interlogix NX-4 NetworX 4 Zone Control Panel User Guide
- June 9, 2024
- interlogix
Table of Contents
interlogix NX-4 NetworX 4 Zone Control Panel
Changing and Adding User Codes
NX-4, NX-6, or NX-8
System must be disarmed to change user codes
Step 1 – Press *5 and the Master Code (main user code).
Step 2 – The ready light will flash.
Step 3 – Enter the 2 digit “user number” (example: 01 for user #1 if
changing Master Code.)
Step 4 – Enter the new 4 digit user code.
Step 5 – Press the # key while the ready light is flashing to exit the
User Code Programming Mode.
To delete a user code enter for a 4 digit code after step 3.
Do NOT delete user 1**
NX-8E
System must be disarmed to change user codes
Step 1 – Press *5 and the Master Code (main user code).
Step 2 – The ready light will flash.
Step 3 – Enter 3 digit user number Ex. 001 for user # 1 if changing
master code
Step 4 – Enter the new 4 digit user code.
Step 5 – Press the # key while the ready light is flashing to exit the
User Code Programming Mode.
To Delete a user code enter for a 4 digit code after step 3.
Do NOT delete user 1**
Activating the Chime Mode:
The door chime is turned on or off by pressing the CHIME key while the system is in the disarmed state. If the chime is on the CHIME light will be on. If the chime is off the CHIME light will be off.
Resetting Smoke Detectors
To reset smoke detectors press *7
Bypassing Zones
To bypass a zone press the Bypass key then the zone number then the Bypass key twice
Reset Battery
Arm and then disarm system.
Review User Codes from the Keypad
Press [*] [5] [master code] Enter user # (3 digit # for NX-8E) Press the down arrow (press the arrow 4 times to see all 4 digits of the user code) and the zone LED’s will light up. The zone # that is lit indicates the digit of the code (for 9 zones 1 & 8 will be lit).
Flashing power light means low battery.
Identifying Service or Trouble Conditions
The service light will be on if the security system requires service. If the service light is on press the * key followed by the 2 key to determine the service condition. One or more zone lights will light up indicating what service is required.
Zone | Problem |
---|---|
*1 | System Fault – Press the 1 key. The zone light that is lit corresponds to the system faults below: 1 – Overcurrent 5 – Expander Low Battery 2 – Siren Trouble 6 – Expander Box Tamper 3 – Box Tamper 7 – Expander Trouble 4 – Expander Power 8 – Ground Fault |
*2 | Zone Tamper – Press the 2 key and the zone light will light up showing the zones that are tampered. |
*3 | Zone Low Battery – Press the 3 key. The zone light will light up showing which zone has a low battery. This only applies to wireless zones. |
*4 | Zone Loss of Supervision – Press the 4 key and the zone lights will light up showing which zone has loss of supervision. This only applies to wireless zones. |
*5 | Zone Trouble – Press the 5 key and the zone will light up showing which zone has a trouble condition. |
6 | Telephone Line Trouble/Line Cut – The service light will remain lit until |
the trouble clears and a user code is entered.
7| Failure To Communicate – This light will light up when there is a failure
to communicate between your system and the control station. To clear a
successful signal most be received at Central Station.
8| Loss of System Time – This light will light up when there has been a loss
of power and your system clock needs to be reset.
Indicates that if one of these trouble conditions comes up then you must
press the number to check exact trouble.
Example: You press 2 and zone 4 is lit, press 4 to see which specific zone
number has loss of supervision.