Schreder OMNIBOX XL Energy Efficient Solution for Industrial
Features
Tools
Dimension
| L
mm/in| B
mm/in| B1
mm/in| H
mm/in| H1
mm/in
---|---|---|---|---|---
OMNIBOX XL1| 530/21| 415/16| 455/18| 180/7| 150/6
OMNIBOX XL 2| 610/24| 415/16| 455/18| 180/7| 150/6
OMNIBOX XL 3| 690/27| 415/16| 455/18| 180/7| 150/6
OMNIBOX XL 4| 810/32| 415/16| 455/18| 180/7| 150/6
OMNIBOX XL 5| 870/34| 415/16| 455/18| 180/7| 150/6
OMNIBOX XL 6| 910/36| 415/16| 455/18| 180/7| 150/6
OMNIBOX XL 7| 1010/40| 415/16| 455/18| 180/7| 150/6
OMNIBOX XL 8| 1070/42| 415/16| 455/18| 180/7| 150/6
| kg/lb
---|---
OMNIBOX XL 1| 15/33
OMNIBOX XL 2| 17/37
OMNIBOX XL 3| 20/44
OMNIBOX XL 4| 23/51
OMNIBOX XL 5| 26/59
OMNIBOX XL 6| 29/63
OMNIBOX XL 7| 32/70
OMNIBOX XL 8| 35/77
FIXED BRACKETS ANSI 3G
Caution: distance between brackets can vary depends on profile size of OMNIBOX XL
| mm/in
---|---
OMNIBOX XL 1| 280/11
OMNIBOX XL 2| 300/12
OMNIBOX XL 3| 380/14
OMNIBOX XL 4| 500/19
OMNIBOX XL 5| 560/22
OMNIBOX XL 6| 660/26
OMNIBOX XL 7| 700/28
OMNIBOX XL 8| 760/30
| mm/in
---|---
OMNIBOX XL 1| 80/3
OMNIBOX XL 2| –
OMNIBOX XL 3| 190/7
OMNIBOX XL 4| –
OMNIBOX XL 5| 360/14
OMNIBOX XL 6| 600/24
OMNIBOX XL 7| –
OMNIBOX XL 8| –
Mounting Configurations
Opening
INPUT CONNECTION
Mains and Controls separated
QPD CONNECTORS
Lumgate
- Main QPD 4P (M25)
- M17 (BUS IN – Male)
- M17 (Bus OUT – Female)
- 1-10V/DALI
- Main QPD 4P (M25)
- QPD 2P (M20)
Mains and Controls combined
CABLE GLANDS
Mains and Controls combined
Lumgate
- M25 cable gland
- M17 (BUS IN – Male)
- M17 (Bus OUT – Female)
1 Mains supply
23 Controls
1-10V/DALI
- M25 cable gland
- M20 cable gland
1 Mains supply
2 Controls
Mains and Controls combined
1-10V/DALI
No Dim
1 M25 cable gland Mains supply and Controls
WEAR PROTECTIVE GLOVES
Mains Supply | Controls signal |
---|---|
Lumgate |
1-10V / DALI
3×2.5mm²
3×1.5mm²| 2×1.5mm²
2×2.5mm²
Mains and Controls combined
1-10V /DALI| No Dim
5×2.5mm²
5×1.5mm²| 3×2.5mm²
3×1.5mm²
*(possible with (X) x 4mm² as terminals are 4mm²).
Mains Supply| Controls signal
---|---
Lumgate|
1-10V /DALI
2×2.5mm²
2×1.5mm²| 2×1.5mm²
2×2.5mm²
Mains and Controls combined
1-10V /DAL| No Dim
M25 Ø9-14mm| M25 Ø6-12mm
*(possible with (X) x 4mm² as terminals are 4mm²).
OUTPUT CONNECTION
Standard cable – 3 or 5 cores (Wieland M20)
To OMNIBOX XL
3P CONNECTOR
CONNECTOR PIN#| Circuit 1 Optical units
1 (+)
2 (-)
3| Earth
To Optical block
5P CONNECTOR
CONNECTOR PIN#| Circuit 1
Optical units
1 (+)
2 (-)
3 (+)| Circuit 2
Optical units
4 (-)
5| Earth
Cable Gland
SAFETY INSTRUCTIONS
The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person. Always switch off the power prior to installation, maintenance or repair activities.
RISK GROUP 2
CAUTION! Hazardous optical radiation may be emitted from this product. Do not stare at the luminaire when operating as it may be harmful to the eyes. The luminaire should be positioned so that prolonged staring at the luminaire at a distance of less than 0.94m is not expected.
ENERGY EFFICIENCY
This product contains a light source of an energy efficiency class G or higher or see table on first page.
PVC INSULATION AND Y CONNECTION
In case of PVC insulated mains cable, the installer MUST ensure that the WHOLE cable is protected against climatic conditions, especially UV rays and rain, by making sure that the cable is contained inside the luminaire and pole. Y-connection: In case of damage to the wire, it has to be replaced only by the manufacturer, distributor or by an expert, to avoid risks