COOLON P20 Strip Profile Instruction Manual
- June 12, 2024
- COOLON
Table of Contents
P20 STRIP
PROFILE
INSTALLATION
INSTRUCTIONS
P20 Strip Profile
Featured on the following products
- ALTO IP
- FORMA
- MULTO IP
- RATIO
- RATIO IP
- SPECTRUM RGBW
- SPECTRUM RGBW IP
P20 INSTALLATION INSTRUCTIONS
- PROFILE DIMENSIONS
- MOUNTING OPTIONS
ATTENTION
- Please observe / follow the instructions methodically.
- Please ensure the units are handled with extreme care.
- Do not remove LED strips from packaging prematurely. Only remove from packaging when ready for installation.
- Failure to observe installation instructions and handling will void warranty of the product.
- WIRING OPTIONS
- WIRING OPTIONS
WIRING DIAGRAM FOR RGBW
For more detailed information, please refer to the specifically used LED
driver’s documentation.
- STEP 1
Before you begin installation, ensure that you understand thfitting layout required as supplied lengths may vary.
Refer to the supplied cut sheet for length breakdowns. - For fittings 1m or longer two installers are recommended.
- WIRING
If the fitting is wired from the back:
It will need to wired before mounting.
If the fitting is wired from the side:
It will need to wired after mounting.
Wire the fitting to the correct power supply as advised on the cut sheet.
- WIRING
STAINLESS STEEL C-CLIP
-
STEP 2
Prepare mounting clips and screws (Ø3.5mm).
Secure mounting clips with screws on timber or metal surface ensuring that mounting clips are positioned screw side up with spacings of 200 – 300mm. -
STEP 3
Lay the luminaire on top of the clips and align so all clips are centred. Starting at one end push down the fitting until you hear the clip lock into place. Continue along the profile until all clips are locked.
ROTATING BRACKET TYPE A & TYPE B
-
STEP 2
Place rhomb nut in the base of the extrusion of the luminaire, ensuring that the edges of the nut are parallel with the edges of the extrusion.
Next place the plastic aligning clip over the rhomb nut. -
STEP 3
Place the edge of the bracket (with the slight lip) over the extrusion and secure the bracket to the rhomb nut using the screw provided. -
STEP 4
Prepare screws (Ø4mm). Secure the other side of the bracket with screws on timber or metal surface ensuring that mounting clips are straight with spacings of 1,000mm. -
STEP 5
Rotate the fitting to the desired angle and use Allen key provided to tighten bracket to secure in place. -
STEP 6
Wire the fitting to the correct power supply as advised on the cut sheet. -
Typically supplied with AU flex and plug (1.8m long)
Version 1.2
archsales@coolon.com.au
aus. 1300 287 533
intl. +613 8681 3633
www.coolon.com.au
All documentation is subject to change without notice. Refer to our website
for the latest information.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>