SNIT ump fault buzzer beeps twice every
3 seconds.
3| | Once the processing is complete, all LEDs lights will become solid-fixed,
indicating the readiness to dispense water| 7| | During installation and when
the unit has not been used for 2-3 weeks, the water Side the unit has to be
flushed out. To activate flushing touch and hold the center area of the LED of
10 seconds. Flushing will start (indicated by the anti-clockwise rotation of
the LED) and stop after the stipulated time. In case you wish to stop the
flushing, retouch the center area of LED
CAUTION : DO NOT DRINK THE WATER WHICH COMES OUT OF THE FLUSHING MODE
4| | To dispense the water, touch and leave the center area of LED indication.
During dispensing, single LED rotates in Clockwise direction. To stop the
water flow, retouch & release the center area of LED indication.| Note :
Refer the LED numbers assigned for each LED to understand the indication chart
Turn OFF the main switch and the water supply if you do not plan to use the
unit for 3 — 4 hours or more.
WARRANTY TERMS & CONDITIONS*
- The Products are warranted against manufacturing defects for a period of twelve (12) months from the date of original purchase.
- The Customer will notify the Company in writing promptly of any defects noticed and give the Company or its authorized agent adequate opportunity to inspect test and remedy them for which the Customer will deposit the goods at its own expense, if so, required by the Company with the Company’s Office/Service Centre along with the original invoice in the city where they are sold.
- The Inspection and Test Report of the company’s office/service centre will be final and binding under the warranty for determining defects, repairs / alterations required or carried out or certifying work of the goods thereafter.
- AQUAGUARD may require initial setting, post-installation, depending on varying water conditions and power supply. In case of any service requirement, post-installation, please contact the company’s service centre.
- The company or its authorized agent will be entitled to retain any defective part replaced under the warranty.
- Notwithstanding anything to the contrary contained or implied by this warranty:
a) The company’s liability under this warranty shall be limited to the first sale of the goods by the company to the customer and will not apply or extend to any secondary sale of goods by the customer.
b) The company’s liability under this warranty shall be limited only to defects in the goods which occur under the conditions of normal operation of the goods and their proper and prescribed use. The warranty does not cover or extend to defects which are determined by the company or its authorized agents as occurring or resulting from or attributable to negligence, abuse, misuse, faulty care, operation or maintenance or repairs, alterations to the goods or any part thereof by others or the use of the goods on electrical supply for which they are not designed, or damage caused by lightening or other electrical disturbances or interruptions, dismantling or re-installation at a different location.
c) The company’s liability under this warranty shall remain valid only if the goods are duly installed by the company or its authorized agency at the location specified in the invoice and such installation is undertaken by the company or its authorized agent or franchisee.
d) Consumable are subject to normal wear and tear are not covered by this warranty. Please refer model specific components given in the user manual.
e) Reverse Osmosis Membrane warranty is for a period of 1 year (or) 6,000 litres (whichever is earlier) from the date of installation, on the condition that the input water is as per the standard test conditions for RO variants (provided in the section “Technical specifications table”), mentioned in the user manual. If the RO membrane gets clogged within warranty period, it will be cleaned/repaired/replaced free of charge as deemed fit by the company authorized service person/centre after inspection. (At applicable for RO models only.)
f) The customer will have no claim against the company, its employees and its authorized agents or franchisees under or pursuant to this warranty in respect of death or injury to the customer or any other person or loss or damage to any property caused by or due to equipment failure, breakdown or accident, fire or operation or utilization of the goods otherwise than in accordance with the user manual or by due to any other cause or circumstances beyond the control of the company.
g) The company’s liability, under this warranty, shall in no event and under no circumstances exceed the price paid by the customer to the company for the goods stated in the invoice.
General
For the purpose of this warranty, the following expressions shall have the
following meanings respectively:
- The ‘Goods’ shall mean the goods described in the Order Form.
- The ‘Customer’ shall mean the original purchaser of goods from the company.
- The ‘Company’ shall mean EUREKA FORBES LIMITED.
- Aquaguard means and includes AQUAGUARD, AQUAGUARD Select and Sure from AQUAGUARD.
- ‘General Terms & Conditions’ shall mean the terms and conditions agreed upon by the customer and the company printed on the Order Form.
- ‘Invoice’ shall mean the invoice issued by the company to the customer describing the goods and indicating, inter alia, the total purchase price thereof and name of the customer.
- ‘User Manual shall mean the instructions for Installation, use and maintenance provided through QR code along with Product supplied by the company.
- EFL reserves the right, in its absolute discretion, to change, alter or discontinue and alter the terms and conditions from time to time without any prior notice.
- Any disputes are subject to Mumbai Jurisdiction only.
Post-warranty
- The customer may be offered a yearly Service Contract at the prevailing company rates and terms.
- In case the customer does not wish to enter the Service Contract, he has the option of calling the company’s service centre having his AQUAGUARD® services on an actual basis, i.e., by paying the labour cost and spares needed to attend to that service/complaint call at the prevailing company rates. Such service will be rendered by the company in towns/places where the company has its service centres.
- If during such servicing it is necessary for the company to replace or repair defective components or parts, the customer shall be required to pay for the same as per the company’s prevailing price list.
- Eureka Forbes limited reserves the right to offer annual maintenance contract/ensure availability of spares only up to 7 years from the date of invoice. *Conditions apply.
ENVIRONMENT PROTECTION:
“Protection” has always been our motto and guiding principle. We care for the
environment. We urge you to recycle the packaging material or take it to the
nearest recycling facility rather than dispose it off with the rest of your
waste. Your product has been designed to work for many years, however, should
you wish to upgrade or replace your old product, remember to help protect the
environment by disposing it off at your local e-waste disposal center. Should
you have any queries, the nearest authorized service center of Eureka Forbes
will be able to guide you. Allow us to become your environment partner;
together we can make the world a cleaner place.
HEALTH PROTECTTM
For your safety the specially designed and electronically authenticated
purification cartridges of Aqua guard ensure our promise of ‘pure & healthy
water always. In the unlikely usage of a ‘non-genuine’ purification cartridge
that could potentially deliver unsafe water – an indication will draw your
attention. For your complete protection, it does not initiate the purification
process. The purification cartridges are designed to provide safe water for a
period of 1 year or 6000 liters from the date of installation whichever is
earlier. Post the safe life, for your complete protection, it is recommended
to replace the cartridges.
Refer – Standard Test Conditions. Depending on the input water quality
(variations in the standard test conditions) the filter might need a
replacement even before 1 year or 6000 L of purified water.
18602661177
SMS ‘
Now buy online in www.eurekaforbes.com
www.facebook.com/EurekaForbes
[
** Email:
deepa.customercare@eurekaforbes.com
Eureka Forbes Limited:**
B1/B2, 701, 7th Floor, Marathon Innova Marathon NexGen,
Off Ganatra Kadam Marg, Lower Parle, Mumbai – 400 013, India.
Tel: +91 22 4882 1700, 62601888
Fax: +91 22 4882 1701
Read User Manual Online (PDF format)