B D Australia Power Drive Rolling Door Opener Instruction Manual
- June 13, 2024
- B D Australia
Table of Contents
- B D Australia Power Drive Rolling Door Opener
- Product Information: Rolling Door Opener
- Product Usage Instructions:
- Installation Safety Warnings!
- Kit Contents
- Tools Required
- Setup Requirements
- Door Preparation
- Fit the Weight Bar
- Pinning the Door
- Proping the Door
- Mounting the Opener
- Setting the Travel Limits
- Safety Testing
- Accessories
- Auto-Close (CAD PD Only)
- 14. Coding a Transmitter
- Coding a Transmitter
- Home Owner Safety Warnings
- Opener Safety & Security
- Operating your Opener
- User Operating Controls
- Door Status Indicators
- Troubleshooting
- After Installation Care
- After Care Installation
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
B D Australia Power Drive Rolling Door Opener
Product Information: Rolling Door Opener
The Rolling Door Opener is an automatic garage door opener designed to provide safe and convenient operation. It comes with various installation and setup instructions to ensure proper functionality. The opener is equipped with safety features such as obstruction sensing and auto close mode, and it can be integrated with accessories like auxiliary outputs, keyswitches, and remote aerials.
Product Usage Instructions:
- Installation Safety Warnings: Before proceeding with the installation, it is crucial to read and follow all safety warnings provided in the user manual. Failure to do so may result in severe injury or property damage.
- Kit Contents: Check the kit contents to ensure all necessary components are included.
- Tools Required: Gather the tools required for installation as listed in the user manual.
- Setup Requirements: Familiarize yourself with the setup requirements before proceeding with the installation process.
- Door Preparation: Follow the instructions to prepare the door for installation.
- Fit the Weight Bar: Install the weight bar as instructed to ensure proper functioning of the opener.
- Pinning the Door: Securely pin the door according to the provided guidelines.
- Proping the Door: Properly prop the door in place for mounting the opener.
- Mounting the Opener: Mount the opener on the designated location using the recommended installation procedure.
- Setting the Travel Limits: Follow the step-by-step instructions to set the travel limits of the opener.
- Safety Testing: Perform safety tests to ensure the proper functioning of the opener, including close cycle test, open cycle test, and manual door operation test.
- Adjusting Safety Obstruction Force: Adjust the safety obstruction force as required using the provided instructions.
- Accessories: Learn about the various accessories that can be integrated with the opener, such as auxiliary outputs, keyswitches, and remote aerials.
- Coding a Transmitter: Follow the coding instructions to program and store transmitter codes.
- Home Owner Instructions: Read the safety warnings and instructions specifically provided for home owners.
- Opener Safety & Security: Understand the conditions under which the opener can and cannot be used, and learn how to disengage and re-engage the opener.
- Operating your Opener: Learn how to operate the opener using the user operating controls.
- Door Status Indicators: Familiarize yourself with the door status indicators to monitor the current state of the door.
- Specifications: Refer to the specifications section for detailed technical information about the opener.
- Troubleshooting: Troubleshoot any issues that may arise during or after installation using the troubleshooting guidelines provided.
- After Installation Care: Follow the recommended care instructions to ensure optimal performance and longevity of the opener.
- Warranty: Review the warranty information provided for details on coverage and claim procedures.
It is important to note that the Rolling Door Opener should be installed by professional garage door opener installers. For any technical assistance or maintenance, it is recommended to contact the manufacturer’s service agent or a suitably qualified person.
Ensure that all safety precautions are followed during installation and operation to avoid accidents or injuries. Regular testing and maintenance of the opener are also advised for continued safe and reliable performance.
Installation Safety Warnings!
This automatic garage door opener is designed and tested to offer safe service provided it is installed and operated in strict accordance with the following safety warnings. Failure to comply with the following instructions may result in death, serious personal injury or property damage.
WARNING
- The door may operate unexpectedly, therefore do not allow anything to stay in the path of the door.
- When operating the manual release while the door is open, the door may fall rapidly due to weak or broken springs, or due to being improperly balanced.
- The drive must not be used with a door incorporating a wicket door, unless the drive cannot be operated with the wicket door open.
- The drive is intended to be installed at least 2.5m above the floor.
- Do not disengage the opener to manual operation with children/persons or any objects including motor vehicles within the doorway.
- If the door is closing and is unable to re-open when obstructed, discontinue use. Do not use a door with faulty obstruction sensing
- When using auto close mode, a Photo Electric beam must be fitted correctly and tested for operation at regular intervals. Extreme caution is recommended when using auto close mode. All safety rules must be followed.
ELECTROCUTION
- Place opener in protected area so that it does not get wet.|
- Do not spray with water .
- Disconnect the power cord from mains power before making any repairs or removing covers. Only experienced service personnel should remove covers from the opener.
- If the power supply cord is damaged, it must be replaced by an Automatic Technology service agent or suitably qualified person.
- Connect the opener to a properly earthed general purpose 240V mains power outlet installed by a qualified electrical contractor.
CAUTION
Emergency Access
- If garage has no pedestrian entrance door, an emergency access device should be installed. This accessory allows manual operation of the garage door from outside in case of power failure.
Muscular strain
- Practice correct lifting techniques (carton weighs approx 9kgs)
- Practice correct lifiting techniques when required to lift the door as per installation instructions.
Fall from ladder
- Ensure ladder is the correct type for job.
- Ensure ladder is on flat firm ground that will take the weight without the legs sinking.
- Ensure user has 3 points of contact while on ladder.
Crush injury from unsecured door
- Place a 2 metre exclusion zone around area under the door while it is unsecured.
- Do not move under a door while it is on the door support (or ladder)
- Follow the installation instructions
- Fit door support (or ladder) snugly under door before removing bracket.
- Ensure door support (or ladder) is on flat ground
Garage Door
- Examine the door installation, in particular, springs and mountings for signs of wear, damage and imbalance.
- The garage door must be well balanced. Sticking or binding doors must be repaired by a qualified garage door installer prior to installation of the opener.
- Remove or disengage all garage door locks and mechanisms prior to installation of the opener.
Entanglement
- Never plug in and operate opener prior to installation.
- Keep hands and loose clothing clear of door and guides at all times.
Entrapment under operating door
- DO NOT operate the opener unless the garage door is in full view and free from objects such as cars and children/people. Make sure that the door has finished moving before entering or leaving the garage
- In order for the opener to sense an object obstructing the door way, some force must be exerted on the object. As a result the object, door and/or person may suffer minor damage or injury.
- Ensure the garage door is in good working order by undertaking regular servicing.
- Install the optional wall transmitter in a location where the garage door is visible, but out of the reach of children at a height of at least 1.5m.
- Photo Electric beams must be installed if the closing force at the bottom edge of the door exceeds 400N (40kg)
Kit Contents
-
Power Drive 1 x RDO-1V4 drive unit Roll-A-ProTM 1 x RDO-1V3 drive unit
-
2 x Locking Bar Covers
-
Power Drive 2 x TB-6 Transmitters
- 1 x Wall Mount Transmitter
- Roll-A-ProTM 3 x TB-5 Transmitters
- 1 x Wall / Visor Clip
-
1 x Collar Kit
-
1 x Weight Bar
Fastner Bag -
2 x Nilock Nut
-
2 x 2 x 3/16 x 1/2 flat washers
-
2 x Pan Head Screw M4 x 50
-
2 x Self Tapping Screw M10 x 32
-
2 x Washer 6.4 x 20.6 x 1.2 GAL Accessory Pack
-
2 x Extension Fork
-
2 x Flat Washer 107D 6.4 x 20.5 x 1.6
-
2 x Hex Serration Head Screw M6 x 45
Tools Required
Setup Requirements
The Opener:
- MUST BE installed in a dry position, protected from weather. (Moisture or corrosion not covered by Warranty)
- Is factory set for RIGHT HAND SIDE installation (from inside garage), but capable of LEFT HAND SIDE installation.
- REQUIRES properly earthed 3 pin single phase power within an arms length of door and at a suitable height
- Requires a MINIMUM SIDEROOM of 41mm from the edge of the door to the inside of the door bracket and 85mm to the wall.
- CAN NOT be installed on a Door Axle Diameter that exceeds 35mm.
WARNING! A portable power generator is not recommended due to spikes, surges and fluctuations in the supply.
Unsuitable Door Types
The drive must not be used with a door incorporating a wicket door, unless the
drive cannot be operated with the wicket door open. The fitting of an opener
to doors with removable mullions is not recommended.
Sideroom
The minimum sideroom required from the edge of the door curtain is 41mm to the
inside of the door bracket, and 85mm to the wall. If a Battery Backup is to be
fitted, at least 135mm to the bracket is required.
Therefore the recommended sideroom from the edge of the door curtain is 95mm
to the inside of the door bracket, and 135mm to the wall as per diagram.
Door Preparation
Prepare the Door
- Clean the guides if there is any oil or wax present using a suitable white spirit. The only lubricant suitable for use on door guides is silicon spray. DO NOT use WD-40, RP-7, petroleum grease, or similar.
- Remove the locking bars or disable the lock.
- Install the locking bar covers 2 if there are locking bar holes in the guides. This ensures fingers cannot be placed in the holes while the door operates
- Affix the supplied warning labels where they are clearly visible on the inside of the door.
- Install the collar kit 4 to the OPPOSITE end to where the opener is being installed.
- Fit the collar kit hard up against the drum.
Fit the Weight Bar
If the door has a handle a weight bar must be fitted to ensure the door doesn’t balloon during operation
- Remove the door handle
- Fit the weight bar 5 and refit the handle using the two (2) M4x50mm Pan Head Screw 8 and the two (2) Flat Washer 7 and the two (2) M4 Nilock Hex nut 6 .
If the door does not have a handle
- Locate the centre of the door at the bottom rail.
- Place the weight bar at this point and mark the two positions where the fasteners will go
- Drill the two 4.5mm holes in the door and fit the weight bar 5 using the two (2) M4x50mm Pan Head Screw 8 and the two (2) Flat Washer 7 and the two (2) M4 Nilock Hex nut 6 .
- Check that the door is still balanced and smooth. If not, then the door may require servicing.
WARNING! To reduce the risk of damage to persons or property, be sure to cut off any excess thread of the screw that protrudes the weight bottle and file any burs.
Pinning the Door
Pinning the Door to the drum
Pinning the door’s curtain to its drum maintains security when the opener is
closed. If the curtain is not pinned the door can be partially opened
manually.
- Fully close the door.
- Mark a minimum of two (2) drill holes on the drum to each end of the door.
- Drill holes using 3.2mm (1/8”) drill bit.
- Fit M10 x 32mm screws and washers to each of the four (4) holes. This screw should be positioned as low as possible in the grove, but make sure that it does not alter the curtain’s normal lead in to the guide.
WARNING! It is the installers responsibility to choose a fastener length that will adequately secure the curtain to the drum.
Proping the Door
Prepare the Door
-
At the end opposite to where the opener will be fitted, check that the U- bolt which holds the door axle to the bracket is tightened securely.
WARNING! The U-bolt must be done up tightly to ensure the stored energy in the springs cannot be unexpectedly released. -
Open the door completely and tie rope around the door roll. Do not tie the rope too tight as damage to the curtain may ensue. This will stop the door unrolling when taken off the bracket
-
At the end where the opener is to be fitted, support the door with a door stand or suitable prop. Place a towel between the door and the prop to protect the door from damage.
WARNING! Make sure the prop is snug under the door and is stable. -
At the end where the opener will be fitted use a pencil to mark the position of the U-bolt in the door bracket and the position of the door bracket on the wall to assist in reassembling.
Mounting the Opener
Raising the Door
- When in position, remove the U-bolt (or bolts) and saddle from the door bracket.
- Lift the door up and away from the wall until clear of the door bracket, before lowering the door to rest on the door stand or prop.
NOTE: If there is limited ceiling space to lift the door, the door bracket may have to be removed. If this is required, when refitting the door bracket , use the reference marks on the wall for correct position and ensure that it is secure to the wall and will support the door.
Mounting the Opener
- Remove the opener from the box.
- Insert the two (2) Extension forks 11 into the ring gear.
- Secure with two (2) Flat washers 12 and two (2) Hex serration head screws 13 .
- Check the drive gear rotates freely, by pulling the string handle down (there will be a click) to disengage opener. Then move the forks from side to side by hand.
- Slide the opener over the door axle and into the drum of the door as shown.
- Push the opener in as far as possible (without interfering with the curtain) so one of the door drum’s wheel spokes is between the opener’s drive forks.
- Raise the door off the door stand or suitable prop.
- Lift up and over the door bracket and use your reference marks on the door bracket to position the door.
- Refit the U-bolt and nuts and tighten.
- Remove the safety rope and door stand or prop.
- Connect the power cort to a suitable powerpoint, but DO NOT switch on.
- Secure the power cord away from any moving object (e.g the door) with the cable clip supplied. m. With the opener still disengaged, pull the door up and down to make sure it runs freely.
WARNING! For tight sideroom installations the door may have to be taken down.
Setting the Travel Limits
Initial Preparation
- Move the door to the half way position.
- Remove the clear button cover from the unit.
- Engage the opener by pulling down on the manual release string until a click sounds.
- Switch power on to the opener. The red CLOSE LIMIT LED will be flashing.
- Press and hold the MINUS (-) button – the door should start closing.
NOTE: If the door opens, release the MINUS (-) button and press the OPERATE button once to change the motor’s direction.
WARNING! In setting the close limit position, do not force the door into the floor with excessive force, as this can interfere with the ease of operation of the manual release mechanism.
Set the Limit Positions
The Limit Positions can vary due to site conditions, such as uneven ground.
When setting the Close limits, ensure the position is when the door makes
first contact with the ground. Alternatively for the Open limits the position
should be at the height of the garage opening.
- Press and hold MINUS (-) button until the door reaches your desired close limit position. The rubber strip at the bottom of the door should form a good seal with the ground.
- Release the MINUS (-) button when the door is near the desired closed position. Single presses of the MINUS (-) button will inch the door closer to the ground.
- If the door overshoots press the PLUS (+) button to move the door in the open direction.
- When the door is at the desired close position, press the LIMIT SET button, the OPEN LIMIT LED will now flash.
- Press and hold the PLUS (+) button until the door reaches your desired open limit position. Single presses of the PLUS (+) button will inch the door open.
- If the door overshoots press the MINUS (-) button to move the door in the close direction.
- Press and hold MINUS (-) button until the door reaches your desired close limit position. The rubber strip at the bottom of the door should form a good seal with the ground.
- Release the MINUS (-) button when the door is near the desired closed position. Single presses of the MINUS (-) button will inch the door closer to the ground.
- If the door overshoots press the PLUS (+) button to move the door in the open direction.
- When the door is at the desired close position, press the LIMIT SET button, the OPEN LIMIT LED will now flash.
- Press and hold the PLUS (+) button until the door reaches your desired open limit position. Single presses of the PLUS (+) button will inch the door open.
- If the door overshoots press the MINUS (-) button to move the door in the close direction.
- When the door is at the desired open position, press the LIMIT SET button.
- The door will now automatically close and open to calculate the safety obstruction settings.
Resetting the Door Limit Positions Limit positions can be deleted by
-
Press and hold LIMIT SET button for six (6) seconds until the CLOSE LIMIT LED flashes quickly.
-
Release the LIMIT SET button.
NOTE: If no action is taken within 30 seconds, the opener will return to normal operating mode and restore the original settings. -
Follow steps a – f in Set the Limits Poisitions to set new limit positions.
Setting the PET Mode position
When activated, PET mode drives the door to a preset position from the close
position, therefore allowing a pet or parcel to go under the door.
- Drive and stop the door at the deisred PET mode open position by pressing the transmitter button coded for Open/Stop/Close operation.
- Press and hold the PLUS (+) button on the opener for six (6) seconds until the OPEN and CLOSE LED’s are lit to record the new PET position.
- Release the PLUS (+) button.
Reset all Factory Defaults
- Turn power to the opener off.
- Press and hold the LIMIT SET Button.
- Turn power on while holding the LIMIT SET button. Continue to hold until all LED’s are off.
- This will not erase transmitter codes stored in memory.
Safety Testing
Test the Close Cycle
- Press the OPERATE button to open the door.
- If the door closes, press the OPERATE button to stop the door, then press OPERATE again to open.
- Place a piece of timber approximately 40mm high (or the openers cardboard box) on the floor directly under the door.
- Press the OPERATE button to close door.
- The door should strike the object and re-open.
- Remove the timber or cardboard box.
WARNING! If the door is closing and is unable to re-open when obstructed, discontinue use. Do not use a door with faulty obstruction sensing.
Testing the Open Cycle
- Press the OPERATE button to close the door.
- Press OPERATE again to open the door.
- When the door reaches approximately half way, firmly grab the door’s bottom rail – the door should stop.
If the door does not reverse readily when closing, or stop when opening, put the door into manual by pulling down on the manual release string to diesengage the motor and contact 1300 300 625 for support.
Test the Manual Door Operation
Periodically disengage the opener and manually operate the door. The door must
be smooth to operate by hand. The force required on the bottom rail should not
exceed 20 kg.
Adjusting Safety Obstruction Force
The Safety Obstruction Force is calculated automatically during setup.
Adjusting this is normally only necessitated by environmental conditions such
as windy or dusty areas, and areas with extreme temperature changes.
To Increase Force Pressure
- Hold down the FORCE MARGIN SET button.
- While holding the FORCE MARGIN SET button, press the PLUS (+) button. Each press will increases the force margin.
The OPEN LIMIT LED will flash each time the PLUS (+) button is pressed to
indicate an increase in force.
If the OPEN LIMIT LED flashes continuously when the PLUS (+) button is being
pressed, this indicates that the maximum force setting has been reached.
Test the force again as per Testing Close Cycle and Testing Open Cycle.
To Decrease Force Pressure
- Hold down the FORCE MARGIN SET button.
- While holding the FORCE MARGIN SET button, press the MINUS (-) button. Each press will decrease the force margin.
- The CLOSE LIMIT LED will flash each time the MINUS (-) button is pressed to indicate a decrease in force.
- If the CLOSE LIMIT LED flashes continuously when the MINUS (-) button is being pressed, this indicates that the minimum force setting has been reached.
- Test the force again as per Testing Close Cycle and Testing Open Cycle.
CAUTION: Take care when completing a safety test. Failure to follow this warning can result in serious personal injury and/or property damage.
WARNING! If the door fails these tests, put the opener into manual mode, only operate the door by hand and call for service.
To Recall Factory Set Force
- Holding down the FORCE MARGIN SET button and the LIMIT SET button for two seconds.
- Release both buttons. The default setting should now be recalled.
To Recalculate Force Margins
- Press and hold the FORCE MARGIN SET Button for six (6) seconds, the beeper will sound once.
- The door will start to move and re-calculate force margins. The door can move between the open and close limit positions up to four (4) times (depending on the position of the door and the power up condition).
- A single beep will be heard once the process is complete.
- Test the force again as per Testing Close Cycle and Testing Open Cycle
Accessories
Auxiliary Output
The auxiliary output can be used to control alarm or another garage door
opener. A valid transmission from the pre-coded transmitter will cause the
auxiliary output to pulse for approximately 1 (one) second. The maximum DC
voltage must not exceed 35 volts DC. Maximum current must not exceed 80 ma.
Keyswitch Connection
The RDO-1V4 has the input to connect bell switch or keyswitch to open or close
the door.
Remote Aerial
Some sites cause poor radio reception. Particularly problematic areas are
those where there is a large amount of metal, like a steel garage, or an
underground car park with large masses of steel reinforced concrete. These
issues, and others, can create reception issues.
Poor radio reception will be noticed by a reduction in the operating range of
the transmitters.
You can evaluate whether fitting an external aerial will benefit as follows;
- Test the maximum operating range of the transmitter with the garage door closed; then
- Test the maximum operating range of the transmitter with the garage door open.
If the range improves when the door is open you can install a remote aerial
kit to improve reception.
Mount the aerial to a suitable location on the outside of the garage.
Similar to a television aerial, the better the mounting position the better
the reception will be. Where possible, mount the aerial as high as possible,
away from masses of metal and in line of sight position, to where you normally
use your transmitter.
Auto-Close (CAD PD Only)
Safety Beams
A Safety Beam Kit may be fitted to this opener. When this option is fitted, the operation of this device is such that if an object (i.e car, child etc) blocks the Infra-Red beam, then the garage door opener will not close the door automatically. If the Safety Beam is fitted but not operating coreectly, then the door once opened automatically, will not close automatically.
Auto Close Option
Auto-Close mode is a function that automatically closes the door a preset time
after the Safety Beams recognise that a vehicle has left the garage. The Auto-
Close timer only starts after the Safety Beam’s path is broken. If the safety
beam path is not broken, the door will remain open until the path is broken.
If the opener incurs a physical obstruction (i.e. not from the Safety Beams)
while closing the door, it will re-open and not Auto-Close until the Safety
Beam’s path is broken again.
To enable the Auto-Close function remove the light diffuser from the opener
and remove the AUTO-CLS (ACLS) shunt next to the programmer input and place
over both ACLS inputs. When this option is selected the garage door opener
will attempt to close the door automatically 30 seconds after opening. Refit
the light diffuser.
WARNING! It is compulsory to have Safety Beams installed when using Auto- Close mode.
14. Coding a Transmitter
Storing the Transmitter Code
The opener can only operated from remote control transmitters that have been
programmed into its memory. Up to 64 codes can be stored in the memory.
- Press the CODE SET button and release. The CODE SET LED will illuminate to indicate the opener is in Code Learn mode. If a valid code is not stored within 15 seconds the opener will exit Code Learn.
- Press the transmitter button one (1) to control the door. The CODE SET LED will flash.
- Press the same transmitter button again. The CODE SET LED will illuminate for one second then go out.
- The transmitter button is now coded – press to test.
Coding a Transmitter to the Courtesy Light
The transmitter can be programmed to operate the courtesy light on the opener
independently of the door moving.
- Press the CODE SET button twice – the CODE SET LED and courtesy light will both illuminate.
- Press one of the four buttons on the transmitter for two (2) seconds, pause for two (2) seconds, then press the same button again for two (2) seconds.The CODE SET LED will illuminate for one second then go out.
- Press the transmitter button to test.
Coding a Transmitter Button to Enable Vacation Mode
The opener can be programmed into a “Vacation Mode” where the opener will not
respond to any transmitter except the button of the transmitter that was
programmed for vacation mode.
- Press the CODE SET button three (3) times – the CODE SET LED will illuminate and the courtesy light will flash slowly.
- Press one of the four (4) buttons on the transmitter for two (2) seconds, the CODE SET LED will begin to flash, pause for two (2) seconds, then press the same button again for two (2) seconds.
- The CODE SET LED will illuminate for one second and then go out, and the courtesy light will also switch off. This indicates the code has been stored.
- Press and hold the transmitter button for five (5) seconds to set Vacation Mode. The CODE SET LED will stay lit while Vacation Mode is active.
- To reset Vacation Mode, press the same button for two seconds, until the CODE SET LED turns off.
Coding a Transmitter to enable AUX Output
- Press the CODE SET button four (4) times – the CODE SET LED will illuminate and the courtesy light will flash quickly.
- Press one of the four (4) buttons on the transmitter for two (2) seconds, the CODE SET LED will begin to flash, pause for two (2) seconds, then press the same button again for two (2) seconds. The CODE SET LED will illuminate for one second then go out.
- Press the transmitter button to test.
IMPORTANT NOTE: Only Tri-Tran+TM Technology Transmitters are compatible with these RDO-1 products.
Coding a Transmitter
Setting the Transmitter to Operate PET (Pedestrian) Mode
The PET mode position (see Programming the Opener) must set prior to coding a
transmitter.
- Press the CODE SET button five (5) times – the CODE SET LED will illuminate and the courtesy light will flash quicky (twice per second).
- Press one of the four (4) buttons on the transmitter for two (2) seconds, the CODE SET LED will begin to flash, pause for two (2) seconds, then press the same button again for two (2) seconds.
- The CODE SET LED will illuminate for one second and then go out, and the courtesy light will also switch off. This indicates the code has been stored.
- Press the transmitter button to test.
Installation of the Wall Mounted Transmitter (RDO-1V4 Only)
- Mount the transmitter in a convenient location, yet out of reach of children and at least 1.5m off the ground.
- Make sure the door is visible from this location.
- To set the transmitter press the CODE SET button and release. The CODE SET LED will illuminate to indicate the opener is in Code Learn mode. If a valid code is not stored within 15 seconds the opener will exit Code Learn.
- Press the transmitter button (one of four) that you want to control the door. The CODE SET LED will flash.
- Press the same transmitter button again. The CODE SET LED will illuminate for one second then go out.
- The transmitter button is now coded – press to test
Remotely Coding Transmitters
Using this method transmitters can be coded without access to the opener’s
control panel as long as a pre-coded transmitter is available.
- Take any pre-coded transmitter. Press the button for the function to be duplicated and release.
- Using a small needle / pen, press and hold firmly for two seconds the middle button, through the Coding Hole.
- Within ten (10) seconds take the additional transmitter you wish to code. Hold the new transmitter’s button for two seconds, pause for two seconds, hold again for two seconds and then release.
- Wait for ten (10) seconds and then press the new transmitter’s button to test.
Erasing Programmed Codes
If the CODE SET button is pressed and held for six (6) seconds the CODE SET
LED will blink rapidly for one second to indicate that all programmed codes
have been erased.
Home Owner Safety Warnings
This automatic garage door opener is designed and tested to offer safe service provided it is installed and operated in strict accordance with the following safety warnings. Failure to comply with the following instructions may result in death, serious personal injury or property damage.
WARNING! IMPORTANT SAFETY INSTRUCTIONS IT IS IMPORTANT FOR THE SAFETY OF
PERSONS TO FOLLOW ALL INSTRUCTIONS.
SAVE THESE INSTRUCTIONS
WARNING
- Automatic Door – the door may operate unexpectedly, therefore do not allow anything to stay in the path of the door.
- Details on how to use manual release. When operating the manual release while the door is open, the door may fall rapidly due to weak or broken springs, or due to being improperly balanced.
- DO NOT disengage the opener to manual operation with children/persons or any objects including motor vehicles within the doorway.
- If the door is closing and does not re-open when obstructed, discontinue use. DO NOT use a door with faulty obstruction sensing.
- Frequently examine the installation, in particular check cables, springs and mountings for signs of wear, damage or imbalance. DO NOT use if repair or adjustment is needed since fault in the installation or an incorrectly balanced door may cause injury..
ELECTROCUTION!
- Place opener in protected area so that it does not get wet.
- DO NOT spray with water .
- DO NOT open the protective covers.
- DO NOT operate opener if cable is damaged. It must be replaced by the manufacturer, its service agent or similarly qualified person in order to avoid a hazard.
- Disconnect the supply(s) when cleaning or other maintenance is being carried out..
DO NOT DO IT YOURSELF
- Keep the garage door balanced. Sticking or binding doors must be repaired. Garage doors, door springs, brackets and their hardware are under extreme tension and can cause serious personal injury. DO NOT attempt any garage door adjustment. DO NOT use if repair or adjustment is needed. Call for a professional garage door service.
BATTERY WARNING
- This product contains a lithium button/coin cell battery in the transmitters. If a new or used lithium button/coin cell battery is swallowed or enters the body, it can cause severe internal burns and can lead to DEATH in as little as 2 hours. Always completely secure the battery compartment. If the battery compartment does not close securely, stop using the product, remove the battery and keep it away from children. If you think batteries might have been swallowed or placed inside any part of the body, SEEK IMMEDIATE MEDICAL ATTENTION.
CAUTION
Emergency access
- If your garage has no pedestrian entrance door, an emergency access device should be installed. This accessory allows manual operation of the garage door from outside in case of power failure.
Entrapment under operating door
- Watch the moving door and keep people away until the door is completely opened or closed. DO NOT operate door when persons are near the door.
- DO NOT allow children to play with door controls or transmitters. Keep remote controls away form children.
- The appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction.
- Children being supervised not to play with the appliance.
- Regularly conduct Open and Close cycle testing.
Fall from Ladder
- Each month check that the drive reverses when the door contacts a 40mm high object placed on the floor. Adjust if necessary and recheck since an incorrect adjustment may present a hazard.
- Ensure the garage door is in good working order by undertaking regular servicing.
- Wall transmitters should be installed in a location where the garage door is visible, but out of the reach of children at a height of at least 1.5m.
- Install Safety Beams (recommended).
- Ensure ladder is the correct type for the job.
- Ensure ladder is on flat ground.
- Ensure user has 3 points of contact while on ladder.
Entanglement in or laceration from moving door
- Keep hands and loose clothing clear of door and guides at all times.
- Keep hands clear of moving door as sharp edges can cause cuts or lacerations.
Opener Safety & Security
Your Door CAN NOT be used by the opener when
- There is a locking device installed.
- There is a power failure.
Your Door CAN be used when
To Disengage the Opener
- It is recommended to do so with the door in the closed position.
- Pull down on the manual release cord, until you hear a click.
- Move the door manually.
CAUTION: When the opener is manually disengaged, the door is no longer locked. To lock the door manually, re-engage the opener after the door is closed.
To Re-Engage the Opener
- Check the door has not been locked by a locking device.
- Pull down on the manual release cord, until you hear a click.
- The door will now operate from the opener.
WARNING! Please test the manual release mechanism to ensure that the manual release is easy to operate. No more than 20kg of force should be required to disengage the door using the manual release cord. If excessive force is required reset the close limit position (Section 10. Resetting Door Limits).
WARNING! When operating the manual release (while the door is open) the
door may fall rapidly due to weak or broken springs, or due to being
improperly balanced.
Do not disengage the opener to manual operation with children/persons or any
objects including motor
Operating your Opener
To Operate the opener
- Press the programmed transmitter button until your door begins to move (usually 2 seconds). Make sure you can see the door when you use the transmitter.
- If you are in a vehicle you should aim the transmitter through your windscreen as shown.
- Check that the door is fully open or closed before you drive in or away.
- If you press the transmitter whilst the door is moving the door will stop. The next press of the transmitter will move the door in the opposite direction.
User Operating Controls
Button | Function |
---|---|
1. OPERATE | Opens/stops/closes the door. |
2. CODE SET LED (Red) | Flashes when a code is being stored or when the |
transmitter button is pressed
3. CLOSE LIMIT LED (Red)| Illuminates and flashes as the door closes, and
remains on when the close limit position has been reached.
4. OPEN LIMIT LED (Green)| Illuminates and flashes as the door opens and
remains on when the open limit position has been reached.
5. SERVICE LED (Yellow)| Indicates when the opener requires service or
repairs.
6. CODE SET and MINUS (-)| Is used for storing or erasing transmitter buttons
for door operation
Door Status Indicators
Door Status Indicators| OPEN LED (green)| CLOSE LED
(red)| Beeper
---|---|---|---
Open| On| |
Close| | On|
Opening| Flashing| |
Closing| | Flashing|
Door travel stopped| Flashing| Flashing|
Door obstructed when opening| Flashing| | Beeps while door is moving
Door obstructed when closing| | Flashing| Beeps while door is moving
Opener overloaded| Alternating flashes| Alternating flashes|
Mains power interrupted| Rapid flashes| |
20. Specifications
Technical Specifications| Power Drive RDO-1V4| Roll-A-Pro ®
**RDO-1V3
---|---|---
Rated voltage range :| 230V – 240V| 230V – 240V
Rated frequency :| 50Hz| 50Hz
Maximum door opening Door Heigh t:
Door Area :
Maximum Door Weight :
Door must be well balanced and able to be operated by hand, as per warranty
conditions and standard AS/NZS 4505:** 2012| 3.25 turns of the drum wheel
(approx. 3000mm)
16.5m2 110kg
| 3.25 turns of the drum wheel (approx. 3000mm)15.0m2 110kg
Minimum sideroom| 41mm| 41mm
Rated temperature| +5oC to +40oC| +5oC to +40oC
Rated Load :| 400N| 350N
Short Term Peak Force| 600N (60kg)| 500N (50kg)
Nominal force| 200N (20kg)| 200N (20kg)
Receiver type| Multi-frequency| Multi-frequency
Receiver code storage capacity| 64 x Tri-Tran+ 4-button Transmitters| 8 x Tri-
Tran+ 4-button Transmitters
Coding System| Tri-Tran+ Technology| Tri-Tran+ Technology
Coding type| Non-linear encryption algorithm| Non-linear encryption algorithm
Number of code combinations| Over 100 billion random codes| Over 100 billion
random codes
Transmitter battery| CR2032 (3 Volts)| CR2032 (3 Volts)
Courtesy light| LED (Light Emitting Diodes)| LED (Light Emitting Diodes)
Note: Intermittent operations may occur in areas which experience very strong winds. The strong wind puts extra pressure on the door and tracks which may in turn intermittently trigger the safety obstruction detection system.
Troubleshooting
Symptom | Possible cause | Remedy |
---|---|---|
The opener does not work from the transmitter | The opener does not have power |
The battery in the transmitter is flat Transmitter does not contain
Tri-Tran+ Technology
The opener has been put into “Vacation Mode”
The transmitter button is not programmed to operate the door.
Door Code LED is flashing yet the opener is not working.| Plug a device of
similar voltage (e.g. a hairdryer) into the power point and check that it is
OK Replace the battery Check that the transmitter has grey buttons and the
model number on the back displays V2.
Contact dealer for support if otherwise.
Turn off “Vacation Mode” (Section 14)
Code in the transmitter
Ensure the correct button on the transmitter is being pressed.
One transmitter works but the other/s do not| Faulty transmitter
Flat battery| Replace transmitter
Replace battery
The motor is running but the door remains stationary| The opener is
disengaged| Re-engage the opener
The transmitter range varies or is restricted| Variations are normal depending
on conditions e.g. temperature or external interference
The battery life is exhausted Position of the transmitter in the motor vehicle
| Make sure you can see the door when you use the transmitter Check the battery status by pressing a button (flashing or no light requires battery to be changed)
Aim the transmitter through the windscreen.
The Courtesy light does not work| LED has failed| Change LED.
The door reverses for no apparent reason| This may occur occasionally from
environmental conditions such as areas that are windy, dusty or have extreme
temperature changes.| Ensure the door runs smoothly before increasing the
force pressure.
| If Safety beams are installed they may be partially obstructed.| Ensure the
beam path is not obstructed. Check the Alignment.
The door stops or moves very slowly.| Garage door in poor condition e.g.
springs may be broken.
(Optional Battery Back Up Accessory) The batteries may have little OR no charge
| Check the door’s operation.
Connect mains power and leave the batteries to charge. The batteries may take
24 to 48 hours to reach their maximum charge capacity.
Symptom| Possible cause| Remedy
---|---|---
The SERVICE LED has started to flash and is beeping numerous times| A Fault
has been detected. The fault will be active each time an attempt is made to
operate the door.| Record opener function (How many beeps?) then press the
LIMIT SET button once to reset the opener. If the fault continues to be
tripped contact 1300 769 850 for support.
The Open (Green) LED and Close (Red) LED are flashing alternatively| Opener is
overloaded| Check the doors operation by disengaging the motor and ensuring
the door runs smoothly. If necessary make door adjustments or discontinue use
and contact 1300 769 850 for support.
The Open (Green) LED continues to flash| Door obstructed when opening| Clear
away any obstructions and test door opens correctly. (If door is damaged,
contact your door professionl).
The Close (Red) LED continues to flash| Door obstructed when closing
Limits may be cleared
| Clear away any obstructions and test door closes correctly. (If door is damaged, contact your door professional).
Remove all power sources (including the battery backup). Wait till all lights are out (10-15 secs), then reconnect power. If Red LED is flashing, limits are not set. Reset Limits.
Date | Time | Number of Beeps |
---|---|---|
If You Need a Service Call
If the opener needs a service please call the dealer who installed the garage
door opener (their contact details are usually on a sticker on the back of
your garage door). For product assistance contact 13 62 63 within Australia.
BEFORE CALLING you should have the following information to assist in
providing the appropriate service
-
Has anything happened since the opener last operated OK, e.g. a storm, a jolt to the door etc.?
-
What is the current light status on the opener?
-
Manually disengage the door (Section 16).
How easy is it to manually open and close the door? -
What model is the opener? (Model no. information is located at the rear of the opener)
-
Who installed the opener? (Dealer details should be on a sticker on the back of your garage door)
-
When was it installed? (If known)
After Installation Care
Service Checklist
Preventative servicing of your garage door and opener, is just as important as
servicing your car. Much like the engine of your car, your garage door is made
up of numerous moving parts designed to lift and lower your door safely and
efficiently.
Ongoing preventative servicing ensures that your door continues to function
within factory specifications, greatly reduces the risk of failure and repair
bills down the track and ensures you maintain your Warranty.
Run the Safety Testing procedures MONTHLY in Section 11 to ensure garage door
is fit for use.
WARNING! Failure to maintain your your garage door voids the warranty on your garage door opener.
DO NOT DO IT YOURSELF
DIY Door adjustments should only be carried out by experienced persons, as
this function can be dangerous if not performed under strict safety
procedures.
TECHNICIAN CHECKLIST
- Lubrication of the critical moving parts including chain drive, tracks, wheels or cable drum.
- Tightening of door mounting points along with door bolts, screws, cables and connectors.
- Adjustment of spring tension to limit ‘spring fatigue’.
- Adjustment of opener travel limits and force margin to ensure the door opens and closes to specification.
- Assessment and adjustment of safety components and accessories including safety beams and Auto-Lock (if installed)
- Assessment of the door alignment and the diagnosis of irregular operation remedies.
- Record Cycle count at each service to establish next date of service (as per table)
| SERVICE 1
(12 months after installation or 3,000 cycles)
| SERVICE 2
(3 years after installation)
| SERVICE 3
(5 years after installation)
---|---|---|---
DATE:| | |
BUSINESS NAME:| | |
TECHNICIAN NAME:| | |
PG3 COUNTERS OPEN CLOSE| OPEN|
CLOSE| OPEN CLOSE
STALLS| | | | | |
OBSTRUCTIONS| | | | | |
SENSOR FAULTS| | | | |
OVERLOADS / CUT-OUTS| | | | | |
WARRANTY CYCLES| | | | |
FIRMWARE UPDATE AVAILABLE?
IF ‘YES’ PLEASE UPDATE FIRMWARE
| YES| NO| YES| NO| YES| NO
CURRENT FORCE MARGIN| | |
TECHNICAL SIGNATURE:| | |
| SERVICE 4
(7 years after installation)
| SERVICE 5
(9 years after installation)
---|---|---
DATE:| |
BUSINESS NAME:| |
TECHNICIAN NAME:| |
PG3 COUNTERS OPEN CLOSE| OPEN| CLOSE
STALLS| | | |
OBSTRUCTIONS| | | |
SENSOR FAULTS| | |
OVERLOADS / CUT-OUTS| | | |
WARRANTY CYCLES| | |
FIRMWARE UPDATE AVAILABLE?
IF ‘YES’ PLEASE UPDATE FIRMWARE
| YES| NO| YES| NO
CURRENT FORCE MARGIN| |
TECHNICAL SIGNATURE:| |
After Care Installation
Battery Replacement
Battery Type
3V Lithium Battery CR2032.
To test the battery is working, press andhold a transmitter button. Check
Light Status table to determine if battery needs replacing
Light Status | Battery Status |
---|---|
Solid | OK |
Flashing | Requires replacement |
No light | Requires replacement |
Use finger nails to separate the transmitter casing to expose circuit board.
Use a non-metallic object (e.g. pen) to remove the battery.
WARNING! Chemical Burn Hazard. Keep batteries away from children.
Battery Disposal
When batteries reach the end of their usual life in accordance with Australian
Battery Recycling Initiative please follow the next simple steps for
protecting the environment. Refer to the Automatic Technology website for
information on where to recycle batteries in Australia.
DO NOT throw the batteries in municipal waste. This symbol of the crossed out wheeled bin indicates that the battery should not be placed in the municipal waste. Check your local regulations for appropriate disposal of the batteries.
Recycling all batteries will have other environmental and social benefits
- Some batteries are less toxic but hazardous for other reasons. Lithium batteries can explode or catch fire in landfill, while button cells are dangerous if swallowed by children. Recycling offers a safe and environmentally responsible solution for end of life batteries.
- Battery recycling recovers non-renewable materials such as lead, cadmium, stella, zinc, manganese, cobalt, silver, plastics and rare earth elements.
- Removal of batteries and other hazardous household products from household waste facilitates the recovery of organic materials through alternative waste technologies such as composting. Batteries and heavy metals are known contaminants in compost.
- The community supports recycling because it reduces waste to landfill and achieves environmental benefits.
WARNING! Prior to disposal, recycling, or collection, all battery terminals must be securely insulated with a non conductive material to prevent any two batteries from short circuiting and generating heat during storage or transport. Battery terminals may be insulated with electrical tape; or batteries may be individually packaged in a non conductive material (e.g., plastic bag or original packaging).
Warranty
Warranty conditional on proper servicing as listed in 22.1 Service Checklist.
Full details of the warranty are available in your Owners Opener Handbook,
from your nearest B&D office or visit the B&D
- Website : bnd.com.au.
b &d doors office locations
- Head Office : 6-8 Fiveways Blvd, Keysborough 3073 Phone (03) 9791 2000
- New South Wales :34 Marigold St, Revesby 2212 Phone (02) 9722 5555
- Queensland :17 Oasis Court, Clontarf 4019 Phone (07) 3883 0200
- Victoria :147-153 Canterbury Rd, Kilsyth 3137 Phone (03) 9237 7766
- South Australia :23 Frederick Rd, Royal Park 5014 Phone (08) 8440 4747
- Western Australia : 96 Mulgul Rd, Malaga 6090 Phone (08) 9247 8777
- International/Export : 34 Marigold St, Revesby 2212 Phone +61 (0)2 9722 5555
Prefixed trademarks are the property of B&D Australia Pty Ltd. B&D Doors &
Openers is a division of B&D Australia Pty Ltd. ABN 25 010 473 971. © 2018 B&D
Australia Pty Ltd.
www.bnd.com.au
References
- B&D Garage Doors - Safe and Secure Australian Garage Doors - B&D Australia
- B&D Garage Doors - Safe and Secure Australian Garage Doors - B&D Australia
Read User Manual Online (PDF format)