COOPER Lighting Solutions IB51928921 Luminaire WaveStream Instruction Manual
- June 13, 2024
- COOPER Lighting Solutions
Table of Contents
COOPER Lighting Solutions IB51928921 Luminaire WaveStream
Product Information
Product Code | IB51928921 |
---|---|
Brand | Metalux |
Product Usage Instructions
WARNING
- Risk of Fire, Electrical Shock, Cuts or other Casualty Hazards- Installation and maintenance of this product must be performed by a qualified electrician. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
- Risk of Fire and Electric Shock- Make certain power is OFF before starting installation or attempting any maintenance. Disconnect power at the fuse or circuit breaker.
- Risk of Burn- Disconnect power and allow the fixture to cool before handling or servicing.
- Risk of Personal Injury- Due to sharp edges, handle with care.
- Failure to comply with these instructions may result in death, serious bodily injury, and property damage.
INSTALLATION
Fixture Installation/Wiring
- Remove product from the packaging material. The carton should be lying flat, oriented with THIS SIDE UP markings facing up so that the top panel of the carton can be folded back and the fixture can be lifted straight up out of packaging materials. Do not lift the fixture by one or pull on the end plates in any way. The Luminaire should be handled by both aluminum side rails. Wear clean work gloves to prevent dirt and oil from being transferred to the luminaire.
- Note that the protective plastic insert that is shipped in the luminaire is intended to stay in the luminaire for protection of the lenses during installation (Figure 1.). Take caution when handling the luminaire to not scratch or damage the lenses in the fixture.
- Install the luminaire into the ceiling T-grid system. Ensure that the luminaire sets snuggly in the T-grid system (Figure 2.). Ensure that all luminaires in an area are oriented in the same direction.
- When required, attach EQ Clips to the luminaire end plate with supplied screws to secure the luminaire to the T-grid system (Figure 3.). Take care not to over-torque and strip screws.
- Remove the electrical access plate and remove necessary knockouts from the access plate for attachment of the electrical supply cable (Figure 4. and Figure 5.).
- Remove two screws in Electrical Enclosure and review the driver for electrical ratings and proper wiring of the LED driver. Replace Electrical Enclosure and secure it with the two screws previously removed.
- Standard Access Plate Installation: Grounding conductor (if insulated) to be stripped min. 1. Insert the end of the wire into a small hole. Wrap wire under and around the head of the screw counter-clockwise (Figure 4.). Tighten the screw.
- Flex Installation: Step 1: To insert the access plate, rotate until the leading end is inside the wireway (Figure 5.). Step 2: Fold into a horizontal position and slide forward into a locking position.
- Make necessary wiring connections to driver AC line input and optional DALI or 0-10V dimming circuits. See Wiring Diagrams*
- Constructions built before Jan 2022 may have gray wire for 0-10 dimming control present. In these cases, the installer will label the gray building wire as a 0-10 dimming wire and connect to our product’s pink 0-10V dimming control wire. Reference NFPA70 (2020 NEC), section 410.69.
- Replace the electrical access plate and snap it securely into place. If required, install an optional screw to lock the access plate closed.
WARNING
- Risk of Fire, Electrical Shock, Cuts or other Casualty Hazards- Installation and maintenance of this product must be performed by a qualified electrician. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
- Risk of Fire and Electric Shock- Make certain power is OFF before starting installation or attempting any maintenance. Disconnect power at the fuse or circuit breaker.
- Risk of Fire- Minimum 90°C supply conductors.
- Risk of Burn- Disconnect power and allow the fixture to cool before handling or servicing.
- Risk of Personal Injury- Due to sharp edges, handle with care.
- Failure to comply with these instructions may result in death, serious bodily injury, and property damage.
DISCLAIMER OF LIABILITY:
Cooper Lighting Solutions assumes no liability for damages or losses of any
kind that may arise from the improper, careless, or negligent installation,
handling or use of this product.
- IMPORTANT : Read carefully before installing the fixture. Retain for future reference.
- NOTICE : Green ground screw provided in the proper location. Do not relocate.
- NOTICE : The fixture may become damaged and/or unstable if not installed properly.
- Note : Specifications and dimensions are subject to change without notice.
- ATTENTION Receiving Department : Note the actual fixture description of any shortage or noticeable damage on the delivery receipt. File a claim for common carrier (LTL) directly with the carrier. Claims for concealed damage must be filed within 15 days of delivery. All damaged material, complete with original packing must be retained.
**INSTALLATION
**
Fixture Installation/Wiring
-
Remove product from the packaging material. The carton should be lying flat, oriented with THIS SIDE UP markings facing up so that the top panel of the carton can be folded back and the fixture can be lifted straight up out of packaging materials. Do not lift the fixture by one end or pull on the end plates in any way. The Luminaire should be handled by both aluminum side rails. Wear clean work gloves to prevent dirt and oil from being transferred to the luminaire.
-
Note that the protective plastic insert that is shipped in the luminaire is intended to stay in the luminaire for protection of the lenses during installation (Figure.). Take caution when handling the luminaire to not scratch or damage the lenses in the fixture.
-
Install the luminaire into the ceiling T-grid system. Ensure that the luminaire sets snuggly in the T-grid system (Figure 2.). Ensure that all luminaires in an area are oriented in the same direction.
-
When required, attach EQ Clips to the luminaire end plate with supplied screws to secure the luminaire to the T-grid system (Figure 3.). Take care not to over-torque and strip screws.
-
Remove the electrical access plate and remove necessary knockouts from the access plate for attachment of the electrical supply cable (Figure 4. and Figure 5.).
-
Remove two screws in Electrical Enclosure and review the driver label for electrical ratings and proper wiring of the LED driver. Replace Electrical Enclosure and secure it with the two screws previously removed.
Standard Access Plate Installation
Grounding conductor (if insulated) to be stripped min. 1″. Insert the end of the wire into a small hole. Wrap wire under and around the head of the screw counter-clockwise (Figure 4.). Tighten the screw.
Flex Installation- Step 1: To insert the access plate, rotate until the leading end is inside the wireway (Figure 5.).
- Step 2: Fold into a horizontal position and slide forward into a locking position.
-
Make necessary wiring connections to driver AC line input and optional DALI or 0-10Vdimming circuits. See Wiring Diagrams*
- Constructions built before Jan 2022 may have gray wire for 0-10 dimming control present. In these cases, the installer will label the gray building wire as a 0-10 dimming wire and connect to our product’s pink 0- 10V dimming control wire. Reference NFPA70 (2020 NEC), section 410.69. 8. Replace the electrical access plate and snap it securely into place. If required, install an optional screw to lock the access plate closed.
Final Luminaire Prep
The luminaire is shipped with a protective plastic insert that is intended to
stay in the luminaire during building construction to keep dust and dirt from
accumulating on the luminaire. Once all building construction and cleanup is
complete, the plastic insert is to be removed and recycled (Figure 6.).
MAINTENANCE
Fixture Maintenance/Cleaning
Always follow recommended cleaning and handling procedures when cleaning the
WaveStream lens. It can be permanently damaged if cleaned or handled
improperly. Before cleaning a WaveStream lens, take time to inspect the
surfaces carefully in order to determine the type and severity of the
contaminants. The process of cleaning the lens can result in damage to the
optical surface if repeated multiple times. For WaveStream lenses with
multiple contaminants, the order with which they are removed can be important.
For instance, if a WaveStream lens is contaminated with oil and dust, it is
possible that wiping the oil off first will scratch the optical surface as the
dust is drug along the surface by the wipe.
Blowing off the Surface of an Optic
Dust and other loose contaminants should be blown off before any other
cleaning technique is employed. Using compressed air over the entire lens is
recommended to prevent static buildup.
When using compressed air, hold the can upright throughout the procedure.
Also, start the flow of air with the nozzle pointed away from the lens. Hold
the can approximately 6″ from the optic and use short bursts. Move the nozzle
of the compressed air can over the optic with the nozzle at a grazing angle to
the optical surface in a constant one-way direction. Due to the non-contact
and solvent-free nature of this cleaning method, it should be used as a first
step in cleaning all AccuAim™ optics.
Additional Cleaning Methods
Fingerprints and large dust particles can be removed by gently wiping the
surface with a clean microfiber cloth. If additional cleaning is required a
mild solution of distilled water and Dawn® dish soap (between 1:20 and 1:10
parts Dawn to distilled water, respectively) could be used to wash the lens.
The WaveStream lens should not remain wet any longer than necessary to remove
the contaminants. Dry off the surface with deionized air. Avoid pooling of
water as that tends to leave streaks on the optical surface. This method is
only recommended as a last resort as it increases the risk of damaging the
lens.
Note : Avoid any organic solvents. In addition, avoid any cleaning
products including ammonia, ketones, window cleaners, or other alcohol-based
cleaners and solvents containing thinners, acetone, benzene, and
tetrachloride.
Note : For additional information on material compatibility in regard to
environmental contact with chemicals and solvents please visit
www.cooperlighting.com
SkyRidge™ Fixture Series
SkyTrim™
SkyTrim is a luminous decorative accent that can be mounted directly on the
light guide of a SkyRidge fixture. A co-extruded high-grade optical acrylic
strip, less than 0.5″ deep, the SkyTrim provides a simple means of applying
color to an existing or new fixture. SkyTrims are interchangeable and can be
modified after installation.
FCC Statement
Note : This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Warranties and Limitations of Liability
Please refer to www.cooperlighting.com for our terms and conditions
Cooper Lighting Solutions
1121 Highway 74 South Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com
Canada Sales
5925 McLaughlin Road Mississauga, Ontario L5R 1B8 P:
905-501-3000
F: 905-501-3172
© 2021 Cooper Lighting Solutions All Rights Reserved
Publication No. IB51928921 October 22, 2021
Cooper Lighting Solutions is a registered trademark. All trademarks are the
property of their respective owners.
Product availability, specifications, and compliances are subject to change
without notice