RAB LIGHTING FWAFER4 Fire Resistant Wafer Downlight FA Instructions
- June 13, 2024
- RAB Lighting
Table of Contents
- RAB LIGHTING FWAFER4 Fire Resistant Wafer Downlight FA Instructions
- INSTRUCTIONS
- IMPORTANT
- WHAT’S IN THE BOX
- TOOLS NEEDED
- OPTIONAL ACCESSORIES (sold separately)
- EXTCBL-FA-6
- EXTCBL-FA-12
- EXTCBL-FA-20
- INSTALLATION INSTRUCTIONS
- Read More About This Manual & Download PDF:
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
RAB LIGHTING FWAFER4 Fire Resistant Wafer Downlight FA Instructions
INSTRUCTIONS
Fire-Resistant Wafer Downlight FA
FWAFER4
FWAFER6
FWAFER4B
FWAFER6B
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE
REFERENCE.
RAB fixture must be wired in accordance with the National Electrical Code and
all applicable local codes. Proper grounding is required for safety.
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION
CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT
AND THE HAZARDS INVOLVED. TO PREVENT ELECTRICAL SHOCK, POWER SHOULD BE TURNED
OFF AT THE FUSE BOX BEFORE INSTALLATION. SAFETY WARNINGS: Read all product
labels and directions.
WARNING – Risk of fire or electric shock. Install this kit only in the
luminaires that have the construction features and dimensions shown in the
photographs and/or drawings and where the input rating of the retrofit kit
does not exceed the input rating of the luminaire.
- Installation should be performed only by a qualified electrician in accordance with the National Electrical Code and relevant local codes. Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
- WARNING – To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. • INSTALLATION SHOULD ONLY BE PERFORMED AFTER POWER TO THE FIXTURE HAS BEEN DISCONNECTED.
- These instructions shall be included on an information sheet packaged with each unit.
- This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
WHAT’S IN THE BOX
TOOLS NEEDED
This fire-resistant wafer requires very few tools for installation. A screwdriver and a pair of wirecutters will help to install.
OPTIONAL ACCESSORIES (sold separately)
EXTCBL-FA-6
Wafer extension cable 6ft
EXTCBL-FA-12
Wafer extension cable 12ft
EXTCBL-FA-20
Wafer extension cable 20f
INSTALLATION INSTRUCTIONS
-
Turn power OFF from the electrical panel before installation.
-
Use template inside box to cut hole in ceiling. (Fig.1)
-
Open the driver box and remove the knockout(s). (Fig.2)
-
Insert the electrical supply cable through the knockout andblack – black, green – green/ground. secure with a terminal. Wire driver box (Fig.3) , white-white
-
Place all wiring and connections back into the box, close the cover and select desired CCT. (Fig.4)
-
Place the driver box into the ceiling and connect the fixture to driver box. (Fig.S)
-
Lifting both retention tabs upward. Push until the trim sits flush against the ceiling. (Fig.6)
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.
Read More About This Manual & Download PDF:
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>