BEHA-AMPROBE 2100-ACCS PROBE Test Probe Extender Kit User Manual

June 4, 2024
BEHA AMPROBE

2100-ACCS PROBE Test Probe Extender Kit
User Manual 2100-ACCS PROBE Test Probe Extender Kit

Limited Warranty and Limitation of Liability

Your Beha-Amprobe product will be free from defects in material and workmanship for two years from the date of purchase unless local laws require otherwise. This warranty does not cover fuses, disposable batteries or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on the behalf of Beha-Amprobe.
To obtain service during the warranty period, return the product with proof of purchase to an authorized Beha-Amprobe Service Center or to a Beha-Amprobe dealer or distributor. See Repair Section for details.
THIS WARRANTY IS YOUR ONLY REMEDY. ALL OTHER WARRANTIES – WHETHER EXPRESS, IMPLIED, OR STATUTORY – INCLUDING IMPLIED  WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, ARE HEREBY DISCLAIMED. MANUFACTURER SHALL NOT BE  LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you.

Repair
All Beha-Amprobe tools returned for warranty or non-warranty repair or for the calibration should be accompanied by the following: your name, company’s name, address,  telephone number, and proof of purchase.
Additionally, please include a brief description of the problem or the service requested and include the test leads with the meter. Non-warranty repair or replacement charges should be remitted in the form of a check, a money order, a credit card with an expiration date, or a purchase order made payable to Beha-Amprobe.
In-warranty Repairs and Replacement – All Countries
Please read the warranty statement and check your battery before requesting repair. During the warranty period, any defective test tool can be returned to your Beha-Amprobe distributor for an exchange for the same or like the product. Please check the “Where to Buy” section on beha-amprobe.com for a list of distributors near you. Additionally, in the United States and
Canada, in-warranty repair and replacement units can also be sent to an
Amprobe Service Center (see address below).
Non-warranty Repairs and Replacement – Europe
European non-warranty units can be replaced by your Beha-Amprobe distributor for a nominal charge. Please check the “Where to Buy” section on beha- amprobe.com for a list of distributors near you.
Beha-Amprobe
Division and reg. trademark of Fluke Corp. (USA)

**Germany*
In den Engematten 14
79286 Glottertal
Germany
Phone: +49 (0) 7684 8009 – 0
beha-amprobe.de|
United Kingdom
52 Hurricane Way
Norwich, Norfolk
NR6 6JB United Kingdom
Phone: +44 (0) 1603 25 6662
beha-amprobe.com|
Fluke Europe B.V.**
PO Box 1186
5602 BD Eindhoven
The Netherlands
Phone: +31 (0) 40 267 51 00
beha-amprobe.com
---|---|---

*(Correspondence only – no repair or replacement available from this address. European customers please contact your distributor.)
**single contact address in EEA Fluke Europe BV

The 2100-ACCS PROBE Test Probe Extender Kit is designed to allow Safe and reliable voltage measurements in tight spaces and on hard-to-access parts.
It contains the following items: 2 Test Probe extenders

SYMBOLS

**** Caution! Refer to the explanation in this user manual.
Equipment is protected by double insulation or

reinforced insulation.
| Complies with European directives.
| United Kingdom Conformity Assessed.
CAT III| Measurement Category III is applicable to test and
measuring circuits connected to the distribution part
of the building’s low-voltage MAINS installation.
CAT IV| Measurement Category IV is applicable to test and
measuring circuits connected at the source of the
building’s low-voltage MAINS installation.

SAFETY INFORMATION

  • Do not connect the test probe extender to voltage unless it is connected to an appropriate 2-pole voltage tester.
  • Ensure the test probe extender is securely attached before usage.
  • Do not touch the test probes at any time before and during the test when the product is connected to voltage.

Warnings: Read Before Using
To avoid the possibility of electric shock or personal injury:

  • Use the test probe extenders only as specified in this manual or the protection provided by the probes may be compromised.
  • Do not use the test probe extenders around explosive gas, vapor, or in a damp or environment exceeding IP40.
  • Inspect the test probe extenders before use and do not use if they appear damaged. Check for cracks or missing plastic. Pay particular attention to the insulation around the connectors.
  • Check the test probe extenders for continuity. Replace damaged probes before using the voltage tester.
  • Ensure the test probe extenders are securely screwed onto the voltage tester’s test probes before and during making measurements.
  • Use extreme caution when working around bare conductors or bus bars. Contact with the conductor could result in electric shock.
  • Do not apply more than the rated voltage and CAT rating, as marked on the voltage tester and/or the probe accessory, between the terminals or between any terminal and earth ground.
  • Do not exceed the Measurement Category (CAT) rating of the lowest-rated individual component of a voltage tester and/or the accessory.
  • Do not attempt to connect to any circuit carrying voltage that may exceed the maximum range of the voltage tester and/or the accessory.
  • When using probes, keep fingers behind the finger guards and follow the safety information of the voltage tester and the accessory.
  • Only use the test probe extenders with compatible voltage testers (see Specifications).

SPECIFICATIONS

2100-ACCS-PROBE

Designed for| BEHA-AMPROBE 2100 Alpha/Beta/Gamma/Delta and Fluke T90/T110, T130 and T150
---|---
Operating voltage / Safety rating| CAT IV 1000 V AC/DC / CAT III 1500 V DC
Operating current| max. 1 A
Safety regulations| IEC 61010-031
Protection degree| Mated: IP40 Unmated: IP20
Pollution degree| 2
Diameter of the metal tip| 2 mm
Length of the metal tip| 3.5 mm
Distance from tip to fingerguard (probe length)| 102 mm
Connection| Thread M3
Temperature range| -15 °C to 55 °C
Humidity| max. 95% RH
Operating altitude| Up to 2000 m
Dimensions| Approx. 133 x 22 mm
Weight| Approx. 6 g

03/2021, 6013893 A