ACCURATE M8800ELR Motor Drive Electrified Latch Retraction Narrow Backset Mortise Lock Instructions
- June 13, 2024
- Accurate
Table of Contents
ACCURATE M8800ELR Motor Drive Electrified Latch Retraction Narrow Backset Mortise Lock
M8800ELR MOTOR DRIVE ELECTRIFIED LATCH RETRACTION
Outside trim (or both outside and inside trim depending on the lock function)
is locked.
The main latch bolt is retracted when power is applied.
The main latch bolt is extended in the event of a power failure.
KEY FUNCTION
The main latch bolt may be momentarily retracted with a key
ELECTRICAL SPECIFICATIONS
Filtered and Regulated Power Supply.
VOLTAGE: 24VDC (21VDC – 30VDC)
CURRENT: 625 mA MAX Inrush, 150 mA MAX Holding Non-polarized leads.
2 Conductor Wire Run
Distance| Wire Gauge
125’| 22
200’| 20
350’| 18
500’| 16
800’| 14
1250’| 12
ONBOARD INDICATOR LIGHT ASSIGNMENTS
Maintain input power to the mortise lock and check the onboard indicator lights. Remove input power before attempting a solution.
GREEN
(POWER)
| YELLOW
(SENSOR)
| RED
(ERROR)
| INDICATION| POSSIBLE SOLUTION
---|---|---|---|---
Off| Off| Off| No Power.| Connect the wiring between the power supply and the
mortise lock.
On| On| Off| Normal Operation. The main latch bolt is retracted to the preset
retracted position. The device is allowed 2 attempts.|
On| Off| On| Error in operation. The main latch bolt did not retract to
the preset retracted position within 2 attempts
| Clear the jam condition manually.
On| On| On| Error in operation. Without power being removed, the main latch
bolt unintentionally extended from the preset retracted position, and then the
main latch bolt did not retract back to the preset retracted position within 2
attempts.| Clear the jam condition manually.
On| Blink| On| Error in operation. The main latch bolt did not extend from the
preset retracted position when the power was last
removed. The device will not attempt a retraction.
| Clear the jam condition manually.
On| Simultaneous Blink| Error in operation. The input voltage dropped below
the specification during operation.| Decrease the wire run or increase the
wire gauge.
On| Alternating Blink| Error in operation. An electronics fault was detected.|
An electronics replacement is required.
CUSTOMERS SUPPORT
1 Annie Place Stamford, CT 06902 | 203.348.8865
www.accuratelockandhardware.com
References