AMERICAN CRAFTED SINCE 1972
M8825ELR-LM | M8858ELR-LM | M8859ELRLMOPERATING
INSTRUCTIONS
ACSI M1520M-LM
M8825ELR-LM Mortise Lock With Latch Bolt (LM) Monitoring
Mortise lock with Latch Bolt (LM) Monitoring, also referred to as main latch
or bolt monitoring.
M8800ELR MOTOR DRIVE ELECTRIFIED LATCH RETRACTION
Outside trim (or both outside and inside trim depending on the lock function)
is locked.
The main latch bolt is retracted when power is applied.
The main latch bolt is extended in the event of a power failure.
LM -LATCH BOLT MONITORING
The LM Switch monitors the full extension of the main latch
ELECTRICAL SPECIFICATIONS
SPDT Mechanical Switch
VOLTAGE | CURRENT |
---|---|
125 VAC | 1 AMP |
30 VDC | 0.5 AMP |
NOTE: Mainly used as a dry contact monitoring switch.
WIRING DIAGRAM
BLACK WIRE – Common
RED WIRE – Closed Loop Secure
WHITE WIRE – Open Loop Secure1 Annie