AMPROBE LP10B Logic Probes User Manual
- June 13, 2024
- AMPROBE
Table of Contents
LP10B LP25B
Logic Probes
User Manual
LP10B Logic Probes
PN 1566429
All rights reserved. Printed in Taiwan
Limited Warranty and Limitation of Liability
Your Amprobe product will be free from defects in material and workmanship for
1 year from the date of purchase. This warranty does not cover fuses,
disposable batteries or damage from accident, neglect, misuse, alteration,
contamination, or abnormal conditions of operation or handling.
Resellers are not authorized to extend any other warranty on Amprobe’s behalf.
To obtain service during the warranty period, return the product with proof of
purchase to an authorized Amprobe Test Tools Service Center or to an Amprobe
dealer or distributor. See Repair Section for details.
THIS WARRANTY IS YOUR ONLY REMEDY. ALL OTHER WARRANTIES – WHETHER EXPRESS,
IMPLIED OR STAUTORY – INCLUDING IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR
PURPOSE OR MERCHANTABILITY, ARE HEREBY DISCLAIMED. MANUFACTURER SHALL NOT BE
LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR
LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do
not allow the exclusion or limitation of an implied warranty or of incidental
or consequential damages, this limitation of liability may not apply to you.
Symbols
| Battery| | Refer to the manual| | Double insulated
---|---|---|---|---|---
| Earth ground| ****| Complies with EU directives| | Audible tone
| Conforms to relevant Australian standards
Certifications and Precautions
This instrument is EMC/EMI certified. All inputs are protected against
continuous overload conditions up to the limits of each function’s stated
input protection (see specifications).
Never exceed these limits or the ratings marked on the instrument itself.
Always inspect your Logic Probe, test leads and accessories for signs of
damage or abnormality before every use. If an abnormal condition exists
(broken or damaged test leads, cracked case, display not reading, etc.), do
not use. Never ground yourself when taking measurements. Do not touch exposed
metal pipes, outlets, fixtures, etc., which might be at ground potential. Keep
your body isolated from ground and never touch exposed wiring, connections,
test probe tips, or any live circuit conductors. Do not operate instrument in
an explosive atmosphere (flammable gases, fumes, vapor, dust.) Do not use this
or any piece of test equipment without proper training.
CAUTION: To avoid damaging the instrument, do not use it in a place where
ambient temperature exceeds 40°C.
CAUTION: To avoid damaging the instrument, do not input more than 40 VAC
or VDC.
Preparation For Use – Unpacking
Your shipping carton should include the Logic Probe with 0.5 meter long cable with a mini-alligator clip for the ground connection and a mini-grabber for the Vcc connection and this manual. If any of the items are damaged or missing, immediately return the complete package to the place of purchase for an exchange.
Introduction
The LP10B and LP25B Logic Probes are logic troubleshooting instruments that give visual (LED’s) and audio indications (LP25B only) of logic levels and pulses. They will also capture positive or negative events as short as 30 nanoseconds. The probe is powered by the circuit under test.
Control Descriptions
TTL/CMOS – set for logic family of the circuit under test.
PULSE/MEM
PULSE – normal operation mode for pulse or level detection.
MEM – pulse capture or memory.
Operation
Setup
Connect the black alligator clip to ground or common of the circuit under
test. Connect the red mini-hook clip to Vcc of the circuit under test.
Select TTL or CMOS with the TTL/CMOS switch depending upon the type of logic
being tested. TTL level is nominal 0 to 5 VDC and CMOS levels are 0 to 5 – 15
VDC. The PULSE/MEM switch should be in PULSE for Pulse or Logic level testing.
Using the Logic Probe
Touch the LP10B or LP25B probe tip to the circuit point under test. The probes
LED’s indicate the logic level or signals present when the circuit node is
probed. The LED’s response is noted on pages 7 and 8.
Maintenance
If there appears to be a malfunction during the operation of the Logic Probe, the following steps should be performed in order to isolate the cause of the problem:
- Review the operating instructions for possible mistakes in operating procedure.
- Inspect and test the Test Cables for a broken or intermittent connection.
Any repair of the Logic Probe should be performed only by a Factory Authorized Service Center or by other qualified instrument service personnel. The probe case can be cleaned with a mild solution of detergent and water. Apply sparingly with a soft cloth and allow the Logic Probe to dry completely before using. Do not use aromatic hydrocarbons or chlorinated solvents for cleaning.
Repair
All test tools returned for warranty or non-warranty repair or for calibration
should be accompanied by the following: your name, company’s name, address,
telephone number, and proof of purchase. Additionally, please include a brief
description of the problem or the service requested and include the test leads
with the meter. Non-warranty repair or replacement charges should be remitted
in the form of a check, a money order, credit card with expiration date, or a
purchase order made payable to Amprobe® Test Tools.
In-Warranty Repairs and Replacement – All Countries
Please read the warranty statement and check your battery before requesting
repair. During the warranty period any defective test tool can be returned to
your Amprobe® Test Tools distributor for an exchange for the same or like
product. Please check the “Where to Buy” section on
www.amprobe.com for a list of distributors near you.
Additionally, in the United States and Canada In-Warranty repair and
replacement units can also be sent to a Amprobe® Test Tools Service Center
(see next page for address).
Non-Warranty Repairs and Replacement – US and Canada
Non-warranty repairs in the United States and Canada should be sent to a
Amprobe® Test Tools Service Center. Call Amprobe® Test Tools or inquire at
your point of purchase for current repair and replacement rates.
In USA
Amprobe Test Tools
Everett, WA 98203
Tel: 877-AMPROBE (267-7623)
Fax: 425-446-6390| In Canada
Amprobe Test Tools
Mississauga, ON L4Z 1X9
Tel: 905-890-7600
Fax: 905-890-6866
---|---
Non-Warranty Repairs and Replacement – Europe
European non-warranty units can be replaced by your Amprobe® Test Tools
distributor for a nominal charge.
Please check the “Where to Buy” section on
www.amprobe.com for a list of distributors near you.
European Correspondence Address
Amprobe® Test Tools Europe
In den Engematten 14
79286 Glottertal, Germany
Tel.: +49 (0) 7684 8009 – 0
(Correspondence only – no repair or replacement available from this address. European customers please contact your distributor.)
Specifications
Input signal | Levels | LED’s | BEEPER(LP25B) |
---|---|---|---|
Logic “1” | TTL: > 2.3 V ± 0.2 VDC | ||
CMOS: >70 % Vcc ± 10% | HI (Red) ON | ||
HI (Red) ON | Fixed Tone | ||
Logic “0” | TTL: < 0.8 V ± 0.2 VDC | ||
CMOS: <30 % Vcc ± 10% | LO (Green) ON | ||
LO (Green) ON | Fixed Tone | ||
Bad Logic Level or Open circuit | none | No Tone | |
Input signal | Levels | LED’s | BEEPER(LP25B) |
--- | --- | --- | --- |
Square Wave | < 200 Hz | HI and LO blinking at frequency rate | Variable Tone at |
frequency rate
Square Wave| > 200 Hz| HI and LO may ormay not be ON| Variable Tone at
frequency rate
Narrow Hi Pulse
Low with POS pulse
| | LO (Green) blinking intensity depends on| Variable Tone at frequency rate
Narrow Lo Pulse High with NEG pulse| | pulse duty cycle HI (Red) blinking
intensity depends on pulse duty cycle| Variable Tone at frequency rate
Electrical Specifications:
| LP10B| LP25B
---|---|---
Power Supply| 5 – 15 VDC| 5 – 15 VDC
Power Supply Current @ 5V| 30 mA| 40 mA
@ 15 V| 80 mA| 90 mA
Power Supply Protection| 20 VAC/VDC| 20 VAC/VDC
Maximum Input voltage
(15 seconds)| 40 VAC/VDC| 40 VAC/VDC
Size| 210(8.2) x 18(0.7) x 18(0.7) mm (in.)|
Weight| 38.1(1.3)| 42.6(1.5) gm(oz)
TTL/CMOS selectable| yes| yes
Maximum Input Signal Frequency| 20 MHz| 20 MHz
Minimum Detectable Pulse Width
Frequency | 1 kHz | 1 to 20 kHz | 20 kHz to 20 MHz |
---|---|---|---|
Minimum Pulse width | 100 ns | 50 ns | 30ns |
Pulse amplitude + 3 V
| LP10B| LP25B
---|---|---
Input Impedance| 1 MΩ| 1 MΩ
Pulse Indicator Flash Time| 500 mS| 500 mS
Audible tone at pulse rate| no| yes
Operating Temperature| 0 °C to 50 °C at 80 % R.H.
Storage Temperature| -20 °C to 65 °C at 75 % R.H.
Safety: This instrument is intended for use below the Low Voltage
Directive, thus is considered exempt from EN61010-1:12001.
EMC: This product complies with requirements of the following European
Community Directives: 89/336/EEC (Electromagnetic Compatibility) and 73/23/EEC
(Low Voltage) as amended by 93/68/EEC (CE Marking).
However, electrical noise or intense electromagnetic fields in the vicinity of
the equipment may disturb the measurement circuit. Measuring instruments will
also respond to unwanted signals that may be present within the measurement
circuit. Users should exercise care and take appropriate precautions to avoid
misleading results when making measurements in the presence of electronic
interference.
Visit www.Amprobe.com for
- Catalog
- Application notes
- Product specifications
- User manuals
****Please Recycle