SALTO ECxx….F series NCoder USB Ethernet Connection User Guide
- June 13, 2024
- SALTO
Table of Contents
SALTO ECxx….F series NCoder USB Ethernet Connection User Guide
ECxx…. series
Installation
NCoder MODE
IMPORTANT: The Ethernet connection requires the use of the provided
power supply adapter for a correct product operation
Select desired communication mode, USB (a) or Ethernet (b)
DESKTOP READER MODE
Only with USB communication
To be able to work in Desktop Reader mode, the NCoder must be configured
through the Space software
Electrical characteristics
OPERATING CHARACTERISTICS
| Min| Max| Unit
Temperature| 0| 50| °C
Humidity| 0| 95| %
RF CHARACTERISTICS
| Min| Cen| Max| Unit
RFID frecuency| –| 13.56| –| Mhz
Bluetooth Smart frecuency| 2400c| 2445| 2483.5| Mhz
POWER CONSUMPTION
| Typ.| Max.| Unidad|
USB| 250| 400| mA|
Ethernet| 350| 500| mA|
CABLE REQUIREMENTS
Ethernet| UTP CAT5e
USB| USB 2.0 Male USB A to Male USB B
Configuration
-
The NCoder is a DHCP ready device.
-
It is possible to manually change the IP settings from dynamic to static using a web browser.
-
Connect the NCoder to the PC using an Ethernet cable (not provided).
-
Make sure that the NCoder (v2) has been declared in “SALTO Network” and that the “Online” option is selected in the NCoder options (Admin/local settings).
-
Press the back clear button for 5s to access the addressing mode (see addressing status signaling).
-
Access the 192.168.0.234 IP internal IP address using a web browser.
-
Change the needed parameters and use the “send” option. The NCoder will leave the addressing mode automatically (if no actions are required you can
leave the addresing mode by pressing the CLR button for 5s). -
Click on the back clear button and press “INITIALIZE” (SALTO Network/NCoder).
-
The NCoder is now ready to be used.
USB CONNECTION
- Connect the NCoder to the PC using the provided USB cable.
- Make sure that “local” option is selected in the NCoder options (Admin/local settings).
- Perform any operation against the NCoder (ex. “Read Key”).
- You will get the following warning message
DIPSWITCH SET UP
For future uses
INITIALIZATION ON SPACE
It is necessary that NCoder be in factory mode (factory mode signalling). Press CLR button during 5 seconds and continue the steps described at Space’s user manual.
FATORY RESET
If it is necessary to re-install the NCoder, it is possible to restart it to factory mode. If you connect power supply while pressing CLR button during 5 seconds, the NCoder will return to the same status as when it left the factory.
Maintenance
Dampen a lint-free cloth or cotton swap with alcohol. Gently rub the cloth
back and forth across the sensor. Repeat the process once or twice as needed.
Visually observe that no residual solution remains on the sensor, especially
the edges.
Caution: Harsh and abrasive materials are not recommended for cleaning
sensors. Keep the device in a safe place!
Signalling
SIGNALLING | LIGHT | TIME | BUZZER | TIME |
---|---|---|---|---|
Waiting for key/finger | Blinking green 500/500 | Cont. | Low pitched 500/500 |
Cont.
Key processing| Blinking yellow 50/50| 100 msec| Low pitched 50/50| 100 msec
Successfully processed key/finger| Green| 1 sec| Low pitched| 1 sec
Operation failure| Red| 1 sec| High pitched 50/50| 1 sec
Factory mode| Red| Cont.| No| –
Addressing status| Yellow| Cont| No| –
Waiting for initialization| Blinking red 500/500| Cont.| No| –
Ncoder start up| Green| 1 sec| No| –
DR activation| Yellow 1000 + Green 500| 1,5 sec| Silence 1000 + high pitched
500| 1,5 sec
Finger successfully reading| Blinking green 50/50| 300 msec| Low pitched
50/50| 300 msec
Finger failure reading| Blinking red 100/100| 200 msec| No| –