Luminii Stenos Surface Track Instruction Manual
- June 13, 2024
- luminii
Table of Contents
Stenos Surface Track
Product Information
The Stenos Surface Track is a lighting track system designed for
installation by a qualified electrician. It operates on 24 Volts DC
and is suitable for dry locations only. The track has a maximum
power capacity of 96W and can extend up to 24ft. It supports a
maximum of 3 Electrical Joiners per power feed. The Mechanical
Joiners and End Cap are used to isolate power circuits, while the
Electrical Joiners (REV0.6) allow for the continuation of power
down the track. The system shapes and power feed locations shown in
the manual are for reference only, and specific custom systems
should refer to the custom drawing package for accurate
details.
Product Usage Instructions
Important Safety Instructions:
-
Always follow basic safety precautions when installing or using
this track system. -
Do not attempt to connect power tools, extension cords,
appliances, or similar devices to the track.
Track Installation Sequence:
Follow the specified order for installing the tracks:
- Install the Power Feed.
- Attach the Cover Plate.
Marking Location and Installing Mounting Brackets:
To ensure proper installation, follow these steps:
-
Mark the location for mounting brackets on the ceiling or
wall. -
The brackets should be mounted 3-4 inches from the end of the
track. -
The spacing between brackets should not exceed 30 inches.
-
Use drywall anchors and #6 screws to secure the mounting
brackets.
Please note: The specifications and instructions for the
Stenos Surface Track are subject to change without notice. For
accurate details on system shapes and power feed locations, refer
to the custom drawing package for your specific custom
system.
Stenos Installation Instructions
Surface Track
Please read all instructions prior to installation and keep for future reference!
1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC 4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.
6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6
used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer
09122023
to custom drawing package for the particulars of a specific custom system.
1 / 17
7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com
Straight Run
L Shape
U Shape
Rectangle Shape
IMPORTANT SAFETY INSTRUCTIONS!
WHEN INSTALLING OR USING THIS TRACK SYSTEM, BASIC SAFETY PRECAUTIONS SHOULD
ALWAYS BE FOLLOWED, INCLUDING:
Table of Contents
Section
Page
Straight Run
2
L Shape
6
U Shape
10
Rectangle Shape 14
A. READ ALL INSTRUCTIONS. B. DO NOT INSTALL THIS TRACK IN DAMP OR WET
LOCATIONS. C. DO NOT INSTALL ANY PART OF THE TRACK SYSTEM LESS THAN 5 FEET
ABOVE THE FLOOR. D. DO NOT INSTALL ANY LUMINAIRE ASSEMBLY CLOSER THAN 6 INCHES
FROM ANY CURTAIN, OR SIMILAR COMBUSTIBLE MATERIAL. E. DISCONNECT ELECTRICAL
POWER BEFORE ADDING TO OR CHANGING THE CONFIGURATION OF THE TRACK. F. DO NOT
ATTEMPT TO ENERGIZE ANYTHING OTHER THAN LIGHTING TRACK LUMINAIRES ON THE
TRACK. TO REDUCE THE RISK OF FIRE AND ELECTRIC SHOCK, DO NOT
ATTEMPT TO CONNECT POWER TOOLS, EXTENSION CORDS, APPLIANCES, AND THE LIKE TO
THE TRACK.
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Stenos Installation Instructions
Surface Track
Please read all instructions prior to installation and keep for future reference!
1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC 4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.
6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6
used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer
09122023
to custom drawing package for the particulars of a specific custom system.
2 / 17
Surface Track L Shape
7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com
Track Installation Sequence
ATTENTION! Make sure to install the tracks in the order that are specified on
this page.
Power Feed
1
Cover Plate
2
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Stenos Installation Instructions
Surface Track
Please read all instructions prior to installation and keep for future reference!
1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC
6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6
used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer
09122023
4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.
to custom drawing package for the particulars of a specific custom system.
3 / 17
Marking location and installing mounting brackets
S
3″ – 4″
Max 30″
Track Length 4ft 8ft 12ft
of Brackets 3 4 6
3″ – 4″
0.375″
Mounting bracket
7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557
info@luminii.com www.luminii.com
Drywall anchor
6 screw
Power feed location
S.1 IMPORTANT! Brackets are to be mounted 3-4″ from the end of the track, and
spaced apart no greater than 30″. Take care to measure and mark where you want
to place ceiling brackets before drilling into wall or ceiling
S.2 For each mounting bracket. Drill a hole into the drywall using 13/64 drillbit and insert drywall anchor. Screw the mounting bracket into the anchor using a #6 screw. If installing to a hollow ceiling or concrete, must use a #6 screw size anchor that is rated for a minimum of 30lbs. For Powerfeed routing, drill a hole into the drywall using 3/8″ drillbit.
Mounting Bracket Surface Track
1
6ft Power feed
Power Feed
Cover Plate
S.3 Route Power Feed Cable through pre-drilled hole in track. Snap Power Feed
Connector into Track. Rotate locking cam, securing Power Feed Connector to
track. Do not over-rotate locking cam. Place magnetic Cover Plate over Power
Feed Connector.
S.4 Route Power Feed Cable through hole in ceiling and make connection to
power supply or junction box (by others).
S.5 Assemble track section 1 to the mounting brackets. The brackets are
rotated in a clockwise direction to lock into the rear of the track.
1 1
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Stenos Installation Instructions
Surface Track
Please read all instructions prior to installation and keep for future reference!
1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC
6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6
used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer
09122023
4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.
to custom drawing package for the particulars of a specific custom system.
4 / 17
Continuous Row Mounting (if applicable)
S.6
7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com
1 S.6
2 1
S.7 Mechanical Straight Joiner 2
Set screws
1 S.8
2
S.6 Once track section 1 is attached to the surface, raise track section 2
making sure to line the track up neatly with the mounting brackets. S.7
Assemble track section 2 to track section 1 and tighten set screws on
Mechanical Straight Joiner. S.8 Once the two tracks are connected, rotate
mounting brackets to lock to surface.
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Stenos Installation Instructions
Surface Track
Please read all instructions prior to installation and keep for future reference!
1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC
6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6
used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer
09122023
4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.
to custom drawing package for the particulars of a specific custom system.
5 / 17
Install Electrical Straight Joiners Magnetic Cover Plates (if continuous row mounting)
7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com
S.9
Stenos Track
Mechanical Straight Joiner Dowel pins
Electrical Straight Joiner
S.9 Align Electrical Straight Joiner dowel pin holes with dowel pins of Mechanical Straight Joiner
Dowel pin holes
S.10
S.10
S.11
S.12
Do not over-rotate locking cam.
S.10 Snap Electrical Straight Joiner into Track S.11 Rotate locking cams, securing Electrical Straight Joiner to track. Do not over-rotate locking cam. S.12 Place magnetic Cover Plate over Electrical Straight Joiner
Perform a continuity check between the track conductors and the power cable to ensure that the power feed/joiner is sitting properly in the track.
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Stenos Installation Instructions
Surface Track
Please read all instructions prior to installation and keep for future reference!
1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC 4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.
6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6
used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer
09122023
to custom drawing package for the particulars of a specific custom system.
6 / 17
Surface Track L Shape
7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com
Track Installation Sequence
ATTENTION! Make sure to install the tracks in the order that are specified on
this page.
1 Power Feed
2 Cover Plate
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Stenos Installation Instructions
Surface Track
Please read all instructions prior to installation and keep for future reference!
1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC
6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6
used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer
09122023
4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.
to custom drawing package for the particulars of a specific custom system.
7 / 17
Marking location and installing mounting brackets
L.1
3″ – 4″
Max 30″
Track Length 4ft 8ft 12ft
of Brackets 3 4 6
3″ – 4″
0.375″
Mounting bracket
7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557
info@luminii.com www.luminii.com
Drywall anchor
6 screw
Power feed location
L.1 IMPORTANT! Brackets are to be mounted 3-4″ from the end of the track, and
spaced apart no greater than 30″. Take care to measure and mark where you want
to place ceiling brackets before drilling into wall or ceiling
L.2 For each mounting bracket. Drill a hole into the drywall using 13/64 drillbit and insert drywall anchor. Screw the mounting bracket into the anchor using a #6 screw. If installing to a hollow ceiling or concrete, must use a #6 screw size anchor that is rated for a minimum of 30lbs. For Power feed routing, drill a hole into the drywall using 3/8″ drillbit.
Mounting Bracket Surface Track
1
1
6ft Power feed
Power Feed
Cover Plate
L.3 Route Power Feed Cable through pre-drilled hole in track. Snap Power Feed
Connector into Track. Rotate locking cam, securing Power Feed Connector to
track. Do not over-rotate locking cam. Place magnetic Cover Plate over Power
Feed Connector.
L.4 Route Power Feed Cable through hole in ceiling and make connection to
power supply or junction box (by others).
L.5 Assemble track section 1 to the mounting brackets. The brackets are
rotated in a clockwise direction to lock into the rear of the track.
If this leg consists of multiple track sections joined continuously, refer to
steps S.6 S.12 for continuous row mounting.
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Stenos Installation Instructions
Surface Track
Please read all instructions prior to installation and keep for future reference!
1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC 4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.
6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6
used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer
09122023
to custom drawing package for the particulars of a specific custom system.
8 / 17
Mount next track section to the ceiling and join to previous track section(s)
7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com
L.6
1
1 2 2
M3 Screw (provided)
M3 Screw (provided)
L.6 Once track section 1 is attached to the surface, raise track section 2
making sure to line the track up neatly with the mounting brackets. L.7
Assemble track section 2 to track section 1 and tighten M3 screws (provided)
on Mechanical L Joiner. Once the two tracks are connected, rotate mounting
brackets to lock to surface (L.8). If this leg consists of multiple track
sections joined continuously, refer to steps S.6 – S.12 for continuous row
mounting.
L.8
L.8 Once the two tracks are connected, rotate mounting brackets to lock to surface. *LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Stenos Installation Instructions
Surface Track
Please read all instructions prior to installation and keep for future reference!
1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC
6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6
used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer
09122023
4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.
to custom drawing package for the particulars of a specific custom system.
9 / 17
Install Electrical L Joiner and Magnetic Cover Plates
7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com
L.9
L.10
L.11
Do not over-rotate locking cam.
L.9 Snap Electrical L Joiner into Track L.10 Rotate locking cams, securing
Electrical L Joiner to track. Do not over-rotate locking cam. L.11 Place
magnetic Cover Plate over Electrical L Joiner .
Perform a continuity check between the track conductors and the power cable to ensure that the power feed/joiner is sitting properly in the track.
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Stenos Installation Instructions
Surface Track
Please read all instructions prior to installation and keep for future reference!
1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC 4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.
6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6
used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer
09122023
to custom drawing package for the particulars of a specific custom system.
10 / 17
U Surface Track U Shape
7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com
Track Installation Sequence
ATTENTION! Make sure to install the tracks in the order that are specified on
this page.
3 2
1 Power Feed
Cover Plate
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Stenos Installation Instructions
Surface Track
Please read all instructions prior to installation and keep for future reference!
1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC 4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.
6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6
used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer
09122023
to custom drawing package for the particulars of a specific custom system.
11 / 17
Marking location and installing mounting brackets
U.1
Track Length 4ft 8ft 12ft
of Brackets 3 4 6
3″ – 4″
Max 30″
3″ – 4″
0.375″
Mounting bracket
7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557
info@luminii.com www.luminii.com
Drywall anchor
6 screw
Power feed location
U.1 IMPORTANT! Brackets are to be mounted 3-4″ from the end of the track, and
spaced apart no greater than 30″. Take care to measure and mark where you want
to place ceiling brackets before drilling into wall or ceiling
U.2 For each mounting bracket. Drill a hole into the drywall using 13/64 drillbit and insert drywall anchor. Screw the mounting bracket into the anchor using a #6 screw. If installing to a hollow ceiling or concrete, must use a #6 screw size anchor that is rated for a minimum of 30lbs. For Power feed routing, drill a hole into the drywall using 3/8″ drillbit.
Mounting Bracket Surface Track
1
6ft Power feed
Power Feed
Cover Plate
U.3 Route Power Feed Cable through pre-drilled hole in track. Snap Power Feed
Connector into Track. Rotate locking cam, securing Power Feed Connector to
track. Do not over-rotate locking cam. Place magnetic Cover Plate over Power
Feed Connector.
U.4 Route Power Feed Cable through hole in ceiling and make connection to
power supply or junction box (by others).
U.5 Assemble the first section of track to the mounting brackets. The brackets
are rotated in a clockwise direction to lock into the rear of the track. If
this leg consists of multiple track sections joined continuously, refer to
steps S.6 S.12 for continuous row mounting.
1
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Stenos Installation Instructions
Surface Track
Please read all instructions prior to installation and keep for future reference!
1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC 4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.
6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6
used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer
09122023
to custom drawing package for the particulars of a specific custom system.
12 / 17
Mount next track section to the ceiling and join to previous track section(s)
U.6
7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com
2 3
M3 Screw (provided)
M3 Screw (provided)
1
U.6 Once track section 1 is attached to the surface, raise track section 2
making sure to line the track up neatly with the mounting brackets. U.7
Assemble track section 2 to track section 1 and tighten M3 screws (provided)
on Mechanical L Joiner. Once the two tracks are connected, rotate mounting
brackets to lock to surface (U.10). If this leg consists of multiple track
sections joined continuously, refer to steps S.6 – S.12 for continuous row
mounting. U.8 Raise track section 3 making sure to line the track up neatly
with the mounting brackets. U.9 Assemble track section 3 to track section 2
and tighten M3 screws (provided) on Mechanical L Joiner. Once the two tracks
are connected, rotate mounting
brackets to lock to surface (U.10). If this leg consists of multiple track
sections joined continuously, refer to steps S.6 – S.12 for continuous row
mounting.
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Stenos Installation Instructions
Surface Track
Please read all instructions prior to installation and keep for future reference!
1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC
6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6
used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer
09122023
4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.
to custom drawing package for the particulars of a specific custom system.
13 / 17
Mounting track segments to the ceiling and join to previous tracks (cont.)
7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com
U.10
U.10 Once the two tracks are connected, rotate mounting brackets to lock to surface.
Install Electrical L Joiners Magnetic Cover Plates
UL.191
UL..1102
UL..1113
Do not over-rotate locking cam.
U.11 Snap Electrical L Joiners into Track U.12 Rotate locking cams, securing
Electrical L Joiners to track. Do not over-rotate locking cam. U.13 Place
magnetic Cover Plate over Electrical L Joiners.
Perform a continuity check between the track conductors and the power cable to ensure that the power feed/joiner is sitting properly in the track.
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Stenos Installation Instructions
Surface Track
Please read all instructions prior to installation and keep for future reference!
1. Product to be installed by a qualified electrician 2. Use only with class
2 power unit 3. 24 Volts DC 4. Suitable for dry locations only 5. 96W max,
24ft max, and 3 Electrical Joiners max per power feed.
R Surface Track Rectangle Shape
6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6
used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer
09122023
to custom drawing package for the particulars of a specific custom system.
14 / 17
Track Installation Sequence
ATTENTION! Make sure to install the tracks in the order that are specified on
this page.
7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com
1 4
Power Feed 3
Cover Plate
2 Power Feed
Cover Plate
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Stenos Installation Instructions
Surface Track
Please read all instructions prior to installation and keep for future reference!
1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC
6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6
used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer
09122023
4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.
to custom drawing package for the particulars of a specific custom system.
15 / 17
Marking location and installing mounting brackets
R.1
3″ – 4″
Max 30″
Track Length 4ft 8ft 12ft
of Brackets 3 4 6
3″ – 4″
0.375″
Mounting bracket
7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557
info@luminii.com www.luminii.com
Drywall anchor
6 screw
Power feed location
R.1 IMPORTANT! Brackets are to be mounted 3-4″ from the end of the track, and
spaced apart no greater than 30″. Take care to measure and mark where you want
to place ceiling brackets before drilling into wall or ceiling
R.2 For each mounting bracket. Drill a hole into the drywall using 13/64 drillbit and insert drywall anchor. Screw the mounting bracket into the anchor using a #6 screw. If installing to a hollow ceiling or concrete, must use a #6 screw size anchor that is rated for a minimum of 30lbs. For Power feed routing, drill a hole into the drywall using 3/8″ drillbit.
Mounting Bracket
1
Surface Track
1
R.3 Once mounting brackets are screwed onto the selected surface, assemble the
track section 1 to the mounting brackets. The brackets are rotated in a
clockwise direction to lock into the rear of the track.
R.4 Route Power Feed Cables through pre-drilled holes in track sections 2 and
4. Snap Power Feed Connectors into tracks. Rotate locking cams, securing Power
Feed Connectors to track. Do not over-rotate locking cam.
2
4
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Stenos Installation Instructions
Surface Track
Please read all instructions prior to installation and keep for future reference!
1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC
6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6
used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer
09122023
4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.
to custom drawing package for the particulars of a specific custom system.
16 / 17
Mount next track section to the ceiling and join to previous track section(s)
R.5
7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com
1
4 3
2
M3 Screw (provided)
R.5 Once track section 1 is attached to the surface, raise track section 2
making sure to line the track up neatly with the mounting brackets. R.6 Route
Power Feed Cable of track section 2 through hole in ceiling and make
connection to power supply or junction box (by others). R.7 Assemble track
section 2 to track section 1 and tighten M3 screws (provided) on Mechanical L
Joiner. Once the two tracks are connected, rotate mounting brackets to lock to
surface (R.13). If this leg consists of multiple track sections joined
continuously, refer to steps S.6 – S.12 for continuous row mounting. R.8 Raise
track section 3 making sure to line the track up neatly with the mounting
brackets. R.9 Assemble track section 3 to track section 2 and tighten M3
screws (provided) on Mechanical L Joiner. Once the two tracks are connected,
rotate mounting brackets to lock to
surface (R.13). If this leg consists of multiple track sections joined
continuously, refer to steps S.6 – S.12 for continuous row mounting. R.10
Raise track section 4 making sure to line the track up neatly with mounting
brackets. R.11 Route Power Feed Cable of track section 4 through hole in
ceiling and make connection to power supply or junction box (by others). R.12
Assemble track section 4 to track section 3 and tighten M3 screws (provided)
on Mechanical L Joiner. Once the two tracks are connected, rotate mounting
brackets to lock to
surface (R.13). If this leg consists of multiple track sections joined
continuously, refer to steps S.6 – S.12 for continuous row mounting.
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Stenos Installation Instructions
Surface Track
Please read all instructions prior to installation and keep for future reference!
1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC 4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.
6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6
used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer
09122023
to custom drawing package for the particulars of a specific custom system.
17 / 17
7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com
R.13
R.13 Once the two tracks are connected, rotate mounting brackets to lock to
surface.
Install Electrical L Joiners and Magnetic Cover Plates
RL..194
RL.1105
RL..1116
Do not over-rotate locking cam.
R.14 Snap Electrical L Joiners into Track R.15 Rotate locking cams, securing
Electrical L Joiners to track. Do not over-rotate locking cam. R.16 Place
magnetic Cover Plate over Electrical L Joiners. R.17 Place Magnetic L Cover
Plates over and Power Feeds.
Perform a continuity check between the track conductors and the power cable to
ensure that the power feed/joiner is sitting properly in the track.
RL..1117
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Read User Manual Online (PDF format)