luminii Stenos Suspended Track Installation Guide
- June 13, 2024
- luminii
Table of Contents
luminii Stenos Suspended Track Installation Guide
Please read all instructions prior to installation and keep for future reference!
- Product to be installed by a qualified electrician
- Use only with class 2 power unit
- 24 Volts DC
- Suitable for dry locations only
- 96W max, 24ft max, and 3 Electrical Joiners max per power feed.
- Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are used to continue power down the track.
- System shapes and power feed locations shown are for reference only. Refer to custom drawing package for the particulars of a specific custom system.
IMPORTANT SAFETY INSTRUCTIONS!
WHEN INSTALLING OR USING THIS TRACK SYSTEM, BASIC SAFETY PRECAUTIONS SHOULD
ALWAYS BE FOLLOWED, INCLUDING:
A. READ ALL INSTRUCTIONS.
B. DO NOT INSTALL THIS TRACK IN DAMP OR WET LOCATIONS.
C. DO NOT INSTALL ANY PART OF THE TRACK SYSTEM LESS THAN 5 FEET ABOVE THE
FLOOR.
D. DO NOT INSTALL ANY LUMINAIRE ASSEMBLY CLOSER THAN 6 INCHES FROM ANY
CURTAIN, OR SIMILAR COMBUSTIBLE MATERIAL.
E. DISCONNECT ELECTRICAL POWER BEFORE ADDING TO OR CHANGING THE CONFIGURATION
OF THE TRACK.
F. DO NOT ATTEMPT TO ENERGIZE ANYTHING OTHER THAN LIGHTING TRACK LUMINAIRES ON
THE TRACK. TO REDUCE THE RISK OF FIRE AND ELECTRIC SHOCK, DO NOT
ATTEMPT TO CONNECT POWER TOOLS, EXTENSION CORDS, APPLIANCES, AND THE LIKE TO
THE TRACK.
Mounting Preparations
Suspended Track – Straight Run
Power Feed Installation
Canopy Installation (steps require multiple people)
Continuous Row Mounting (if applicable)
S.10 Connect A/C cable to cable gripper on track section 2, following step
S.2.
S.11 Slide track section 2 onto straight mechanical joiner on track section 1.
Adjust position following steps S.2-S.4.
S.12 Once the two tracks are leveled, tighten the set screws on the mechanical
straight joiner to secure.
L – Suspended Track – L Shape
Marking location and installing mounting brackets
Power Feed Installation
Mount next track section to the ceiling and join to previous track section(s)
Install Electrical L Joiner and Cosmetic Finish Plates
U – Suspended Track – U Shape
Marking location and installing mounting brackets
Power Feed Installation
Mount next track section to the ceiling and join to previous track section(s)
R – Suspended Track – Rectangle Shape
Power Feed Installation
Marking location and installing mounting brackets
Mount next track section to the ceiling and join to previous track section(s)
R.12 Connect A/C cable to cable gripper on track section 2, following step U.2
.
R.13 Slide track section 2 onto mechanical L joiner on track section 1. Adjust
position following steps R.10-R.11
R.14 Once the two tracks are leveled, tighten the set screws on the mechanical
L joiner to secure.
R.15 Repeat steps R.12-R.14 for track section 3.
R.16 Slide track section 4 onto mechanical L joiners on track section 1 and
track sections 3. Adjust position following steps R.10-R.11.
R.17 Once the two tracks are leveled, tighten the set screws on the mechanical
L joiner to secure.
Install Electrical L Joiners and Magnetic Cover Plates