Product Information
The product model is CRVFAS-xxR-xx-9CCT-120-W. The product is a flush-mount luminaire. The input rating of the luminaire should be checked before installation. The product comes with the following items:
- Fixture (1)
- Nuts (3)
- Screws (2)
The product is manufactured by Easy Answers located in Cranbury, New Jersey,
USA.
The product instruction code is CRVFA-IN-0821.
Product Usage Instructions
- Before installation, ensure that the power is turned off at the fuse box to prevent electrical shock.
- Read all product labels and directions for safety warnings.
- Installation with J-BOX:
- Make sure the power is turned off at the source to the J-box where you are installing the product.
- Disassemble the surface mount cover (see Fig.1).
- Select the desired color temperature (CCT) level using the switch (see Fig.2).
- Insert screws into J-Box holes, leaving about 15mm of space between the screw heads and J-Box (see Fig.3).
- Wire the surface mount by connecting white to white and black to black. Secure each wire connection with a wire nut (see Fig.4).
- Lift the fixture to the ceiling and carefully tuck the wires into the J-Box. Align the keyholes on the surface mount with the screws, then twist the fixture until the screws engage the narrow end of the keyholes. Tighten the screws to secure the fixture (see Fig.5).
- Reassemble the lamp cover (see Fig.6). Caulk around the mounting surface edge with silicone sealant (see Fig.7).
IMPORTANT
READ CAREFULLY BEFORE INSTALLING THE FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. RAB fixture must be wired in accordance with the National Electrical Code and all applicable local codes. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. TO PREVENT ELECTRICAL SHOCK, POWER SHOULD BE TURNED OFF AT THE FUSE BOX BEFORE INSTALLATION.
SAFETY WARNINGS:
Read all product labels and directions.
- WARNING – Risk of fire or electric shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire.
- Installation should be performed only by a qualified electrician in accordance with the National Electrical Code and relevant local codes. Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
- WARNING – To prevent wiring damage or abrasion, do not expose wiring to the edges of sheet metal or other sharp objects.
- INSTALLATION SHOULD ONLY BE PERFORMED AFTER THE POWER TO THE FIXTURE HAS BEEN DISCONNECTED.
- These instructions shall be included on an information sheet packaged with each unit:
FCC
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- this device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
WHAT’S IN THE BOX
TOOLS NEEDED
- Installation with J-BOX
A screwdriver is needed for installation.
INSTALLATION WITH J-BOX
- Make sure the POWER IS TURNED OFF at the source to the J-box in which you are installing the product.
- Disassemble the surface mount cover. (Fig.1)
- Select the desired CCT level using a switch. (Fig.2)
- Insert screws into J-Box holes, leaving about 15mm of space between the screw heads and J-Box. (Fig.3)
- Wire the surface mount, white-white, black-black. Once wire connections are made, secure each with a wire nut.(Fig.4)
- Lift fixture to ceiling and carefully tuck wires into J-Box. Align keyholes on the surface mount with screws, then twist fixture until the crews engage the narrow end of the keyholes. Tighten screws to secure. (Fig.5)
- Reassemble the lamp cover. (Fig.6)
Caulk around the mounting surface edge with silicone sealant. (Fig.7)
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation, or maintenance.
Easy Answers
rablighting.com
Visit our website for product info
Tech Help Line
Call our experts: 888 722-1000
e-mail
Answered promptly – sales@rablighting.com
Free Lighting Layouts
Answered online or by request.
RAB WARRANTY: RAB’s warranty is subject to all terms and conditions found at rablighting.com/warranty.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>