PEDROLLO MM 8 Wall Mounted Inverter Instructions

June 1, 2024
pedrollo

PEDROLLO MM 8 Wall Mounted Inverter

Product Information

Specifications

  • Power supply voltage: 1 ~ 230 V
  • Pump motor voltage: 1 ~ 230 V
  • Permissible voltage variation: Standard
  • Supply frequency: 50 Hz
  • Maximum pump motor current: 8.5 A (DG FIT MM 8), Standard (DG FIT MM 11, DG FIT MM 16)
  • Maximum pump motor power: 1.5 HP (1.1 kW)
  • Room temperature: Standard
  • Protection rating: IP 54 (DG FIT MM 11, DG FIT MM 16)
  • RS-485 communication: Standard
  • Dry input contact: Standard
  • Dry contact output: Standard

Product Usage Instructions

Installation

  1. Mount the DG FIT inverter on the wall near the pump.
  2. Connect the inverter to the pump motor following the provided wiring diagram.
  3. Install a membrane expansion tank downstream of the inverter to decrease pump start frequency and absorb excess pressure from the system.

User Interface

The keypad on the DG FIT allows easy access to configuration menus for adjusting operational parameters like system pressure, operating frequency, absorbed current, and alarm messages. LED indicators provide visual status updates.

Troubleshooting

If the pump experiences issues such as dry running, overcurrent, or overheating, refer to the user manual for troubleshooting steps or contact customer support for assistance.

FAQ

Q: Can I connect multiple devices to the DG FIT?

A: Yes, you can connect up to three devices to create pressurization units using the DG FIT.

Q: What is the purpose of the membrane expansion tank in the installation?

A: The expansion tank helps decrease pump start frequency and absorb excess pressure from the system, preventing issues like water hammer.

  • Domestic use
  • Civil use

INSTALLATION AND USE

  • DG FIT is an inverter-based electronic control device de-signed for single-phase surface or submersible pumps.
  • It is utilized for water supply in residential, commercial, and irrigation applications, and is compatible with all types of pressurization systems, including existing ones.
  • DG FIT ensures maximum comfort, extends the system’s ser-vice life, and facilitates significant energy savings.

DG FIT protects the pump from

  • Dry running
  • Overcurrent
  • Overvoltage
  • Undervoltage
  • Overheating
  • Short circuit

PRODUCT DESCRIPTION

DG FIT is a wall-mounted frequency converter which, equip- ped with a pressure sensor, allows the rotation speed of the motor to adjust dynamically according to the amount of wa-ter required, thus ensuring constant pressure in the system.

DG FIT is characterised by:

  • A display and keypad for easy, step-by-step setup of oper-ating parameters with two levels of adjustment:
    • BASIC, for setting pressure and current;
    • ADVANCED, for customizing the inverter for specific system needs.
  • Electronic components are cooled by an integrated fan to ensure heat dissipation.
  • Integrated expansion board, which allows:
    • RS 485 communication for up to three DG FIT to talk to each other
    • configuration of a dry input contact (e.g. float, double set point)
    • configuration of a dry output contact (e.g. alarm)
  • Input signal: pressure sensor
  • Arrangement for wall connection

ADVANTAGES IN USE

  • Easy installation, adjustment and setting.
  • Energy saving due to lower absorption of the pump.
  • Control of hydraulic and electrical operating parameters and protection against faults.
  • Reduced noise operation.
  • Longer pump life.
  • Possibility to connect up to three devices to create pres-surization units

TECHNICAL DATA

TECHNICAL DATA DG FIT MM 8 DG FIT MM 11 DG FIT MM 16
Power supply voltage 1 ~ 230 V 1 ~ 230 V 1 ~ 230 V
Pump motor voltage 1 ~ 230 V 1 ~ 230 V 1 ~ 230 V
Permissible voltage variation ± 10% ± 10% ± 10%
Supply frequency 50/60Hz 50/60Hz 50/60Hz
Maximum pump motor current 8.5 A 11 A 16 A
Maximum pump motor power 1.5 HP (1.1 kW) 2 HP (1.5 kW) 3 HP (2.2 kW)
Room temperature 0 °C ÷ 40 °C 0 °C ÷ 40 °C 0 °C ÷ 40 °C
Protection rating IP 54 IP 54 IP 54
RS-485 communication standard standard standard
Dry input contact standard standard standard
Dry contact output standard standard standard

USER INTERFACE

The keypad simplifies the process of accessing and navigating configu-ration menus, enabling the adjustment, and monitoring of various op-erational parameters, including system pressure, operating frequency, absorbed current, and alarm messages. LED indicators provide quick insights into the pump’s operational status at a glance.

PEDROLLO-MM-8-Wall-Mounted-Inverter-FIG-1

KEY

  1. Power on/off key
  2. Red networking LED
  3. Green run LED
  4. Display
  5. SET button
  6. Menu/parameter input/output arrows
  7. Menu/parameter scrolling arrows

DIMENSIONS (mm)

TYPICAL INSTALLATION

PEDROLLO-MM-8-Wall-Mounted-Inverter-FIG-2

N.B.: it’s neceadvisable to install a membrane EXPAN-SION TANK downstream of the inverter to:

  • decrease pump start frequency
  • absorb excess pressure from the system, like water hammer

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

pedrollo User Manuals

Related Manuals