ACCURATE M9143ELR Accesible Restroom Lock Instructions
- June 13, 2024
- Accurate
Table of Contents
ACCURATE M9143ELR Accesible Restroom Lock
INTRODUCTION
Furnished standard with LB Locking Bar Monitor.
Latch bolt by handle either side unless outside handle is locked by thumb turn
or key.
Rotating thumb turn locks outside handle and deactivates outside push paddle
for privacy.
Thumb turn and key lock or unlock outside handle.
When outside handle is locked, key retracts latch bolt.
Auxiliary latch deadlocks latch bolt. Outside handle unlocks when inside
handle is turned or door closes and reactivates outside push paddle. Inside
handle always free for egress.
Inside wired push paddle always free for egress.
KEY FUNCTION
The main latch bolt may be momentarily retracted with a key.
ELECTRICAL SPECIFICATIONS
Filtered and Regulated Power Supply.
VOLTAGE: 24VDC (21VDC – 30VDC)
CURRENT: 625 mA MAX Inrush, 150 mA MAX Holding Non-polarized leads.
2 Conductor Wire Run
Distance| Wire Gauge
125’| 22
200’| 20
350’| 18
500’| 16
800’| 14
1250’| 12
ONBOARD INDICATOR LIGHT ASSIGNMENTS
Maintain input power to the mortise lock and check the onboard indicator lights. Remove input power before attempting a solution.
GREEN
(POWER)
| YELLOW
(SENSOR)| RED
(ERROR)| INDICATION| POSSIBLE SOLUTION
---|---|---|---|---
Off| Off| Off| No Power.|
Connect the wiring between the power supply and the mortise lock.
On
| On| Off| Normal Operation. The main latch bolt is retracted to the preset
retracted position. The device is allowed 2 attempts.|
On| Off| On| Error in operation. The main latch bolt did not retract to the
preset retracted position within 2 attempts|
Clear the jam condition manually.
On
| On| On| Error in operation. Without power being removed, the main latch bolt
unintentionally extended from the preset retracted position, and then the main
latch bolt did not retract back to the preset retracted position within 2
attempts.| Clear the jam condition manually.
On| Blink| On| Error in operation. The main latch bolt did not extend from the
preset retracted position when the power was last removed. The device will not
attempt a retraction.|
Clear the jam condition manually.
On
| Simultaneous Blink| Error in operation. The input voltage dropped below the
specification during operation.| Decrease the wire run or increase the wire
gauge.
On| Alternating Blink| Error in operation. An electronics fault was detected.|
An electronics replacement is required.
Mortise lock with Locking Bar (LB) Monitoring.
LB – LOCKING BAR MONITORING
The LB switch monitors the position of the locking bar.
Furnished standard on the M9143ELR.
ELECTRICAL SPECIFICATIONS
SPDT Mechanical Switch
VOLTAGE|
CURRENT
---|---
125 VAC
| 1 AMP
30 VDC|
0.5 AMP
NOTE: Mainly used as a dry contact monitoring switch.
WIRING DIAGRAM
BROWN WIRE – Common
RED WIRE – Open Loop Secure
GREEN WIRE – Closed Loop Secure
CUSTOMERS SUPPORT
1 Annie Place Stamford, CT 06902 I 203.348.8865
www.accuratelockandhardware.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>