PRODUCT DESCRIPTION
SALTO Neo cylinder is a battery operated electronic cylinder that brings all the advantages and benefits of an access control without wiring the door reducing installation costs and allowing you to control and manage virtually any kind of door.
The SALTO Neo cylinder is specially designed to fit most doors that are equipped with a mortise lock.
A wire free fully stand-alone electronic access control solution, it is suitable for installation in almost every type of wooden door including antique or listed wooden – metal – metal framed glass doors.
WHATS IN THE BOX
- When you purchase a SALTO Neo electronic cylinder, you get:
- SALTO Neo electronic cylinder
- 4 battery LR1 type
- Installation guide
WARNING: for the maintenance of the cylinder in order to perform
replacement of batteries or the installation of double knob cylinders, SALTO
recommends to purchase the Installation tool (SP225542 – sold separately)
ACCESSORIES
- 2,5mm Allen key for SALTO Neo to remove the thumbturn (SP301585).
- 4 LR1 battery for SALTO Neo cylinders (SP01926-5).
- SALTO Euro cylinder measuring key for installers (PZ) (SP201587).
- Burglar resistant security ring kit to compliant with SSF3522 Grade 4 (SP225865).
WARNING: “The product should not be modified in any way except in accordance with thoseB modifications described in the instructions”.
-
SP301585
-
SP225688
-
SP201587
-
SP226322-IM
SALTO Neo RANGE
MODELS
-
S1 = Scandinavian external cylinder. NxS1xx..
-
S2 = Scandinavian internal cylinder. NxS2xx..
-
S3 = Security Scandinavian external cylinder. NxS3xx..
DIMMENSIONS
-
Standard
-
Knob
-
Scandinavian Cylinder
-
Scandinavian Round Cylinder Profile
CERTIFICATIONS
- CE
- FCC
- IC
- RCM
- MIC
- EN 15684 (1-6-B-3-A-F-3-2)
- IEC 60529 (IP66)
- SSF 3522 Burglar resistance class 4
TECHNICAL DATA
-
CURRENT REQUIRED 4 x LR1 batteries.
-
ENVIRONMENTAL CONDITIONS : -20 C / +55 C (without condensation).
- 35 ºC / +55 ºC (exterior, only MIFARE).
() Battery life reduced significantly.
- 35 ºC / +55 ºC (exterior, only MIFARE).
-
NUMBER OF OPENINGS: up to 130,000 (100,000 with BLE (3)) at 25C.
-
ACCESS CONTROL SYSTEM:
- RW System.
- SALTO KS System.
ACCES CONTROL FEATURES
| RW System| SALTO KS System
---|---|---
Maximum number of users per door| 4,000,000| 1000 for IQ1
10000 for IQ2
Maximum number of door per system| 65,000| Unlimited
Maximum events on lock audit| 2,200| 1462 (BLUEnet) 472 (RFnet)
Time zones| 1,024|
Time periods| 256|
Calendars in system| 256| 128
User groups| Unlimited| Unlimited Unlimited
Management software| ProAccess SPACE ProAccess & HAMS (available SQL)| SALTO
KS
SYSTEMS| SMILE| SALTO Neo
---|---|---
ROM| –
SVN| –
SALLIS|
RADIO TECHNOLOGY| KS| –
RFID|
BLE|
KEYS| TAGS/CARDS| ****
MOVIL – JustIn JustIN NFCJustIN BLE|
CONNECTIVITY| BLUENet|
SPECIAL FUNCTIONS| SVN-Flex|
OPENING MODELS
- STANDARD: locked at all times.
- OFFICE: Free passage ability.
- TIMED OFFICE: free passage with automatic locking.
- AUTOMATIC OPENING: 8 pairs of “hands free” timed lock and unlocks per day with holidays.
- AUTOMATIC OPENING + OFFICE.
- TOOGLE: present card to lock, present card to unlock.
- TIME TOOGLE: present car to lock, present card to unlock depending on schedules.
- TWO PERSON RULE: present two valid cards to unlock.
OPERATION OF THE CYLINDER
-
Present a valid card
-
Turn the knob to retrieve the latch and deadbolt
TIMEZONES
Each user can be assigned to a calendar and a time table consists of up to 8
different time intervals with a resolution of 10 minutes assigned to each day
of the week. You can also distinguish between holidays, special days and
working days.
EVENT AUDITOR
- Authorized access events auditor registration, denied access events auditor registration, system maintenance events auditor registration (low battery, PPD connection,…) and automatic actions events auditor registration (automatic opening…).
- Each events is logged: event type, user, date and time of the event.
- Permanent events registration. Non-volatile memory of the last X events (see table).
INSTALLATION
To install the SALTO Neo cylinder: following the instructions attached
with\ the product, or visiting our website:
www.saltosystems.com/en/quick-links/manuals-and-
guides/
PROGRAMMING
To grant or deny access permissions are used to the right SW license. Once you
update the system configuration:
- RW SYSTEM: the system allows electronic cylinders to read, receive and write information via its operating smart cards or “intelligent keys”. This data is captured from the cards at SVN on-line hot spots located at strategic points around the building. The “online points” uploads and downloads user related information that is then used to permit, control or deny access.
- KS SYSTEM: the system allows electronic cylinders to read, receive and write information via radio SALTO KS.
BATTERIES
In the case of complete battery failure the product both safe and secure, i.e.
the outside handle fails “locked” to avoid intrusions, the inside handle fails
“open” to permit emergency openings.
WARNING: electronic cylinder in standalone or offline mode needs to be update with the PPD to recover the hour. “The product should not be modified in any way except in accordance with those modifications described in the instructions”.
SALTO just warrantee the correct and best autonomy with Alkaline LR1 Energivm – batteries (SP01926-5)
SALTO Neo SIGNALS
ACCESS GRANTED
Present a valid user key and get the access granted
|
---|---
1 High pitched beep| 1 Green light
ACCESS DENIED
Present a not valid user key and get the access denied.
|
---|---
2 Short low pitched beeps| 2 Red lights
LOW BATTERY STATUS
After presenting a valid user card that has access to the door and opening the
door, the cylinder will show 4 light red signal and then grant the access.
|
---|---
4 Short low pitched beeps| 4 Red lights
BATTERY CHANGE (RESET)
Each time you change the batteries, the electronic will do a reset. The
cylinder memory will not be erased. Toshow this reset, the cylinder show
yellow lights with a lite sound.
|
---|---
3 Short low pitched beeps| 3 Yellow lights
OFFICE MODE NOTICE
Present a valid user key, the cylinder show a green ligth with a lite sound.
The cylinder is in “office mode”.
|
---|---
1 High pitched beep| 1 Green light
ACCESS GRANTED IN OFFICE MODE
Present a valid user key, the cylinder show 3 green ligths with a lite sound
and get the access granted.
|
---|---
3 Short high pitched beeps| 3 Green lights
ACCESS DENIED IN OFFICE MODE
Present a not valid user key, the cylinder show red ligths with a lite sound
and get the access denied.
|
---|---
6 Short high pitched beeps| 6 Red lights
OFFICE MODE END
Present a valid user key, the cylinder show 2 red ligths with a lite sound.
The “office mode” is over.
|
---|---
2 Short low pitched beeps| 2 Red lights
ACCESS GRANTED + TOOGLE
After presenting a valid user card with “TOOGLE” credentials, the SALTO Neo
cylinder will start the “TOOGLE” mode. This will be shown by 3 green lights
and high pitched beeps.
|
---|---
3 Short low pitched beeps| 3 Green lights
”
END TOOGLE
After presenting a valid user card with “TOOGLE” credentials, the SALTO Neo
cylinder will end the “TOOGLE” mode. This will be shown by 2 red lights and
low pitched beeps.
|
---|---
2 Short low pitched beeps| 2 Red lights
SECURITY ERROR
When the cylinder shows continuous blinking light Finished and a combination
of high and low pitched beeps and yellow lights, it means that the knob and
the cylinder are not paired and they can not be mounted together.
|
---|---
Short / low pitched beeps| Yellow lights
Learn more about innovativen SALTO access control technologies through this QR
Code using your smartphone to link to the SALTO website
CONFIDENTIAL – This document contains confidential and privileged information. The reproduction of any part of the document is strictly prohibited without the prior written consent of SALTO Systems S.L. – © SALTO Systems 2019 SALTO reserves the rights to modify technical specifications, designs and performance without notice
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>