maquira hemospon Pattern Photo Gel Instructions

June 12, 2024
maquira

maquira - logo hemospon
PATTERN PHOTO GEL

Symbiology

| Keep dry.| | Catalogue Number.
---|---|---|---
| Manufacturer.| | Consult instructions for use for important  preventive information.
| Batch code.| | Do not re-use.
| Keep away from sunlight.| | Temperature limit.
| Use – by date.| |

PRESENTATION:

Hemospon Pattern Photo Gel available in the colors: red, green, blue and A1.

  • 1 Syringe with 3 g and 3 tips.

DESCRIPTION:

Product based on monomers and fillers used in wound dressing procedures.
Ideal for clinical work because it allows a quick application of the product in the region to be worked on. Hemospon Pattern Photo Gel has a thixotropic consistency, enabling pattern carving without runoff and loss of material.

INDICATION:
Hemospon Pattern Photo Gel is indicated for transfer transfers over two or more implants, and is intended for use by dental surgeons and prosthetists.
COMPOSITION:
Methacrylic monomers, silica, initiators and co-initiators.
MODE OF USE:

  1. Choose the color according to your preference and best indication.
  2. Perform asepsis of the region to be worked on, dry it properly.
  3. It is recommended to use protective gloves, as well as to thinly cover neighboring structures (such as teeth and other prostheses) with solid Vaseline, since the material is adhesive.
  4. Remove the syringe cap, fix the tip and apply the amount of material needed to perform the procedure according to the splinting technique.
  5. As it is a light-curing material, after applying the product, it is recommended to remove the application tip and fix the syringe cap again in order not to compromise the product’s performance and functionality.
  6. Model before photoactivation if necessary, because after light application the material becomes rigid, making modeling impossible.
  7. It is recommended that applications be made in layers up to 2 mm thick. If thicker layers are required, intermediate layers are recommended. Photo-activate the product for 30 ± 10 seconds. The dentist may photoactivate in scanning mode, provided the power of the polymerizer is greater than 1 200 mW/cm2.
  8. For implant transfers, it is recommended to cut the bar between the abutments and correct with Hemospon Pattern Photo Gel to minimize the risk of polymerization shrinkage. Finish the specimen where applicable. For intraoral application of the Hemospon Pattern Photo Gel resin, the material is for temporary use and can only be applied intraorally during the impression-taking process.
  9. We recommend the use of  condensation or addition silicones for impression-taking of the abutments after splinting according to the chosen technique.

WARNINGS:

  • Exclusive use of the dental surgeon and prosthetic technicians

  • Do not use the product after its expiration date.

  • Do not reuse empty container.

  • Keep the material out of the reach of children.

  • This material was manufactured for dental use only and must be handled according to the instructions for use. The manufacturer is not responsible for damage caused by other uses or by incorrect handling not described in this  manual. Furthermore, the user is obliged to check, prior to use and under his/her own responsibility, whether this material is compatible with the intended use, especially when this use is not indicated in this directions for use.

  • Hemospon Pattern Photo Gel should not be swallowed or aspirated.
    In case of ingestion or aspiration, seek medical attention immediately.

  • For scanning applications, use a polymerizer with a power greater than 1200 mW/cm².

PRECAUTIONS:

  • Wear PPE when handling the product, including gloves and goggles.
    It is recommended that patients also wear goggles.

  • Do not allow loose polymerized objects and parts to be swallowed or aspirated.

  • Contact of unpolymerized Hemospon Pattern Photo Gel with skin, mucous membranes and eyes should be avoided. When still unpolymerized, the product can have a slight irritating effect.

  • If the product comes into contact with the hands, wash with plenty of water.

  • In case of allergic reactions discontinue use immediately. If necessary, seek medical advice.

  • Single use product.

  • Do not reprocess.

  • Do not expose the material to temperatures above 25°C.

  • Do not expose material directly to sunlight.

  • Replace the cap on the syringe immediately after use.

CONTRAINDICATIONS:
Do not use this material on patients who are allergic or hypersensitive to any component of the formula.

STORAGE AND TRANSPORTATION:

  • Store the product in its original packaging in a clean, dry place.
  • Store Hemospon Pattern Photo gel properly sealed and without exposure to light or high humidity.
  • The product should be kept at a controlled temperature between 4°C – 25 °C.

VALIDITY:
If properly stored, the product has a shelf life of 24 months from the date of manufacture. Do not use after the expiration date.
DISPOSAL:
Do not reuse the product and dispose of in accordance with local legislation.

maquira - logoMADE IN BRAZIL
all Fabricante] Manufacturer:
Maquira Ind~stria de Produtos
Odontol6gicos S.A.
CNPJ: 05.823.205/0001-90
Endere~o [ Direcci~n [ Address:
Av. Melvin Jones, 773
Pq. Ind. Bandeirantes
Maring~ -PR[87070-030]Brasil
Resp. T~cnico ] Technical Resp.:
Cristiane Furlan I CRF-PR: 14.038
Reg. ANVISA N°: 80322409017
SAP:
Atendimento ao cliente
Atenci6n al cliente
Customer service
0800 726 5848
sap@maquira.com.br

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals