profi-pumpe SP02125-3 Solar Fountain Instruction Manual

June 13, 2024
profi-Pumpe

SOLAR FOUNTAIN
Version 22.12
OPERATING INSTRUCTIONS (Translation)

profi pumpe SP02125 3 Solar Fountain - Cover

Instruction Manual

SP02125-3 Solar Fountain

Technical changes, misprints and mistakes reserved! Newest information about our products can be found online.

SAFETY INSTRUCTION AND WARNINGS

| Please read the user manual before using the pump| | Warning sign
---|---|---|---

INTRODUCTION

We would like to congratulate you on the purchase of our pump. We appreciate your trust. That`s why functional security and operational safety stands on first place for us.
To prevent damage to persons or property, you should read this user manual carefully. Please observe all safety precautions and instructions for proper use of the pump. Failure to follow the instructions and safety precautions can result in injury or property damage. Please keep this manual with the instructions and safety instructions carefully in order to at any time you can restore them.

IN GENERAL

Solar Pond Pump Kits are high-quality fountain pump systems for energy use in outdoor or indoor use. The perfect eye-catcher in your garden or seed tray. Through the use of high-quality solar technology with Li-Ion batteries are the Solar Pond Pump Kits mains-independent and anywhere to use immediately.
2.1 It`s recommended NOT to conduct yourself technical modifications. First, it is not certain whether these changes are technically correct and, secondly, because no guarantee can be granted.
2.2 Transport damages are immediately to be reported to the package distributor and to us in written form. Failure to give timely notice to the shipping company, and are therefore rejected your claims from the transport company, so we can not accept these claims as well. In your legal obligation to cooperate to minimize damage, we point out expressly herewith.

OPERATION

  • Unpack all components carefully. You should have received the following parts:
    1pc Umbrella and couple statue / 1pc Reservoir / 1pc Base / 1pc pump / 1pc LED light / 1pc Solar panel with battery/ 1pc Solar panel bracket / 1pc Extension tube / 1pc Ground spike To protect the product, place all parts on a soft surface before assembly.

  • If there is a rubber bung, lead the cables through it and place it on the tube in the corpus to avoid water leakage.

  • Remove the protective film from the solar panel (if any).

  • Position the solar panel so that it receives direct sunlight. The fountain can not work if the solar panel is shaded. Adjust the solar panel angle to maximise the amount of solar energy collected. Connect the pump on the panel (see item 5). Check whether the flow is fully open (or else promoted little or no water).
    profi pumpe SP02125 3 Solar Fountain - OPERATION 1

FROST

Frost can cause damage to the pump. In freezing the pump, pipes and water tank must be emptied, rinsed with clean water and stored dry.

ASSEMBLY INSTRUCTION

5.1 The set is not pre-connected and you need to assemble this. Place reservoir on top of the base and twist the reservoir clockwise to secure.
Reservoir

5.4 Feed the pump power cord through plastic tube toward bottom of the base. Cord exit out from channel on the bottom of the base.

5.3 Attach pump to the rubber hose underneath the couple statue into the reservoir and twist the couple statue clockwise to secure.
profi pumpe SP02125 3 Solar Fountain - ASSEMBLY INSTRUCTION
3

5.4 Fill reservoir with appropriate amount of water to completely submerse the pump.
Note: Destilled water is recomended to reduce mineral deposits and bacteria build-up.

5.5 Join bracket, tube and spike together, then attach bracket to back of the solar panel as shown.

5.6 Twist pump plug slightly and pushing it into the pump socket. Then twist LED light plug slightly and pushing it into the light socket. Make sure the sealing ring is fully in groove

5.7 Press bottom tip in the ground. Make sure that the solar panel receives direct sunlight and is not shaded by trees or buildings.
profi pumpe SP02125 3 Solar Fountain - ASSEMBLY INSTRUCTION
7

PERFORMANCE

The performance of the pump depends on the orientation of the solar panels toward the sun and the intensity of the max. Data obtained under optimal conditions. Function in the shade or on cloudy days can not be guaranteed. In models with battery operation depends on the function of the battery is charged.

  • Press ON/OFF button on back side of the solar panel to turn on the pump. The battery indicator lamp will be on. With ,,Press” is always meant ,,touching”, because a sensor is used as a ,,Pushbutton”.

  • Press ON/OFF button on back side of the solar panel to turn off the pump. The battery indicator lamp will be off.

  • The LED light only works, when day goes dark. l When battery power is low, the system will automatically shut off the pump to protect the battery. The indicator lamp
    will be off in this case. The pump can not work, until the battery is recharged. The recharging time should depend on sunlight conditions.

  • The charging process will be interrupted as soon as the battery is fully charged to prevent overcharging.

  • The pump will automatically start next morning, when solar panel receives enough sunlight.

NOTE: The battery is supplied charged. If the state of charge, contrary to expectations, not be sufficient to charge the batteries for at least 8 hours to allow sufficient charging of the battery (so damage the battery to avoid overcharging, the pump must be connected).

WARNINGS ON BATTERY

Lithium Ion cells and battery may get hot, explode or ignite and cause serious injury if they are exposed to abusive conditions, Be sure to follow the safety warnings listed below:

  • Do not install the battry backwards, so the polarity is reversed l Do not connect the positive or/and negative terminal or/and the battery to each other with any meta object, such as wire
  • Do not disassemble or modify the battery. The battery contains safety and protection devices which may cause the battery to generate heat, explode or ignite if damaged
  • Do not place the battery in or near fire, on stoves or other high temperature locations. Do not place the battery iiin direct sunlight or use/store the battery inside cars during hot weather. Doing so may cause the battery to generate heat, explode or ignite
  • It is not advised for children to handle the battery
  • When the battery is worn out, wrap the terminals with adhesive tape or similar materials before disposal
  • Immediately discontinue use of the battery, if there is an unusuak smell, a change of color or shape, or if it appears abnormal in any other way
  • Do not place the battery in microwave ovens, high pressure containers or on cookware facilities
  • In the event of the battery is leaking and fluid gets into your eye, do not rub the eye, rinse well with water and immediately seek medical advice. If left untreated, the battery fluid could cause serious injury to the eye

BATTERY REPLACEMENT

After used for 12 to18 months, the battery have reached it‘s service life, you should replace the battery. Unscrew the battery cover, replace the battery with a new one. Please pay attention to limited Warranty: 3 months.
How to replace the battery:
8.1 Remove LED light plug and pump plug from solar panel
8.2 Remove cover from solar panel above by unscrewing (6) screws
8.3 Disconnect the connectors, then replace the old battery pack with a new battery pack and join the connectors together
8.4 Secure the cover to solar panel with the 6 screws you removedPOWERSHADES
PS 3.23 Roller Shade Systems - Trouble Shooting12

SECURITY TIPS

  • Obey absolutely valid regulations on the electrical security

  • Never run pump dry

  • Pumping inflammable, as well as all other aggressive liquids is prohibited

  • Pay attention to the medium max. 40°C

  • Any altering of the product itself or changing of the components is forbidden.

  • With longer unused times, clean the pump, wash it out with clear water, dry and store it at room temperature

  • Do not connect the pump to any AC voltage power directly, it’s ONLY for DC Voltage power.

  • Operate the pump in freshwater or saltwater only (never above 50°C), especially keep it away from flammable liquids.

  • All solar panels are very sensitive, protect it before all against external mechanical influences (shock, vibration, etc.)
    The manufacturer explains:

  • To take over no responsibility in the case of accidents or damages on the basis of carelessness or disregard to the instructionsin this book.

  • to reject every responsibility for the damages which originate from the improper use of the pump

SERVICING

If after some time the pump starts losing power or stops working, please clean up sediment in the pump shell or filter cribs. Kindly note the pump can be opened by pressing down at the bottom of the filter housing. To clear the impeller, open the pump housing at the front by sliding up the front plastic cover.
The solar module should only be cleaned with soft tissue or propriety glass cleaning solution.POWERSHADES PS 3.23 Roller Shade Systems - Trouble
Shooting13

  1. Front case
  2. Filter
  3. Impeller cover
  4. Impeller
  5. Pump

GUARANTEE REGULATIONS

For all manufacturer defects and material defects we grant the legal guarantee time (new and unused product). In such cases we take over the exchange or the repair of the pump. Forwarding expenses are not carried by us.
The guarantee is not valid with:

  • Material wear (sealing rings, impeller wheels, impeller chambers)
  • Unjustified interventions or changes in the pump
  • Damages by selffault
  • Improper servicing and improper use
  • DRY RUN (Also partially!) of the pump
    Moreover, we give no damage compensation for secondary damages!

RECOGNISING AND REPAIRING OF MISTAKES

Problem Possible cause Solution
Pump will not turn on No sunlight The orientation of the solar panels up to

the sun
Low charge level of the battery| See item 6 and 8 (Note)
Pump connector is not connected correctly| See item 5.6
Defective pump / solar panel broken| Replace pump or solar panel
Pump runs but no water is encouraged| Pump impeller and filter housing polluted| Disassemble and clean in accordance with point 10, the pump and the housing (by means of water and a soft brush)
Pump has sucked air| Turn off the pump briefly and then back on
(restarting) Attention! Avoid dry running
Coarsining or fountain nozzles dirty| Disassemble and clean the tube and the fountain nozzle

NOTES ON PRODUCT LIABILITY

We point out, that we are only liable for damages under the Product Liability Act, which are caused by our units if no changes were made to the equipment. We are only liable for repairs, if original spare parts and accessories were used and repairs are carried out by our authorized service.

NOTES ON DISPOSAL

** Electro devices of our company, labeled with the symbol of the crossed trash bin, are not permitted to be disposed in your household garbage. We are registered at the German registration department EAR under the WEEE-No. DE79535656. This symbol means, that you’re not allowed to treat this product as a regular household waste item – it has to be disposed at a recycling collection point of electrical devices.
This is the best way to save and protect our earth.
THANK YOU FOR YOUR SUPPORT!
**
In connection with the sale of batteries or with the delivery of equipment containing rechargeable battery packs, the seller is obliged to draw your attention to the following:
You are obliged to return used batteries as an end-user. You can return batteries after use to the seller or to the designated collection facilities, which are free of charge (eg: municipal collection points or in stores). You can return the batteries for disposal at no charge to the seller.

EU DECLARATION OF CONFORMITY

The undersigned, Amur S.à r.l., 36, Rue de la Gare, L-5540 Remich, certifies that the product named overleaf, namely „DIE LIEBENDEN“ as placed on the market, complies with the relevant provisions listed below, the relevant EU harmonised directives and the EU standard for safety. This declaration of conformity applies insofar as no modifications are made to the product. The sole responsibility for issuing this declaration of conformity lies with the manufacturer.
The sole authorised person to keep the technical documents:
Amur S.à r.l. – 36, Rue de la Gare – L-5540 Remich
EC Electromagnetic compatibility directive (2014/30/EU)
The following harmonized standards:
EN 55014-1:2017; EN 55014-2:2015; ROHS: 2011/65/EU; BS EN 55014-1:2017 / DIN BS EN 55014-1;
BS EN 55014-2:2015 / DIN BS EN 55014-2

Signed for and on behalf of Amur S.à r.l. :
Remich, 08.12.2022 i.V. Dipl. Phys. Peter Neumüller
Technical Manager

TECHNICAL DATA

| | Solar-Brunnen
---|---|---
Pump| Power| 1,4 W
Max. pump capacity| 250 l/h
Max pump height| 90 cm
Max. water temperature| 40 °C
Solar module| Rated voltage| 9 V
Amperage| 0,222 A
Power| 2 W
Dimension (LxWxH)| 190x150x18mm
General| Protection grade, Panel/Pump| IP44 / IP68
Dimension (LxWxH)| 51x51x107cm
Total weight| ca. 11 kg
Length of cable| 5 m
Battery type| Li-Ion 7,4 V/1.2AH
Ambient temperature| 0°C – 45°C

SPARE PARTS

The spare parts will be available for purchase from AMUR S.à.r.l. at www .profi-pumpe.de from March 2023.

Spare part / remark| No. / Nr.|
---|---|---
Solar pump Set
Incl. pump, solar panel, LED, spikes.
For technical information see section 16.| A4651
SP022041S| POWERSHADES PS 3.23 Roller Shade Systems - Signatured
2
LED light ring 2| A146
5 001 003 028| POWERSHADES PS 3.23 Roller Shade Systems - Signatured
3
Li-Ion Accu
7,4V / 1,2 AH| A5227
SPZ03101| POWERSHADES PS 3.23 Roller Shade Systems - Signatured
1

** Please note our disposal advice at section 14.
Imprint**

Amur S.à r.l.
www.amur.lu
Email:info@amur.lu
Tel.: (+49) 0611-9 45 87 77-0
Fax: (+49) 0611-9 45 87 77-11

Documents / Resources

| profi-pumpe SP02125-3 Solar Fountain [pdf] Instruction Manual
SP02125-3 Solar Fountain, SP02125-3, Solar Fountain, Fountain
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

profi-Pumpe User Manuals

Related Manuals