MEAN WELL PS-05-5 5W Single Output Switching Power Supply Owner’s Manual
- June 13, 2024
- MEAN WELL
Table of Contents
MEAN WELL PS-05-5 5W Single Output Switching Power Supply
![MEAN-]WELL-PS-05-5-5W-Single-Output-Switching-Power-Supply- PRODUCT](https://manuals.plus/wp-content/uploads/2023/09/MEAN-WELL-PS-05-5-5W- Single-Output-Switching-Power-Supply-PRODUCT.png)
Product Information
The PS-05 series is a 5W single-output switching power supply. It is designed and tested to meet safety standards including BS EN/EN62368-1, TPTC004, and IEC62368-1. This power supply is available in five different models: PS-05-5, PS-05-12, PS-05-15, PS-05-24, and PS-05-48. Each model provides a different DC voltage output.
Model | DC Voltage | Rated Current | Current Range | Rated Power |
---|---|---|---|---|
PS-05-5 | 5V | 1A | 0 ~ 1.2A | 5W |
PS-05-12 | 12V | 0.45A | 0 ~ 0.5A | 5.4W |
PS-05-15 | 15V | 0.35A | 0 ~ 0.4A | 5.25W |
PS-05-24 | 24V | 0.22A | 0 ~ 0.25A | 5.28W |
PS-05-48 | 48V | 0.11A | 0 ~ 0.125A | 5.28W |
The power supply has a maximum ripple and noise of 100mVp-p. It features line regulation and load regulation for stable output performance. The setup and rise time is 1000ms with a rise time of 20ms. The hold-up time at full load is typically 100ms.
It accepts a wide voltage range from 85VAC to 264VAC or 120VDC to 370VDC, covering different power input scenarios. The frequency range is between 47Hz and 63Hz. The power supply has an efficiency rating of approximately 70% to 76% depending on the model. The AC current ranges from 0.15A to 0.07A, and the inrush current during cold start is typically 30A at 230VAC.
Product Usage Instructions
- Ensure that the input voltage matches the specified range of 85VAC to 264VAC or 120VDC to 370VDC.
- Connect the power supply to the desired device using appropriate wiring and connectors.
- Verify that the DC voltage output required by your device matches the selected model of the power supply.
- Turn on the power supply using the designated power switch if available.
- Monitor the output voltage to ensure it is within the acceptable range for your device.
- If necessary, adjust the load within the current range specified for the selected model.
- Observe the power supply for any abnormal behavior or excessive ripple and noise.
- In case of any issues or concerns, refer to the user’s manual or contact the manufacturer for support.
5W Single Output Switching Power Supply
FEATURES
- Universal AC input / Full range
- Low leakage current <O.5mA
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Cooling by free air convection
- 100% full load burn-in test
- Fix switching frequency at 67KHz
- Low cost
- High reliability
- 2 years warrantv
SPECIFICATION
MODEL| PS-05-5| PS-05-12| PS-05-15| PS-05-24|
PS-05-48
---|---|---|---|---|---
OUTPUT
| DC VOLTAGE| 5V| 12V| 15V| 24V| 48V
RATED CURRENT| 1A| 0.45A| 0.35A| 0.22A| 0.11A
CURRENT RANGE| 0 ~ 1.2A| 0 ~ 0.5A| 0 ~ 0.4A| 0 ~ 0.25A| 0 ~ 0.125A
RATED POWER| 5W| 5.4W| 5.25W| 5.28W| 5.28W
RIPPLE & NOISE (max.) **Note.2| 100mVp-p| 120mVp-p| 120mVp-p|
200mVp-p| 200mVp-p
VOLTAGE TOLERANCE Note.3| ±2.0%| ±2.0%| ±2.0%| ±2.0%| ±1.0%
LINE REGULATION| ±1.0%| ±1.0%| ±1.0%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.0%| ±1.0%| ±1.0%| ±0.5%| ±0.5%
SETUP, RISE TIME| 1000ms, 20ms
HOLD UP TIME(Typ.)**| 100ms at full load
INPUT
| VOLTAGE RANGE| 85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY(Typ.)| 70%| 75%| 75%| 76%| 76%
AC CURRENT (Typ.)| 0.15A/115VAC 0.07A/230VAC
INRUSH CURRENT (Typ.)| COLD START 30A/230VAC
LEAKAGE CURRENT| <0.5mA / 240VAC
PROTECTION
| OVERLOAD| Above 105% rated output power
Protection type : Hiccup mode, recovery automatically after fault condition is
removed
OVER VOLTAGE| 5.75 ~ 6.75V| 13.8 ~ 16.2V| 17.2 ~ 20.2V| 27.6 ~ 32.4V|
55.2 ~ 64.8V
OVER TEMPERATURE| Hiccup mode, recovery automatically after fault
condition is removed
ENVIRONMENT
| WORKING TEMP.| -10 ~ +60℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -20 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.05%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X,
Y, Z axes
SAFETY & EMC
(Note 4)
| SAFETY STANDARDS| TUV BS EN/EN62368-1,EAC TP TC 004 approved,
IEC62368-1 CB approved by TUV
WITHSTAND VOLTAGE| I/P-O/P:3KVAC
ISOLATION RESISTANCE| I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
EMI CONDUCTION & RADIATION| Compliance to BS EN/EN55032
(CISPR32) Class B, EAC TP TC 020
HARMONIC CURRENT| Compliance to BS EN/EN61000-3-2,-3
EMS IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS
EN/EN55035, light industry level, EAC TP TC 020
OTHERS
| MTBF| 6873.2K hrs min. Telcordia SR-332 (Bellcore) ; 1271.1K hrs
min. MIL-HDBK-217F (25℃)
DIMENSION| 754020mm (LWH)
PACKING| 0.05Kg; 120pcs/6.25Kg/0.56CUFT
NOTE|
-
All parameters NOT specially mentioned are measured at 230VAC input, rated load and 250C of ambient temperature.
-
Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a O.Iuf & 47uf parallel capacitor.
-
Tolerance : includes set up tolerance, line regulation and load regulation.
-
The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a 360mm*360mm metal plate with Imm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to
perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com) -
The ambient temperature derating of 3.50C/1000m with fanless models and of 50C/1000m with fan models for operating altitude higher than 2000m(6500ft).
https://[www.meanwell.com/serviceDisclaimer.aspx](http://www.meanwell.com/serviceDisclaimer.aspx)
Mechanical Specification
- AC Input Connector (CN2) : Molex 5285-03 or equivalent
Pin No.| Assignment| | Mating Housing| Terminal
---|---|---|---|---
1| FG| | | Molex 5058 or equivalent| Molex 2478 or equivalent
2| AC/N|
3| AC/L| - DC Output Connector (CN1) : Molex 5273-02 or equivalent
Pin No.| Assignment| Mating Housing| Terminal
---|---|---|---
1| +V| Molex 5195 or equivalent| Molex 5194 or equivalent
2| -V
Mechanical Specification
![MEAN-]WELL-PS-05-5-5W-Single-Output-Switching-Power-Supply-FIG- (4)](https://manuals.plus/wp-content/uploads/2023/09/MEAN-WELL-PS-05-5-5W- Single-Output-Switching-Power-Supply-FIG-4.png)
Block Diagram
![MEAN-]WELL-PS-05-5-5W-Single-Output-Switching-Power-Supply-FIG- (6)](https://manuals.plus/wp-content/uploads/2023/09/MEAN-WELL-PS-05-5-5W- Single-Output-Switching-Power-Supply-FIG-6.png)
Derating Curve
Static Characteristics
File Name: PS-05-SPEC 2022-09-20
Downloaded from Arrow.com.
![MEAN-]WELL-PS-05-5-5W-Single-Output-Switching-Power-Supply-FIG- (3)](https://manuals.plus/wp-content/uploads/2023/09/MEAN-WELL-PS-05-5-5W- Single-Output-Switching-Power-Supply-FIG-3.png)
User’s Manual
![MEAN-]WELL-PS-05-5-5W-Single-Output-Switching-Power-Supply-FIG- (2)](https://manuals.plus/wp-content/uploads/2023/09/MEAN-WELL-PS-05-5-5W- Single-Output-Switching-Power-Supply-FIG-2.png)
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTlN.aspx
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>