eta 970790000 Sonic Toothbrush User Manual

June 13, 2024
ETA

eta 970790000 Sonic Toothbrush

INSTRUCTIONS FOR USE
Dear customer, thank you for purchasing our product. Please read the operating instructions carefully before putting the appliance into operation and keep these instructions including the warranty, the receipt and, if possible, the box with the internal packing.

GENERAL SAFETY INSTRUCTIONS

  • Consider the instructions for use as a part of the appliance and pass them on to any other user of the appliance.

  • This product is not intended for children under 3. Children at the age of 3 to 14 and persons with limited physical, sensory or mental capabilities may only use the toothbrush if they are supervised or have been instructed of the use of the appliance in a safe manner and understand possible risks. Children must not play with the appliance. Children must not perform cleaning and maintenance intended to be performed by users, unless they are older than 8 years and are under supervision. Children under 8 years of age must be kept of out reach of the appliance and its charging base.

  • If the charging base or its power cord is damaged, it must be replaced by the manufacturer, its service technician or a person with similar qualification, to prevent occurrence of hazardous situation.

  • The connected charging base must not be used at the places where it could fall in bathtub, sink or swimming pool. If it falls into water yet, do not take it out! First disconnect the appliance from the electrical socket, and then take it out from water. In such cases bring the application to the repair shop to verify its safety and correct functions.

  • Never use the appliance if the charging base, power cord or plug is damaged, if it operates incorrectly, fell on ground or is damaged, or if the charging base fell into water.
    In such cases bring the appliance to the specialised repair shop to verify its safety and correct functionality.

  • The appliance has no charging source of its own, it is only designed for charging via USB (an adapter with USB output, with output voltage of 5.0 V, and output current of at least 800 mA). Before making any connection, please pay attention to instructions of the manufacturer of the respective power source.

  • If the appliance is used in a bathroom, it must be disconnected from the mains after use by unplugging the power cord from the wall socket, because the appliance poses a risk if near to water, even when switched off.

  • For additional protection we recommend installing a protective switch (RCD) in the electrical circuitry of the bathroom, with the nominal actuating current not exceeding 30 mA. Ask an inspecting technician or an electrician for advice.

  • To power the appliance, only apply safe small voltage in accordance with the type plate.

  • The appliance is only intended for individual use at home for personal oral cavity care! It is not intended for commercial use, for more than one patient in dentist’s consulting rooms or in any other healthcare facilities!

  • The charging base provided with appliance is only designated for this appliance. Do not use it for other purposes. Only use the provided charging base for this appliance, do not use other types of charging base for recharging (for example from other appliance).

  • Do not use the application in exterior or where aerosol products are used (such as sprays), or where oxygen is handled.

  • Do not plug or unplug the charging base power cord to/from the adapter with wet hands!

  • Never immerse the charging base in water or other liquids (not even partially) and do not wash it under running water!

  • Do not insert the appliance or its accessories in any body cavities, except for oral cavity.

  • Only use the charging base at horizontal position at places where overturning is not imminent, and in a sufficient distance from heat sources (such as stove, fireplace, or heat radiators).

  • Clean the accessories after each use. Failure to adhere to this instruction might cause worsening your state of health, because without disinfection, spread of mildew and bacteria is supported.

  • Charge the accumulator at the normal room temperature. Do not expose the accumulator to temperatures higher than 50 °C to prevent causing damage to the accumulator.

  • Do not use the charging base during bathing.

  • This appliance contains batteries that are not replaceable. Only remove the accumulator if the appliance is to be discarded (see article V. ECOLOGY). Effective capacity gradually decreases depending on the method of use of the accumulator.

  • The appliance is not designed to care for animal teeth.

  • Do not leave the appliance unattended!

  • Protect the appliance from dust, chemicals, toiletries, liquid cosmetics, large fluctuations in temperature, and direct sunshine.

  • Do not attempt to repair the appliance by yourselves.

SPECIAL SAFETY INSTRUCTIONS

  • If you have unpleasant feeling in your mouth or if you feel pain during the cleaning, stop using the appliance and contact your dentist. Contact the dentist also in the case that you have any doubt about use of the appliance in your individual case.
  • If your toothpaste contains peroxide, baking soda or other bicarbonate (frequently used in whitening toothpastes), thoroughly clean the brush and  its handle after use to prevent damaging the appliance.
  • Do not use the appliance in care for children, incapacitated persons or persons who are unable to express their feelings.
  • If you have undergone tooth or gum operation recently, suffered long-term problems with your teeth or were subject to extensive medical interventions in the last 2 months, or if you suspect problems of dental character (with fillings, crowns, etc.), consult your dentist before using the appliance.
  • If you experience any health troubles (for example considerable bleeding, or if any bleeding persists even after 2 weeks of use of the brush), stop using the appliance and contact your physician for consultation.
  • The appliance complies with the safety standards for electromagnetic radiation. However if you use any of the following devices: cardiostimulator, electrocardiograph or other medical device implanted in your body or used as a support, consult your physician or the implant manufacturer before use.
  • For hygienic reasons do not share the toothbrush with another person or more persons. Infections could spread or oral cavity inflammation could be initiated.
  • If you need to use an extension cord, it has to be uncorrupted and it has to comply with the valid standards
  • The charging base power cord must not be damaged by sharp or hot items or open flam, and they must not be immersed in water or bent over sharp edges. They must not freely hang over the desktop edge within reach of children..
  • Regularly check the condition of the charging base power cord.
  • Only use this appliance including its accessories for the designated purpose as described in this instruction manual. The appliance is only designed for cleaning teeth, gums and tongue. Never use the appliance for any other purpose.
  • Only use the appliance with the original accessories designated for the respective type. Do not use damaged/deformed adapters.
  • WARNING: There is a risk of injury in case of incorrect use (not in accordance with the manual) of the appliance.
  • All text in other languages and pictures shown on the packaging, or the product itself, are translated and explained at the end of this language mutation.
  • The producer does not undertake any responsibility for damage caused by improper use of the appliance (e.g. injury etc.) and its guarantee does not cover the appliance in the case of failure to comply with the safety warning above. This appliance is not intended as a substitute for medical care.

DESCRIPTION OF FEATURES (FIG. 1)

A – Brush body
A1 – ON/OFF switch + mode switch (POWER; ON/OFF)

A2 – active mode indicator
A3 – battery indicator light
A4 – pressure sensor lamp (Light Ring)

B – Brush (2 pieces included)
B1 – brush head B2 – coloured ring to distinguish users

C – Charging base
C1 – power cable USB: Use AC power adapter with USB or mobile power.

D – Protective travel case
Note: Replacement brushes (B) can be purchased under order number ETA 070790100; ETA 070790200; ETA 070790300, ETA 070790400, ETA 070790500 and ETA 070790600

INSTRUCTIONS FOR USE

Remove all packaging materials and take out the appliance and any accessories. Parts which come in contact with the oral cavity must be rinsed in warm drinking water before first use.

CHARGING THE BRUSH (Fig. 2)
This appliance is equipped with a contactless (induction) charging system which works on the principle of energy transfer through an electromagnetic field. No direct connection with the power cable is required which makes charging more convenient and thanks to the enhanced insulation (IPX7) also safer. Connect the charging base (USB cable (C1) into the charge slot compatible AC wall adapter or mobile power) first and place the brush body (A) onto the cylindrical projection in the charging base (C). The charging procedure is signalled by a flashing (A3) LED indicator. When the battery is fully charged, the (A3) LED indicator is lit. Unplug the adaptor from the wall socket first and only then unplug the connector USB. For a full charge, the battery needs to be charged for approximately 12 hours. Depending on the cleaning mode used, a fully charged battery will provide approximately 2-2.5 hours of operation which corresponds to about 1-2 months when used twice a day for two minutes.

Note: Although the brush should not be charged before it is fully discharged, we recommend charging it at regular intervals (e.g. after 2-3 weeks of use) in order to ensure optimum battery life.

Caution

  • During operation, the (A3) LED indicator is not lit, when the battery of the accumulator is low and it needs to be recharged, the LED indicator starts flashing.
  • Do not exceed the recommended time of charging (12 hours) during regular charging!
  • The charging base also serves as a stand where you can place the brush after use. However, do not connect the base to the AC wall adapter unless you wish to charge the brush. Do not leave the charging base connected to the AC wall adapter permanently!
  • The appliance warms up during charging, but this is normal and not a defect.
  • The operating time is only approximate. The time depends on the condition of the battery, ambient temperature, age, method of charging, etc.
  • To power the appliance, use only a safe low voltage source of 5 V DC in accordance with the applicable standards (a mobile phone charger with a USB connector in double insulation is suitable), which is capable of giving a current of at least 800 mA or more. (Note: the specified current load is minimal, it can be higher).
  • Do not use USB ports on other devices (e.g. computer, laptop, tablet, mobile phone, etc.) to power the appliance. These devices do not have to be designed for current consumption of the appliance and could be damaged.

USE

Before use, slide the brush (B) onto the brush body (A) to connect them (See Fig. 1).

A small gap will remain between the brush body (A) and the coloured ring (B2) which is not a defect. To remove the brush, proceed the other way round. Do not switch on the appliance without the brush attached! Moisten the brush and apply a small amount of toothpaste on it. Put the brush to the teeth at a slight angle towards the gums (see Fig. 3) and switch on any mode by pressing the mode on/switch button (A1). Move the brush slowly along the teeth back and forth, applying a slight pressure, so as not to miss any tooth or area in the mouth. Clean each tooth for about 2-3 seconds.

The brush operating time is limited to 2 minutes which corresponds to the time for cleaning recommended by experts. If you wish to continue cleaning, simply switch on the brush again. Each part of the mouth (quadrant) should be cleaned for about 30 seconds (see Fig. 4). A short interruption of the brush operation will prompt you to move to another quadrant after this time elapses.

Pressure sensor
If you put excessive pressure on your teeth, the toothbrush will provide immediate feedback the pressure sensor lamp (A4) will light up in red and change in vibration (and a slight change in sound) to indicate that you need to reduce the pressure. Periodically check the operation of the pressure sensor by pressing moderately on the brush head during use.

Notes

  • If this is your first sonic toothbrush and you have not had any experience with this cleaning technology, it might take you a while to get used to the specific vibration (tingling). However, most users say that they got used to it quickly after a few uses and cleaning became perfectly natural for them.
  • Do not apply excessive pressure on your teeth.
  • You can also use this brush when you have fixed braces, facets, crowns, etc. However, please bear in mind that if the brush is used with braces, the brush bristles are subject to more wear.
  • We recommend that you replace the brush (B) with a new one after 3 months of use. However, if the brush is showing signs of significant wear or damage.

Mode on/switch button control A1
When you press the button once, the brush switches on in mode C. If you press the button again within 3 seconds, the brush will switch to mode S. If you press the button repeatedly within 3 seconds, the brush will switch to mode W, etc. When you press the button again, the brush will switch off. The brush will also switch off if you press the button (A1) in mode C/S/W/M/P after 5 seconds after its activation.

Cleaning modes

eta 970790000 Sonic Toothbrush 1

Activation of the mode selected is indicated by the indicator (A2) coming on.

CLEANING AND MAINTENANCE

Before performing maintenance of the charging base (C), unplug it from the mains first! For maximum hygiene, clean the brush (B) after each use!
Rinse the brush head (B1) and the brush body (A) under running water and wipe (Fig. 5) the brush body with a damp cloth. Use the damp cloth to wipe the charging base and its cable as well. Never immerse the brush body (A) or the charging base (C) in water! Do not use a dishwasher for cleaning! Allow the brush body (A), the charging base (C) and the cable to dry properly before re- use. Store the appliance and all the accessories in a dry, dust-free and safe place, out of reach of children and incapacitated persons. Transport case (D) is designed for safe depositing of the appliance and its accessories.

ENVIRONMENTAL PROTECTION

If the dimensions allow, there are labels of materials used for production of packing, components and accessories as well as their recycling on all parts. The symbols specified on the product or in the accompanying documentation mean that the used electrical or electronic products must not be disposed of together with municipal waste. For proper disposal of the product, hand it over at special collection places where it will be taken over free of charge. Suitable disposal of the product can help to maintain valuable natural resources and to prevent possible negative impacts on the environment and human health, which could be the possible consequences of improper waste disposal. Fines can be imposed for improper disposal of this type of waste in agreement with the national regulations. This appliance is equipped with a Li- ion battery with long life.

For environmental protection it is necessary to remove the battery from the appliance after its service life and the battery and the appliance must be disposed of safely using special collection networks. Ask for more details at the local authority or at the local waste collection site.

Removing the battery
Remove the battery from the appliance only when completely discharged. The procedure for removing the battery is shown in Fig. 6:

  1. Using a screw-driver, remove the screw cover and loosen the screw.
  2. Hold the brush body (A) upside down, press the charging part (see arrows in the figure) and remove the 2 hooks which hold the inner components of the brush body (A).
  3. Remove the battery from the compartment using a screw-driver.

TECHNICAL DATA

  • Voltage (V) shown on the type label of the appliance
  • Weight (kg) approximately 0.18
  • Appliance/Adapter Protection Class III. / II.
  • Size, (mm): 250 x 28 x 29

The manufacturer reserves the right to change the technical specifications and accessories for the respective models. Expert service must do the large maintenance or to intervene into inside parts of the appliance! Non-observance of the instructions of the manufacturer cancels the right for guarantee repair!

WARNINGS AND SYMBOLS USED ON THE APPLIANCE, PACKAGING OR IN THE INSTRUCTIONS MANUAL:
HOUSEHOLD USE ONLY; DO NOT IMMERSE IN WATER OR OTHER LIQUIDS;

TO AVOID DANGER OF SUFFOCATION, KEEP THIS PLASTIC BAG AWAY FROM BABIES AND CHILDREN. DO NOT USE THIS BAG IN CRIBS, BEDS, CARRIAGES OR PLAYPENS. THIS BAG IS NOT A TOY.

eta 970790000 Sonic Toothbrush 2

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals