Product Information

The product is the Architectural Series Linear LED Wall Mount, available in three models: 1051, 1052, and 1054. It is designed for direct luminaire mounting to a structural surface over a recessed 4-0 box or a weatherproof outlet box. The luminaire can be mounted in such a way that the direction of illumination can be adjusted up or down. The luminaire throw can also be adjusted up to +/- 15 degrees from horizontal

Product Usage Instructions

Installation over Recessed 4-0 Box:

  1. Before starting the installation or servicing the luminaire, ensure that the electrical supply is turned off at the circuit breaker.
  2. Identify the two un-used mounting holes on the Wall Mount Plate, which will be plugged. Refer to the provided image and step 2 below.
  3. Place the gasket on the Wall Mount Plate.
  4. Insert two washers into the 4-0 box mount holes on the Wall Mount Plate.
  5. Attach two stand-offs to the Wall Mount Plate, hand-tightening them.
  6. Mount the Wall Mount Plate onto the wall, aligning it with the recessed 4-0 box.
  7. Securely tighten the stand-offs using an 8-32 mount screw.
  8. Use the aiming adjustment screw to adjust the direction of illumination as desired.
  9. Lock the aim by tightening the 1050 WM Luminaire Aim Lock Set Screw.

Installation over Weatherproof Outlet Box:

  1. Ensure that the electrical supply is turned off at the circuit breaker before starting the installation or servicing the luminaire.
  2. Mount the luminaire to a standard 4 diameter Weatherproof Outlet Box with a 3-1/2 Bolt Circle Diameter (BCD) using four 10-24 Mounting Screws.
  3. Similar to the previous installation method, the luminaire can be adjusted to illuminate either up or down. The luminaire throw can also be adjusted up to +/- 15 degrees from horizontal.
  4. Use the aiming adjustment screw to adjust the direction of illumination as desired.
  5. Lock the aim by tightening the 1050 WM Luminaire Aim Lock Set Screw.

1051/1052/1054
Architectural Series Linear LED Wall Mount

INSTALLATION INSTRUCTIONS

IMPORTANT NOTE:

  • Luminaire must be installed and grounded in accordance with the National Electrical Code (NEC) and local codes.
  • Luminaire is UL listed for above grade installation only.
  • Always use UL recognized wire connectors for connections.

MAINTENANCE

To assure proper operation and efficiency, lens must be kept clean and free of dirt, dust,leaves, trash and mineral deposits from water. A regular scheduled maintenance program is recommended.

SAFETY WARNING

Luminaire can become hot. Take care when locating luminaires.

NOTE: Save these instructions for future reference.

DIRECT LUMINAIRE MOUNTING TO STRUCTURAL SURFACE OVER RECESSED 4-0 BOX (by others)

  1. Make sure electrical supply is off at circuit breaker before starting luminaire installation or servicing luminaire.
    NOTE: The Luminaire can be mounted such that the direction of illumination will be up or down. The Luminaire throw can be adjusted up to +/- 15 degrees from horizontal.
    NOTE: The Wall Mount Plate has four mounting holes, two of which will be un-used when mounting over a recessed 4-0 BOX. Determine which holes will be un-used and plug them by following the image and step 2 below.

  2. Install two 8-32 Mount Screws (by Vista) through the Wall Mount Plate and 4-0 Gasket, in the two holes to be un-used, and affix with two Washers (by Vista) and 8-32 Hex Stand-Offs (by Vista). Firmly tighten by hand.

  3. Route luminaire Load conductors (by Vista) into recessed 4-0 Box (by others). Using NEC approved wiring methods, attach Supply conductors (by others) to the luminaire Load conductors observing polarity: Supply (+) to Load (black), Supply (-) to Load (White), and Supply (Ground) to Load (Green). If 0-10V dimming is used connect: Dimming Supply (+) to Dimming Load (Purple) & Dimming Supply (-) to Dimming Load (Grey).

  4. Affix the Wall Mount Plate to the 4-0 box using the remaining two 8-32 Mount Screws (by Vista). Tighten.

  5. Adjust the aim of the luminaire, up to +/- 15 degrees from horizontal, and firmly re-tighten the Aiming Adjustment Screw.

  6. Lock the desired aiming of the luminaire by firmly tightening the two Set Screws on both sides of the Wall Mount Plate.

  7. Supply power to the luminaire and check for proper operation.

VISTA-1051-Architectural-Series-Linear-LED-Wall-
Mount-1

IMPORTANT NOTE:

  • Luminaire must be installed and grounded in accordance with the National Electrical Code (NEC) and local codes.
  • Luminaire is UL listed for above grade installation only.
  • Always use UL recognized wire connectors for connections.

MAINTENANCE: To assure proper operation and efficiency, lens must be kept clean and free of dirt, dust,leaves, trash and mineral deposits from water. A regular scheduled maintenance program is recommended.

SAFETY WARNING: Luminaire can become hot. Take care when locating luminaires.

NOTE: Save these instructions for future reference.

DIRECT LUMINAIRE MOUNTING TO STRUCTURAL SURFACE OVER WEATHERPROOF OUTLET BOX (by others)

  1. Make sure electrical supply is off at circuit breaker before starting luminaire installation or servicing luminaire.
    NOTE: The Luminaire can be mounted to a standard 4” diameter Weatherproof Outlet Box with a 3-1/2” Bolt Circle Diameter (BCD) using four 10-24 Mounting Screws.
    NOTE: The Luminaire can be mounted such that the direction of illumination will be up or down. The Luminaire throw can be adjusted up to +/- 15 degrees from horizontal.

  2. Route luminaire Load conductors (by Vista) into Weatherproof Outlet Box (by others). Using NEC approved wiring methods, attach Supply conductors (by others) to the luminaire Load conductors observing polarity: Supply (+) to Load (black), Supply (-) to Load (White), and Supply (Ground) to Load (Green). If 0-10V dimming is used connect: Dimming Supply (+) to Dimming Load (Purple) & Dimming Supply (-) to Dimming Load (Grey).

  3. Affix the Wall Mount Plate to the Weatherproof Outlet Box (by others) using the four 10-24 Mount Screws (by Vista). Tighten.

  4. Adjust the aim of the luminaire, up to +/- 15 degrees from horizontal, and firmly re-tighten the Aiming Adjustment Screw.

  5. Lock the desired aiming of the luminaire by firmly tightening the two Set Screws on both sides of the Wall Mount Plate.

  6. Supply power to the luminaire and check for proper operation.

VISTA-1051-Architectural-Series-Linear-LED-Wall-
Mount-2

Vista Professional Outdoor Lighting reserves the right to modify the design and/or construction of the fixture shown without further notification.

1625 Surveyor Avenue • Simi Valley, CA 93063 • 805-527-0987 • (800) 766-VISTA (8478) • FAX: (888) 670-VISTA (8478) • email@vistapro.comwww.vistapro.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

VISTA User Manuals

Related Manuals