Product Information
Product Name: | DLK2S SMART INDUSTRIAL LED |
---|---|
Manual Edition: | 1.02 |
Voltage In: | 60W |
IP/IK Rating: | IP66 / IK09 |
Operating Temperature: | Not specified |
AUGMENTED FUNCTIONALITY: | Remote Dimming (10 to 100% remote dimming |
function available as
Cloud feature)
Product Usage Instructions
Installation Instructions
- Step 1: Loosen the six captive screws on the bottom of the DLK2S to remove the cover. Do not remove captive screws from the cover plate.
- Step 2: Feed the cable through the cable gland while sliding the DLK2S to the spigot. Secure using U-Bolts with washers and M8 tube nuts. Proceed to connect wires as required. You can secure the cable using the plastic clamp.
- Step 3: After mounting DLK2S to the spigot and wiring is complete, refit the bottom cover to finish installation.
Conductor Requirements
Conductor Size | Strip Length | Cable OD Min/Max |
---|---|---|
AWG | 7mm/13mm | 24mm wrench required for tightening the cable gland |
Gland Replacement
The cable gland can be replaced by other types of glands which have an M20 x 1.5mm mounting thread. We recommend Loctite 277 for a permanent bond.
Important Notes
- Primary use: conveyor light for commercial and industrial applications. The light source of this luminaire is not replaceable, when the light source reaches its end of life the whole luminaire shall be replaced.
- For more information about Brilliant Connected lights, please visit www.bitcortex.net or scan the QR code.
- For additional technical details and specifications, please visit www.coolon.com.au.
Specifications
Electrical Characteristics
- VOLTAGE IN
- 120 – 240VAC 50/60Hz
- POWER
- 60W
- IP/IK RATING
- IP66 / IK09
- OPERATING TEMP.
- 0 to +50°C
Dimensions
INSTALLATION INSTRUCTIONS
Step 1
- Loosen the six captive screws on the bottom of the DLK2S to remove cover.
- NOTE: Do not remove captive screws from cover plate.
Step 2
- Feed the cable through the cable gland while sliding the DLK2S to the spigot. Secure using U-Bolts with washers and M8 tube nuts.
Proceed to connect wires as required.
You can secure the cable using the plastic clamp.
Conductor Requirements
- Conductor Size: 1 – 6mm2
- AWG: 17 – 10
- Strip Length: 11 – 12mm
- Cable OD Min/Max: 7mm/13mm
NOTE: Housing is earthed internally.
Step 3
- After mounting DLK2S to the spigot and wiring is complete, refit the bottom cover to finish installation.
GLAND REPLACEMENT
- The fitting is supplied with a stainless steel M20 gland to suit cable outer diameter 7 – 13mm. Cable glands are secured using Loctite 243.
- The cable gland can be replaced by other types of glandswhich have a M20 x 1.5mm mounting thread. We recommend Loctite 277 for a permanent bond.
AUGMENTED FUNCTIONALITY
Remote Dimming
- 10 to 100% remote dimming function available as Cloud feature.
scan
- A web based platform to manage and control smart wireless devices.
- Accessible anywhere through an internet connected browser.
- To learn more about Brilliant Connected lights please visit www.bitcortex.net or scan the QR code.
IMPORTANT
Primary use: conveyor light for commercial and industrial applications. The light source of this luminaire is not replaceable, when the light source reaches its end of life the whole luminaire shall be replaced.
- Read through this manual before installation
- Handle the product with care
- The product must be grounded
- The product must be installed by a suitably qualified person
- Turn OFF the power before installation and maintenance
- Make sure the product is securely installed
- The housing might become hot after operation
- Keep optical face clean
Contact
- support@coolon.com.au
- aus: 1300 287 533
- intl: +613 8681 3633
- www.coolon.com.au
Product must be installed by a suitably qualified person. All documentation is subject to change without notice. Refer to our website for the latest information.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>