The Stenos Surface Track is a lighting track system designed for
installation by a qualified electrician. It operates on 24 Volts DC
and is suitable for dry locations only. The track has a maximum
power capacity of 96W and can extend up to 24ft. It supports a
maximum of 3 Electrical Joiners per power feed. The Mechanical
Joiners and End Cap are used to isolate power circuits, while the
Electrical Joiners (REV0.6) allow for the continuation of power
down the track. The system shapes and power feed locations shown in
the manual are for reference only, and specific custom systems
should refer to the custom drawing package for accurate
details.

Product Usage Instructions

Important Safety Instructions:

  • Always follow basic safety precautions when installing or using
    this track system.

  • Do not attempt to connect power tools, extension cords,
    appliances, or similar devices to the track.

Track Installation Sequence:

Follow the specified order for installing the tracks:

  1. Install the Power Feed.
  2. Attach the Cover Plate.

Marking Location and Installing Mounting Brackets:

To ensure proper installation, follow these steps:

  • Mark the location for mounting brackets on the ceiling or
    wall.

  • The brackets should be mounted 3-4 inches from the end of the
    track.

  • The spacing between brackets should not exceed 30 inches.

  • Use drywall anchors and #6 screws to secure the mounting
    brackets.

Please note: The specifications and instructions for the
Stenos Surface Track are subject to change without notice. For
accurate details on system shapes and power feed locations, refer
to the custom drawing package for your specific custom
system.

Stenos Installation Instructions

Surface Track

Please read all instructions prior to installation and keep for future reference!

1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC 4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.

6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6

used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer

09122023

to custom drawing package for the particulars of a specific custom system.

1 / 17

7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com

Straight Run

L Shape

U Shape

Rectangle Shape

IMPORTANT SAFETY INSTRUCTIONS!
WHEN INSTALLING OR USING THIS TRACK SYSTEM, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING:

Table of Contents

Section

Page

Straight Run

2

L Shape

6

U Shape

10

Rectangle Shape 14

A. READ ALL INSTRUCTIONS. B. DO NOT INSTALL THIS TRACK IN DAMP OR WET LOCATIONS. C. DO NOT INSTALL ANY PART OF THE TRACK SYSTEM LESS THAN 5 FEET ABOVE THE FLOOR. D. DO NOT INSTALL ANY LUMINAIRE ASSEMBLY CLOSER THAN 6 INCHES FROM ANY CURTAIN, OR SIMILAR COMBUSTIBLE MATERIAL. E. DISCONNECT ELECTRICAL POWER BEFORE ADDING TO OR CHANGING THE CONFIGURATION OF THE TRACK. F. DO NOT ATTEMPT TO ENERGIZE ANYTHING OTHER THAN LIGHTING TRACK LUMINAIRES ON THE TRACK. TO REDUCE THE RISK OF FIRE AND ELECTRIC SHOCK, DO NOT
ATTEMPT TO CONNECT POWER TOOLS, EXTENSION CORDS, APPLIANCES, AND THE LIKE TO THE TRACK.

*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE

Stenos Installation Instructions

Surface Track

Please read all instructions prior to installation and keep for future reference!

1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC 4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.

6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6

used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer

09122023

to custom drawing package for the particulars of a specific custom system.

2 / 17

Surface Track ­ L Shape

7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com

Track Installation Sequence
ATTENTION! Make sure to install the tracks in the order that are specified on this page.

Power Feed

1

Cover Plate

2

*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE

Stenos Installation Instructions

Surface Track

Please read all instructions prior to installation and keep for future reference!

1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC

6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6

used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer

09122023

4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.

to custom drawing package for the particulars of a specific custom system.

3 / 17

Marking location and installing mounting brackets

S
3″ – 4″

Max 30″

Track Length 4ft 8ft 12ft

of Brackets 3 4 6

3″ – 4″

0.375″

Mounting bracket

7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com
Drywall anchor

6 screw

Power feed location
S.1 IMPORTANT! Brackets are to be mounted 3-4″ from the end of the track, and spaced apart no greater than 30″. Take care to measure and mark where you want to place ceiling brackets before drilling into wall or ceiling

S.2 For each mounting bracket. Drill a hole into the drywall using 13/64 drillbit and insert drywall anchor. Screw the mounting bracket into the anchor using a #6 screw. If installing to a hollow ceiling or concrete, must use a #6 screw size anchor that is rated for a minimum of 30lbs. For Powerfeed routing, drill a hole into the drywall using 3/8″ drillbit.

Mounting Bracket Surface Track
1

6ft Power feed

Power Feed

Cover Plate

S.3 Route Power Feed Cable through pre-drilled hole in track. Snap Power Feed Connector into Track. Rotate locking cam, securing Power Feed Connector to track. Do not over-rotate locking cam. Place magnetic Cover Plate over Power Feed Connector.
S.4 Route Power Feed Cable through hole in ceiling and make connection to power supply or junction box (by others).
S.5 Assemble track section 1 to the mounting brackets. The brackets are rotated in a clockwise direction to lock into the rear of the track.

1 1
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE

Stenos Installation Instructions

Surface Track

Please read all instructions prior to installation and keep for future reference!

1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC

6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6

used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer

09122023

4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.

to custom drawing package for the particulars of a specific custom system.

4 / 17

Continuous Row Mounting (if applicable)

S.6

7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com

1 S.6

2 1
S.7 Mechanical Straight Joiner 2
Set screws
1 S.8
2

S.6 Once track section 1 is attached to the surface, raise track section 2 making sure to line the track up neatly with the mounting brackets. S.7 Assemble track section 2 to track section 1 and tighten set screws on Mechanical Straight Joiner. S.8 Once the two tracks are connected, rotate mounting brackets to lock to surface.
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE

Stenos Installation Instructions

Surface Track

Please read all instructions prior to installation and keep for future reference!

1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC

6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6

used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer

09122023

4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.

to custom drawing package for the particulars of a specific custom system.

5 / 17

Install Electrical Straight Joiners Magnetic Cover Plates (if continuous row mounting)

7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com

S.9

Stenos Track

Mechanical Straight Joiner Dowel pins

Electrical Straight Joiner

S.9 Align Electrical Straight Joiner dowel pin holes with dowel pins of Mechanical Straight Joiner

Dowel pin holes

S.10

S.10

S.11

S.12

Do not over-rotate locking cam.

S.10 Snap Electrical Straight Joiner into Track S.11 Rotate locking cams, securing Electrical Straight Joiner to track. Do not over-rotate locking cam. S.12 Place magnetic Cover Plate over Electrical Straight Joiner

Perform a continuity check between the track conductors and the power cable to ensure that the power feed/joiner is sitting properly in the track.

*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE

Stenos Installation Instructions

Surface Track

Please read all instructions prior to installation and keep for future reference!

1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC 4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.

6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6

used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer

09122023

to custom drawing package for the particulars of a specific custom system.

6 / 17

Surface Track ­ L Shape

7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com

Track Installation Sequence
ATTENTION! Make sure to install the tracks in the order that are specified on this page.

1 Power Feed
2 Cover Plate
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE

Stenos Installation Instructions

Surface Track

Please read all instructions prior to installation and keep for future reference!

1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC

6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6

used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer

09122023

4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.

to custom drawing package for the particulars of a specific custom system.

7 / 17

Marking location and installing mounting brackets

L.1
3″ – 4″

Max 30″

Track Length 4ft 8ft 12ft

of Brackets 3 4 6

3″ – 4″

0.375″

Mounting bracket

7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com
Drywall anchor

6 screw

Power feed location
L.1 IMPORTANT! Brackets are to be mounted 3-4″ from the end of the track, and spaced apart no greater than 30″. Take care to measure and mark where you want to place ceiling brackets before drilling into wall or ceiling

L.2 For each mounting bracket. Drill a hole into the drywall using 13/64 drillbit and insert drywall anchor. Screw the mounting bracket into the anchor using a #6 screw. If installing to a hollow ceiling or concrete, must use a #6 screw size anchor that is rated for a minimum of 30lbs. For Power feed routing, drill a hole into the drywall using 3/8″ drillbit.

Mounting Bracket Surface Track
1
1

6ft Power feed

Power Feed

Cover Plate

L.3 Route Power Feed Cable through pre-drilled hole in track. Snap Power Feed Connector into Track. Rotate locking cam, securing Power Feed Connector to track. Do not over-rotate locking cam. Place magnetic Cover Plate over Power Feed Connector.
L.4 Route Power Feed Cable through hole in ceiling and make connection to power supply or junction box (by others).
L.5 Assemble track section 1 to the mounting brackets. The brackets are rotated in a clockwise direction to lock into the rear of the track.
If this leg consists of multiple track sections joined continuously, refer to steps S.6 S.12 for continuous row mounting.

*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE

Stenos Installation Instructions

Surface Track

Please read all instructions prior to installation and keep for future reference!

1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC 4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.

6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6

used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer

09122023

to custom drawing package for the particulars of a specific custom system.

8 / 17

Mount next track section to the ceiling and join to previous track section(s)

7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com

L.6

1
1 2 2

M3 Screw (provided)

M3 Screw (provided)

L.6 Once track section 1 is attached to the surface, raise track section 2 making sure to line the track up neatly with the mounting brackets. L.7 Assemble track section 2 to track section 1 and tighten M3 screws (provided) on Mechanical L Joiner. Once the two tracks are connected, rotate mounting
brackets to lock to surface (L.8). If this leg consists of multiple track sections joined continuously, refer to steps S.6 – S.12 for continuous row mounting.
L.8

L.8 Once the two tracks are connected, rotate mounting brackets to lock to surface. *LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE

Stenos Installation Instructions

Surface Track

Please read all instructions prior to installation and keep for future reference!

1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC

6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6

used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer

09122023

4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.

to custom drawing package for the particulars of a specific custom system.

9 / 17

Install Electrical L Joiner and Magnetic Cover Plates

7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com

L.9

L.10

L.11

Do not over-rotate locking cam.
L.9 Snap Electrical L Joiner into Track L.10 Rotate locking cams, securing Electrical L Joiner to track. Do not over-rotate locking cam. L.11 Place magnetic Cover Plate over Electrical L Joiner .

Perform a continuity check between the track conductors and the power cable to ensure that the power feed/joiner is sitting properly in the track.

*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE

Stenos Installation Instructions

Surface Track

Please read all instructions prior to installation and keep for future reference!

1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC 4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.

6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6

used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer

09122023

to custom drawing package for the particulars of a specific custom system.

10 / 17

U ­ Surface Track ­ U Shape

7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com

Track Installation Sequence
ATTENTION! Make sure to install the tracks in the order that are specified on this page.

3 2

1 Power Feed
Cover Plate

*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE

Stenos Installation Instructions

Surface Track

Please read all instructions prior to installation and keep for future reference!

1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC 4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.

6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6

used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer

09122023

to custom drawing package for the particulars of a specific custom system.

11 / 17

Marking location and installing mounting brackets

U.1

Track Length 4ft 8ft 12ft

of Brackets 3 4 6

3″ – 4″

Max 30″

3″ – 4″

0.375″

Mounting bracket

7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com
Drywall anchor

6 screw

Power feed location
U.1 IMPORTANT! Brackets are to be mounted 3-4″ from the end of the track, and spaced apart no greater than 30″. Take care to measure and mark where you want to place ceiling brackets before drilling into wall or ceiling

U.2 For each mounting bracket. Drill a hole into the drywall using 13/64 drillbit and insert drywall anchor. Screw the mounting bracket into the anchor using a #6 screw. If installing to a hollow ceiling or concrete, must use a #6 screw size anchor that is rated for a minimum of 30lbs. For Power feed routing, drill a hole into the drywall using 3/8″ drillbit.

Mounting Bracket Surface Track
1

6ft Power feed
Power Feed
Cover Plate
U.3 Route Power Feed Cable through pre-drilled hole in track. Snap Power Feed Connector into Track. Rotate locking cam, securing Power Feed Connector to track. Do not over-rotate locking cam. Place magnetic Cover Plate over Power Feed Connector.
U.4 Route Power Feed Cable through hole in ceiling and make connection to power supply or junction box (by others).
U.5 Assemble the first section of track to the mounting brackets. The brackets are rotated in a clockwise direction to lock into the rear of the track. If this leg consists of multiple track sections joined continuously, refer to steps S.6 S.12 for continuous row mounting.

1

*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE

Stenos Installation Instructions

Surface Track

Please read all instructions prior to installation and keep for future reference!

1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC 4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.

6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6

used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer

09122023

to custom drawing package for the particulars of a specific custom system.

12 / 17

Mount next track section to the ceiling and join to previous track section(s)

U.6

7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com

2 3

M3 Screw (provided)

M3 Screw (provided)
1

U.6 Once track section 1 is attached to the surface, raise track section 2 making sure to line the track up neatly with the mounting brackets. U.7 Assemble track section 2 to track section 1 and tighten M3 screws (provided) on Mechanical L Joiner. Once the two tracks are connected, rotate mounting
brackets to lock to surface (U.10). If this leg consists of multiple track sections joined continuously, refer to steps S.6 – S.12 for continuous row mounting. U.8 Raise track section 3 making sure to line the track up neatly with the mounting brackets. U.9 Assemble track section 3 to track section 2 and tighten M3 screws (provided) on Mechanical L Joiner. Once the two tracks are connected, rotate mounting
brackets to lock to surface (U.10). If this leg consists of multiple track sections joined continuously, refer to steps S.6 – S.12 for continuous row mounting.
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE

Stenos Installation Instructions

Surface Track

Please read all instructions prior to installation and keep for future reference!

1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC

6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6

used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer

09122023

4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.

to custom drawing package for the particulars of a specific custom system.

13 / 17

Mounting track segments to the ceiling and join to previous tracks (cont.)

7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com

U.10

U.10 Once the two tracks are connected, rotate mounting brackets to lock to surface.

Install Electrical L Joiners Magnetic Cover Plates

UL.191

UL..1102

UL..1113

Do not over-rotate locking cam.
U.11 Snap Electrical L Joiners into Track U.12 Rotate locking cams, securing Electrical L Joiners to track. Do not over-rotate locking cam. U.13 Place magnetic Cover Plate over Electrical L Joiners.

Perform a continuity check between the track conductors and the power cable to ensure that the power feed/joiner is sitting properly in the track.

*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE

Stenos Installation Instructions

Surface Track

Please read all instructions prior to installation and keep for future reference!

1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC 4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.
R ­ Surface Track ­ Rectangle Shape

6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6

used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer

09122023

to custom drawing package for the particulars of a specific custom system.

14 / 17

Track Installation Sequence
ATTENTION! Make sure to install the tracks in the order that are specified on this page.

7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com

1 4

Power Feed 3
Cover Plate

2 Power Feed
Cover Plate

*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE

Stenos Installation Instructions

Surface Track

Please read all instructions prior to installation and keep for future reference!

1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC

6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6

used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer

09122023

4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.

to custom drawing package for the particulars of a specific custom system.

15 / 17

Marking location and installing mounting brackets

R.1
3″ – 4″

Max 30″

Track Length 4ft 8ft 12ft

of Brackets 3 4 6

3″ – 4″

0.375″

Mounting bracket

7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com
Drywall anchor

6 screw

Power feed location
R.1 IMPORTANT! Brackets are to be mounted 3-4″ from the end of the track, and spaced apart no greater than 30″. Take care to measure and mark where you want to place ceiling brackets before drilling into wall or ceiling

R.2 For each mounting bracket. Drill a hole into the drywall using 13/64 drillbit and insert drywall anchor. Screw the mounting bracket into the anchor using a #6 screw. If installing to a hollow ceiling or concrete, must use a #6 screw size anchor that is rated for a minimum of 30lbs. For Power feed routing, drill a hole into the drywall using 3/8″ drillbit.

Mounting Bracket

1

Surface Track

1

R.3 Once mounting brackets are screwed onto the selected surface, assemble the track section 1 to the mounting brackets. The brackets are rotated in a clockwise direction to lock into the rear of the track.
R.4 Route Power Feed Cables through pre-drilled holes in track sections 2 and 4. Snap Power Feed Connectors into tracks. Rotate locking cams, securing Power Feed Connectors to track. Do not over-rotate locking cam.

2

4

*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE

Stenos Installation Instructions

Surface Track

Please read all instructions prior to installation and keep for future reference!

1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC

6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6

used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer

09122023

4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.

to custom drawing package for the particulars of a specific custom system.

16 / 17

Mount next track section to the ceiling and join to previous track section(s)

R.5

7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com

1

4 3

2
M3 Screw (provided)

R.5 Once track section 1 is attached to the surface, raise track section 2 making sure to line the track up neatly with the mounting brackets. R.6 Route Power Feed Cable of track section 2 through hole in ceiling and make connection to power supply or junction box (by others). R.7 Assemble track section 2 to track section 1 and tighten M3 screws (provided) on Mechanical L Joiner. Once the two tracks are connected, rotate mounting brackets to lock to
surface (R.13). If this leg consists of multiple track sections joined continuously, refer to steps S.6 – S.12 for continuous row mounting. R.8 Raise track section 3 making sure to line the track up neatly with the mounting brackets. R.9 Assemble track section 3 to track section 2 and tighten M3 screws (provided) on Mechanical L Joiner. Once the two tracks are connected, rotate mounting brackets to lock to
surface (R.13). If this leg consists of multiple track sections joined continuously, refer to steps S.6 – S.12 for continuous row mounting. R.10 Raise track section 4 making sure to line the track up neatly with mounting brackets. R.11 Route Power Feed Cable of track section 4 through hole in ceiling and make connection to power supply or junction box (by others). R.12 Assemble track section 4 to track section 3 and tighten M3 screws (provided) on Mechanical L Joiner. Once the two tracks are connected, rotate mounting brackets to lock to
surface (R.13). If this leg consists of multiple track sections joined continuously, refer to steps S.6 – S.12 for continuous row mounting.
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE

Stenos Installation Instructions

Surface Track

Please read all instructions prior to installation and keep for future reference!

1. Product to be installed by a qualified electrician 2. Use only with class 2 power unit 3. 24 Volts DC 4. Suitable for dry locations only 5. 96W max, 24ft max, and 3 Electrical Joiners max per power feed.

6. Mechanical Joiners and End Cap isolate power circuits. Electrical Joiners are REV0.6

used to continue power down the track. 7. System shapes and power feed locations shown are for reference only. Refer

09122023

to custom drawing package for the particulars of a specific custom system.

17 / 17

7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com

R.13

R.13 Once the two tracks are connected, rotate mounting brackets to lock to surface.
Install Electrical L Joiners and Magnetic Cover Plates

RL..194

RL.1105

RL..1116

Do not over-rotate locking cam.
R.14 Snap Electrical L Joiners into Track R.15 Rotate locking cams, securing Electrical L Joiners to track. Do not over-rotate locking cam. R.16 Place magnetic Cover Plate over Electrical L Joiners. R.17 Place Magnetic L Cover Plates over and Power Feeds.
Perform a continuity check between the track conductors and the power cable to ensure that the power feed/joiner is sitting properly in the track.