Schreder BRITELINE GEN2 2 External Version Versatile and Efficient Lighting Instruction Manual

June 13, 2024
Schreder

Schreder Logo BRITELINE
GEN2 2
External version

BRITELINE GEN2 2 External Version Versatile and Efficient Lighting

Schreder BRITELINE GEN2 2 External Version Versatile and Efficient
Lighting INSTALLATION INSTRUCTIONSSchreder BRITELINE GEN2 2 External Version Versatile and
Efficient Lighting - Icon

![Schreder BRITELINE GEN2 2 External Version Versatile and Efficient Lighting

WEAR PROTECTIVE GLOVES

PRODUCT OVERVIEW

![Schreder BRITELINE GEN2 2 External Version Versatile and Efficient Lighting

BRITELINE GEN2 2 EXTERNAL GEAR BOX
A B

679mm
26.73in| 367mm
14.44in| 723mm
28.46in| 30kg
6613lbs| 426mm
16.77in| 384mm
15.11in| 283mm
11.14in| 243mm
9.56in| 110mm
4.33in| 10kg
22.04lbs

EPA – Effective Projected Area

![Schreder BRITELINE GEN2 2 External Version Versatile and Efficient Lighting

| a = 0°| a = 30°| a = 45°| a = 70°| a = 90°
---|---|---|---|---|---
S(m2)| CxS (m2)| EPA (ft2)| S(m2)| CxS (m2)| EPA (ft2)| S(m2)| CxS (m2)| EPA (ft2)| S(m2)| CxS (m2)| EPA (ft2)| S(m2)| CxS (m2)| EPA (ft2)
Si| 0.0633| 0.08| 0.82| 1718| 0.21| 2.| 0.2253| 0.28| 3.| 0.2815| 0.34| 4.| 0.2915| 0.35| 4.
S2| 0.2915| 0.35| 377| 0.2764| 0.34| 4.| 0.2428| 0.3| 3.| 0.1530| 19| 2.| 0.0633| 0.08| 0.82
S3| 0.0625| 0.08| 0.81| 0.0625| 0.08| 0.81| 0.0625| 0.08| 0.81| 0.0625| 0.08| 0.81| 0.0625| 0.08| 0.81

MOUNTING

![Schreder BRITELINE GEN2 2 External Version Versatile and Efficient Lighting

Minimum screw requirement:

Vibration standard IEC 0.5g / ANSI 1.5g
Minimum fastener requirement 1x M20 8.8 or A2-70 DIN9021 large plain washer
Tightening torques 1xM20: 200 Nm 2xM20: 140 Nm

Recommended to use anti-seizing agent (Tikal Tef-Gel®) !Schreder
BRITELINE GEN2 2 External Version Versatile and Efficient Lighting - Icon
4

  1. 1xM20 with extra large washer
    or

  2. 2xM20 with extra large washer

Mounting dimensions

D1 D2 D3 D4 D5 D6

min 250mm
min 9.84in| 70mm
2.75in| 150mm
5.9in| 320mm
12,6in| 460mm
15.98in| 22mm
0.86in

![Schreder BRITELINE GEN2 2 External Version Versatile and Efficient Lighting

Minimum Surface Contact Area for screw fixation 124mm/4.88inSchreder
BRITELINE GEN2 2 External Version Versatile and Efficient Lighting -
dimensions 2 Fasteners are not included in the package!
Remark: the hatched area always need to be supported by a flat planar mounting surface as minimum.
Wider surface contact is recommended, smaller is not allowed!

ANGLE ADJUSTMENT

C/1 – BRACKET TO FORK

  1. Loosen the clamp screwsSchreder BRITELINE GEN2 2 External Version Versatile and Efficient Lighting - BRACKET

  2. Adjust tilting angleSchreder BRITELINE GEN2 2 External Version Versatile and Efficient Lighting - BRACKET 1Separate scale for adjusting the distance of the optical 50mm block from the luminaire holder
    The swing arm inclination is adjustable in 10 degree increments relative to fork base.
    ALLOWED tilt angle is between -10° to 90°

  3. Tighten the clamp screwsSchreder BRITELINE GEN2 2 External Version Versatile and Efficient Lighting - Tighten Do not exceed the proposed torque levels, as it may result in fraction of the parts!

C/2 – OPTICAL BLOCKS TO BRACKET

  1. Loosen the clamp screwsSchreder BRITELINE GEN2 2 External Version Versatile and Efficient Lighting - Tighten 1
  2. Adjust tilting angleSchreder BRITELINE GEN2 2 External Version Versatile and Efficient Lighting - tilting ALLOWED tilt angle is between -30° to +30°
  3. Tighten the clamp screwsSchreder BRITELINE GEN2 2 External Version Versatile and Efficient Lighting - tilting 1 Do not exceed the proposed torque levels, as it may result in fraction of the parts!

ALLOWED POSITIONING

![Schreder BRITELINE GEN2 2 External Version Versatile and Efficient Lighting

GEAR INSTALLATION

![Schreder BRITELINE GEN2 2 External Version Versatile and Efficient Lighting

SAFETY CABLE

![Schreder BRITELINE GEN2 2 External Version Versatile and Efficient Lighting

Steel safety cable should pass through the holes shown in the drawing in sequence.
Then connect the two ends with the lock buckle and tighten the lock bolt by hand.
For installations over 3m height: secondary safety system application is mandatory, which is appropriated for the luminaire load (e.g. safety cable)”
2500mm/98.42in safety cable is supplied with the luminaire.

ELECTRICAL CONNECTION

  1. Remove the R-type buckles from the junction box and gear box .

  2. Open junction box and gear boxSchreder BRITELINE GEN2 2 External Version Versatile and Efficient Lighting - compatibility
    Cable ID| Connection| Cable gland| Suitable cable
    ---|---|---|---
    A| Mains input| M20| 06-10mm or 010-14mm
    B| Mains re-launch
    C| DC output to optical block| M25/cable protection compatibility| 06-10mm or 010-14mm
    D| Dimming input| M16| 04.5-7.5mm or 07.5-10.5mm
    E| Dimming re-launch

  3. Cable types and cable gland
    When using a larger external diameter cable, the plug and the smaller inner diameter seal need to be removed.
    When using a smaller external diameter cable, simply remove the plug.Schreder BRITELINE GEN2 2 External Version Versatile and Efficient
Lighting - compatibility 1

  4. Make electrical connection Wiring should strictly follow the marking label instruction, otherwise the product could be damaged or the functions could be affected!Schreder BRITELINE GEN2 2 External Version Versatile and Efficient Lighting - electrical AC and CONTROL cables must be connected by the installer!
    Connection| Cable gland| Recommended cable type
    ---|---|---
    Control signal| PG16(Ø5-Ø7.5/Ø7.5-Ø10)| H05RN-F, 2 x 1-1.5mm
      AC INPUT| PG20(Ø6-Ø10/Ø10-Ø14)| H07RN-F, 3 x 1.5-4mm
    DC OUTPUT| PG20(Ø6-Ø10/Ø10-Ø14)| H05RN-F, 5 x 1.0mm²
    H07RN-F, 5 x 1.5mm²

  5. Close junction box and gear boxSchreder BRITELINE GEN2 2 External Version Versatile and Efficient Lighting - CONTROLClose the cover of the junction box and gear box, and put the R-type buckles back on both.
    1.5m metal tube and DC cable provided for junction box – gearbox connection.

RECOMMENDATIONS

  1. Surrounding distances At least 1 meter distance should be kept from surrounding walls, floor, and ceiling for all types of mounting/inclination.
  2. Maximum number of luminaires per MCB
Product Driver MCB B type
B10 B13 B16
BRITELINE GEN2 2 @220V EUM-680MG/BG 0
BRITELINE GEN2 2 ©480V ESM-680MG/BG 1
Product Driver MCB C type
C10 13 16
BRITELINE GEN2 2 ©220V EUM-680MG/BG 0
BRITELINE GEN2 2 @480V ESM-680MG/BG 1

AIMING DEVICE

![Schreder BRITELINE GEN2 2 External Version Versatile and Efficient Lighting

The small blocks on the side of the optical block assure the installation of the built-in aiming devide.
The external aiming device position 1 needs to be aligned with positions 2 and 3.

ACCESSORIES – HOOD

![Schreder BRITELINE GEN2 2 External Version Versatile and Efficient Lighting

SAFETY INSTRUCTIONS

The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person. Always switch off the power prior to installation, maintenance or repair activities.
RISK GROUP 2 –
CAUTION! Hazardous optical radiation may be emitted from this product. Do not stare at the luminaire when operating as it may be harmful to the eyes. The luminaire should be positioned so that prolonged staring at the luminaire at a  istance of less than 0.2m is not expected.
This product contains a light source of an energy efficiency class G or higher.
In case of PVC insulated mains cable, the installer MUST ensure that the WHOLE cable is protected against climatic conditions, especially UV rays and rain, by making sure that the cable is  contained inside the luminaire and pole.
Y-connection: In case of  amage to the wire, it has to be replaced only by the manufacturer, distributor or by an expert, to avoid risks. Risk Group
IEC/EN 62471 Photobiological Safety
Assessment based on IEC/TR 62778, CmaxSchreder BRITELINE GEN2 2 External
Version Versatile and Efficient Lighting - Icon 6

Schreder LogoCopyright © Schréder S.A. 2023 – Executive Publisher: Stéphane Halleux – B-4000 Liége, Rue de Mons 3 (Belgium)
The information, descriptions and illustrations herein are only of an indicative nature and subject to changes without notice
www.schreder.com
Rev C | 08-2023

Documents / Resources

| Schreder BRITELINE GEN2 2 External Version Versatile and Efficient Lighting [pdf] Instruction Manual
BRITELINE GEN2 2 External Version Versatile and Efficient Lighting, BRITELINE GEN2 2, External Version Versatile and Efficient Lighting, Version Versatile and Efficient Lighting, Efficient Lighting, Lighting
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Schreder User Manuals

Related Manuals