Schreder OMNIBOX XL Energy Efficient Solution for Industrial Installation Guide

June 1, 2024
Schreder

Schreder OMNIBOX XL Energy Efficient Solution for Industrial

 Schreder OMNIBOX XL Energy Efficient Solution for Industrial

Features

Features

Tools

Tools

Dimension

| L
mm/in| B
mm/in| B1
mm/in| H
mm/in| H1
mm/in
---|---|---|---|---|---
OMNIBOX XL1| 530/21| 415/16| 455/18| 180/7| 150/6
OMNIBOX XL 2| 610/24| 415/16| 455/18| 180/7| 150/6
OMNIBOX XL 3| 690/27| 415/16| 455/18| 180/7| 150/6
OMNIBOX XL 4| 810/32| 415/16| 455/18| 180/7| 150/6
OMNIBOX XL 5| 870/34| 415/16| 455/18| 180/7| 150/6
OMNIBOX XL 6| 910/36| 415/16| 455/18| 180/7| 150/6
OMNIBOX XL 7| 1010/40| 415/16| 455/18| 180/7| 150/6
OMNIBOX XL 8| 1070/42| 415/16| 455/18| 180/7| 150/6

Dimension

| kg/lb
---|---
OMNIBOX XL 1| 15/33
OMNIBOX XL 2| 17/37
OMNIBOX XL 3| 20/44
OMNIBOX XL 4| 23/51
OMNIBOX XL 5| 26/59
OMNIBOX XL 6| 29/63
OMNIBOX XL 7| 32/70
OMNIBOX XL 8| 35/77

Dimension

FIXED BRACKETS ANSI 3G

Fixed Brackets Ansi 3g

Fixed Brackets Ansi 3g

Caution: distance between brackets can vary depends on profile size of OMNIBOX XL

Fixed Brackets Ansi 3g

| mm/in
---|---
OMNIBOX XL 1| 280/11
OMNIBOX XL 2| 300/12
OMNIBOX XL 3| 380/14
OMNIBOX XL 4| 500/19
OMNIBOX XL 5| 560/22
OMNIBOX XL 6| 660/26
OMNIBOX XL 7| 700/28
OMNIBOX XL 8| 760/30

Fixed Brackets Ansi 3g

| mm/in
---|---
OMNIBOX XL 1| 80/3
OMNIBOX XL 2| –
OMNIBOX XL 3| 190/7
OMNIBOX XL 4| –
OMNIBOX XL 5| 360/14
OMNIBOX XL 6| 600/24
OMNIBOX XL 7| –
OMNIBOX XL 8| –

Fixed Brackets Ansi 3g

Mounting Configurations

Mounting Configurations

Opening

Opening

Opening

INPUT CONNECTION

Symbols

Mains and Controls separated

QPD CONNECTORS

Lumgate

  1. Main QPD 4P (M25)
  2. M17 (BUS IN – Male)
  3. M17 (Bus OUT – Female)

Input Connection

  1. 1-10V/DALI
  2. Main QPD 4P (M25)
  3. QPD 2P (M20)
    Input Connection

Mains and Controls combined

Mains and Controls combined

CABLE GLANDS

Symbols

Mains and Controls combined

Lumgate

  1. M25 cable gland
  2. M17 (BUS IN – Male)
  3. M17 (Bus OUT – Female)

Mains and Controls separated

1 Mains supply
23 Controls

1-10V/DALI

  1. M25 cable gland
  2. M20 cable gland

1 Mains supply
2 Controls

Mains and Controls separated

Symbols

Mains and Controls combined

1-10V/DALI
No Dim

1 M25 cable gland Mains supply and Controls

Mains and Controls combined

 WEAR PROTECTIVE GLOVES

Mains Supply Controls signal
Lumgate

1-10V / DALI
Mains and Controls combined
3×2.5mm²
3×1.5mm²| 2×1.5mm²
2×2.5mm²
Mains and Controls combined

1-10V /DALI| No Dim
Mains and Controls combined
5×2.5mm²
5×1.5mm²| 3×2.5mm²
3×1.5mm²
*(possible with (X) x 4mm² as terminals are 4mm²).
Mains Supply| Controls signal
---|---
Lumgate|
1-10V /DALI
Mains and Controls combined
2×2.5mm²
2×1.5mm²| 2×1.5mm²
2×2.5mm²
Mains and Controls combined

1-10V /DAL| No Dim
Mains and Controls combined
M25 Ø9-14mm| M25 Ø6-12mm
*(possible with (X) x 4mm² as terminals are 4mm²).

OUTPUT CONNECTION

Symbols

Standard cable – 3 or 5 cores (Wieland M20)

External cables

To OMNIBOX XL

3P CONNECTOR

CONNECTOR PIN#| Circuit 1 Optical units
1 (+)
2 (-)
3| Earth


To Optical block

5P CONNECTOR

CONNECTOR PIN#| Circuit 1
Optical units
1 (+)
2 (-)
3 (+)| Circuit 2
Optical units
4 (-)
5| Earth

Output Connection

Cable Gland

Cable Gland

SAFETY INSTRUCTIONS

The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person. Always switch off the power prior to installation, maintenance or repair activities.

RISK GROUP 2

CAUTION! Hazardous optical radiation may be emitted from this product. Do not stare at the luminaire when operating as it may be harmful to the eyes. The luminaire should be positioned so that prolonged staring at the luminaire at a distance of less than 0.94m is not expected.

ENERGY EFFICIENCY

This product contains a light source of an energy efficiency class G or higher or see table on first page.

PVC INSULATION AND Y CONNECTION

In case of PVC insulated mains cable, the installer MUST ensure that the WHOLE cable is protected against climatic conditions, especially UV rays and rain, by making sure that the cable is contained inside the luminaire and pole. Y-connection: In case of damage to the wire, it has to be replaced only by the manufacturer, distributor or by an expert, to avoid risks

Pvc Insulation And Y Connection