CAL-ROYAL LR100CAK-9800 Electric Latch Retraction Kit Instruction Manual
- June 13, 2024
- CAL-ROYAL
Table of Contents
SDC
INSTALLATION INSTRUCTIONS
LR100CAK-9800
CAL-ROYAL ELECTRIC LATCH RETRACTION KIT
MODELS: GLS9800 & GLSCVR9860
LR100CAK-9800 Electric Latch Retraction Kit
Retrofit Installation Note: 42″ or 48″ exit devices that have been modified to
fit a 36″ or smaller opening, may not have the required space to fit the
standard E. L. R. assembly. Always verify the distance from the end of the
touchpad to the end rail, and if necessary, consult with the factory for
appropriate selection.
Step 1
Remove access cover. Disconnect and discard all dogging components. Then
remove the two pre-existing screws from the device.
Step 2
Slide the ELR assembly into the housing and under the hinge bracket. Position
the roller at the front of the ELR under the pivot arm of the push bar.
Step 3
Once ELR is in place re-fasten the exit device screws and secure the ELR in
place.
Test the unit
Wire the unit and test function. Reinstall the cover (in reverse) and end cap.
When retrofitting to existing vertical rod devices, adjustment of the rods is
required for proper operation of the Electric Latch Retractor. Once the unit
is properly installed, energize it so the latch is dogged down, then reconnect
the vertical rods to the device and make the proper adjustments to the rods
.
Any suggestions or comments to this instruction or product are welcome. Please
contact us through our website or email engineer@sdcsecurity.com
P:\INST INSTRUCTIONS\ELR KITS\INST-LR100CAK-9800
REV B
06-22
SECURITY DOOR CONTROLS
■ WWW.SDCSECURITY.COM
[t] 800.413.8783
■ 805.494.0622
■ E-mail: service@sdcsecurity.com
■ 801 Avenida Acaso, Camarillo, CA 93012
■ PO Box 3670, Camarillo, CA 93011
References