luminii Stenos Recessed Trimmed Track Sections Installation Guide
- June 13, 2024
- luminii
Table of Contents
- Stenos Installation Instructions
- Recessed Trimmed Track
- S – Recessed Trimmed Track – Straight Run
- Marking location and installing mounting brackets
- Continuous Row Mounting (if applicable)
- L – Recessed Trimmed Track – L Shape
- Marking location and installing mounting brackets
- Mount next track section in the ceiling and join to previous track
- Install Electrical L Joiner and Magnetic Cover Plates
- U – Recessed Trimmed Track – U Shape
- Marking location and installing mounting brackets
- Mount next track section to the ceiling and join to previous track
- Install Electrical L Joiner and Magnetic Cover Plates
- R – Recessed Trimmed Track – Rectangle
- Marking location and installing mounting brackets
- Mount next track section to the ceiling and join to previous track
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
REV0.4 7777 Merrimac Ave
09202023 Niles, IL 60714
T 224.333.6033
F 224.757.7557
info@luminii.com
www.luminii.com
Stenos Installation Instructions
Recessed Trimmed Track
Please read all instructions prior to installation and keep for future reference!
1. Product to be installed by a qualified electrician
2. Use only with class 2 power unit
3. 24 Volts DC
4. Suitable for dry locations only
5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.
6. Mechanical Joiners and End Cap isolate power circuits. Electrical
Joiners are used to continue power down the track.
7. System shapes and power feed locations shown are for reference only.
Refer to custom drawing package for the particulars of a specific custom
system.
Straight Run
L Shape
U Shape
Rectangle
IMPORTANT SAFETY INSTRUCTIONS!
WHEN INSTALLING OR USING THIS TRACK SYSTEM, BASIC SAFETY PRECAUTIONS SHOULD
ALWAYS BE FOLLOWED, INCLUDING:
A. READ ALL INSTRUCTIONS.
B. DO NOT INSTALL THIS TRACK IN DAMP OR WET LOCATIONS.
C. DO NOT INSTALL ANY PART OF THE TRACK SYSTEM LESS THAN 5 FEET ABOVE THE
FLOOR.
D. DO NOT INSTALL ANY LUMINAIRE ASSEMBLY CLOSER THAN 6 INCHES FROM ANY
CURTAIN, OR SIMILAR COMBUSTIBLE MATERIAL.
E. DISCONNECT ELECTRICAL POWER BEFORE ADDING TO OR CHANGING THE CONFIGURATION
OF THE TRACK.
F. DO NOT ATTEMPT TO ENERGIZE ANYTHING OTHER THAN LIGHTING TRACK LUMINAIRES ON
THE TRACK. TO REDUCE THE RISK OF FIRE AND ELECTRIC SHOCK, DO NOT ATTEMPT TO
CONNECT POWER TOOLS, EXTENSION CORDS, APPLIANCES, AND THE LIKE TO THE TRACK.
S – Recessed Trimmed Track – Straight Run
Track Installation Sequence
ATTENTION!
Make sure to install the tracks in the order that are specified on this page.
a) Power Feed
b) Cover Plate
Marking location and installing mounting brackets
(S.1)
Track Length
| # of Brackets
---|---
4ft|
3
8ft
| 4
12ft|
6
S.1 IMPORTANT! Brackets are to be mounted 3-4″ from the end of the track, and spaced apart no greater than 22″. All measurements are from the centerline of the bracket.
- Wing Clamp
S.2 With drywall already installed, create a cutout in the ceiling 1-1/16″ wide by (track length + 3/8″) length. Refer to approved Custom Layout Drawing by Luminii for precise ceiling cutout dimensions. Insert the mounting brackets into the ceiling cutout. Turn screw to rotate wing clamp and tighten until mounting bracket is secured to the ceiling.
- Mounting Bracket
- Recessed Trimmed Track
- 6ft Power feed cable
- Power Feed connector
- Cover Plate
S.3 Route Power Feed Cable through pre-drilled hole in track and make connection to power supply or junction box (by others). Then insert the track into the mounting brackets to engage the spring clips, securing the track in place.
S.4 Snap Power Feed Connector into Track. Rotate locking cam, securing
Power Feed Connector to track.
Do not over-rotate locking cam.
Place magnetic Cover Plate over Power Feed Connector.
- Do not over-rotate locking cam.
Continuous Row Mounting (if applicable)
(S.5)
a) Support this end when pulling other side down.
b) Mechanical Straight Joiner
c) Set screws
S.5 Once track section 1 is attached to the ceiling, raise track section
2 making sure to line the track up neatly with the mounting brackets. Pull
down slightly the open end of track section 1 to prepare for assembly with
track section 2.
NOTE: To prevent track from disconnecting from mounting brackets, make sure
that the other end of section is supported by another person or has temporary
supports installed
S.6 Slide section 2 into section 1 and tighten the set screws in the mechanical straight joiner
S.7 Once joined, insert the two track sections into the mounting brackets to engage the spring clips, securing the tracks.
Install Electrical Straight Joiners Magnetic Cover Plates (if continuous row mounting)
(S.8)
- Stenos Track
- Mechanical Straight Joiner
- Dowel pins
- Electrical Straight Joiner
- Dowel pin holes
S.8 Align Electrical Straight Joiner dowel pin holes with dowel pins of Mechanical Straight Joiner
- Do not over-rotate locking cam.
Perform a continuity check between the track conductors and the power cable to ensure that the power feed/joiner is sitting properly in the track.
S.9 Snap Electrical Straight Joiner into Track
S.10 Rotate locking cams, securing Electrical Straight Joiner to track. Do not over-rotate locking cam.
S.11 Place magnetic Cover Plate over Electrical Straight Joiner
L – Recessed Trimmed Track – L Shape
Track Installation Sequence
ATTENTION!
Make sure to install the tracks in the order that are specified on this page.
a) Cover Plate
b) Power Feed
Marking location and installing mounting brackets
(L.1)
Track Length
| # of Brackets
---|---
4ft|
3
8ft
| 4
12ft|
6
L.1 IMPORTANT! Brackets are to be mounted 3-4″ from the end of the track, and spaced apart no greater than 22″. All measurements are from the centerline of the bracket.
- Wing Clamp
L.2 With drywall already installed, create a cutout in the ceiling 1-1/16″ wide by (track length + 3/8″) length. Refer to approved Custom Layout Drawing by Luminii for precise ceiling cutout dimensions. Insert the mounting brackets into the ceiling cutout. Turn screw to rotate wing clamp and tighten until mounting bracket is secured to the ceiling.
- Mounting Bracket
- Recessed Trimmed Track
- 6ft Power feed cable
- Power Feed connector
- Cover Plate
L.3 Route Power Feed Cable through pre-drilled hole in track and make connection to power supply or junction box (by others). Then insert the track into the mounting brackets to engage the spring clips, securing the track in place.
L.4 Snap Power Feed Connector into Track. Rotate locking cam, securing
Power Feed Connector to track.
Do not over-rotate locking cam.
Place magnetic Cover Plate over Power Feed Connector.
- Do not over-rotate locking cam.
Mount next track section in the ceiling and join to previous track
section(s)
(L.5)
a) Mechanical L Joiner
b) M3 Screw (provided)
L.5 Once track section 1 is attached to the surface, raise track section 2 making sure to line the track up neatly with the mounting brackets. Insert track section 2 into mounting brackets to engage the spring clips, securing the track.
L.6 Assemble track section 2 to track section 1 and tighten M3 screws (provided) on Mechanical L Joiner.
L.7 If this leg consists of multiple track sections joined continuously, refer to steps S.5 – S.7 for continuous row mounting.
Install Electrical L Joiner and Magnetic Cover Plates
(L.8)
- Do not over-rotate locking cam.
Perform a continuity check between the track conductors and the power cable to ensure that the power feed/joiner is sitting properly in the track.
L.8 Snap Electrical L Joiner into Track
L.9 Rotate locking cams, securing Electrical L Joiner to track. Do not over-rotate locking cam.
L.10 Place magnetic Cover Plate over Electrical L Joiner.
U – Recessed Trimmed Track – U Shape
Track Installation Sequence
ATTENTION!
Make sure to install the tracks in the order that are specified on this page.
a) Power Feed
b) Cover Plate
Marking location and installing mounting brackets
(U.1)
Track Length
| # of Brackets
---|---
4ft|
3
8ft
| 4
12ft|
6
U.1 IMPORTANT! Brackets are to be mounted 3-4″ from the end of the track, and spaced apart no greater than 22″. All measurements are from the centerline of the bracket.
- Wing Clamp
U.2 With drywall already installed, create a cutout in the ceiling 1-1/16″ wide by (track length + 3/8″) length. Refer to approved Custom Layout Drawing by Luminii for precise ceiling cutout dimensions. Insert the mounting brackets into the ceiling cutout. Turn screw to rotate wing clamp and tighten until mounting bracket is secured to the ceiling.
- Mounting Bracket
- Recessed Trimmed Track
- 6ft Power feed cable
- Power Feed connector
- Cover Plate
U.3 Route Power Feed Cable through pre-drilled hole in track and make connection to power supply or junction box (by others). Then insert the track into the mounting brackets to engage the spring clips, securing the track in place.
U.4 Snap Power Feed Connector into Track. Rotate locking cam, securing
Power Feed Connector to track.
Do not over-rotate locking cam.
Place magnetic Cover Plate over Power Feed Connector.
- Do not over-rotate locking cam.
Mount next track section to the ceiling and join to previous track
section(s)
(U.5)
a) Mechanical L Joiner
b) M3 Screw (provided)
U.5 Once track section 1 is attached to the surface, raise track section 2 making sure to line the track up neatly with the mounting brackets. Insert track section 2 into mounting brackets to engage the spring clips, securing the track.
U.6 Assemble track section 2 to track section 1 and tighten M3 screws (provided) on Mechanical L Joiner. If this leg consists of multiple track sections joined continuously, refer to steps S.5 – S.7 for continuous row mounting.
U.7 Raise track section 3 making sure to line the track up neatly with the mounting brackets. Insert track section 3 into mounting brackets to engage the spring clips, securing the track.
U.8 Assemble track section 3 to track section 2 and tighten M3 screws (provided) on Mechanical L Joiner. If this leg consists of multiple track sections joined continuously, refer to steps S.5 – S.7 for continuous row mounting.
Install Electrical L Joiner and Magnetic Cover Plates
(U.9)
- Do not over-rotate locking cam.
Perform a continuity check between the track conductors and the power cable to ensure that the power feed/joiner is sitting properly in the track.
U.9 Snap Electrical L Joiner into Track
U.10 Rotate locking cams, securing Electrical L Joiner to track. Do not over-rotate locking cam.
U.11 Place magnetic Cover Plate over Electrical L Joiner.
R – Recessed Trimmed Track – Rectangle
Track Installation Sequence
ATTENTION!
Make sure to install the tracks in the order that are specified on this page.
a) Powerfeed
b) Cover Plate
Marking location and installing mounting brackets
(R.1)
Track Length
| # of Brackets
---|---
4ft|
3
8ft
| 4
12ft|
6
R.1 IMPORTANT! Brackets are to be mounted 3-4″ from the end of the track, and spaced apart no greater than 22″. All measurements are from the centerline of the bracket.
- Wing Clamp
R.2 With drywall already installed, create a cutout in the ceiling 1-1/16″ wide by (track length + 3/8″) length. Refer to approved Custom Layout Drawing by Luminii for precise ceiling cutout dimensions. Insert the mounting brackets into the ceiling cutout. Turn screw to rotate wing clamp and tighten until mounting bracket is secured to the ceiling.
- Mounting Bracket
- Recessed Trimmed Track
R.3 Insert track section 1 into the mounting brackets to engage the spring clips, securing the track in place.
R.4 Route Power Feed Cables through pre-drilled holes in track sections 2
and 4. Snap Power Feed Connectors into the tracks. Rotate locking cams,
securing Power Feed Connectors to track.
Do not over-rotate cam.
Place magnetic Cover Plate over Power Feed Connector.
- Do not over-rotate locking cam.
Mount next track section to the ceiling and join to previous track
section(s)
(U.5)
a) M3 Screw (provided)
b) Mechanical L Joiner
R.5 Once track section 1 is attached in the ceiling, raise track section 2 making sure to line the track up neatly with the mounting brackets.
R.6 Route Power Feed Cable of track section 2 through hole in ceiling and make connection to power supply or junction box (by others). Insert track section 2 into mounting brackets to engage the spring clips, securing the track.
R.7 Assemble track section 2 to track section 1 and tighten M3 screws (provided) on Mechanical L Joiner. If this leg consists of multiple track sections joined continuously, refer to steps S.5 – S.7 for continuous row mounting.
R.8 Raise track section 3 making sure to line the track up neatly with the mounting brackets. Insert track section 3 into mounting brackets to engage the spring clips, securing the track.
R.9 Assemble track section 3 to track section 2 and tighten M3 screws (provided) on Mechanical L Joiner. If this leg consists of multiple track sections joined continuously, refer to steps S.5 – S.7 for continuous row mounting.
R.10 Raise track section 4 making sure to line the track up neatly with mounting brackets.
R.11 Route Power Feed Cable of track section 4 through hole in ceiling and make connection to power supply or junction box (by others). Insert track section 4 into mounting brackets to engage the spring clips, securing the track.
R.12 Assemble track section 4 to track section 3 and tighten M3 screws (provided) on Mechanical L Joiner. If this leg consists of multiple track sections joined continuously, refer to steps S.5 – S.7 for continuous row mounting.
(R.13)
Perform a continuity check between the track conductors and the power cable to ensure that the power feed/joiner is sitting properly in the track.
R.13 Snap Electrical L Joiners into Track
R.14 Rotate locking cams, securing Electrical L Joiners to track. Do not over-rotate locking cam.
R.15 Place magnetic Cover Plate over Electrical L Joiners.
R.16 Place Magnetic L Cover Plates over and Power Feeds.
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE