profi-pumpe SOLAR-DROP P25 Automatic Solar Irrigation System Instruction Manual
- June 12, 2024
- profi-Pumpe
Table of Contents
- profi-pumpe SOLAR-DROP P25 Automatic Solar Irrigation System
- Product Information
- Product Usage Instructions
- SAFETY INSTRUCTION AND WARNINGS
- INTRODUCTION
- IN GENERAL
- ASSEMBLY INSTRUCTION
- OPERATION
- CLEANING AND MAINTENANCE
- RECOGNISING AND REPAIRING OF MISTAKES
- SECURITY TIPS
- GUARANTEE REGULATIONS / STATUTORY WARRANTY
- NOTES ON PRODUCT LIABILITY
- NOTES ON DISPOSAL
- EU DECLARATION OF CONFORMITY
- TECHNICAL DATA
- SPARE PARTS
- ABOUT COMPANY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
profi-pumpe SOLAR-DROP P25 Automatic Solar Irrigation System
Product Information
The Automatic Solar Irrigation System is a high-quality pump system designed for outdoor use. It comes in two models: SOLAR-DROP P25 and SOLAR-DROP P50. The system includes an irrigation unit, filter & water level switch, 1/8 black hose, anti-siphon valve, T adaptor holder, drippers, and stopper. The SOLAR- DROP P25 model comes with 27 drippers and can support up to 25 supply points, while the SOLAR-DROP P50 model comes with 54 drippers and can support up to 50 supply points.
Product Usage Instructions
- Unpack all components carefully.
- If you want to attach the solar panel to the water tank, make sure that the solar panel is facing the midday sun.
- Connect the filter and water level switch and hang them inside the water tank, ensuring they are completely submerged.
- Cut the length of the black 1/8 hose as needed and connect it to the T-adaptor.
- Connect the T-adaptor, black 1/8 hose, and backflow prevention valve (anti-siphon valve), following the indicated direction.
- Clean the joints with a cloth before connecting to avoid leaks.
- Ensure that the anti-siphon valve is placed higher than the drippers.
- Insert the necessary brackets into the floor for stability.
- Connect all the parts as shown in the diagram on page 9, cutting the hose to the appropriate length.
- Close the irrigation system with the plugs at the end of the hose.
- The system can support up to 25/50 supply points depending on the model.
- Allow the irrigation system to charge in direct sunlight for at least 4-8 hours to fully charge the battery after installation.
- Note: When you set the working cycle for the first time, the machine will not work until the next cycle.
Note: For further information and troubleshooting, please refer to the user manual.
SAFETY INSTRUCTION AND WARNINGS
- Please read the user manual before using the device
- Warning sign
INTRODUCTION
We would like to congratulate you on the purchase of our automatic solar
irrigation system. We appreciate your trust. That‘s why funtional security and
operational safety stands by us on first place.
To prevent damage to persons or property, you should read this user manual
carefully. Please observe all safety precautions and instructions for proper
use of the product. Failure to follow the instructions and safety precautions
can result in injury or property damage. Please keep this manual with the
instructions and safety instructions carefully in order to at any time you can
restore them. Please always download the latest version of the user manual of
www.profi-pumpe under „downloads“. This shall always prevail.
IN GENERAL
The automatic solar irrigation system are high-quality pump system for outdoor use.
- It‘s recommended NOT to conduct yourself technical modifications. First, it is not certain whether these changes are technically correct and, secondly, because no guarantee can be granted.
- Transport damages are immediately to be reported to the package distributor and to us in written form. Failure to give timely notice to the shipping company, and are therefore rejected your claims from the transport company, so we can not accept these claims as well. In your legal obligation to cooperate to minimize damage, we point out expressly herewith.
ASSEMBLY INSTRUCTION
- Unpack all components carefully;
- If you want to attach the solar panel to the water tank, make sure that the solar panel is facing the midday sun;
- Connect the filter and water level switch, hang the filter and level switch, away from the ground (floating), in the water tank and make sure it is completely inside the tank;
- You can cut the length of the black 1/8“ hose yourself and then connect the hose and the T-adapter as needed;
- Connect the T-adapter, the black 1/8“ hose and the backflow prevention valve (anti-siphon valve), and pay attention to the direction of the anti-siphon valve as shown below.
- Clean the joints with a cloth before connecting and work on a clean surface to avoid contamination. Dirt on the connections can cause leaks.
- The Anti-siphon valve placement must be higher than drippers.
- Insert the necessary brackets into the floor;
- Connect the parts as shown in the diagram on page 9, cutting the necessary pieces to the appropriate length from the hose supplied;
- Close the irrigation system with the plugs at the end of the hose.
- The system can support up to 25/50 supply points depending on the model;
- The irrigation system is now ready for use.
SCOPE OF DELIVERY
Description| SOLAR-DROP P25
(SP01128)
| SOLAR-DROP P50
(SP01129)
---|---|---
Irrigation Unit| 1 pc| 1 pc
Filter&Water Level Switch 2 in 1| 1 pc| 1 pc
1/8″ Black Hose| 10 m| 15 m
Anti-siphon Valve| 1 pc| 2 pcs
“T” Adaptor| 27 pcs| 54 pcs
Holder| 25 pcs| 50 pcs
2L Dripper| 25 pcs| 50 pcs
Stopper| 1 pc| 2 pcs
OPERATION
After installation, allow the irrigation system to charge in direct sunlight
for at least 4-8 hours to fully charge the battery.
Note: When you set the working cycle for the first time, the machine will
not work until the next cycle.
Modus | Aktion | Ergebnis |
---|
Test
| Turn to
“TEST”
| Irrigation will turn on automatically until the battery is flat.
Turn off the Irrigation| Turn to
“OFF”
| Shut off the irrigation
1 minute
operation
|
Turn to
“1min”
| Irrigation will work 1
minute once a
day in nightfall
5 minutes operation
|
Turn to
“5min”
| Irrigation will work 5
minutes once a
day in nightfall
| | Irrigation will work 2
2 minutes| Turn to| minutes once
operation| “2min”| every two days in
nightfall
8 minutes
|
Turn to
| Irrigation will work 8
minutes once
operation| “8min”| every two days in
nightfall
3 minutes
|
Turn to
| Irrigation will work 3
minutes once
operation| “3min”| every three days in
nightfall
12 minutes
|
Turn to
| Irrigation will work 12
minutes once
operation| “12min”| every three days in
nightfall
How to control your irrigation system:
Low battery: If the batteries are empty, you must charge them with the
solar panel for at least 4-8 hours in direct sunlight.
Low Water level: If there is not enough water in the reservoir, the
irrigation will switch off, in this case fill up the water level in the
reservoir to ensure irrigation.
Cycle Function: To ensure that watering is as water-saving and gentle on
plants as possible, the irrigation system has been optimised for night-time
water delivery.
After setting the pump runtime once, the pump works automatically in the
predefined cycle.
CLEANING AND MAINTENANCE
The irrigation unit should be cleaned at regular intervals with a soft cloth.
It is recommended to clean the solar panel regularly to ensure optimal
conversion of solar energy into direct current.
Please note:
The battery pack has to be exchanged at the latest every 12-18 months! The
Solar modu-le should only be cleaned with soft tissue and proprietary glass
cleaning solution.
RECOGNISING AND REPAIRING OF MISTAKES
Problem | Possible cause | Solution |
---|
Pump does not start
|
No electricity
| 1. Check electr. connections
2. Check batteries
3. Align solar panel so that it receives direct sunlight
Pumpe defekt / Solar- Panel defekt
| Replace pump or solar panel.
For fault location: Check the solar panel to see if the specified voltage is being supplied. Check
whether the specified voltage is provided. Operate the pump with an external battery.
Low battery| Fully recharge the battery (4-8 hours)
Pump runs but no water is encouraged
| Pump impeller or filter housing
dirty
| Dismantle and clean the pump and the housing
(using water and a soft brush).
Pump has sucked in air
(Attention! Avoid dry running)
| Switch off the pump briefly and switch it on again. (Restart)
Hoses or hose connections have a leak| Check hoses or hose connections
Pump has a leak| Check if there is water in the pump housing
Intake openings dirty| Clean intake openings
SECURITY TIPS
- Obey absolutely valid regulations on the electrical security
- Never run pump dry. Test wells for enough flowing water (dry run danger)
- Pumping inflammable, as well as all other aggressive liquids is prohibited
- Observe water temperature of max. 35°C
- The mains plug must be disconnected before carrying out any work on the irrigation system
- During longer unused times, clean the pump, wash it out with clear water, dry and store it at room temperature
- All solar panels are very sensitive, protect it before all against extremal mechanical influences (shock, vibration, etc.)
The manufacturer explains:
- To take over no responsibility in the case of accidents or damages on the basis of carelessness or disregard to the instruction in this book.
- To reject every responsibility for the damages which original from the improper use
BATTERY INFORMATION
After 12 to 18 months, you should replace the battery. For this purpose open
the battery cover and replace the battery with a new. Please find the item
number of the replacement battery in section 12. Technical data and order at
https://www.profi-pumpe.de. Please note the limited implied warranty of 6
months.
Important! It must be ensured that the battery cover is properly tightened and
watertight.
- With repeated charge and discharge cycles Lead-Acid and NiMh battery packs are less efficient (memory effect). This effect is much less pronounced, but still present in small mass in the Li-ion batteries used.
- Through very short and frequent loading operations and many other operational influences batteries can age prematurely strong. The batteries are therefore subject to a consumable and wearing part of a shortened warranty of 6 months.
- If you find that the battery will be less efficient, the battery needs to be fully charged. These allow the unit for 2 to 3 days (pump should not be connected) standing in the sun in order to allow a maximum charge the battery or use a suitable external charger. We recommend to occasionally repeat this procedure to extend the battery life.
- If after this recharging the battery still does not meet expectations, you should replace the batteries.
NOTE: The battery is supplied charged. If the state of charge, contrary to expectations, not be sufficient to charge the batteries for at least 8 hours to allow sufficient charging of the battery (so damage the battery to avoid overcharging, the pump must be connected).
WARNINGS ON BATTERY
Lithium Ion cells and battery may get hot, explode or ignite and cause serious
injury if they are exposed to abusive conditions, Be sure to follow the safety
warnings listed below:
- Do not install the battery backwards, so the polarity is reversed
- Do not connect the positive or/and negative terminal or/and the battery to each other with any meta object, such as wire
- Do not disassemble or modify the battery. The battery contains safety and protection devices which may cause the battery to generate heat, explode or ignite if damaged
- Do not place the battery in or near fire, on stoves or other high temperature locations. Do not place the battery in direct sunlight or use/store the battery inside cars during hot weather. Doing so may cause the battery to generate heat, explode or ignite
- It is not advised for children to handle the battery
- When the battery is worn out, wrap the terminals with adhesive tape or similar materials before disposal
- Immediately discontinue use of the battery, if there is an unusual smell, a change of color or shape, or if it appears abnormal in any other way
- Do not place the battery in microwave ovens, high pressure containers or on cookware facilities
- In the event of the battery is leaking and fluid gets into your eye, do not rub the eye, rinse well with water and immediately seek medical advice. If left untreated, the battery fluid could cause serious injury to the eye
GUARANTEE REGULATIONS / STATUTORY WARRANTY
For all manufacturing and material defects, the statutory warranty applies. In these cases we take the replacement or repair of the device. Shipping costs shall be borne by our company, except as required by law. Please report the warranty on our service platform https://www.profi-pumpe.de/information.php. We will inform you how to proceed with case-related. Returns please sufficient postage. Unfortunately not prepaid re-turns can not be accepted because they are filtered out before delivery. Our service we provide in Germany.
The warranty does not cover:
- Material wear (sealing rings, impeller wheels, impeller chambers)
- Unjustified interventions or changes to the product
- Damages by self fault
- Improper servicing and improper use
- DRY RUNNING (Also partially!) of the pump
Moreover, we give no damage compensation for secondary damages!
NOTES ON PRODUCT LIABILITY
We point out, that we are only liable for damages under the Product Liability Act, which are caused by our units if no changes were made to the equipment. If repairs are carried out by our authorized service, we are only liable if original spare parts and accessories were used.
NOTES ON DISPOSAL
- Electro devices of our company, labeled with the symbol of the crossed trash bin, are not permitted to be disposed in your household garbage. We are registered at the German registration department EAR under the WEEE-No. DE79535656.
- This symbol means, that you’re not allowed to treat this product as a regular household waste item – it has to be disposed at a recycling collection point of electrical devices. This is the best way to save and protect our earth. THANK YOU FOR YOUR SUPPORT!
- In connection with the sale of batteries or with the delivery of equipment containing rechargeable battery packs, the seller is obliged to draw your attention to the following:
You are obliged to return used batteries as an end-user. You can return batteries after use to the seller or to the designated collection facilities, which are free of charge (eg: municipal col-lection points or in stores). You can return the batteries for disposal at no charge to the seller.
EU DECLARATION OF CONFORMITY
- The undersigned, Amur S.à r.l., 36, Rue de la Gare, L-5540 Remich, certifies that the product named overleaf, namely SOLAR-DROP P25 / SOLAR-DROP P50 as placed on the market, complies with the relevant provisions listed below, the relevant EU harmonised directives and the EU standard for safety. This declaration of conformity applies insofar as no modifications are made to the product. The sole responsibility for issuing this declaration of conformity lies with the manufacturer.
- The sole authorised person to keep the technical documents: Amur S.à r.l. – 36, Rue de la Gare – L-5540 Remich
EC Electromagnetic compatibility directive (2014/30/EU)
The following harmonized standards: EN IEC 55014-1, EN IEC 55014-2, EN IEC
61000-3-2,
EN 61000-3-3
TECHNICAL DATA
English| SOLAR-DROP P25
(SP01128)
| SOLAR-DROP P50
(SP01129)
---|---|---
Solar Panel| 1.3W-5V| 1.3W-5V
Pump| 6,5-8V DC| 6,5-8V DC
Water Flow Max.| 600mL/min| 600mL/min*2pcs
Accu| 3,7V-2000mAH Lithium| 3,7V-2000mAH Lithium
Water lift| 3M| 3M
Suction lift| 2M| 2M
Irragation plan| 25 Plants| 50 Plants
DIMENSIONS
SPARE PARTS
ABOUT COMPANY
- Amur S.à r.l.
- www.amur.lu
- Email: info@amur.lu
- Tel.: +49 611 9458777-0
- Fax: +49 611 9458777-11
References
- Amur
- Profi-Pumpe.de Ihr Online-Shop für Pumpen und Pumpenzubehör
- Profi-Pumpe.de Ihr Online-Shop für Pumpen und Pumpenzubehör
- Service - Service
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>